duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '178e65dff145195771f9b703af7ba718451d06a32760fa40c0a5f24623b36a7d' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '178e65dff145195771f9b703af7ba718451d06a32760fa40c0a5f24623b36a7d' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
MORE DATAQTYIDENTIFICATIONNAMETASKSTEP Seal corner gaps as shown.
-BMS5-16 (BMS5-142 CLASS B or BMS5-45 CLASS B or BMS5-95 CLASS B optional) Hole Filling CompoundApply1 Fill drain path as shown. Make sure that sealed passages have no voids or disbonds that will allow fluid leakage to occur.
-BMS5-16 (BMS5-142 CLASS B or BMS5-45 CLASS B or BMS5-95 CLASS B optional) Hole Filling CompoundApply2 as shown.-BMS5-125 TYPE IIILeveling CompoundApply3 flush with structure as shown. Make sure that sealed passages have no voids or disbonds that will allow fluid leakage to occur.
-BMS5-45SealantApply4 Inject gap full of sealant using fuel injection seal.
-BMS5-45SealantInject5 Apply fillet seal as shown. Refer to SOPM 20-50-19 as an accepted procedure.
-BMS5-45SealantApply6 Apply Intermediate Seal to outboard side of the rib as shown. Refer to SOPM 20-50-19 as an accepted procedure.
-BMS5-45SealantApply7 Apply Absolute Seal to outboard side of the rib as shown.
Refer to SOPM 20- 50-19 as an accepted procedure.
-BMS5-142 (BMS5-45 optional) SealantApply8 FIGURE 12: RIGHT WING RIB SEALING AT OSS 464.475 (SHEET 5 OF 6)
BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: October 07, 2010 767-57-0121Revision 1 July 27, 2011 73 of 74 BOEING SERVICE BULLETIN 767-57-0121
MORE DATAQTYIDENTIFICATIONNAMETASKSTEP Apply parting agent on the 621EB Panel to the area shown.
Refer to SOPM 20- 50-19 as an accepted procedure.
--Parting AgentApply9 Fuel fay seal the lower exterior surface of the rib chords and splice plate as shown. Refer to SOPM 20-50- 19 as an accepted procedure.
-BMS5-45SealantApply10 Refer to 767 AMM 06-44-00 or 767-400 AMM 06-44-00 as an accepted procedure, as applicable.
It is an acceptable option to install a 654T0513-1302 skin panel in this location.
1621EBSkin PanelInstall (Kept)11 FIGURE 12: RIGHT WING RIB SEALING AT OSS 464.475 (SHEET 6 OF 6)
BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.
Original Issue: October 07, 2010 767-57-0121Revision 1 July 27, 2011 74 of 74 BOEING SERVICE BULLETIN 767-57-0121