TextPartly OCR
Some pages are OCR from a scan. OCR can misread letters and numbers.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '1ee0b91c7b8b01f6eca20e0fdf364d1913a832123d289bef70747b36e512103c' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '1ee0b91c7b8b01f6eca20e0fdf364d1913a832123d289bef70747b36e512103c' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
The step numbers shown below agree with the numbers shown in the circle symbols in the figure.
More DataQtyIdentificationNameTaskStep
(a) (b)1STA 1440Aft Pressure Bulkhead Web Measure1
(c)1STA 1440Aft Pressure Bulkhead Web Inspect2
(c)1STA 1440Aft Pressure Bulkhead Web Inspect3
(c)1STA 1440Aft Pressure Bulkhead Web Inspect4
(c)1STA 1440Aft Pressure Bulkhead Web Inspect5
(c)1STA 1440Aft Pressure Bulkhead Web Inspect6
(a) Measure the depth and width of each oil canning area to determine if the oil canning is within Zone 1 or Zone 2 limits. Refer to view B-B and Zone 1 and Zone 2 limits Table 1.
(b) Apply the flexible metal strip to make depth and width measurements, by pressing the ends of the strip flush to the outside surface of the web only in areas outside the oil canning outer edge. Measure the maximum depth of the oil canning condition between the dome surface and the metal strip.
(c) Do a detailed inspection for any damage or any irregularity. Any damage can include, any sharp creases, any gouges, any crack, any deformation to a radial stiffener, circumferential tear strap, Y-chord or terminal fitting splice plate, or any damaged holes. Any irregularity can include, any loose or missing fasteners, any pressure leakage, any fasteners within 1.0 inch of any oil canning location or any oil canning location within 2.0 inch inches of any other oil canning location.
FIGURE 2: STA 1440 AFT PRESSURE BULKHEAD WEB - OIL CANNING ZONE DETERMINATION AND
DETAILED INSPECTION (SHEET 7 OF 7) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: September 15, 2016 A3543 37 of 52 BOEING SERVICE BULLETIN A3543
ALERTALERT
BOEING SERVICE BULLETIN А3543
ALERT ALERT
CIRCUMFERENTIAL
TEAR STRAPS
WEB LAP SPLICE RADIAL
STIFFENERS
AFT PRESSURE INSPECTION AREA VIEW LOOKING FORWARD BULKHEAD WEB 2506484 A-A FIGURE 3: STA 1440 AFT PRESSURE BULKHEAD WEB - DETAILED INSPECTION AND EDDY CURRENT
INSPECTION (SHEET 1 OF 4) Original Issue: September 15, 2016 PROPRIETARY - Copyright © Unpublished Export Controlled ECCN: 9E991 - BOEING A3543 Work - See page 1 for details. 38 of 52
BOEING SERVICE BULLETIN А3543
ALERT ALERT
RADIAL STIFFENER OIL CANNING
CIRCUMFERENTIAL
TEAR STRAP
RADIAL STIFFENER
TYPICAL OIL
CANNING TYPICAL WEB BAY AREA (5
WEB LAP SPLICE INSPECTION AREA • RADIAL STIFFENER
TYPICAL OIL CANNING
OUTER EDGE
ORIGINAL
CONTOUR AFT PRESSURE
BULKHEAD WEB RADIAL
STIFFENER
TYPICAL OIL
CANNING
WEB LAP SPLICE INSPECTION AREA B-B 2506490 FIGURE 3: STA 1440 AFT PRESSURE BULKHEAD WEB - DETAILED INSPECTION AND EDDY CURRENT
INSPECTION (SHEET 2 OF 4) Original Issue: September 15, 2016 Export Controlled ECCN: 9E991 - BOEING A3543 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 39 of 52
The step numbers shown below agree with the numbers shown in the circle symbols in the figure.
More DataQtyIdentificationNameTaskStep
(a)1STA 1440Aft Pressure Bulkhead Web Inspect1
(b)1STA 1440Aft Pressure Bulkhead Web Inspect2
(c)1STA 1440Aft Pressure Bulkhead Web Inspect3
(d)1STA 1440Aft Pressure Bulkhead Web Inspect4
(e)1STA 1440Aft Pressure Bulkhead Web Inspect5
(f)1STA 1440Aft Pressure Bulkhead Web Inspect6
(a) Do a detailed inspection for any crack on the STA 1440 aft pressure bulkhead web.
(b) Do a surface HFEC inspection for any crack of the web, from the aft side along each oil canning outer edge in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or Figure 23.
(c) Do a LFEC inspection for any crack of the forward web lap splice hidden fastener rows, from the aft side of the aft pressure bulkhead web at all fastener locations common to the outer edge of the web bay area in which the oil canning was found in accordance with 707, 720 NDT Manual Part 6, 53-10-07, Figure 18.
