From the PDF’s text layer: layout, tables and figures are lost. The PDF is the document. © B/E Aerospace. Filed by the FAA in regulations.gov docket FAA-2016-4228; AD 2016-25-08 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '3ac66a413733b319d58d9d80960ce109b91862d17c9bb281ace5d24deac0e5f6' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '3ac66a413733b319d58d9d80960ce109b91862d17c9bb281ace5d24deac0e5f6' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 1 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
REVISION TRANSMITTAL SHEET
This sheet transmits Revision 02 to Service Bulletin 1XCXX-0100-35-005
REASON FOR REVISION
Serial Number sequence added.
NOTES: The Service Bulletin is fully re-printed.
Bars on the right margin identify the changes
REVISION SEQUENCE
ORIGINAL: MAR/14/2011
Revision 1: DEC/15/2011
Revision 02: JUL/10/2014
Date: JUL/10/2014
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 2 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
ATA SYSTEM: 35
TITLE: OXYGEN – CHEMICAL PASSENGER EMERGENCY OXYGEN CONTAINER-
IMPROVEMENT OF THE MASK HOSE CONNECTION
1. PLANNING INFORMATION A. EFFECTIVITY This service bulletin is applicable to all chemical oxygen container assemblies Type I (15/22 Minutes) that are listed below.
Spare units may be affected as well.
(1) Part numbers of the applicable passenger emergency oxygen container assemblies:
Part Numbers Type I 15 Min 13C15L215170100 13C15L215460100 13C15R215170100 13C15R215460100 14C15L215020100 14C15L215170100 14C15L215460100 14C15L2F5460100 14C15R215020100 14C15R215170100 14C15R215460100 14C15R2F5460100
Part Numbers Type I 22 Min 13C22L215460100 13C22R215460100 14C22L215020100 14C22L215460100 14C22L2F5460100 14C22R215020100 14C22R215460100 14C22R2F5460100
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 3 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
(2) Serial numbers of the affected passenger emergency oxygen container assemblies:
from ARBA-0000 to ARBA-9999-Series from ARBB-0000 to ARBB-9999-Series from ARBC-0000 to ARBC-9999-Series from ARBD-0000 to ARBD-9999-Series from ARBE-0000 to ARBE-9999-Series from BEBE-0000 to BEBE-9999-Series from BEBF-0000 to BEBF-9999-Series from BEBH-0000 to BEBH-9999-Series from BEBK-0000 to BEBK-9999-Series from BEBL-0000 to BEBL-9999-Series from BEBM-0000 to BEBM-9999-Series NOTE: As far as still available at the Airbus final assembly line a few aircrafts have already been reworked before handover to the operator .Those units have been marked with a green dot on the test button label as shown below and do not need further rework.
B. CONCURRENT REQUIREMENTS For 1XC15-0100-Series Oxygen Container - Not Applicable For all 1CX22-0100-Series Oxygen Container This SB requires the simultaneously accomplishment of the Service Bulletin No.
1XC22_0100-35-006.
C. REASON During manufacturing at the manufacturer facilities particles had been detected in the oxygen generator manifolds. Investigation revealed that those particles (chips) are chafed from the mask hoses when installed onto the generator outlets. It was found out that a defective mask hose installation device has caused the chips. Such chips may reduce or block the oxygen supply .
Green Dot
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 4 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
A replacement of the manifold is necessary.
D. DESCRIPTION This Service Bulletin specifies the replacement of the Manifold.
(See Para. 3. ACCOMPLISHMENT INSTRUCTIONS of this SB) E. COMPLIANCE Mandatory F. APPROVAL The technical content of this document is approved under the authority of DOA No. EASA.21J.031.
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 5 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
G. MANPOWER For 1XC15-0100 Series Oxygen Container This Service Bulletin may be accomplished on the Aircraft or in the work shop. The estimated time to do the work in this Service Bulletin is 0.30 hours per oxygen container.
(1) Open the door of the oxygen container.
