Copy · DC10-53A184-RB 00-- · 62 pages

© The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2020-0779; AD 2020-22-15 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

TextPartly OCR

Some pages are OCR from a scan. OCR can misread letters and numbers.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '2f032f367b02d551303d01a4b75864c2b20ce9d2d7f7d223fc8b4980094d301b'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Show pages 37–48
Page 49OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT

• FILLER

• FILLET

•TYPICAL CRACK 3 INCHES

- TYPICAL CRACK -WD Y = 1305 SHOWN, Y = 1256, Y = 1275 AND Y = 1293 SIMILAR ETHF INSPECTION D-D 2902158 FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING _ FLOOR BEAM SUPPORTS (SHEET 5 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 Copyright © Unpublished DC10-53A184 RB Work - See page 1 for details. 49 of 62

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)--Floor Beam Support:

Flange Surface Inspect1

(b)--Floor Beam Support:

Flange Edges Inspect2

(a) Do an ETHF inspection of the floor beam support flange flat surfaces for any crack for STA X=81 at STA Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.

1. Calibrate the instrument on the N5 notch, in accordance with Figure 2 of the NDTSPM procedure.

2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, use Scan Method 61, in accordance with Figure 6, Sheet 2 of the NDTSPM.

4. Scan both faces of each of the four flanges of the floor beam supports.

– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from the bottom of the floor beam down a minimum of 3 inches.

– Thoroughly scan the fillet radius at the flange thickness chan ge.

(b) Do an ETHF inspection of the edges of the four flanges of the supports for any crack in accordance with NDTSPM Part 06-10-01.001.

1. Calibrate instrument using the N9 notch, in accordance with F igure 2 of the NDTSPM procedure.

2. Utilize calibration Scan Method H, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, scan along the edge of each of the four flanges o f the floor beam supports, to a minimum of 3 inches below the floor beam, using Scan Method 71 in accordance with Figure 7, Sheet 1 and 2 of the NDTSPM.

– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from the bottom of the floor beam down a minimum of 3 inches.

FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 6 OF 6) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 50 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Page 51OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT This Figure applies only to: Group 1.

STA Y = 1305 10 STA Y = 1256 _ STA STA STA STA STA STA Y = 1231 Y = 1256 Y = 1275 Y = 1293 Y = 1305 Y = 1321 STA 81 2902693 FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 1 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 51 of 62

Page 52OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT STA X = 107 X = 81.0 3 INCHES

TYPICAL TYPICAL

CRACK CRACK

ETHF INSPECTION

LOOKING FORWARD

FLOOR BEAM SUPPORT Y = 1305 SHOWN Y = 1256, Y = 1275, AND Y = 1293 SIMILAR 2902695 A-A FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 2 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 52 of 62

Page 53OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT

FILLER- 3 INCHES

TYPICAL CRACK

TYPICAL CRACK

ETHF INSPECTION VIEW LOOKING INBOARD AT X = 81 Y = 1305 SHOWN, Y = 1256, Y = 1275 AND Y = 1293 SIMILAR B-B 2902696 FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 3 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 53 of 62

FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 4 OF 6) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 54 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Page 55OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT FILLER

TYPICAL CRACK FILLET• 3 INCHES

TYPICAL CRACK FWD Y = 1305 SHOWN ETHF INSPECTION Y = 1256, Y = 1275 AND Y = 1293 SIMILAR D-D 2902707 FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 5 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 55 of 62

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)--Floor Beam Support:

Flange Surface Inspect1

(b)--Floor Beam Support:

Flange Edges Inspect2

(a) Do an ETHF inspection of the floor beam support flange flat surfaces for any crack for STA X=81 at STA Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.

1. Calibrate instrument the N5 notch, in accordance with Figure 2 of the NDTSPM procedure.

2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, use scan Method 61, in accordance with Figure 6, Sheet 2 of the NDTSPM.

4. Scan both faces of each of the four flanges of the floor beam supports.

– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from the bottom of the floor beam down a minimum of 3 inches.

– Thoroughly scan the fillet radius at the flange thickness chan ge.

(b) Do an ETHF inspection of the edges of the four flanges of th e supports for any crack for STA X=81 for STA Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.

1. Calibrate instrument using the N9 notch, in accordance with F igure 2 of the NDTSPM procedure.

2. Utilize calibration Scan Method H, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, scan along the edge of each of the four flanges o f the floor beam supports, to a minimum of 3 inches below the floor beam, using Scan Method 71 in accordance with Figure 7, Sheet 1 and 2 of the NDTSPM.

– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from the bottom of the floor beam down a minimum of 3 inches.

FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 6 OF 6) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 56 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Page 57OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT This Figure applies only to: Group 2.

STA Y = 1305 STA Y = 1256 _ STA STA STA STA STA STA Y = 1231 Y = 1256 Y = 1275 Y = 1293 Y = 1305 Y = 1321 STA 81 2885151 FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS (SHEET 1 OF 3) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 57 of 62

Page 58OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT

STA STA X = 81 X = 107 STA Y = 1305 SHOWN Y = 1256 Y = 1275 Y = 1293

SIMILAR B

LOOKING FORWARD

FLOOR BEAM SUPPORT Y = 1305 SHOWN Y = 1256, Y = 1275 AND Y = 1293 SIMILAR A-A

TYPICAL B-B DETAILED INSPECTION 2885392 FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS (SHEET 2 OF 3) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Work - See page 1 for details. Copyright © Unpublished 58 of 62

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)--Floor Beam Support:

Rods and Rod Ends Inspect1

(a) Do a Detailed Inspection of the floor beam support rods, rod ends and attached pieces, for any crack for STA X=81 at STA Y=1256, 1275, 1293 and 1305.

FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS (SHEET 3 OF 3) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 59 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Page 60OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT This Figure applies only to: Group 2.

STA Y = 1305 STA Y = 1256

STA STA STA STA STA STA Y = 1231 1256 Y = 1275 Y = 1293 Y = 1305 Y = 1321 STA 81 2902694 FIGURE 8: RIGHT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS (SHEET 1 OF 3) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Work - See page 1 for details. Copyright © Unpublished 60 of 62

Pages 61–62 of 62