Copy · DC10-53A184-RB 00-- · 62 pages

© The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2020-0779; AD 2020-22-15 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

TextPartly OCR

Some pages are OCR from a scan. OCR can misread letters and numbers.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '2f032f367b02d551303d01a4b75864c2b20ce9d2d7f7d223fc8b4980094d301b'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Show pages 13–24
Page 25OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT STA Y = 1305 STA Y = 1256 STA Y = 1305 STA Y = 1293 STA Y = 1275 STA Y = 1256 A, E STA X = 90 STA FWD 2902575 X = 116 FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 1 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 25 of 62

Page 26OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT

- •

FLOOR BEAM

TYPICAL CRACK STA X = 107

FLOOR SUPPORT TYPICAL TYPICAL CRACK LOOKING AFT FLOOR BEAM (TYPICAL) A-A CRACK

TYPICAL CRACK TYPICAL CRACK FASTENER PATTERN MAY VARY ETHF INSPECTION NOTE: 2884507 FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 2 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 26 of 62

Page 27OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT STA X = 116

TYPICAL CRACK

LOOKING DOWN FLOOR BEAM (TYPICAL) B-B

TYPICAL CRACK

FASTENER PATTERN MAY VARY ETHF INSPECTION NOTE: 2884664 FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 3 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 27 of 62

Page 28OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT

- 04

TYPICAL CRACK

TYPICAL CRACK

TYPICAL CRACK STA X = 107 GENI

TYPICAL CRACK

TYPICAL CRACK FASTENER PATTERN MAY VARY ETHF INSPECTION STA X = 116 NOTE: 2884681 FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 4 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 28 of 62

Page 29OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT

TYPICAL CRACK TYPICAL CRACK FLOOR BEAM INBD a-a

FRAME FASTENER PATTERN MAY VARY ETHF INSPECTION NOTE: 2901807 FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 5 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 29 of 62

Page 30OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT

FLOOR BEAM STA X = 107

FLOOR SUPPORT LOOKING AFT FLOOR BEAM TYPICAL E-E

TYPICAL CRACK

PROBE FASTENER PATTERN MAY VARY ETHF INSPECTION NOTE: 2884996 FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 6 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 30 of 62

Page 31OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT FWD

FLOOR BEAM STA Y=1275 SHOWN STA Y=1293 SIMILAR F-F

ATTACHED ANGLE

ETHF INSPECTION

FLOOR BEAM MODIFICATION STA Y=1275 SHOWN STA Y=1293 SIMILAR F-F 2885033 FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 7 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 31 of 62

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)--Floor Beam: Around Fastener Holes Inspect1

(b)--Floor Beam: Web and Flange Surfaces Inspect2

(c)--Floor Beam: Flange Edges Inspect3 FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 8 OF 10) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 32 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

More DataQtyIdentificationNameTaskStep

(a) Do an ETHF inspection of the overwing floor beam web and the upper and lower flanges at each fastener location for any crack from STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1. Inspect the beam upper flange on both surfaces. Inspect the beam web on either face, as applicable to avoid obstructions. Inspect the beam lower flange on the upper or lower surface, as needed to avoid obstructions.

1. Calibrate instrument on the N3 notch, in accordance with in F igure 2 of the NDTSPM procedure.

2. Utilize calibration Scan Method K, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, use Scan Method 44, in accordance with Figure 4, Sheets 1 and 2, of the NDTSPM procedure.

4. Scan around all fastener holes on the web and flange surfaces of the four floor beams, as noted above. Structure attached to the floor beams does not have to be detached from the floor beams.

– From STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 13 05.

(b) Do an ETHF inspection of the flat surfaces of the floor beam flanges and webs for any crack from STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.

1. Calibrate instrument on the N5 notch, in accordance with Figu re 2 of the NDTSPM procedure.

2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, use Scan Method 61, in accordance with Figure 6, Sheets 1 and 2, of the NDTSPM procedure.

4. Scan all web and flange surfaces of the four floor beams. Str ucture attached to the floor beams does not have to be detached from the floor beams.

– From STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 13 05.

– Scan between fastener rows, and between holes and edges. Where no fasteners exist, scan incrementally, approximately 1/4 inch apart.

– Scan angles which compose the floor beam (not repair angles).

FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 9 OF 10) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 33 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

More DataQtyIdentificationNameTaskStep

(c) Do an ETHF inspection of the floor beam flange edges for any crack from STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.

1. Calibrate instrument using the N5 notch, in accordance with F igure 2 of the NDTSPM procedure.

2. Utilize Scan Method J, in accordance with Figure 3, Sheet 1 o f the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, use Scan Method 71 in accordance with Figure 7, S heets 1 and 2 of the NDTSPM procedure.

4. Scan along all edges of the four floor beams (and attached an gle, if present). Structure attached to the floor beams does not have to be detached from the floor beams.

– From STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 13 05.

FIGURE 3: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 10 OF 10) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 34 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Page 35OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT STA Y = 1305 STA Y = 1256 STA Y = 1305 STA Y = 1293 STA Y= 1275 A, E Y = 1256 STA STA X = 90 STA FWD 2902595 X = 116 FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 1 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 35 of 62

Page 36OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT STA X = 90

TYPICAL CRACK

FLOOR SUPPORT TYPICAL CRACK

LOOKING AFT FLOOR BEAM (TYPICAL) A-A STA X = 107

TYPICAL CRACK

STA FLOOR BEAM FASTENER PATTERN MAY VARY ETHE INSPECTION NOTE: 2902600 FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 2 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 36 of 62

Pages 37–48 of 62