duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '5f45669c09d2afd8c3b03cedac261fedbc9611f8ef2972ef20448774a7835e0a' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '5f45669c09d2afd8c3b03cedac261fedbc9611f8ef2972ef20448774a7835e0a' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
Group 6:
Upper Deck Floor Beam Station (STA) 860 NotesExisting Part NumberNameQTYPart Number / Specification
(c) (d)BACB30MY6K*Bolt156BACB30NX6K7X
(c) (d)BACB30NX8K*Bolt14BACB30NX8K11X
(c)-Collar226BACC30BH6
(c)-Collar2BACC30BH8
(c)-Collar16BACC30M8
(c) (d)BACR15BB6D*Rivet156BACR15BB6D6C or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet14BACR15BB6D7C or BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1000 NotesExisting Part NumberNameQTYPart Number / Specification
(a) (b)65B25644-3 or 65B26469-1 Upper Chord165B25644-3 or 65B26469-1
(a) (b)65B25644-6 or 65B26469-3 Reinforcement Angle L/H165B25644-6 or 65B26469-3
(a) (b)65B25644-7 or 65B26469-4 Reinforcement Angle R/H165B25644-7 or 65B26469-4
(c) (d)BACB30MY5K*Bolt86BACB30MY6K4 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 109 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1000 NotesExisting Part NumberNameQTYPart Number / Specification
(c) (d)BACB30MY5K*Bolt17BACB30MY6K5
(c) (d)BACB30MY5K*Bolt2BACB30MY6K6
(c) (d)BACB30MY8K*Bolt6BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt6BACB30MY8K9X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K10X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt20BACB30NW6K6X
(c) (d)BACB30NW6K*Bolt1BACB30NW6K7X
(c) (d)BACB30NX6K*Bolt7BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt5BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt9BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt14BACB30NX6K5X
(c)-Collar35BACC30BH6
(c)-Collar150BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D4C or BACR15BA4D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or BACR15BA4D*C
(c) (d)BACR15BA4D*Rivet2BACR15BA4D4C or BACR15BA5D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet29BACR15BB5D5C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet113BACR15BB5D6C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet10BACR15BB5D7C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or BACR15BB7D*C Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 110 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1000 NotesExisting Part NumberNameQTYPart Number / Specification
(c) (d)BACR15BB6D*Rivet2BACR15BB6D8C or BACR15BB7D*C
(c) (d)BACR15CE5D*Rivet1BACR15GF5D5 or BACR15GF6D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1020 NotesExisting Part NumberNameQTYPart Number / Specification
(a) (b)65B25645-3 or 65B26469-9 or 65B26469-30 or 65B26469-33 Upper Chord165B25645-3 or 65B26469-9 or 65B26469-30 or 65B26469-33
(a) (b)65B25645-4 or 65B26469-5 Reinforcement Angle L/H165B25645-4 or 65B26469-5
(a) (b)65B25645-5 or 65B26469-6 or 65B26469-31 Reinforcement Angle R/H165B25645-5 or 65B26469-6 or 65B26469-31
(c) (d)BACB30MY5K*Bolt82BACB30MY6K4
(c) (d)BACB30MY5K*Bolt15BACB30MY6K5
(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 111 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1020 NotesExisting Part NumberNameQTYPart Number / Specification
(c) (d)BACB30NW6K*Bolt10BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c) (d)BACB30MY6K*Bolt1BACB30NX6K3X
(c) (d)BACB30NX6K*Bolt5BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt6BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c)-Collar30BACC30BH6
(c)-Collar132BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D4C or BACR15BA4D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or BACR15BA4D*C
(c) (d)BACR15BB5D*Rivet137BACR15BB5D5C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet16BACR15BB5D6C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D8C or BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6DC or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet10BACR15BB6D6C or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D8C or BACR15BB7D*C
(c) (d)BACR15CE3D*Rivet4BACR15GF3D5 or BACR15GF4D*
(c) (d)BACR15CE4D*Rivet2BACR15GF4D5 or BACR15GF5D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 112 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1020 NotesExisting Part NumberNameQTYPart Number / Specification
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1040 NotesExisting Part NumberNameQTYPart Number / Specification
(a) (b)65B25646-3 or 65B26469-24 Upper Chord165B25646-3 or 65B26469-24
(a) (b)65B25646-4 or 65B26469-25 Reinforcement Angle L/H165B25646-4 or 65B26469-25
(a) (b)65B25646-5 or 65B26469-26 Reinforcement Angle R/H165B25646-5 or 65B26469-26
(c) (d)BACB30MY5K*Bolt80BACB30MY6K4
(c) (d)BACB30MY5K*Bolt15BACB30MY6K5
(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt16BACB30NW6K6X
(c) (d)BACB30NX6K*Bolt7BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt4BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c)-Collar27BACC30BH6 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 113 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1040 NotesExisting Part NumberNameQTYPart Number / Specification
(c)-Collar131BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or BACR15BA4D*C
