duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'fffa315d1b86eceb4561aab2c6dd98eba9b9c01df229034dde1d71271273d6e7' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'fffa315d1b86eceb4561aab2c6dd98eba9b9c01df229034dde1d71271273d6e7' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
MODEL CL-600-2A12 & CL-600-2B16 APPENDIX 1
Basic Issue of Appendix 1: Sep 26/2013 A601-0627 Page 1 of 7 1 PRIME DESIGN ACTIVITY BOMBARDIER INC. 3AB48 2 REO NUMBER BOMBARDIER INC., MONTRÉAL 88308 LEARJET INC. 24210 BOMBARDIER INC., DOWNSVIEW 71867 SHORT BROTHERS PLC K4585 600-57-26-001 3 TITLE 4 SHEET
GENERAL REPAIR-INBOARD FLAP HINGE BOX- ATTACHMENT FWD FITTING FASTENERS 1 OF 7 5 REQUESTED BY 6 ADDITIONAL LIMITATIONS 7 MODEL 8 SERVICE EFFECTIVITY
PCR 1350
NONE CL600/CL601ALL/CL-604/CL605 1004-1085, 3001-3066, 5001-5194, 5301-5665, 5701-6999 9 DESCRIPTION / DISPOSITION DESCRIPTION:
ON A CHALLENGER CL605 ZONAL INSPECTION, ONE OF THE TWO FORWARD FASTENERS ATTACHING THE INBOARD FWD FLAP HINGE FITTINGS AT WS76.50 WAS FOUND WITH ITS HEAD MISSING.
AN INVESTIGATION DETERMINED THAT WHEN THE FWD FASTENERS WERE ORIENTED WITH THE HEAD OUTSIDE, THOSE FASTENERS WILL EXPERIENCE PREMATURE FAILURE.
ALSO FOUND HI-LITES HOLES NOT PERPENDICULAR TO SURFACE UNDER MANUFACTURED HEAD OF HI-LITES AT FLAP HINGE BOX FWD FITTING AT WS76.50 AND WS127.25 (FWD AND AFT FASTENERS LOCATION) CORRECTIVE ACTION:
PART A: GIVES INSTRUCTIONS TO INSTALL FWD FASTENERS AT INBOARD FLAP HINGE BOX FWD FITTINGS, WS 76.50 AND WS127.25 WITH FASTENER HEAD INSIDE THE WING, WITH NOMINAL, FIRST AND SECOND OVERSIZE HI-LITES(IF NEEDED)
PART B: GIVES INSTRUCTIONS TO INSTALL AFT FASTENERS AT INBOARD FLAP HINGE BOX FWD FITTINGS, WS 76.50 AND WS127.25 WITH FASTENER HEAD OUTSIDE THE WING, WITH NOMINAL, FIRST AND SECOND OVERSIZE HI-LITES(IF NEEDED)
PERFORM REPAIR ON FWD FITTINGS: 2 FWD FASTENERS FIRST (PART A) AND WHEN FINISHED PROCEED WITH THE 2 AFT FASTENERS (PART B). DO NOT REMOVE MORE THAN 2 FASTENERS FROM ONE FITTING AT THE SAME TIME.
THIS REPAIR IS TO BE CARRIED OUT TO ALL FWD FLAP HINGE FITTINGS AT WS 76.50 AND WS127.25, FWD AND AFT FASTENERS.
THIS REPAIR IS ONLY APPLICABLE FOR AIRCRAFT WITH TITANIUM FLAP FITTINGS P/N 600-10317-5/-6, 600-10317-951/-952, 600- 10320-7/-8 AND 600-10320-953/-954
NOTE: THIS REO HAS BEEN RELEASED IN ORDER TO COMPLY WITH THE REQUIREMENTS AS STATED IN SB A604-57-006, A605-57-004, A601-0627 AND A600-0763.
