Text
From the PDF’s text layer: layout, tables and figures are lost. The PDF is the document.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '800c60417c262407f5b591d8571195c71a68b811f156c392e163bbd027da1105' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '800c60417c262407f5b591d8571195c71a68b811f156c392e163bbd027da1105' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
Mandatory Service Bulletin No. MSB-E4-022/3 Austro Engine GmbH Rudolf-Diesel-Strasse 11 2700 Wiener Neustadt PHONE: +43 2622 23000 FAX: +43 2622 23000-2711
First Issue Date Rev. No. Revision Date Page 02 Nov 2017 03 16 Apr 2018 1-5 © 2017 by Austro Engine GmbH – AUSTRIA – www.austroengine.at SUPERSEDES MSB-E4-022/2
1. BASIC INFORMATION
1.1. SUBJECT Waste Gate Control Rod.
1.2. ENGINES AFFECTED Engine type: E4
Engine model(s): E4, E4P
Serial number(s): all
1.3. REASON Waste gate control rods with insufficient fatigue life have been identified. Failure of the waste gate control rod will lead to a partial loss of power.
As precautionary action Austro Engine prescribes a time limit for the waste gate controllers without waste gate con-rod fail-safe bridge.
As terminating action for the time limit the waste -gate control-rod fail-safe bridge has been introduced. After installation of the waste -gate control-rod fail-safe bridge the waste -gate controller is set on condition with specified scheduled maintenance c hecks per Maintenance Manual.
1.4. TIME OF COMPLIANCE Initial action:
Upon reaching 250 flight hours in service time of the waste gate controller For E4-B and E4-C engines installed on DA 42 M-NG with external containers and E4-A engines:
For waste-gate controllers with more than 200 flight hours as of 27-Nov-2017 within the next 50 flight hours, but not later than 28-Feb-2018 if 250 flight hours in service time of the waste gate controller are exceeded as of 28-Feb-2018.
All other engines:
For waste-gate controllers with more than 200 flight hours as of 27-Nov-2017 within the next 100 flight hours, but not later than 31-May-2018 if 250 flight hours in service time of the waste gate controller are exceeded as of 31-May-2018.
Mandatory Service Bulletin No. MSB-E4-022/3 Austro Engine GmbH Rudolf-Diesel-Strasse 11 2700 Wiener Neustadt PHONE: +43 2622 23000 FAX: +43 2622 23000-2711
First Issue Date Rev. No. Revision Date Page 02 Nov 2017 03 16 Apr 2018 2-5 © 2017 by Austro Engine GmbH – AUSTRIA – www.austroengine.at Repetitive Action:
Upon reaching 250 flight hours in service time of the waste gate controller
Terminating Action:
Within 200 flight hours after 30-Apr-2018, but not later than 31-Oct-2018
Prior compliance with MSB-E4-022 through MSB-E4-022/2 is considered equivalent to the initial action or repetitive action, as applicable.
1.5. CONCURRENT DOCUMENTS / REFERENCES
- Maintenance Manual E4 Series – Doc. No.: E4.08.04, latest effective issue
1.6. OTHER PUBLICATIONS AFFECTED None.
2. TECHNICAL DETAILS
2.1. ACCOMPLISHMENT / INSTRUCTIONS Initial Action:
1. Make sure MM-TR-MDC-E4-386 and MM-TR-MDC-E4-399 are inserted into the Maintenance Manual or a revision of the Maintenance Manual with the Temporary Revisions incorporated is used.
2. Replace the waste gate controller according to Maintenance Manual section 81-00-
33.
3. Install a new the spring loaded circlip E4A-41-100-801. Refer to figure 4
Repetitive Action:
1. Replace the waste gate controller according to Maintenance Manual section 81-00-
33.
2. Install a new the spring loaded circlip E4A-41-100-801. Refer to figure 4.
Mandatory Service Bulletin No. MSB-E4-022/3 Austro Engine GmbH Rudolf-Diesel-Strasse 11 2700 Wiener Neustadt PHONE: +43 2622 23000 FAX: +43 2622 23000-2711
First Issue Date Rev. No. Revision Date Page 02 Nov 2017 03 16 Apr 2018 3-5 © 2017 by Austro Engine GmbH – AUSTRIA – www.austroengine.at Terminating Action:
1. Make sure MM-TR-MDC-E4-422 is inserted into the Maintenance Manual or a revision of the Maintenance Manual with the Temporary Revisions incorporated is used.
2. If not yet installed, install a new spring loaded circlip E4A-41-100-801. Refer to figure 4.
3. Install the waste-gate con-rod fail-safe bridge according to Maintenance Manual section 81-00-36 or install a waste-gate controller with the fail-safe con-rod bridge already installed. Make sure there is sufficient clearance to adjacent parts.
Figure 4: Waste Gate Circlip
2.2. MASS (WEIGHT) Negligible.
2.3. APPROVAL STATEMENT The technical content of this document has been approved under the authority of DOA No.
EASA.21J.399.
Mandatory Service Bulletin No. MSB-E4-022/3 Austro Engine GmbH Rudolf-Diesel-Strasse 11 2700 Wiener Neustadt PHONE: +43 2622 23000 FAX: +43 2622 23000-2711
First Issue Date Rev. No. Revision Date Page 02 Nov 2017 03 16 Apr 2018 4-5 © 2017 by Austro Engine GmbH – AUSTRIA – www.austroengine.at
3. PLANNING INFORMATION
3.1. MATERIAL & AVAILABILITY For replacement of the waste-gate controller:
Qty Part Number Description 1 E4A-41-120-000 Waste Gate Controller 1 E4A-41-100-801 Spring loaded circlip
For the terminating action:
Qty Part Number Description 1 E4A-41-100-801 Spring loaded circlip (if not yet installed) 1 AEP-00265-100 Bracket Assy 1 1 AEP-00265-100 Bracket Assy 2 2 AEP-00247-801 Screw with drill hole 2 E4A-53-300-801 Screw with drill hole
3.2. SPECIAL TOOLS As stated in the Maintenance Manual E4.08.04.
3.3. LABOR EFFORT
0.5 hours.
Mandatory Service Bulletin No. MSB-E4-022/3 Austro Engine GmbH Rudolf-Diesel-Strasse 11 2700 Wiener Neustadt PHONE: +43 2622 23000 FAX: +43 2622 23000-2711
First Issue Date Rev. No. Revision Date Page 02 Nov 2017 03 16 Apr 2018 5-5 © 2017 by Austro Engine GmbH – AUSTRIA – www.austroengine.at
4. REMARKS
NOTE:
o All measures must be carried out by a certified engine station and certified engine mechanics.
o The accomplishment of the instructions shown under chapter 2.1 must be confirmed in the respective engine log book.
o The accomplishment of the instructions must be carried out within the time of compliance according chapter 1.
o In case of doubt please contact the Austro Engine GmbH – After Sales Support (e-mail: service@austroengine.at; Tel: +43 2622 23000 2525).
o For credit information contact Austro Engine GmbH – After Sales Support (e-mail: service@austroengine.at; Tel: +43 2622 23000 2525)
5. EXPLANATORY NOTES
5.1. SYMBOL EXPLANATION WARNING: Disregarding these safety rules can cause personal injury or even death
CAUTION: Disregarding these special instructions and safety measures can cause damage to the engine or other components.
NOTE: Additional note or instruction for better understanding of an instruction