Page 193Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727A TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.

Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.

FIGURE 31: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 193 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 194OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 2, Configuration 1.

STA STA 827 727A

STA STA 1016 727 S-1 0000000000002000 - S-14R

FWD FRAME

UPPER SKIN

LOWER SKIN

TYPICAL CRACK

STRINGER-

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851567 FIGURE 32: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 194 of 227

Page 195Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 827 SKIN - LAP SPLICEInspect1

(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.

Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.

FIGURE 32: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 195 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 196OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 7.

STA 1016 STA 727 i Does SZTA

SIZA STA 1016 S-1 000000 - S-14L WD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE A INSPECTION AREA 2851561 FIGURE 33: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 196 of 227

Page 197Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727A TO STA 908 SKIN - LAP SPLICEInspect1

(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.

Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.

FIGURE 33: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 197 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 198OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 3, Configuration 1.

STA STA 747 727A STA 1016 000003000 - S-14R FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851571 FIGURE 34: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 198 of 227

Page 199Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 727A TO STA 747 SKIN - LAP SPLICEInspect1

(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.

Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.

FIGURE 34: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 199 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 200OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 8.

STA 1016 STA 727

STA STA 727G 908

STA STA 727 1016 S-1 000000 - S-14L WD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE A INSPECTION AREA 2851562 FIGURE 35: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 200 of 227

Page 201Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14L, STA 727G TO STA 908 SKIN - LAP SPLICEInspect1

(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.

Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.

FIGURE 35: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 201 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 202OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 3, Configuration 1.

STA 727

STA STA 847 747 STA 1016 S-1 0000000800000000 S-14R

FWD FRAME

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851572 FIGURE 36: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 Copyright © Unpublished 737-53A1382 RB Work - See page 1 for details. 202 of 227

Page 203Open in PDF

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)1S-14R, STA 747 TO STA 847 SKIN - LAP SPLICEInspect1

(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.

Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.

FIGURE 36: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: May 06, 2019 737-53A1382 RB 203 of 227 REQUIREMENTS BULLETIN 737-53A1382

ALERTALERT

Page 204OCROpen in PDF

REQUIREMENTS BULLETIN 737-53A1382

ALERT ALERT This Figure applies only to: Group 9, Configuration 1; Group 10.

STA 1016 STA 727 <2b 1 e00г

STA STA 727A 827 STA 1016 000000000 - S-14L FRAME FWD

UPPER SKIN *LOWER SKIN

TYPICAL CRACK

STRINGER

TYPICAL SKIN LAP SPLICE /A INSPECTION AREA 2851563 FIGURE 37: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY

EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 204 of 227

Pages 205–216 of 227