10 REV 11 DATE 12 PREPARED BY 13 STRESS 14 M&P 15 16 DESIGN AUTH 17 DAO AUTHORITY 18 RELEASE ORIGINAL REO REVISION A, WITH SIGNATURES, KEPT ON FILE.
19 THE TECHNICAL CONTENT OF THIS DOCUMENT IS APPROVED
UNDER THE AUTHORITY OF TRANSPORT CANADA DESIGN APPROVAL ORGANIZATION, DAO NO. 93-Q-02
BA ENGINEERING DISPOSITION FOR APPROVAL BY OPERATOR’S LOCAL AIRWORTHINESS AUTHORITY LA PRÉSENTE INSTRUCTION TECHNIQUE DE RÉPA RATION A ÉTÉ ÉTABLIE D'APRÈS LES DONNÉES FOURNIES À BOMBARDIER INC. PAR L'EXPLOITANT OU PAR SON REPRÉSENTANT. LA RESPONSABILITÉ INCOMBE À L'EXPLOITANT OU À SON REPRÉSENTANT DE S'ASSURER QUE TOUTES LES DONNÉES FOURNIES SONT COMPLÈTES ET EXACTES. BOMBARDIER INC. DÉCLINE TOUTE RESPONSABILITÉ QUANT AUX CONSÉQUENCES RÉSULTANT D'UN RAPPORT DE DOMMAGE OU D'ANOMALIE INCOMPLET OU INEXACT.
LES RENSEIGNEMENTS, LES DONNÉES ET DESSIN S TECHNIQUES DIVULGUÉS DANS LES PRÉSENTES SONT LA PROPRIÉTÉ EXCLUSIVE DE BOMBARDIER INC. OU COMPORTENT DES DROITS DE PROPRIÉTÉ APPARTENANT À AUTRUI ET NE PEUVENT ÊTRE DIVU LGUÉS À QUICONQUE NI UTILISÉS PAR QUI QUE CE SOIT SANS LE CONSENTEMENT ÉCRIT DE BOMBARDIER INC. LE DÉTENTEUR DES PRÉSENTES S'ENGAGE, DANS TOUTES CIRCONSTANCES, À GARDER CONFID ENTIELS LES DONNÉES ET DESSINS TECHNIQUES QU'ELLES CONTIENNENT. CE QUI PRÉCÈDE NE S'APPLIQUE PAS AUX PERSONNES QUI ONT DES DROITS DE PROPRIÉTÉ SUR CES RENSEIGNEMENTS, DONNÉES TECHNIQUES ET DESSINS DANS LA MESURE OÙ CES DROITS EXISTENT.
THIS REPAIR ENGINEERING ORDER HAS BEEN PREPARED ON THE BASIS OF INFORMATION SUPPLIED TO BOMBARDIER INC. BY THE OPERATOR OR HIS AGENT. IT IS THE RESPONSIBILITY OF THE OPERATOR OR HIS AGENT TO VERIFY THAT THE INFORMATION SUPPLIED IS COMPLETE AND ACCURATE. BOMBARDIER INC. DOES NOT ACCEPT RESPONSIBILITY FOR ANY CONSEQUENCE RESULTING FROM INCOMPLETE OR INACCURATE REPORTING OF THE DAMAGE / DISCREPANCY.
