The step numbers shown below agree with the numbers shown in the circle symbols in the figure.

More DataQtyIdentificationNameTaskStep

(a)--Fore Aft StiffenersInspect1

(b)--ClipsInspect

(c)--IntercostalInspect

(d)--Floor BeamInspect

(e)--Top Panel WebInspect

(f)--Vertical BeamInspect2

(f)--Vertical Beam WebInspect

(f)--Vertical Beam ChordInspect

(g)--Vertical Beam ClipsInspect

(h)--Horizontal StiffenersInspect

(i)--Main Deck Floor Beams Inspect3

(j)--Floor Beam Lower Chords Inspect

(a) Do a detailed inspection of the fore aft stiffeners, between Body Station (STA) 280 and STA 300, Right Buttock Line (RBL) 10 and RBL 22, common to the top panel. Inspect from the top side, around all fastener heads and in the stiffeners fillet radius, common to the horizontal flange attached to the nose wheel well top panel web.

(b) Do a detailed inspection of all attachments of the clips to the fore aft stiffeners.

(c) Do a detailed inspection of the intercostals in the area surrounding the connection to the clip and the fore aft stiffeners.

(d) Do a detailed inspection of the floor beams in the area surrounding the connection to the fore aft stiffeners.

(e) Do a detailed inspection of the top panel web in the area surrounding the connection to the fore aft stiffeners.

(f) Do a detailed inspection of the full length of the vertical beams, vertical beam webs and vertical beam chords. Inspect both the forward and aft side of the beams. Inspect the joints between the vertical beams and the frames and between the vertical beams and the floor beams.

(g) Do a detailed inspection of all attachments of the vertical beam clips to the vertical beams, from inside the fuselage.

(h) Do a detailed inspection of the horizontal stiffeners in the area surrounding the connection to the vertical beams.

(i) Do a detailed inspection of the main deck floor beams, 12 inches outboard of the vertical beam to 12 inches inboard of the vertical beam. Inspect both the forward and aft side of the beams.

(j) Do a detailed inspection of the floor beam lower chords, 12 inches outboard of the vertical beam to 12 inches inboard of the vertical beam. Inspect both the forward and aft side of the chord.

FIGURE 4: RIGHT SIDE NOSE WHEEL WELL BODY STRUCTURE - DETAILED INSPECTION (SHEET 6 OF 6) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: December 02, 2015 747-53A2887 61 of 85 BOEING SERVICE BULLETIN 747-53A2887

ALERTALERT

Page 62OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT This Figure applies only to: Group 1, 4.

STA 260 STA *STA CANTED STA 260 ¡ 280 340 RBL 22. STA 340 RBL 10 - LBL 10 - LBL 22 ~ 2454901 FIGURE 5: LEFT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB - SURFACE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 1 OF 3) Original Issue: December 02, 2015 PROPRIETARY - Copyright © Unpublished Export Controlled ECCN: 9E991 - BOEING 747-53A2887 Work - See page 1 for details. 62 of 85

Page 63OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887C

ALERT ALERT

VERTICAL BEAM WEB

VERTICAL

BEAM OUTER CHORD FLOOR BEAM

TYPICAL CRACK

INSPECTION AREA FLOOR BEAM

VERTICAL

BEAM OUTER CHORD

VERTICAL

BEAM WEB A-A FIGURE 5: LEFT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB - SURFACE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 2 OF 3) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING 747-53A2887 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 63 of 85

The step numbers shown below agree with the numbers shown in the circle symbols in the figure.

More DataQtyIdentificationNameTaskStep

(a)--Vertical Beam WebInspect1

(b)--Vertical Beam Outer Chord Inspect2

(a) Do a surface High Frequency Eddy Current (HFEC) inspection on the edge of the vertical beam web for any crack in accordance with 747 NDT Manual Part 6, Section 51-00-00, Procedure 4 or 23. Inspect from above the fastener common to the floor beam lower chord down to below the fastener, below the floor beam chord. Extend the inspection to the mid-point towards the next adjacent fastener.

Use a pencil probe with a diameter that is less than 0.08 inch (2 mm). The following probes are examples of probes that can be used:

1. MXTF-40, straight probe, 0.050 inch (1.27 mm) diameter. NDT Engineering Corp. (Olympus)

2. MXTF902-40B, right angle, 0.050 inch (1.27 mm) diameter. NDT Engineering Corp. (Olympus)

3. SPC/501/AI, right angle, 0.043 inch (1.09 mm) width, 0.5 inch (12.7 mm) drop. EC NDT Inc

(b) Do a surface HFEC inspection 360 degrees around the two fastener heads of the vertical beam outer chord for any crack in accordance with 747 NDT Manual Part 6, Section 53-30-19.

FIGURE 5: LEFT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB – SURFACE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 3 OF 3) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: December 02, 2015 747-53A2887 64 of 85 BOEING SERVICE BULLETIN 747-53A2887

ALERTALERT

Page 65OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT This Figure applies only to: Group 1, 4.

