Other document · Airbus

No revision namedAOT A78P001-18 · 5 pages · 435 KB

© Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2018-1064, the docket of AD 2018-26-07. Not covered by OpenAirDocs’ CC0 dedication.

Docket FAA-2018-1064 (document 0003) · AD 2018-26-07

Manufacturer
Airbus
Type
All Operators Transmission
Number
A78P001-18

A newer revision may exist than any OpenAirDocs knows of: check with the manufacturer.

On this page

Text · 5

From the PDF’s text layer: layout, tables and figures are lost. The PDF is the document. © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2018-1064, the docket of AD 2018-26-07. Not covered by OpenAirDocs’ CC0 dedication.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = 'f087a9fd674e5339056ee7d10dbe59ca17637380f5d9ecda9454c0f090225641'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

CUSTOMER SERVICES DIRECTORATE 2 ROND POINT EMILE DEWOITINE 31700 BLAGNAC FRANCE TELEPHONE + 33 (0)5 61 93 33 33

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A78P001-18 Rev 01 Page 1 of 5 Date: 16-OCT-2018 © AIRBUS S.A.S. 2018. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT SUBJECT: ATA 78 – A350XWB-84K & 97K - Thrust Reverser Actuation System (TRAS) # Actuator # Risk of Jamming & Potential Retention Capabililty Loss AIRCRAFT TYPE: A350 OUR REF.: A78P001-18 Rev 01 dated 16-OCT-2018 OUR PREVIOUS REF: A78P001-18 Rev 00 dated 03-OCT-2018

0. REASON FOR REVISION This AOT is revised to introduce life limitation of the actuators.

The revised paragraphs are indicated between **BEG. REV** and **END REV**.

1. AIRCRAFT AFFECTED A350 -900 and -1000 type.

2. REFERENCED DOCUMENTATION REF 1: A350-A-78-3X-XX-00001-240A-A. - Greasing of the Thrust Reverser Translating-Sleeve Actuators.

REF 2: Appendix A. TRAS Jammed Actuator Troubleshooting Procedures REF 3: MMEL 78-30-01A / 78-30-02A / 78-30-03 / 78-30-04 REF 4: MP TASK A350-A-78-3X-XX-00001-560A-A Deactivation of the Thrust Reverser for Flight

3. REASON The aim of this AOT is to request the operator to perform Thrust Reverser (TRU) Actuator greasing on A350 to prevent actuator ball bearings degradation. This greasing has to be performed every 250FC or 4 Months (whichever occurs first) as per REF 1 independent of TRU actuators cycles or age.

In addition, this AOT provides actions to be performed in case of DISPATCH MESSAGE (DM)

- ENG x REVERSER CTL or

- ENG x REVERSER It is requested to apply MMEL as per REF 3 and to perform troubleshooting as per REF 2 to identify the specific fault codes and defective component.

**BEG. REV** A life limitation for the actuators depending on the greasing initiation and frequency is introduced through this AOT.

**END REV**.

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A78P001-18 Rev 01 Page 2 of 5 Date: 16-OCT-2018 © AIRBUS S.A.S. 2018. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

3.1 FACTS Jamming of TRU Actuators has been reported to AIRBUS with the associated information ECAM Warning Status info Dispatch Message Event ENG x REVERSER CTL FAULT REVERSER INOP ENG x REVERSER CTL Slow to Stow /Slow to Deploy ENG x REVERSER FAULT REVERSER INOP ENG x REVERSER TR jamming There are 6 actuators in total on the TRU (3 per C-duct), of which 4 have a locking function (2 per C- duct).

The affected PN are:

- 351D9908-657

- 351D9908-659

- 351D9908-661 All actuators can be affected (locking and non-locking).

The reason of the jamming condition is that the ball bearings inside the actuators are suffering corrosion due to lack of grease and are degrading with time.

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A78P001-18 Rev 01 Page 3 of 5 Date: 16-OCT-2018 © AIRBUS S.A.S. 2018. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

3.2 CONSEQUENCES When TRU actuator ball bearings degrade, first symptoms are Thrust Reverser Slow to Stow/Slow to Deploy and/or Cowl Jammed.

If the thrust reverser continues to be operated with these symptoms, the actuator ball bearings will continue to degrade and this might result in loss of retention capability of the locking Actuators which is an unsafe condition.