THE INFORMATION, TECHNICAL DATA AND DESIGNS DI SCLOSED HEREIN ARE THE EXCLUSIVE PROPERTY OF BOMBARDIER INC. OR CONTAIN PROPRIETARY RIGHTS OF OTHERS AND ARE NOT TO BE USED OR DISCLOSED TO OTHERS WITHOUT THE WRITTEN CONSEN T OF BOMBARDIER INC. THE RECIPIENT OF THIS
DOCUMENT, BY ITS RETENTION AND USE AGREES TO HOLD IN CONFIDENCE THE TECHNICAL DATA AND DESIGNS CONTAINED HEREIN. THE FOREGOING SHALL NOT APPLY TO PERSONS HAVING PROPRIETARY
RIGHTS TO SUCH INFORMATION, TECHNICAL DATA OR SUCH DESIGNS TO THE EXTENT THAT SUCH RIGHTS EXIST. D.3363 -27 REV 1999-07
X
MODEL CL-600-2A12 & CL-600-2B16 APPENDIX 1 10 REV - - -A 2 REO NUMBER 4 SHEET 600-57-26-001 2
Basic Issue of Appendix 1: Sep 26/2013 A601-0627 Page 2 of 7
GENERAL NOTES:
1. FINISH CODES PER SRM PSP607 CH.51-58-138/42 (CL600/CL601) OR SRM CL604/CL605 CH.51-01-04 OR BAERD GEN004
2. INSTALL HI-LITES INTERFERENCE FIT, (EXCEPT HOLES IN TITANIUM FITTINGS) AS PER SRM PSP607 CH.51-43-01 / SRM CL604- CL605 CH.51-42-36 OR BAPS151-029.
WARNING
WHEN INSTALLING HI-LITES ENSURE A FULL CONTACT BETWEEN HEAD AND ADJACENT UNDER SURFACE. DO NOT FORCE CONTACT BY HITTING THE HEAD OF HI- LITE WITH A HAMMER OR OTHER TOOL. THIS REO PROVIDE INSTRUCTIONS TO REPAIR INSTALLATION IN ORDER TO HAVE A FULL CONTACT.
CAUTION
DO NOT DRILL OFF HEADS OF HI-LOKS / HI-LITES AND DRIVE SHANK INTO WING BOX AS THIS COULD CAUSE SEVERE SCORING OF THE HOLES. REMOVE COLLAR AND DRIVE HI-LOK / HI-LITES FROM THREADED END.
3. WET INSTALL HI-LITES PER SRM PSP607 CH.51-57-00 / SRM CL604-CL605 CH.51-23-04 / SPM 51-23-00
4. IT IS PERMISSIBLE TO INSTALL FIRST OVERSIZE HI-LITE HST154AG8-( ) IN LIEU OF NOMINAL HI-LITE HST54AG8-( )
5. IT IS PERMISSIBLE TO INSTALL SECOND OVERSIZE HI-LITE HST 254AG8-( ) IN LIEU OF FIRST OVERSIZE HI-LITE HST154AG8-( )
6. INTERMIXING NOMINAL, FIRST AND SEC OND OVERSIZE HI-LITES IS ACCEPTABLE.
7. IT IS PERMISSIBLE TO USE HI-LITE HST54AC8-( ) OR HST54AP8-( ) OR HST54AZ8-( ) IN LIEU OF HST54AG8-( )
8. IT IS PERMISSIBLE TO USE HI-LITE HST154AC8-( ) OR HST154AP8-( ) OR HST154AZ8-( ) IN LIEU OF HST154AG8-( ).
9. IT IS PERMISSIBLE TO USE HI-LITE HST254AC8-( ) OR HST254AP8-( ) OR HST254AZ8-( ) IN LIEU OF HST254AG8-( ).
10. BRUSH COAT FASTENERS HEADS INSIDE FUEL TANK (WS1 27.25) AND FILL ALL THE GAPS AS PER SRM PSP607 CH.51-57-00 / SRM CL604-CL605 CH.51-23-04 / SPM 51-23-00
Changes from Rev NC:
Sh.1:
-Text in “Corrective Action” different to be clearer. Allow to perform repair 2 fasteners same time per fitting in lieu of 1 per fitting
Sh.2:
-Added note 3, 7 and 10. Note 6 Changed. Note numbering changed to accommodate new notes.
Sh.3 -In Fig.1 length of Hi-Lites indicated to avoid confusion. Added note that Hi-Lite length should be adjusted on instl.
Sh.4-5-6: (previous 4-5) -Added Note: For FWD fasteners rework it is not necessary to disconnect flap hinge box.
