Other document · ATR

No revision namedTL 42-500-TR 01-17 for approval · 4 pages · 52 KB

© ATR. Filed by the FAA in regulations.gov docket FAA-2018-0366, the docket of AD 2018-20-14. Not covered by OpenAirDocs’ CC0 dedication.

Docket FAA-2018-0366 (document 0005) · AD 2018-20-14

Manufacturer
ATR
Type
Temporary Revision
Number
42-500 01-17

A newer revision may exist than any OpenAirDocs knows of: check with the manufacturer.

On this page

Text · 4

From the PDF’s text layer: layout, tables and figures are lost. The PDF is the document. © ATR. Filed by the FAA in regulations.gov docket FAA-2018-0366, the docket of AD 2018-20-14. Not covered by OpenAirDocs’ CC0 dedication.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '73f5c326d7faed91a5d4c170a5ca86d2ee6634e7d85306ee6a1e9d6a7cddcd27'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

ATR42-400/-500 TIME LIMITS

RECORDS OF TEMPORARY REVISION Date : May 3rd, 2017 REV: TR01/17 ISSUE: MAY 17 Printed in France REVISION N° DATE APPROVAL TR01/17 applicable to REV.11 May 2017

ATR42-400/-500 TIME LIMITS

LIST OF TEMPORARY EFFECTIVE PAGES Date May 3 rd, 2017 TR01/17 ISSUE: MAY 17 Page: 1-LEP-TR Printed in France

PAGE DATE 1-LEP-TR May 17 1-RFTR-01/17 May 17 R 6-2 May 17

ATR42-400/500 TIME LIMITS

REASONS FOR TEMPORARY REVISION TR01/17 Date May 3 rd, 2017 TR01/17 ISSUE: MAY 17 Page: 1-RFTR- 01/17 Printed in France Page 1-LEP-TR List of effective pages TR 01/17 Page 1-RFTR-01/17 Details of temporary revision TR01/17 Page 6-2 Addition of missing CMR 212300-1 for testing overboard valve in venturi position Addition of new CMR on ATA 21-31-00 further to in-service incident linked to overpressure relief valves inoperative Addition of missing CMR 213100-4 for operational check of ditching system

ATR42-400/-500 TIME LIMITS

CERTIFICATION MAINTENANCE REQUIREMENTS Date : May 3rd, 2017 TR 01/17 ISSUE: MAY 17 Page: 6-2 Printed in France

6.2. CMR TABLES

MSI MSI AND TASK DESCRIPTION MAXINTERVAL EFFECT N 212300 AIR DISTRIBUTION SYSTEM 212300-1 Operational check of overboard valve in venturi position 8000 FH ALL R 213100 CABIN PRESSURE AND CONTROL MONITORING 213100-1 Functional test of excessive cabin altitude warning 2000 FH POST 6242 N 213100-2A Functional check of outflow valves overpressure relief 8200 FH PRE 5948 N 213100-2B Functional check of outflow valves overpressure relief 5700 FH POST 5948 N 213100-3A Functional check of triple indicator 10000 FH PRE 6242 N 213100-3B Functional check of triple indicator 9100 FH POST 6242 N 213100-4 Operational check of ditching system 20000 FH ALL 220000 AUTO FLIGHT 220000-4 Operational test of tab offset warning 4000 FH ALL 243100 BATTERIES - DC GENERATION 243100-1 Check of batteries voltage on maintenance panel 48 FH ALL 243100-6 Operational check of STBY override function and associated indicating 1400 FH ALL 243100-11 Operational test of TRU system 400 FH ALL 262100 ENGINE FIRE EXTINGUISHING 262100-3 Functional check of distribution pipe integrity and water drains 8000 FH ALL 262100-6 Perform "SQUIB TEST" 16000 FH ALL 271200 TRIM - AILERON 271200-2 Operational test of aileron trim control switches 800 FH ALL 272200 TRIM - RUDDER 272200-2 Operational test of rudder trim control switches 400 FH ALL 272300 RUDDER TRAVEL LIMITER UNIT 272300-3 Operational test of the Travel Limiter Unit 4000 FH ALL 272300-4 Operational test of "t.o." warning with the Travel Limiter Unit in high speed position 10000 FH ALL