5. ACCOMPLISHMENT INSTRUCTIONS A. GENERAL INFORMATION NOTE: 1. This is an Enhanced Required for Compliance document. There w ill be a separate Service Bulletin (SB) and a separate Requirements Bulletin (RB). If an RB is mandated by an Airworthiness Directive (AD), then all applicable requirements specified in the RB must be done. For the related SB, some locations are marked RC Start and RC End to identify the requirements that are restated from the RB. For the related SB, the areas between RC Start and RC End, including sub-steps and any figures identified between RC Start and RC End, must be done to comply with the AD.

Therefore, an Alternative Method of Compliance (AMOC) is required for any deviations to steps between RC Start and RC End, including substeps and identified figures.

For the related SB, the steps not between RC Start and RC End may be deviated from using accepted methods in accordance with the operator's maintenance or inspection program without obtaining approval of an AMOC; this is provided that the steps between RC Start and RC End, including sub-steps and identified figures, can still be done as specified, and the airplane can be put back in an airworthy condition.

Figures not required for compliance are omitted from the RB.

2. This is an Enhanced Required for Compliance document. The Boe ing processes used to create the Service Bulletin (SB) and the Requirements Bulletin (RB) ensure that the information between "RC Start" and "RC End" in the SB are identical to the information in the same sections (Compliance, Work Instructions...) of the RB which the SB refers to as the related document.

5. Unless shown differently, these dimensions and tolerances are used:

– Linear dimensions are in inches – Tolerance on linear dimensions, other than rivet and bolt edge margins, is plus or minus 0.03 inch.

– Tolerance on rivet and bolt edge margin is plus or minus 0.05 inch – Angular tolerance is plus or minus 2 degrees – Hole dimensions for standard solid rivets are in DC-10 Structu ral Repair Manual (SRM) Volume 2, Chapter 51.

– Torque Values:

— Values for structural fasteners are given in DC-10 Structural Repair Manual (SRM) Volume 2, Chapter 51.

— Values for airframe maintenance tasks are included in Chapter 20 of DC-10 Aircraft Maintenance Manual (AMM).

— Values for electrical maintenance tasks are included in Chapte r 20 of Standard Wiring Practices Manual (SWPM).

— Values for engine maintenance tasks are included in Chapter 70 of DC-10 Aircraft Maintenance Manual (AMM).

— Non-standard torque values for maintenance tasks are included in the applicable installation step.

Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 13 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

7. A Detailed Inspection is defined as: An intensive examination of a specific item, installation or assembly to detect damage, failure or irregularity. This could include tactile assessment in which a component or assembly can be checked for tightness/security. Available lighting is normally supplemented with a direct source of good lighting at an intensity deemed appropriate. Inspection aids such as mirrors and magnifying lenses may be necessary. Surface cleaning and elaborate access procedures may be required.

8. A General Visual Inspection is defined as: A visual examinati on of an interior or exterior area, installation or assembly to detect obvious damage, failure or irregularity.

This level of inspection is made from within touching distance unless otherwise specified. A mirror may be necessary to enhance visual access to all exposed surfaces in the inspection area. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight or drop-light and may require removal or opening of access panels or doors. Stands, ladders or platforms may be required to gain proximity to the area being checked.

9. These work instructions refer to procedures included in other Boeing documents.

When the words "refer to" are used and the operator has an accepted alternative procedure, the accepted alternative procedure can be used. When the words "in accordance with" are included in the instruction, the procedure in the Boeing document must be used.

10. If it is necessary to remove more parts for access, you can remove those parts. If you can get access without removing identified parts, it is not necessary to remove all of the identified parts. Jacking and shoring limitations must be observed.

11. When more than one OPTION is given for a CONDITION, do only one of the OPTION numbers. When more than one ACTION is given for a CONDITION or an OPTION, do all of the ACTION numbers for that CONDITION or OPTION.

12. The compliance times for the actions in WORK INSTRUCTIONS ar e in Compliance.

B. WORK INSTRUCTIONS Actions Required for Compliance

1. Requirements Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 14 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Group 1:

Table 1: ETHF Inspection of the Overwing Floor Beams and Supports, Left and Right Sides Refer to the listed procedures in SB DC10-53A184 Original Issue or later approved revisions as an accepted procedure Method of ComplianceActionCondition Do PART 1: GET ACCESS FIGURE 1Do a General Visual Inspection of the overwing floor beams for any repair.

ALL AIRPLANES -FIGURE 2 Do PART 2:

CLOSE ACCESS -CONDITION 1 (ACTION 1):

Contact The Boeing Company for alternative inspection(s) to Requirements Bulletin DC10-53A184 RB, incorporate the inspection(s) into the maintenance programs and do the inspection(s) at the times specified by Boeing.

