Copy · DC10-53A184-RB 00-- · 62 pages

© The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2020-0779; AD 2020-22-15 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

TextPartly OCR

Some pages are OCR from a scan. OCR can misread letters and numbers.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '2f032f367b02d551303d01a4b75864c2b20ce9d2d7f7d223fc8b4980094d301b'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Show pages 25–36
Page 37OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT →0

TYPICAL CRACK FWD

LOOKING DOWN FLOOR BEAM (TYPICAL) B-B × = TOT

TYPICAL CRACK FASTENER PATTERN MAY VARY ETHF INSPECTION NOTE: 2902601 FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 3 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 37 of 62

Page 38OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT × - T76

TYPICAL CRACK STA X = 107 GSNI C-C

TYPICAL CRACK

FASTENER PATTERN MAY VARY ETHF INSPECTION × = NOTE: 2902627 FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 4 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 38 of 62

Page 39OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT

TYPICAL CRACK FLOOR BEAM LOOKING UP FLOOR BEAM (TYPICAL) D-D

TYPICAL CRACK

FASTENER PATTERN MAY VARY ETHF INSPECTION NOTE: 2902637 FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 5 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 39 of 62

Page 40OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT

TYPICAL CRACK

FLOOR SUPPORT TYPICAL CRACK LOOKING AFT FLOOR BEAM TYPICAL E-E STA X = 107

TYPICAL CRACK

FLOOR BEAM FASTENER PATTERN MAY VARY ETHF INSPECTION NOTE: 2902640 FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 6 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 40 of 62

Page 41OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT FWD

- LOOR BEAM STA Y=1275 SHOWN STA Y=1293 SIMILAF F-F

ATTACHED ANGLE 2 (3

ETHF INSPECTION -LOOR BEAM MODIFICATIO!

STA Y=1275 SHOWN STA Y= 1293 SIMILAF F-F 2902673 FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 7 OF 10) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 41 of 62

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.

More DataQtyIdentificationNameTaskStep

(a)--Floor Beam: Around Fastener Holes Inspect1

(b)--Floor Beam: Web and Flange Surfaces Inspect2

(c)--Floor Beam: Flange Edges Inspect3 FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 8 OF 10) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 42 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

More DataQtyIdentificationNameTaskStep

(a) Do an ETHF inspection of the overwing floor beam web and the upper and lower flanges at each fastener location for any crack from STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1. Inspect the beam upper flange on both surfaces. Inspect the beam web on either face, as applicable to avoid obstructions. Inspect the beam lower flange on the upper or lower surface, as applicable to avoid obstructions.

1. Calibrate instrument on the N3 notch, in accordance with Figu re 2 of the NDTSPM procedure.

2. Utilize calibration Scan Method K, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, use Scan Method 44, in accordance with Figure 4, Sheets 1 and 2, of the NDTSPM procedure.

4. Scan around all fastener holes on the web and flange surfaces of the four floor beams, as noted above. Structure attached to the floor beams does not have to be detached from the floor beams.

– From STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 13 05.

(b) Do an ETHF inspection of the flat surfaces of the floor beam flanges and webs for any crack from STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.

1. Calibrate instrument on the N5 notch, in accordance with Figu re 2 of the NDTSPM procedure.

2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, use Scan Method 61, in accordance with Figure 6, Sheet 1 and 2, of the NDTSPM procedure.

4. Scan all web and flange surfaces of the four floor beams. Str ucture attached to the floor beams does not have to be detached from the floor beams.

– From STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 13 05.

– Scan between fastener rows, and between holes and edges. Where no fasteners exist, scan incrementally, approximately 1/4 inch apart.

– Scan angles which compose the floor beam (not repair angles).

FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 9 OF 10) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 43 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

More DataQtyIdentificationNameTaskStep

(c) Do an ETHF inspection of the floor beam flange edges for any crack from STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.

1. Calibrate instrument using the N5 notch, in accordance with i n Figure 2 of the NDTSPM procedure.

2. Utilize Scan Method J, in accordance with Figure 3, Sheet 1 o f the NDTSPM procedure to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.

3. To inspect, use Scan Method 71, in accordance with Figure 7, Sheets 1 and 2, of the NDTSPM procedure.

4. Scan along all edges of the four floor beams (and attached an gle, if present). Structure attached to the floor beams does not have to be detached from the floor beams.

– From STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 13 05.

FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAMS (SHEET 10 OF 10) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 44 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT

Page 45OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT This Figure applies only to: Group 1.

STA Y = 1305 STA Y = 1256 _ STA _ STA STA VIS Y = 1231 Y = 1256 Y = 1275 Y = 1293 Y = 1305 Y = 1321 STA 81 A 2885058 FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 1 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 Copyright © Unpublished DC10-53A184 RB Work - See page 1 for details. 45 of 62

Page 46OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT STA X = 107 X = 81.0

- B INBD 3 INCHES

TYPICAL CRACK TYPICAL CRACK

ETHF INSPECTION - B

LOOKING FORWARD

FLOOR BEAM SUPPORT Y = 1305 SHOWN Y = 1256, Y = 1275, AND Y = 1293 SIMILAR 2885092 A-A FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 2 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 46 of 62

Page 47OCROpen in PDF

REQUIREMENTS BULLETIN DC10-53A184

ALERT ALERT — FILLER 3 INCHES

- TYPICAL CRACK

TYPICAL CRACK

ETHF INSPECTION VIEW LOOKING INBOARD AT X = 81 Y = 1305 SHOWN, Y = 1256, Y = 1275 AND Y = 1293 SIMILAR B-B 2885156 FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 3 OF 6) Original Issue: February 06, 2020 Export Controlled ECCN: 9E991 DC10-53A184 RB Copyright © Unpublished Work - See page 1 for details. 47 of 62

FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING

FLOOR BEAM SUPPORTS (SHEET 4 OF 6) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.

Original Issue: February 06, 2020 DC10-53A184 RB 48 of 62 REQUIREMENTS BULLETIN DC10-53A184

ALERTALERT