(2) Remove and secure the mask assemblies with rubber bands against uncoiling (preferable by a second person). Disconnect the mask lanyards (remain attached to the release pin) at the mask assemblies.
(3) Remove the manifold together with mask hoses from the oxygen generator, cut the mask hoses from the manifold fittings. Discard the manifold.
(4) Install the mask hoses to the fittings of a new manifold, install the manifold back to the oxygen generator.
(5) Connect the mask lanyards to the mask assemblies. Repack the oxygen mask assemblies and close the door assy.
(6) Do a manual door release test with test button in test position For 1XC22-0100-Series Oxygen Container This Service Bulletin is recommended to be performed in a workshop within the following approximate man-hours and elapsed time of 0.5 hours per oxygen container.
NOTE: The man-hours and elapsed time do not include the removal/installation of the oxygen container from/to the aircraft.
(7) Open the door of the oxygen container, secure the mask assemblies with a rubber band, remove the oxygen generator together with the mask assemblies.
Disconnect the mask lanyards (remain attached to the release pin) at the mask assemblies
(8) Remove the manifold together with mask hoses from the oxygen generator, cut the mask hoses from the manifold fittings. Discard the manifold.
(9) Install the mask hoses to the fittings of a new manifold, install the manifold back to the oxygen generator.
(10) Connect the mask lanyards to the mask assemblies.
(11) Install the oxygen generator together with the mask assemblies back into the container. Repack the oxygen mask assemblies and close the door assy.
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 6 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
(12) Do a manual door release test with test button in test position.
H. WEIGHT AND BALANCE Weight: not affected Balance: not affected
J. REFERENCE This Service Bulletin is covered by Aircraft Inspection Service Bulletin Number A320-35-1047.
CMM 35-21-15, Disassembly/Assembly (D1379)
CMM 35-21-16 Disassembly/Assembly (D1379)
K. PUBLICATION AFFECTED CMM 35-21-15 (D1379)
CMM 35-21-16 (D1379)
L. INTERCHANGEABILITY OF PARTS Refer to aircraft Service Bulletin No. 35-1047 ".
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 7 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
2. MATERIAL INFORMATION A. MATERIAL COST AND AVAILABILITY The cost of the Service Bulletin application are: Free of Charge (FOC) For part procurements and warranty claim please contact:
B/E Aerospace Systems GmbH Revalstrasse 1 23560 Lübeck
GERMANY
Cage Code : D1379
Tel: (49) 451 4093-2976 Fax: (49) 451 4093-4488 e-mail: dieter_heins@beaerospace-systems.com
B. INDUSTRIE SUPPORT INFORMATION NOTE: It is recommended that completion of this Service Bulletin be performed by authorized personnel only. It is recommended to perform this SB work in a workshop. Customized solutions may be negotiated separately
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 8 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
C. MATERIAL NECESSARY FOR EACH OXYGEN CONTAINER ASSY The following Table shows all parts necessary to perform this SB work New PNR Keyword Old PNR QTY Price Type of Container 12C15 13C15 14C15 12C22 13C22 14C22 E63281-00 Manifold 2P E63281-00 1 FOC E63381-00 Manifold 3P E63381-00 1 FOC E63481-00 Manifold 4P E63481-00 1 FOC E63282-01 Manifold 2P E63282-01 1 FOC E63382-00 Manifold 3P E63382-00 1 FOC E63482-00 Manifold 4P E63482-00 1 FOC E71070-00 Pin,Grooved (as required) E71070-00 2 2 2 2 2 2 FOC E20274-06 O-Ring E20274-06 1 1 1 1 1 1 FOC E63047-00 Cable Tie 1 2 2 FOC E61063-00 Disc, Spring loaded (as required) E61063-00 1 1 1 1 1 1 FOC
D. TOOLING – PRICE AND AVAILABILITY Special Tools Part Number Price / Availability Source Manual Release Tool E60100-00 (D1379) Rubber bands - - - - Local Purchase Mask Hose Assembly Tool 2231070 (D1379) Cutter Knife, Hose Cutter - - - - Local Purchase Removal Tool (removal of grooved pins) E61088-00 (D1379) Marker, permanent (green color) STABILO - - Local Purchase Pointed Pliers - - Local Purchase
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 9 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
Special Tools Part Number Price / Availability Source Pliers (Warning Flag installation) E71516-00 (D1379) Cable Tie Pliers 2231453 (D1379)
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 10 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
3. ACCOMPLISHMENT INSTRUCTIONS A. GENERAL General service information is given within the component maintenance m anuals.