CONDITION 1:

ANY REPAIR FOUND Do PART 1: GET ACCESS -CONDITION 1 (ACTION 2):

Do ETHF Inspections of the overwing floor beams and supports at any unrepaired areas, for any crack.

-FIGURE 3 -FIGURE 4 -FIGURE 5 -FIGURE 6 Do PART 2:

CLOSE ACCESS -CONDITION 1.1 (ACTION

1): Contact The Boeing Company for repair instructions and do the repair.

CONDITION 1.1: ANY

CRACK FOUND Do PART 1: GET ACCESS -CONDITION 1.1 (ACTION

2): Repeat ETHF Inspections of the overwing floor beams and supports at any unrepaired areas, for any crack.

(a) -FIGURE 3 -FIGURE 4 -FIGURE 5 -FIGURE 6 Do PART 2:

CLOSE ACCESS - Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 15 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Group 1:

Table 1: ETHF Inspection of the Overwing Floor Beams and Supports, Left and Right Sides Refer to the listed procedures in SB DC10-53A184 Original Issue or later approved revisions as an accepted procedure Method of ComplianceActionCondition Do PART 2:

CLOSE ACCESS -Repeat ETHF Inspections of the overwing floor beams and supports at any unrepaired areas, for any crack.

(a) CONDITION 1.2: NO

CRACK FOUND Do PART 1: GET ACCESS - -FIGURE 3 -FIGURE 4 -FIGURE 5 -FIGURE 6 Do PART 1: GET ACCESS -Do ETHF inspections of the overwing floor beams and supports for any crack.

CONDITION 2:

NO REPAIR FOUND -FIGURE 3 -FIGURE 4 -FIGURE 5 -FIGURE 6 Do PART 2:

CLOSE ACCESS -CONDITION 2.1 (ACTION

1): Contact The Boeing Company for repair instructions and do the repair.

CONDITION 2.1: ANY

CRACK FOUND Do PART 1: GET ACCESS -CONDITION 2.1 (ACTION

2): Repeat ETHF Inspections of the overwing floor beams and supports for any crack.

(a) -FIGURE 3 -FIGURE 4 -FIGURE 5 -FIGURE 6 Do PART 2:

CLOSE ACCESS - Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 16 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Group 1:

Table 1: ETHF Inspection of the Overwing Floor Beams and Supports, Left and Right Sides Refer to the listed procedures in SB DC10-53A184 Original Issue or later approved revisions as an accepted procedure Method of ComplianceActionCondition Do PART 2:

CLOSE ACCESS -Repeat ETHF inspections of the overwing floor beams and supports for any crack.

(a) CONDITION 2.2: NO

CRACK FOUND Do PART 1: GET ACCESS - -FIGURE 3 -FIGURE 4 -FIGURE 5 -FIGURE 6

(a) It is not required to do the inspections in Requirements Bul letin DC10-53A184 RB in areas where a repair covers the affected inspection zone provided that:

1. The repair is the corrective action to the crack condition identified while performing Requirements Bulletin DC10-53A184 RB and installed after the original issue date of Requirements Bulletin DC10- 53A184 RB, AND

2. The installed repair was approved by the Boeing Organization Designation Authorization (ODA) via a FAA Form 8100-9.

Group 2:

Table 2: ETHF Inspection of the Overwing Floor Beams and Detailed Inspection of the Overwing Floor Beam Supports, Left and Right Sides Refer to the listed procedures in SB DC10-53A184 Original Issue or later approved revisions as an accepted procedure Method of ComplianceActionCondition Do PART 1: GET ACCESS FIGURE 1Do a General Visual Inspection of the overwing floor beams for any repair.

ALL AIRPLANES -FIGURE 2 Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 17 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Group 2:

Table 2: ETHF Inspection of the Overwing Floor Beams and Detailed Inspection of the Overwing Floor Beam Supports, Left and Right Sides Refer to the listed procedures in SB DC10-53A184 Original Issue or later approved revisions as an accepted procedure Method of ComplianceActionCondition Do PART 2:

CLOSE ACCESS -CONDITION 3 (ACTION 1):

Contact The Boeing Company for alternative inspection(s) to Requirements Bulletin DC10-53A184 RB, incorporate the inspection(s) into the maintenance programs and do the inspection(s) at the times specified by Boeing.

CONDITION 3:

ANY REPAIR FOUND Do PART 1: GET ACCESS -CONDITION 3 (ACTION 2):

Do Detailed Inspections of the overwing floor beam supports and ETHF Inspections of the overwing floor beams at any unrepaired areas, for any crack.

-FIGURE 3 -FIGURE 4 -FIGURE 7 -FIGURE 8 Do PART 2:

CLOSE ACCESS -CONDITION 3.1 (ACTION

1): Contact The Boeing Company for repair instructions and do the repair.