-Text was reorder to be clearer -Shim PN changed, added shims dimensions in sh.5 -Spotfacing dia allow being smaller to avoid interference -Removed option for tapered shim -Added NOTE: Length of Hi-Lites is suggested. User proper length to suit instl.
Sh.7 (previous Sh.6) -Reorder to be clearer -Added note for Hi-Lite removal
CHÄLLENGER 601 MODEL CL-600-2A12 & CL-600-2B16 APPENDIX 1 10 REV - - -A 2 REO NUMBER 4 SHEET 600-57-26-001 3 600-10208 REF S-5178-1- SHIM (REF) (SHIM USED @ HINGE FITTING) HI-LITE HST54AG8-12 INSTALLED WITH THE HEAD INSIDE WING BOX (2 FWD LOCATIONS) HI-LITES HST54AG8-12 WITH THE HEAD INSTALLED OVER FITTING 500-10317 (2 AFT LOCATIONS) 600-10317 FITTING (REF) SELF-ALIGNING NUT B0203015-4 FLAP FITTING AT WS76.50 (KFN674-4) 600-10017 REF HI-LITE HST54AG8-11 INSTALLED WITH THE HEAD INSIDE VING BOX (2 FWD LOCATIONS) 5-5178-2 SHIM (REF) (SHIM USED • HINGE FITTING STR 6_ HI-LITES HST54AGB-12 WITH THE HEAD INSTALLET
- STR 5 OVER FITTING 600-10320 (2 AFT LOCATIONS) 600-10320 FLAP FITTING (REF) SELF-ALIGNING NUT B0203015-4 (KFN674-4) FLAP FITTING AT WS127.25 FWD FIGURE 1
LENGHT OF HI-LITES SHOULD BE ADJUSTED ON INSTALLATION | Basic Issue of Appendix 1: Sep 26/2013 A601-0627 Page 3 of 7
MODEL CL-600-2A12 & CL-600-2B16 APPENDIX 1 10 REV - - -A 2 REO NUMBER 4 SHEET 600-57-26-001 4
Basic Issue of Appendix 1: Sep 26/2013 A601-0627 Page 4 of 7 PART A: THIS REPAIR IS APPLICABLE ONLY TO FWD FASTENERS AT WS76.50 AND WS127.25 (SEE FIGURE 1)
NOTE: FOR FWD FASTENER REWORK IT IS NOT NECESSARY TO DICONNECT FLAP HINGE BOX.
1. REMOVE EXISTING FASTENER.
CAUTION
DO NOT DRILL OFF HEADS OF HI-LOKS/HI-LITES AND DRIVE SHANK INTO WING-BOX AS THIS COULD CAUSE SEVERE SCORING OF THE HOLES.
REMOVE COLLAR AND DRIVE HI-LOK/HI-LITE FROM THREADED END.
2. INSPECT AROUND THE HOLE FOR MARKS, GOUGES ETC. OVER FITT ING P/N 600-10317-5/-6 (WS76.50) / 600-10320-7/-8 (WS127.25).
3. IF DAMAGE IS FOUND PERFORM SPOT FACING 0.625 DIA X 0.062R IN LINE WITH EXISTING HOLE OVER FITTING 600-10317 / 600- 10320. SPOT FACING DEPTH SHOULD BE THE MINIMUM TO REMOVE DAMAGE AND ENSURE A FULL CONTACT SURFACE FOR NUT KFN674-4. MAX DEPTH 0.007” AND MIN. REMAINING FITTING THICKNESS SHOULD BE 0.243”. FLUORESCENT PENETRANT INSPECTION PER SRM PSP607 CH.51-18-00 / NDTM, PART 8, SECTION 1 TO ENSURE REWORKED AREA IS CRACK FREE. RESTORE FINISH T022, COLOR GREY #16473 PER FED.STD.595
WARNING IF PREVIOUS SPOT FACING EXIST, THE MAX TOTAL DEPTH IS 0.007” (PREVIOUS SPOT FACING + NEW SPOT FACING) AND MIN. REMAINING FITTING THICKNESS SHOULD BE 0.243”
4. TO ENSURE NO GAP UNDER THE HEAD AND A PERPENDICU LAR SURFACE PROCEED AS FOLLOWS (SEE FIGURE 2 AND 3)
A. MANUFACTURE SHIM P/N 600-57-26-001-001/-002/-003/-004/-005 /-006/-007/-008 AS PER FIGURE 3: MATERIAL AL.AL.7075-T6, PER SAE AMS-QQ-A-250/12 OR AL.AL 2024-T3 OR T4 PER SAE AMS-QQ-A-250/4, THICKNESS: 0.063”. IT IS PERMISSIBLE TO TRIM TO SUIT RADIUS AND SHAPE OF MACHINED PARTS AROUND. FINISH A022.