WARNING: STRICTLY OBEY THE PROCEDURES FOR THE USE OF OXYGEN EQUIPMENT. DO NOT USE ANY OIL, GREASE, HYDRO CARBONS
OR OTHER LUBRICANTS MADE FROM PETROLEUM IN THE WORK AREA OF THIS OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE HAZARD.
B. LIST OF MATERIALS New PNR Keyword Old PNR QTY Inst/Disp Type of Container 12C15 13C15 14C15 12C22 13C22 14C22 E63281-00 Manifold 2P E63281-00 1 Replaced E63381-00 Manifold 3P E63381-00 1 Replaced E63481-00 Manifold 4P E63481-00 1 Replaced E63282-01 Manifold 2P E63282-01 1 Replaced E63382-01 Manifold 3P E63382-01 1 Replaced E63482-01 Manifold 4P E63482-01 1 Replaced E71070-00 Pin,Grooved E71070-00 2 2 2 2 2 2 On Condition E20274-06 O-Ring E20274-06 1 1 1 1 1 1 Replaced E61063-00 Disc, Spring loaded E61063-00 1 1 1 1 1 1 On Condition E63047-00 Cable Tie E63047-00 1 2 2 Replaced
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 11 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
Special Tools Part Number Source Manual Release Tool E60100-00 (D1379) Rubber bands - - Local Purchase Mask Hose Assembly Tool 2231070 (D1379) Cutter Knife, Hose Cutter - - Local Purchase Pin Removal Tool ( for grooved pins) E61088-00 (D1379) Marker, permanent (green color) STABILO Local Purchase Pointed Pliers - - Local Purchase Cable Tie Pliers 2231453 (D1379) Pliers (Warning Flag installation) E71516-00 (D1379)
SERVICE BULLETIN 1XCXX-0100-35-005
Original Issue Mar/14/2011 Page 12 of 38 Rev.: 2 Jul/10/2014 SB 1XCXX-0100-35-005
FOR 1XC15 CONTAINER ASSEMBLIES (SB ACCOMPLISHMENT ON AIRCRAFT OR
IN THE WORKSHOP) C. DISASSEMBLY WARNING: STRICTLY OBEY THE PROCEDURES FOR USE OF OXYGEN EQUIPMENT. DO NOT USE ANY OIL, GREASE OR OTHER
LUBRICANTS MADE F ROM PETROL IN THE WORK AREA OF THIS OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE HAZARD RESULTING IN SERIOUS PERSONAL INJURY OR DEATH.
CAUTION: IN GENERAL THE WORK ON OXYGEN EQUIPMENT REQUIRES THE USE OF LINT -FREE GLOVES. HOWEVER SOME STEPS OF THIS REWORK M AY BE HINDERED WHEN W EARING GLOVES.
THEREFORE THIS REWOR K IS RECOMMENDED TO BE DONE WITH DRY AND CLEAN FINGER S. ENSURE YOUR FINGE RS ARE DRY AND CLEAN.
(1) Open the Door Assy as follows:
CAUTION: EXERCISE CAUTION WITH THE MASK LANYARDS WHEN YOU OPEN
THE DOOR ASSY, AN ACCIDENTAL PULL CAN REMOVE THE
RELEASE PIN FROM THE OXYGEN GENERATOR ASSY AND START THE FLOW OF OXYGEN THAT CANNOT BE STOPPED.
(a) Set the test button into the test position.
(b) Put the manual release tool PNR E60100-00 into the release access hole of the door assembly. Unlock the door latch with a slight push. The door must open a few degrees (See Figure 1).
Figure 1