CONDITION 3.1: ANY

CRACK FOUND Do PART 1: GET ACCESS -CONDITION 3.1 ACTION 2:

Repeat Detailed Inspections of the overwing floor beam supports and ETHF Inspections of the overwing floor beams at any unrepaired areas, for any crack. (a) -FIGURE 3 -FIGURE 4 -FIGURE 7 -FIGURE 8 Do PART 2:

CLOSE ACCESS - Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 18 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Group 2:

Table 2: ETHF Inspection of the Overwing Floor Beams and Detailed Inspection of the Overwing Floor Beam Supports, Left and Right Sides Refer to the listed procedures in SB DC10-53A184 Original Issue or later approved revisions as an accepted procedure Method of ComplianceActionCondition Do PART 2:

CLOSE ACCESS -Repeat Detailed Inspections of the overwing floor beam supports and ETHF Inspections of the overwing floor beams at any unrepaired areas, for any crack. (a) CONDITION 3.2: NO

CRACK FOUND Do PART 1: GET ACCESS - -FIGURE 3 -FIGURE 4 -FIGURE 7 -FIGURE 8 Do PART 1: GET ACCESS -Do Detailed Inspections of the overwing floor beam supports and ETHF Inspections of the overwing floor beams for any crack.

CONDITION 4:

NO REPAIR FOUND -FIGURE 3 -FIGURE 4 -FIGURE 7 -FIGURE 8 Do PART 2:

CLOSE ACCESS -CONDITION 4.1 (ACTION

1): Contact The Boeing Company for repair instructions and do the repair.

CONDITION 4.1: ANY

CRACK FOUND Do PART 1: GET ACCESS -CONDITION 4.1 (ACTION

2): Repeat Detailed Inspections of the overwing floor beam supports and ETHF Inspections of the overwing floor beams for any crack.

(a) -FIGURE 3 -FIGURE 4 -FIGURE 7 -FIGURE 8 Do PART 2:

CLOSE ACCESS - Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 19 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Group 2:

Table 2: ETHF Inspection of the Overwing Floor Beams and Detailed Inspection of the Overwing Floor Beam Supports, Left and Right Sides Refer to the listed procedures in SB DC10-53A184 Original Issue or later approved revisions as an accepted procedure Method of ComplianceActionCondition Do PART 2:

CLOSE ACCESS -Repeat Detailed Inspections of the overwing floor beam supports and ETHF Inspections of the overwing floor beams for any crack. (a) CONDITION 4.2: NO

CRACK FOUND Do PART 1: GET ACCESS - -FIGURE 3 -FIGURE 4 -FIGURE 7 -FIGURE 8

(a) It is not required to do the inspections in Requirements Bul letin DC10-53A184 RB in areas where a repair covers the affected inspection zone provided that:

1. The repair is the corrective action to the crack condition identified while performing Requirements Bulletin DC10-53A184 RB and installed after the original issue date of Requirements Bulletin DC10- 53A184 RB, AND

2. The installed repair was approved by the Boeing Organization Designation Authorization (ODA) via a FAA Form 8100-9.

Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 20 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Page 21OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT STA Y = 1305 STA Y = 1256 STA Y = 1305 STA Y = 1293 SIA Y = 1275 STA Y = 1256 STA X = 90 GENERAL VISUAL INSPECTION STA FWD 2884447 X = 116 FIGURE 1: LEFT SIDE - GENERAL VISUAL INSPECTION OF THE OVERWING FLOOR BEAMS (SHEET 1 OF 2) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 Copyright © Unpublished DC10-53A184 RB Work - See page 1 for details. 21 of 62

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)--FLOOR BEAMSInspect1

(a) Do a General Visual Inspection for any repair of the floor beams from STA X=90 to X=116 at STA Y=1256, 1275, 1293 and 1305.

FIGURE 1: LEFT SIDE - GENERAL VISUAL INSPECTION OF THE OVERWING FLOOR BEAMS (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 22 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Page 23OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT STA Y = 1305 STA Y = 1256 STA Y = 1305 STA Y = 1293 STA · = 1275 STA Y = 1256 STA × = 90 GENERAL VISUAL INSPECTION X = 116 STA FWD 2902559 FIGURE 2: RIGHT SIDE - GENERAL VISUAL INSPECTION OF THE OVERWING FLOOR BEAMS (SHEET 1 OF 2) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 Copyright © Unpublished DC10-53A184 RB Work - See page 1 for details. 23 of 62

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)--FLOOR BEAMSInspect1

(a) Do a General Visual Inspection for any repair of the floor beams from STA X=90 to X=116 at STA Y=1256, 1275, 1293 and 1305.

FIGURE 2: RIGHT SIDE - GENERAL VISUAL INSPECTION OF THE OVERWING FLOOR BEAMS (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 24 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Pages 25–36 of 62