FIGURE 3: STA 1440 AFT PRESSURE BULKHEAD WEB - DETAILED INSPECTION AND EDDY CURRENT
INSPECTION (SHEET 3 OF 4) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: September 15, 2016 A3543 40 of 52 BOEING SERVICE BULLETIN A3543
ALERTALERT
More DataQtyIdentificationNameTaskStep
(d) Do a LFEC inspection for any crack of the web hidden underneath the circumferential tear straps, from the aft side of the aft pressure bulkhead web at all fastener locations common to the perimeter of the web bay area in which the oil canning was found in accordance with 707, 720 NDT Manual Part 6, 53-10-07, Figure 18.
(e) Do a surface HFEC inspection for any crack of the web common to the radial stiffener, from the aft side of the aft pressure bulkhead web at all fastener locations common to the outer edge of the web bay area in which the oil canning was found in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or Figure 23. Make sure to inspect 360 degrees around fasteners.
(f) Do a surface HFEC inspection for any crack of the web common to a web lap splice, from the aft side of the aft pressure bulkhead web at all fastener locations common to the outer edge of the web bay area in which the oil canning was found in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or Figure 23. Make sure to inspect 360 degrees around fasteners.
FIGURE 3: STA 1440 AFT PRESSURE BULKHEAD WEB - DETAILED INSPECTION AND EDDY CURRENT
INSPECTION (SHEET 4 OF 4) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: September 15, 2016 A3543 41 of 52 BOEING SERVICE BULLETIN A3543
ALERTALERT
BOEING SERVICE BULLETIN А3543
ALERT ALERT
Y CHORD
CIRCUMFERENTIAL
TEAR STRAPS
WEB LAP SPLICE RADIAL
STIFFENERS
AFT PRESSURE
VIEW LOOKING FORWARD BULKHEAD WEB
INSPECTION AREA A-A FIGURE 4: STA 1440 AFT PRESSURE BULKHEAD WEB - Y-CHORD - DETAILED INSPECTION AND EDDY
CURRENT INSPECTION (SHEET 1 OF 5) Original Issue: September 15, 2016 PROPRIETARY - Copyright © Unpublished Export Controlled ECCN: 9E991 - BOEING A3543 Work - See page 1 for details. 42 of 52
BOEING SERVICE BULLETIN А3543
ALERT ALERT
RADIAL STIFFENER C
TYPICAL OIL
CIRCUMFERENTIAL CANNING
TEAR STRAP
Y CHORD
6) TYPICAL WEB
RADIAL STIFFENER' BAY AREA
WEB LAP SPLICE
INSPECTION AREA
RADIAL STIFFENER STA 1440 SKIN
Y CHORD
AFT PRESSURE
BULKHEAD WEB FWD .00 / INSPECTION AREA B-B 2518712 FIGURE 4: STA 1440 AFT PRESSURE BULKHEAD WEB - Y-CHORD - DETAILED INSPECTION AND EDDY
CURRENT INSPECTION (SHEET 2 OF 5) Original Issue: September 15, 2016 Export Controlled ECCN: 9E991 - BOEING A3543 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 43 of 52
BOEING SERVICE BULLETIN А3543
ALERT ALERT ) TYPICAL OIL CANNING
OUTER EDGE
ORIGINAL
CONTOUR AFT PRESSURE
BULKHEAD WEB RADIAL
STIFFENER
TYPICAL OIL
CANNING
WEB LAP SPLICE C-C
INSPECTION AREA
3) TYPICAL OIL CANNING
OUTER EDGE
ORIGINAL
CONTOUR CIRCUMFERENTIAL
TEAR STRAP
AFT PRESSURE TYPICAL OIL
BULKHEAD WEB CANNING D-D INSPECTION AREA 2508283 FIGURE 4: STA 1440 AFT PRESSURE BULKHEAD WEB - Y-CHORD - DETAILED INSPECTION AND EDDY
CURRENT INSPECTION (SHEET 3 OF 5) Original Issue: September 15, 2016 PROPRIETARY - Copyright © Unpublished Export Controlled ECCN: 9E991 - BOEING A3543 Work - See page 1 for details. 44 of 52
The step numbers shown below agree with the numbers shown in the circle symbols in the figure.
