Copy · SB BOEING-747-53A2887-00 · 85 pages

© The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2016-8181; AD 2016-26-07 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

TextPartly OCR

Some pages are OCR from a scan. OCR can misread letters and numbers.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '1f0cd8aee6e2a5bba22b89726972f9575ba3b698d482164d7c770238de91aea6'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Show pages 25–36
Page 37OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT STA

280.

FLOORBEAM

TOP PANEL WEB

FORE AFT

STIFFENER

FORE AFT

STIFFENER

- BL 22 FORE AFT STIFFENER (1 INTERCOSTAL

TYPICAL CRACK LOCATION 1 CLIP POTENTIAL CRACK TYPICAL STA 280-STA 300. LBL 10 AND 22

LOCATION IN FORE AFT

STIFFENER

• INTERCOSTAL BL 10 22

TYPICAL U TOP PANEL 2454879 WEB FIGURE 1: LEFT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 2 OF 7) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING 747-53A2887 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 37 of 85

Page 38OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT ® CHORD 1 SIDE WALL

VERTICAL PANEL WEB BEAM

VERTICAL

BEAM CLIP

TYPICAL CRACKS

IN VERTICAL

BEAM WEB

TYPICAL

INSULATION

BLANKET

STANDOFF/TOOL

HOLE LOCATION

2) HORIZONTAL

STIFFENER

VERTICAL (

BEAM CLIP CHORD 1 STATIONS 260 THROUGH 320 (TYPICAL) D 2454881 FIGURE 1: LEFT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 3 OF 7) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING 747-53A2887 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 38 of 85

Page 39OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT

MAIN DECK FLOOR BEAM (AT STA 280, 300 AND 320 ONLY VERTICAL BEAM 2 S-40L S-41L INBD TYPICAL STATIONS 260 TO 320 A-A FIGURE 1: LEFT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 4 OF 7) Original Issue: December 02, 2015 PROPRIETARY - Copyright © Unpublished Export Controlled ECCN: 9E991 - BOEING 747-53A2887 Work - See page 1 for details. 39 of 85

Page 40OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT STA 280 300 320

12.0

12.0

3) LOWER CHORI FLOOR BEAN ® STRAP STA 280 300 320

2) BEAM OUTER VERTICAL CHORD

TYPICAL

VERTICAL BEAM

TYPICAL CRACK VERTICAL BEAM WEB ₴ VERTICAL BEAM (2

INNER CHORD LOOF (3 FAM LOWER CHORD 3 FLOOR BEAM 2454887 FIGURE 1: LEFT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 5 OF 7) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 40 of 85

The step numbers shown below agree with the numbers shown in the circle symbols in the figure.

More DataQtyIdentificationNameTaskStep

(a)--Fore Aft StiffenersInspect1

(b)--ClipsInspect

(c)--IntercostalInspect

(d)--Floor BeamInspect

(e)--Top Panel WebInspect

(f)--Vertical BeamInspect2

(f)--Vertical Beam WebInspect

(f)--Vertical Beam ChordInspect

(g)--Vertical Beam ClipsInspect

(h)--Horizontal StiffenersInspect

(i)--Main Deck Floor Beams Inspect3

(j)--Floor Beam Lower Chords Inspect

(k)--StrapsInspect

(a) Do a detailed inspection of the fore aft stiffeners, between Body Station (STA) 280 and STA 300, Left Buttock Line (LBL) 10 and LBL 22, common to the top panel. Inspect from the top side, around all fastener heads and in the stiffeners fillet radius, common to the horizontal flange attached to the nose wheel well top panel web.

(b) Do a detailed inspection of all attachments of the clips to the fore aft stiffeners.

(c) Do a detailed inspection of the intercostals in the area surrounding the connection to the clip and the fore aft stiffeners.

(d) Do a detailed inspection of the main deck floor beams in the area surrounding the connection to the fore aft stiffeners.

(e) Do a detailed inspection of the top panel web in the area surrounding the connection to the fore aft stiffeners.

(f) Do a detailed inspection of the full length of the vertical beams, vertical beam webs and vertical beam chords. Inspect both the forward and aft side of the beams. Inspect the joints between the vertical beams and the frames and between the vertical beams and the main deck floor beams.

(g) Do a detailed inspection of all attachments of the vertical beam clips to the vertical beams, from inside the fuselage.

(h) Do a detailed inspection of the horizontal stiffeners in the area surrounding the connection to the vertical beams.

(i) Do a detailed inspection of the main deck floor beams, 12 inches outboard of the vertical beam to 12 inches inboard of the vertical beam. Inspect both the forward and aft side of the beams.

FIGURE 1: LEFT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 6 OF 7) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: December 02, 2015 747-53A2887 41 of 85 BOEING SERVICE BULLETIN 747-53A2887

ALERTALERT

More DataQtyIdentificationNameTaskStep

(j) Do a detailed inspection of the floor beam lower chords, 12 inches outboard of the vertical beam to 12 inches inboard of the vertical beam. Inspect both the forward and aft side of the chord.