B. BOND SHIMS TO STRUCTURE OVER TH E HOLE (SEE FIGURE 3) AS PER SRM PSP607 CH.51-55-11 (CL600-CL601) OR SPM CH.51-24-05 (CL604-CL605) OR BAPS155-079. ENSURE ADHESIVE IS COMPLETELY CURED BEFORE CONTINUING. IT IS
PERMISSIBLE TO OPEN A SMALL HOLE IN SHIMS TO CLAMP SHIM USING A TEMPORARY FASTENER OR BOLT-WASHER-NUT WHILE ADHESIVE IS CURING.
C. OPEN HOLE IN SHIM CONCENTRIC FROM EXISTING HOLE IN STRUCTURE (SAME DIA AS EXISTING HOLE IN STRUCTURE) D. BACK SPOT FACING 0.625 DIA SHIM P/N 600-57-26-001-00X IN ORDER TO GET A FULL CONTACT SURFACE FOR HI-LITE HEAD.
PERFORM THE SPOT-FACING CAREFULLY, IN SEVERAL STEPS, IN ORDER TO AVOID MACHINE THRU SHIM AND DAMAGE EXISTING INNER FITTING. RESTORE FINISH A022.
NOTE
IF CUTTER INTERFERES WITH ADJACENT STRUCTURE, IT IS PERMISSIBLE TO
USE SMALLER SPOTFACING DIA ENSURING THAT FLAT SURFACE IS BIGGER THAN HI-LITE HEAD DIA.
CHÄLLENGER 601 DIE MODEL CL-600-2A12 & CL-600-2B16 APPENDIX 1 10 REV - - -A 2 REO NUMBER 4 SHEET 600-57-26-001 5 SHIM 600-57-26-001-004 SHN 600-10208 REF - INBD FWD 600-10209 REF - 00-0-00-0280 LHS, VIEW LOOKING DOWN AT WS76.50 SHIM 0-57-26-001-001 2 0-57-26-001-0 500 REF 500 REF . 400 REF 600-57-28-01-006 SAN 600-10091 REF (REF) INBD FWD LHS. VIEW LOOKING DOWN AT WS127.25 R .31 R. 12 -R. 16 R. 25 R .20 4 PLCS. R. 12 3 PLCS.
. 75 - SHIM 00-57-25-001-0035 00-57-26-001-00 SHIM 600-57-26-001-007 SHN 600-57-26-001-008 OF R . 12 - —R. 16 R .20 4 PLCS. •R .25 R. 12 3 PLCS SHIM 00-57-26-001-0015 SHIM 00-57-26-00 600-57-26-001-005 SEN FIGURE 3: SHIMMING | Basic Issue of Appendix 1: Sep 26/2013 A601-0627 Page 5 of 7