Nevertheless, in-service event analysis has demonstrated that returned actuators due to first symptoms “Slow to Stow/Slow to Deploy or Cowl Jammed” had not lost their retention capability.

This indicates that potential loss of TRU actuator retention capability is preceded by DM ENG x REVERSER CTL or ENG x REVERSER

3.3 AIM The aim of this AOT is to instruct:

- Regular greasing of the thrust reverser actuators every 250FC or 4 Months (whichever occurs first) as per REF 1 to prevent/reduce the progression of the ball bearings corrosion.

- In case of DM oENG x REVERSER CTL or oENG x REVERSER, Perform TRU inhibition as per MP TASK REF 4 to prevent further ball bearings degradation and potential loss of retention capability.

AND Perform specific troubleshooting as per REF 2 prior to MMEL expiration.

**BEG. REV**

- Life Limitation of the TRU Actuators depending on the greasing timing Category 1st Field Greasing Repetitive Greasing Interval Life Limit A 250FC No life limit B Prior 500 FC 500FC 3500 FC C Actuator not from Category A or Category B 2400FC Grace Period 250FC or 4 months whichever occurs first **END REV**.

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A78P001-18 Rev 01 Page 4 of 5 Date: 16-OCT-2018 © AIRBUS S.A.S. 2018. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

4. SHORT TERM ACTION

4.1 PLANNING AND MANPOWER

4.1.1 ACCOMPLISHMENT TIMESCALE **BEG. REV** The greasing as per REF 1 has to be performed within 250FC or 4 Months (whichever occurs first) since A/C delivery and to be repeated every 250FC or 4 Months (whichever occurs first).

If previous greasing was performed more than 250FC ago, next greasing has to be performed within 50FC from AOT issuance date.

The replacement of the TRU Actuators (if required) will have be performed within the following time frame:

- CATEGORY A If first greasing was performed before having accumulated 500FC and then repeated every 250FC, there is no life limitation.

- CATEGORY B If first greasing was performed before having accumulated 500FC and then repeated every 500FC, actuator will have to be replaced prior having accumulated 3500FC.

- CATEGORY C If the actuator is not within CATEGORY A or CATEGORY B, it will have to be replaced prior to 2400FC.

For an actuator having more than 2400FC, a grace period of 250FC or 4 Months (whichever occurs first) since AOT issuance is granted.

**END REV**.

4.1.2 MANPOWER The estimated time to perform the greasing is 3.5 Man-Hours per Nacelle and the inhibition procedure is 1Man-Hour.

4.2 DESCRIPTION

4.2.1 ACCESS For greasing, please refer to TASK REF 1 for details on access, instructions and tooling.

For thrust reverser inhibition, please refer to TASK REF 4.

ALERT OPERATORS TRANSMISSION - AOT AOT ref: A78P001-18 Rev 01 Page 5 of 5 Date: 16-OCT-2018 © AIRBUS S.A.S. 2018. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

5. FURTHER INFORMATION

5.1 FOLLOW UP PLAN **BEG. REV** An Airworthiness Directive is expected to mandate the actions instructed in the AOT.

**END REV**.

5.2 IMPACTED DOCUMENTATION **BEG. REV** AFI TASK associated to DM ENG x REVERSER FAULT and ENG x REV CTL FAULT will be updated to refer to NEW MP TASK reflecting REF 2 content.

AFI TASK update is expected no later than end of October 2018.

**END REV**.

AOT APPROVAL The technical content of this document is approved under the authority of DOA nr. EASA.21J.031.

6. REPORTING Questions about this AOT are to be addressed to Airbus Customer Services through TechRequest on Airbus World, selecting Maintenance & Engineering Domain, Engineering Support Section and ATA 78-30 TOPIC Thrust Reverser Actuator Jamming.

As per latest reporting policy (Ref to OIT 999.0018/16), inspection results (with or without findings) are to be addressed to Airbus Customer Services through the generic e-mail address:

inspection.results@airbus.com.

Best Regards, Jean-Luc MOUYSSET

VICE PRESIDENT ENGINEERING SUPPORT

CUSTOMER SERVICES Stéphane GOSSELIN VICE PRESIDENT A350 PROGRAMME

CUSTOMER SERVICES