STA 260 STA 260 CANTED STA 340 STA 280 STA 300

- LBL 22

- LBL 10 — RBL 10

• RBL 22 2456017 FIGURE 6: RIGHT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB - SURFACE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 1 OF 3) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING 747-53A2887 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 65 of 85

Page 66OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT STA 280 300 320

VERTICAL

BEAM WEB CHORD FLOOR BEAM

TYPICAL CRACK

INSPECTION AREA FLOOR BEAM

VERTICAL

BEAM OUTER - CHORD

VERTICAL

BEAM WEB A-A 2456021 FIGURE 6: RIGHT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB - SURFACE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 2 OF 3) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished 747-53A2887 Work - See page 1 for details. 66 of 85

The step numbers shown below agree with the numbers shown in the circle symbols in the figure.

More DataQtyIdentificationNameTaskStep

(a)--Vertical Beam WebInspect1

(b)--Vertical Beam Outer Chord Inspect2

(a) Do a surface High Frequency Eddy Current (HFEC) inspection on the edge of the vertical beam web for any crack in accordance with 747 NDT Manual Part 6, Section 51-00-00, Procedure 4 or 23. Inspect from above the fastener common to the floor beam lower chord down to below the fastener, below the floor beam chord. Extend the inspection to the mid-point towards the next adjacent fastener.

Use a pencil probe with a diameter that is less than 0.08 inch (2 mm). The following probes are examples of probes that can be used:

1. MXTF-40, straight probe, 0.050 inch (1.27 mm) diameter. NDT Engineering Corp. (Olympus)

2. MXTF902-40B, right angle, 0.050 inch (1.27 mm) diameter. NDT Engineering Corp. (Olympus)

3. SPC/501/AI, right angle, 0.043 inch (1.09 mm) width, 0.5 inch (12.7 mm) drop. EC NDT Inc

(b) Do a surface HFEC inspection 360 degrees around the two fastener heads of the vertical beam outer chord for any crack in accordance with 747 NDT Manual Part 6, Section 53-30-19.

FIGURE 6: RIGHT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB – SURFACE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 3 OF 3) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: December 02, 2015 747-53A2887 67 of 85 BOEING SERVICE BULLETIN 747-53A2887

ALERTALERT

Page 68OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT This Figure applies only to: Group 1, 4.

STA 260 STA *STA CANTED STA 260 ¡ 280 340 RBL 22. STA 340 RBL 10 - LBL 10 - LBL 22 ~ 2454904 FIGURE 7: LEFT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB - OPEN HOLE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 1 OF 2) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 98 10 89

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep Refer to 747- 100/200/300 SRM 51-30-02 or 747-SP SRM 51-30-02 as an accepted procedure.

6-FastenersRemove1

(a)--Vertical Beam WebInspect2

(a)--Vertical Beam Outer Chord Inspect

(a) Do an open hole High Frequency Eddy Current (HFEC) inspection for any crack in accordance with 747 NDT Manual Part 6, Section 51-00-00, Procedure 1, Procedure 11 or Procedure 16.

FIGURE 7: LEFT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB – OPEN HOLE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: December 02, 2015 747-53A2887 69 of 85 BOEING SERVICE BULLETIN 747-53A2887

ALERTALERT

Page 70OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT This Figure applies only to: Group 1, 4.

STA 260 STA 260 CANTED

- LBL 20

- LBL 10

- RBL 10

- RBL 22 2456072 FIGURE 8: RIGHT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB - OPEN HOLE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 1 OF 2) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 98 10 0L

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep Refer to 747- 100/200/300 SRM 51-30-02 or 747-SP SRM 51-30-02 as an accepted procedure.

6-FastenersRemove1

(a)--Vertical Beam WebInspect2

(a)--Vertical Beam Outer Chord Inspect

(a) Do an open hole High Frequency Eddy Current (HFEC) inspection for any crack in accordance with 747 NDT Manual Part 6, Section 51-00-00, Procedure 1, Procedure 11 or Procedure 16.

FIGURE 8: RIGHT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB – OPEN HOLE HIGH

FREQUENCY EDDY CURRENT (HFEC) INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: December 02, 2015 747-53A2887 71 of 85 BOEING SERVICE BULLETIN 747-53A2887

ALERTALERT

Page 72OCROpen in PDF

BOEING SERVICE BULLETIN 747-53A2887

ALERT ALERT This Figure applies only to: Group 1.

STA 260 STA *STA CANTED STA 260 ¡ 280 340 RBL 22. STA 340 RBL 10 - LBL 10 - LBL 22 - FIGURE 9: LEFT SIDE STA 280-320 VERTICAL BEAM OUTER CHORD AND WEB - RIVET INSTALLATION (SHEET 1 OF 2) Original Issue: December 02, 2015 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished 747-53A2887 Work - See page 1 for details. 72 of 85

Pages 73–84 of 85