More DataQtyIdentificationNameTaskStep
(a) (b) (c)1STA 1440Aft Pressure Bulkhead Web Inspect1
(d)1STA 1440Aft Pressure Bulkhead Web Inspect2
(e)1STA 1440Aft Pressure Bulkhead Web Inspect3
(f)1STA 1440Aft Pressure Bulkhead Web Inspect4
(g)1STA 1440Aft Pressure Bulkhead Web Inspect5
(h)1STA 1440Aft Pressure Bulkhead Web Inspect6
(i)1STA 1440Aft Pressure Bulkhead Web Inspect7
(a) Do a surface High Frequency Eddy Current (HFEC) inspection for any crack at the aft fastener row from the forward side of the bulkhead in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or
23. Make sure to inspect 360 degrees around the fastener. Do this inspection except where a radial stiffener overlaps the Y-chord at the perimeter of the web at the fastener locations or where production doublers overlap the web.
(b) Where a radial stiffener overlaps the Y-chord at the perimeter of the web at the fastener location, do a surface HFEC inspection for any crack of the web, along the edge of the radial stiffener adjacent to the fastener locations in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or 23. Make sure to inspect the web up to 1.0 inch on each side of the fastener row.
(c) Where production doublers overlap the web, do a surface HFEC inspection for any crack of the web, along the outer edge fastener row of the doubler in accordance with 707, 720 NDT Manual Part 6, 51-00- 00, Figure 4 or Figure 23.
(d) Do a detailed inspection for any crack of the web, from the aft side along each oil canning outer edge.
(e) Do a surface HFEC inspection for any crack of the web, from the aft side along each oil canning outer edge in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or Figure 23.
(f) Do a LFEC inspection for any crack of the forward web lap splice hidden fastener rows, from the aft side of the aft pressure bulkhead web at all fastener locations common to the outer edge of the web bay area in which the oil canning was found in accordance with 707, 720 NDT Manual Part 6, 53-10-07, Figure 18.
(g) Do a HFEC inspection for any crack of the web underneath the circumferential tear straps, from the forward side of the aft pressure bulkhead web at all fastener locations common to the perimeter of the web bay area in which the oil canning was found in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or Figure 23.
FIGURE 4: STA 1440 AFT PRESSURE BULKHEAD WEB - Y-CHORD - DETAILED INSPECTION AND EDDY
CURRENT INSPECTION (SHEET 4 OF 5) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: September 15, 2016 A3543 45 of 52 BOEING SERVICE BULLETIN A3543
ALERTALERT
More DataQtyIdentificationNameTaskStep
(h) Do a surface HFEC inspection for any crack of the web common to the radial stiffener, from the aft side of the aft pressure bulkhead web at all fastener locations common to the outer edge of the web bay area in which the oil canning was found in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or Figure 23. Make sure to inspect 360 degrees around fasteners.
(i) Do a surface HFEC inspection for any crack of the web common to a web lap splice, from the aft side of the aft pressure bulkhead web at all fastener locations common to the outer edge of the web bay area in which the oil canning was found in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or Figure 23. Make sure to inspect 360 degrees around fasteners.
FIGURE 4: STA 1440 AFT PRESSURE BULKHEAD WEB - Y-CHORD - DETAILED INSPECTION AND EDDY
CURRENT INSPECTION (SHEET 5 OF 5) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: September 15, 2016 A3543 46 of 52 BOEING SERVICE BULLETIN A3543
ALERTALERT
BOEING SERVICE BULLETIN A3543
ALERT ALERT 1 TYPICAL OIL CANNING
RADIAL STIFFENER (TYPICAL)
CIRCUMFERENTIAL
TEAR STRAPS
AFT PRESSURE
BULKHEAD WEB INSPECTION AREA TYPICAL AFT PRESSURE BULKHEAD (VIEW LOOKING AFT) 2508598 A-A FIGURE 5: STA 1440 AFT PRESSURE BULKHEAD WEB - HIGH FREQUENCY EDDY CURRENT (HFEC)
INSPECTION (SHEET 1 OF 2) Original Issue: September 15, 2016 Export Controlled ECCN: 9E991 - BOEING A3543 PROPRIETARY - Copyright © Unpublished Work - See page 1 for details. 47 of 52
The step numbers shown below agree with the numbers shown in the circle symbols in the figure.
More DataQtyIdentificationNameTaskStep
(a) (b)1STA 1440Aft Pressure Bulkhead Web Inspect1
(a) Do a surface High Frequency Eddy Current (HFEC) inspection from the forward side of the affected location for the crack location, length and orientation in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 4 or Figure 23.
(b) If access is not available to do a surface HFEC inspection, then remove the fasteners at the affected location and do an Open Hole Eddy Current inspection of the web at the affected location to find the crack location and orientation in accordance with 707, 720 NDT Manual Part 6, 51-00-00, Figure 16.
FIGURE 5: STA 1440 AFT PRESSURE BULKHEAD WEB - HIGH FREQUENCY EDDY CURRENT (HFEC)
INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: September 15, 2016 A3543 48 of 52 BOEING SERVICE BULLETIN A3543