duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '2f032f367b02d551303d01a4b75864c2b20ce9d2d7f7d223fc8b4980094d301b' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '2f032f367b02d551303d01a4b75864c2b20ce9d2d7f7d223fc8b4980094d301b' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
REQUIREMENTS BULLETIN DC10-53A184
ALERT ALERT
• FILLER
• FILLET
•TYPICAL CRACK 3 INCHES
- TYPICAL CRACK -WD Y = 1305 SHOWN, Y = 1256, Y = 1275 AND Y = 1293 SIMILAR ETHF INSPECTION D-D 2902158 FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING _ FLOOR BEAM SUPPORTS (SHEET 5 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 Copyright © Unpublished DC10-53A184 RB Work - See page 1 for details. 49 of 62
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Flange Surface Inspect1
(b)--Floor Beam Support:
Flange Edges Inspect2
(a) Do an ETHF inspection of the floor beam support flange flat surfaces for any crack for STA X=81 at STA Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.
1. Calibrate the instrument on the N5 notch, in accordance with Figure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.
3. To inspect, use Scan Method 61, in accordance with Figure 6, Sheet 2 of the NDTSPM.
4. Scan both faces of each of the four flanges of the floor beam supports.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from the bottom of the floor beam down a minimum of 3 inches.
– Thoroughly scan the fillet radius at the flange thickness chan ge.
(b) Do an ETHF inspection of the edges of the four flanges of the supports for any crack in accordance with NDTSPM Part 06-10-01.001.
1. Calibrate instrument using the N9 notch, in accordance with F igure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method H, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.
3. To inspect, scan along the edge of each of the four flanges o f the floor beam supports, to a minimum of 3 inches below the floor beam, using Scan Method 71 in accordance with Figure 7, Sheet 1 and 2 of the NDTSPM.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from the bottom of the floor beam down a minimum of 3 inches.
FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS (SHEET 6 OF 6) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: February 06, 2020 DC10-53A184 RB 50 of 62 REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT
REQUIREMENTS BULLETIN DC10-53A184
ALERT ALERT This Figure applies only to: Group 1.
STA Y = 1305 10 STA Y = 1256 _ STA STA STA STA STA STA Y = 1231 Y = 1256 Y = 1275 Y = 1293 Y = 1305 Y = 1321 STA 81 2902693 FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS (SHEET 1 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 51 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERT ALERT STA X = 107 X = 81.0 3 INCHES
TYPICAL TYPICAL
CRACK CRACK
ETHF INSPECTION
LOOKING FORWARD
FLOOR BEAM SUPPORT Y = 1305 SHOWN Y = 1256, Y = 1275, AND Y = 1293 SIMILAR 2902695 A-A FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS (SHEET 2 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 52 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERT ALERT
FILLER- 3 INCHES
TYPICAL CRACK
TYPICAL CRACK
ETHF INSPECTION VIEW LOOKING INBOARD AT X = 81 Y = 1305 SHOWN, Y = 1256, Y = 1275 AND Y = 1293 SIMILAR B-B 2902696 FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS (SHEET 3 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 53 of 62
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS (SHEET 4 OF 6) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: February 06, 2020 DC10-53A184 RB 54 of 62 REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT
REQUIREMENTS BULLETIN DC10-53A184
ALERT ALERT FILLER
TYPICAL CRACK FILLET• 3 INCHES
TYPICAL CRACK FWD Y = 1305 SHOWN ETHF INSPECTION Y = 1256, Y = 1275 AND Y = 1293 SIMILAR D-D 2902707 FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS (SHEET 5 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 55 of 62
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Flange Surface Inspect1
(b)--Floor Beam Support:
Flange Edges Inspect2
(a) Do an ETHF inspection of the floor beam support flange flat surfaces for any crack for STA X=81 at STA Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.
1. Calibrate instrument the N5 notch, in accordance with Figure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.
3. To inspect, use scan Method 61, in accordance with Figure 6, Sheet 2 of the NDTSPM.
4. Scan both faces of each of the four flanges of the floor beam supports.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from the bottom of the floor beam down a minimum of 3 inches.
– Thoroughly scan the fillet radius at the flange thickness chan ge.
(b) Do an ETHF inspection of the edges of the four flanges of th e supports for any crack for STA X=81 for STA Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.
1. Calibrate instrument using the N9 notch, in accordance with F igure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method H, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.
3. To inspect, scan along the edge of each of the four flanges o f the floor beam supports, to a minimum of 3 inches below the floor beam, using Scan Method 71 in accordance with Figure 7, Sheet 1 and 2 of the NDTSPM.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from the bottom of the floor beam down a minimum of 3 inches.
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS (SHEET 6 OF 6) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: February 06, 2020 DC10-53A184 RB 56 of 62 REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT
REQUIREMENTS BULLETIN DC10-53A184
ALERT ALERT This Figure applies only to: Group 2.
STA Y = 1305 STA Y = 1256 _ STA STA STA STA STA STA Y = 1231 Y = 1256 Y = 1275 Y = 1293 Y = 1305 Y = 1321 STA 81 2885151 FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS (SHEET 1 OF 3) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 57 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERT ALERT
STA STA X = 81 X = 107 STA Y = 1305 SHOWN Y = 1256 Y = 1275 Y = 1293
SIMILAR B
LOOKING FORWARD
FLOOR BEAM SUPPORT Y = 1305 SHOWN Y = 1256, Y = 1275 AND Y = 1293 SIMILAR A-A
TYPICAL B-B DETAILED INSPECTION 2885392 FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS (SHEET 2 OF 3) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Work - See page 1 for details. Copyright © Unpublished 58 of 62
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Rods and Rod Ends Inspect1
(a) Do a Detailed Inspection of the floor beam support rods, rod ends and attached pieces, for any crack for STA X=81 at STA Y=1256, 1275, 1293 and 1305.
FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS (SHEET 3 OF 3) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: February 06, 2020 DC10-53A184 RB 59 of 62 REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT
REQUIREMENTS BULLETIN DC10-53A184
ALERT ALERT This Figure applies only to: Group 2.
STA Y = 1305 STA Y = 1256
STA STA STA STA STA STA Y = 1231 1256 Y = 1275 Y = 1293 Y = 1305 Y = 1321 STA 81 2902694 FIGURE 8: RIGHT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS (SHEET 1 OF 3) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Work - See page 1 for details. Copyright © Unpublished 60 of 62