(k) Do a detailed inspection of the floor beam lower chords in the area around the ends of the reinforcing straps.

FIGURE 1: LEFT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 7 OF 7) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: December 02, 2015 747-53A2887 42 of 85 BOEING SERVICE BULLETIN 747-53A2887

ALERTALERT

Page 43OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT This Figure applies only to: Group 1-2, Configuration 1; Group 3, 5.

STA 260 STA 260 STA _ CANTED 340 280 STA 300 STA 340 32 - LBL 22

- LBL 10 -RBL 10 RBL 22 2455847 FIGURE 2: RIGHT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 1 OF 7) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING 747-53A2887 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 43 of 85

Page 44OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT STA 280, 300

FLOORBEAM

TOP PANEL WEB

FORE AFT

STIFFENER

FORE AFT

STIFFENER BL 22

FORE AFT

INTERCOSTAL STIFFENER

TYPICAL CRACK

BI LOCATION 10 TYPICAL STA 280-STA 300, POTENTIAL CRACK RBL 10 AND 22 LOCATION IN

FORE AFT STIFFENER

INTERCOSTAL 1 TOP PANEL 2455863 WEB FIGURE 2: RIGHT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 2 OF 7) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Page 45OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT CHORD

SIDE WALL

PANEL WEB

VERTICAL BEAM

2) VERTICAL

BEAM CLIP

TYPICAL CRACKS

IN VERTICAL

BEAM WEB

TYPICAL

INSULATION

BLANKET

STANDOFF/TOOL

HOLE LOCATION

HORIZONTAL

STIFFENER

2) VERTICAL

BEAM CLIF STATIONS 260 THROUGH 320 CHORD (TYPICAL FIGURE 2: RIGHT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 3 OF 7) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING 747-53A2887 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 45 of 85

Page 46OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT

MAIN DECK FLOOR BEAM (AT STA 230, 300 AND 320 ONLY)

2) VERTICAL BEAM S-39R S-40R S-41R INBD TYPICAL STATIONS 260 TO 320 2455880 A-A FIGURE 2: RIGHT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 4 OF 7) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING 747-53A2887 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 46 of 85

Page 47OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT STA 280 300 320

12.0

FLOOR BEAM

LOWER CHORD STRAP

VERTICAL BEAM OUTER 2 CHORD

TYPICAL BEAM VERTICAL

TYPICAL CRACK

VERTICAL

BEAM WEB

2) VERTICAL BEA INNER CHORI 3 BEAM FLOOR FLOOR BEAI 2455892 /LOWER CHOR FIGURE 2: RIGHT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 5 OF 7) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING 747-53A2887 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 47 of 85

The step numbers shown below agree with the numbers shown in the circle symbols in the figure.

More DataQtyIdentificationNameTaskStep

(a)--Fore Aft StiffenersInspect1

(b)--ClipsInspect

(c)--IntercostalInspect

(d)--Floor BeamInspect

(e)--Top Panel WebInspect

(f)--Vertical BeamInspect2

(f)--Vertical Beam WebInspect

(f)--Vertical Beam ChordInspect

(g)--Vertical Beam ClipsInspect

(h)--Horizontal StiffenersInspect

(i)--Main Deck Floor Beams Inspect3

(j)--Floor Beam Lower Chords Inspect

(k)--StrapsInspect

(a) Do a detailed inspection of the fore aft stiffeners, between Body Station (STA) 280 and STA 300, Right Buttock Line (RBL) 10 and RBL 22, common to the top panel. Inspect from the top side, around all fastener heads and in the stiffeners fillet radius, common to the horizontal flange attached to the nose wheel well top panel web.

(b) Do a detailed inspection of all attachments of the clips to the fore aft stiffeners.

(c) Do a detailed inspection of the intercostals in the area surrounding the connection to the clip and the fore aft stiffeners.

(d) Do a detailed inspection of the main deck floor beams in the area surrounding the connection to the fore aft stiffeners.

(e) Do a detailed inspection of the top panel web in the area surrounding the connection to the fore aft stiffeners.

(f) Do a detailed inspection of the full length of the vertical beams, vertical beam webs and vertical beam chords. Inspect both the forward and aft side of the beams. Inspect the joints between the vertical beams and the frames and between the vertical beams and the main deck floor beams.

(g) Do a detailed inspection of all attachments of the vertical beam clips to the vertical beams, from inside the fuselage.

(h) Do a detailed inspection of the horizontal stiffeners in the area surrounding the connection to the vertical beams.

(i) Do a detailed inspection of the main deck floor beams, 12 inches outboard of the vertical beam to 12 inches inboard of the vertical beam. Inspect both the forward and aft side of the beams.

FIGURE 2: RIGHT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 6 OF 7) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: December 02, 2015 747-53A2887 48 of 85 BOEING SERVICE BULLETIN 747-53A2887

ALERTALERT

Pages 49–60 of 85