(c) (d)BACR15BB5D*Rivet27BACR15BB5D5C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet117BACR15BB5D6C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet12BACR15BB5D7C or BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet7BACR15BB6D7C or BACR15BB7D*C
(c) (d)BACR15CE5D*Rivet2BACR15GF5D7 or BACR15GF6D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1060 NotesExisting Part NumberNameQTYPart Number / Specification
(a) (b)65B25647-2 or 65B26469-11 Upper Chord165B25647-2 or 65B26469-11 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 114 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1060 NotesExisting Part NumberNameQTYPart Number / Specification
(a) (b)65B25647-7 or 65B26469-7 Reinforcement Angle L/H165B25647-7 or 65B26469-7
(a) (b)65B25647-8 or 65B26469-8 Reinforcement Angle R/H165B25647-8 or 65B26469-8
(c) (d)BACB30MY5K*Bolt95BACB30MY6K4
(c) (d)BACB30MY5K*Bolt16BACB30MY6K5
(c) (d)BACB30MY8K*Bolt2BACB30MY8K6X
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K3X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt16BACB30NW6K5X
(c) (d)BACB30MY6K*Bolt3BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt18BACB30NX6K5X
(c)-Collar21BACC30BH6
(c)-Collar137BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet93BACR15BB5D5C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet61BACR15BB5D6C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet7BACR15BB5D7C or BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet5BACR15BB6D7C or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D8C or BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 115 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1060 NotesExisting Part NumberNameQTYPart Number / Specification
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1080 NotesExisting Part NumberNameQTYPart Number / Specification
(a) (b)65B25648-2 or 65B26469-13 Upper Chord165B25648-2 or 65B26469-13
(a) (b)65B25648-7 or 65B26469-15 Reinforcement Angle L/H165B25648-7 or 65B26469-15
(a) (b)65B25648-8 or 65B26469-16 Reinforcement Angle R/H165B25648-8 or 65B26469-16
(c) (d)BACB30MY5K*Bolt74BACB30MY6K4
(c) (d)BACB30MY5K*Bolt6BACB30MY6K5
(c) (d)BACB30MY5K*Bolt2BACB30MY6K6
(c) (d)BACB30MY8K*Bolt2BACB30MY8K6X
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K3X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt20BACB30NW6K5X
(c) (d)BACB30MY6K*Bolt3BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt18BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt3BACB30NX6K6X
(c)-Collar14BACC30BH6
(c)-Collar120BACC30M6
(c)-Collar18BACC30M8 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 116 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1080 NotesExisting Part NumberNameQTYPart Number / Specification
(c) (d)BACR15BB5D*Rivet93BACR15BB5D5C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet58BACR15BB5D6C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet5BACR15BB5D7C or BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet9BACR15BB6D7C or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D8C or BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1100 NotesExisting Part NumberNameQTYPart Number / Specification
(a) (b)65B25649-2Upper Chord165B25649-2
(a) (b)65B25649-7Reinforcement Angle L/H165B25649-7
(a) (b)65B25649-8Reinforcement Angle R/H165B25649-8
(c) (d)BACB30MY5K*Bolt61BACB30MY6K4
(c) (d)BACB30MY6K*Bolt2BACB30MY6K4X
(c) (d)BACB30MY5K*Bolt3BACB30MY6K5 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 117 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1100 NotesExisting Part NumberNameQTYPart Number / Specification
(c) (d)BACB30MY6K*Bolt14BACB30MY6K5X
(c) (d)BACB30MY8K*Bolt18BACB30MY8K7X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt16BACB30NW6K6X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K3X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K5X
(c) (d)BACB30NX6K*Bolt11BACB30NX6K6X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K7X
(c) (d)BACB30NX6K*Bolt4BACB30NX6K8X
(c) (d)BACB30NX6K*Bolt1BACB30NX6K9X
(c) (d)BACB30NX6K*Bolt1BACB30NX6K10X
(c) (d)BACB30NX6K*Bolt1BACB30NX6K11X
(c)-Collar54BACC30BH6
(c)-Collar100BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet14BACR15BB5D5C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet108BACR15BB5D6C or BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet15BACR15BB5D7C or BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D7C or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet3BACR15BB6D8C or BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 118 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Group 5:
Upper Deck Floor Beam Station (STA) 1100 NotesExisting Part NumberNameQTYPart Number / Specification
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
3. Parts Modified and Reidentified:
None.
4. Parts Removed and Not Replaced:
None.
D. Parts Necessary to Change Spares None.
E. Special Tooling - Price and Availability None.
F. Special Tooling Necessary to do this Service Bulletin No special tools or equipment are necessary to do the change in this service bulletin. But, maintenance and overhaul tools in the manuals given in Paragraph 1.J., References, can be necessary. Examine operator tool supply to make sure all necessary tools are available.
Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 119 of 189 BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: June 22, 2012 747-53A2852 120 of 189 BOEING SERVICE BULLETIN 747-53A2852