CHÄLLENGER 601 MODEL CL-600-2A12 & CL-600-2B16 APPENDIX 1 10 REV - - -A 2 REO NUMBER 4 SHEET 600-57-26-001
5. INSPECT INSIDE FASTENER HOLES FOR DAMAGE, GAUGES, MARKS, CORROSION, ETC. VERIFY DIAMETER.
6. IF HOLE IS DAMAGED OR ENLARGED PROCEED AS FOLLOWS:
A. OPEN HOLE TO DIA .2606-.2636 FOR FIRST OVERSIZE (DIA .2762-.2792 FOR SECOND OVERSIZE) (SEE FIGURE 4) B. OPEN HOLE IN FITTING P/N 600-10317/600-10320 TO DIA .2766-.2792 FOR FIRST OVERSIZE (DIA .2918-.2948 FOR SECOND OVERSIZE). USE A CONTROLLED COUNTERBORE TO ENSURE PASS THRU THE FITTING 600-10317/600-10320 BUT DO NOT TOUCH THE WINGPLANK. IT IS ACCEPTABLE TO TOUCH THE SHIM S-5178. (SEE FIGURE 4) ฿ . 2450-.2480 (NOMINAL) . 2606-.2636 (FIRST OVS) SHIM S5178 IS ADJUSTED ON INSTALLATION . 2762-.2792 (SECOND OVS) AND THICKNESS COULD BE AS LOW AS 0.040" INNER FITTING 600-10208/600-10209/600-10091 (REF) ,070 REF. WINGPLANK (REF) SHIM S-5178-1/-2 (REF) .250 REF. FITTING 600-10317 / 600-10320 (REF)
• .2606-.2636 (NOMINAL)
THIS SURFACE COULD HAVE A SPOT FACING WHEN OPENING THE HOLE IN FITTING 600-10317/600-10320 . 2766-.2792 (FIRST OVS) ENSURE TO MEASURE THE THICKNESS LOCALLY THRU THE HOLE . 2918-.2948 (SECOND OVS) AND ADD 0.005" TO GET THE DEPTH OF MACHINING TO ENSURE
PASS THRU FITTING BUT DO NOT TOUCH THE WINGPLANK FIGURE 4
7. MAKE A CHAMFER RELIEF ON REO SHIM 600-57-26-001-00X AS PER SRM PSP607 CH.51-40-21 (CL600-CL601), SRM CL604/CL605 CH.51-40-08 OR BAPS151-029 FINISH ALL BARE METAL SURFACES CODE A022 (DO NOT PAINT INSIDE HOLE AND CHAMFER RELIEF)
9. INSTALL HI-LITE HST54AG8-12 (OR HST154AG8-12 FOR FIRST OVS OR HST254AG8-12 FOR SECOND OVERSIZE) PIN AND KFN674-4 NUT FOR THE FITTING 600-10317 (WS 76.50) AND HI-LITE HST54AG8-11 PIN (OR HST154AG8-11 FOR FIRST OVS OR HST254AG8-11 FOR SECOND OVERSIZE) AND KFN674-4 NUT FOR THE FITTING 600-10320 (WS127.25) WITH THE HEAD INSIDE OF WING BOX AS SHOWN IN FIGURE 1.
WARNING
WHEN INSTALLING HI-LITES ENSURE A FULL CONTACT BETWEEN HEAD AND ADJACENT UNDER SURFACE. DO NOT FORCE CONTACT BY HITTING THE HEAD OF HI- LITE WITH A HAMMER OR OTHER TOOL.
NOTE LENGHT OF HI-LITES IS SUGGESTED. USE PROPER LENGHT TO SUIT INSTALLATION.
| Basic Issue of Appendix 1: Sep 26/2013 A601-0627 Page 6 of 7
MODEL CL-600-2A12 & CL-600-2B16 APPENDIX 1 10 REV - - -A 2 REO NUMBER 4 SHEET 600-57-26-001 7
Basic Issue of Appendix 1: Sep 26/2013 A601-0627 Page 7 of 7 PART B: THIS REPAIR IS APPLICABLE ONLY TO AFT FASTENERS (SEE FIGURE 1) NOTE: FOR AFT FASTENER REWORK IT IS NECESSARY TO DICONNECT FLAP HINGE BOX.
1. REMOVE EXISTING FASTENER.
CAUTION
DO NOT DRILL OFF HEADS OF HI-LOKS/HI-LITES AND DRIVE SHANK INTO WING-BOX AS THIS COULD CAUSE SEVERE SCORING OF THE HOLES.
REMOVE COLLAR AND DRIVE HI-LOK/HI-LITE FROM THREADED END.
2. INSPECT AROUND THE HOLE FOR MARKS, GOUGES ETC. OVER FI TTING P/N 600-10317-5/-6 (WS76.50) / 600-10320-7/-8 (WS127.25).
INSPECT ALSO FOR GAPS UNDER HEAD AND PERPENDICULARITY BETWEEN SURFACE AND FASTENER HOLE TO ENSURE A FULL CONTACT BETWEEN HI-LITE HEAD AND SURFACE.
3. IF DAMAGE IS FOUND AND/OR A GAP OR NOT PERPENDICULARITY IS FOUND PERFORM SPOT FACING 0.625 DIA X 0.062R IN LINE WITH EXISTING HOLE (SEE FIGURE 5). SPOT FACING DEPTH SHOULD BE THE MINIMUM TO REMOVE DAMAGE AND ENSURE A FULL CONTACT SURFACE FOR HI-LITE HEAD. MAX DEPTH 0.010” AND MIN. REMAINING FITTING THICKNESS SHOULD BE 0.240”.
FLUORESCENT PENETRANT INSPECTION PER SRM PSP607 CH.51-18-00 / NDTM, PART 8, SECTION 1 TO ENSURE REWORKED AREA IS CRACK FREE.
WARNING IF PREVIOUS SPOT FACING EXIST, THE MAX TOTAL DEPTH IS 0.010” (PREVIOUS SPOT FACING + NEW SPOT FACING) AND MIN. REMAINING FITTING THICKNESS SHOULD BE 0.240”
4. INSPECT INSIDE FASTENER HOLES FOR DA MAGE, GAUGES, MARKS, CORROSION, ETC. VERIFY DIAMETER IF HOLE IS DAMAGED OR ENLARGED PROCEED AS FOLLOWS:
A. OPEN HOLE TO DIA .2606-.2636 FOR FIRST OVERSIZE (DIA .2762-.2792 FOR SECOND OVERSIZE) (SEE FIGURE 4) B. OPEN HOLE IN FITTING P/N 600-10317/600-10320 TO DI A .2766-.2792 FOR FIRST OVERSIZE (DIA .2918-.2948 FOR SECOND OVERSIZE). USE A CONTROLLED COUNTERBORE TO ENSURE PASS THRU THE FITTING 600-10317/600-10320 BUT DO NOT TOUCH THE WINGPLANK. IT IS ACCEPTABLE TO TOUCH THE SHIM S-5178. (SEE FIGURE 4)
5. MAKE A CHAMFER RELIEF AS PER SRM PSP607 CH.51-40-21 (CL600-CL601), SRM CL604/CL605 CH.51-40-08 OR BAPS151-029.
6. RESTORE FINISH T022, COLOR GREY #16473 PER FED.STD.595 (DO NOT PAINT INSIDE HOLE AND CHAMFER RELIEF)
7. INSTALL HI-LITE HST54AG8-12 PIN (OR HST154AG8-12 FOR FIRST OVS OR HST254AG8-12 FOR SECOND OVS) AND KFN674-4 NUT WITH THE HEAD OF HI-LITE OVER FITTING 600-10317 (WS 76.50) / 600-10320 (WS127.25) AS SHOWN IN FIGURE 1.
WARNING
WHEN INSTALLING HI-LITES ENSURE A FULL CONTACT BETWEEN HEAD AND ADJACENT UNDER SURFACE. DO NOT FORCE CONTACT BY HITTING THE HEAD OF HI- LITE WITH A HAMMER OR OTHER TOOL.