Service bulletin · Bombardier

No revision namedCH601A-TLMC-TR-5-281 · 1 page · 92 KB

© Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2021-0784, the docket of AD 2021-25-13. Not covered by OpenAirDocs’ CC0 dedication.

Docket FAA-2021-0784 (document 0004) · AD 2021-25-13

Manufacturer
Bombardier
Type
Service Bulletin
Number
CH601A-TLMC-TR-5-281

A newer revision may exist than any OpenAirDocs knows of: check with the manufacturer.

On this page

Text · 1

From the PDF’s text layer: layout, tables and figures are lost. The PDF is the document. © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2021-0784, the docket of AD 2021-25-13. Not covered by OpenAirDocs’ CC0 dedication.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '6f97fdc01aa13b6452685925ab9eb833dc1e2d6f0c3a26dde0d1d5f8f880ee95'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

REASON FOR ISSUE: To introduce a task for the Skin Circumferential Splice at FS559.00, between STR10L and STR10R.

ACTION: Add the task that follows to the list of Chapter 53 Checks:

MAINTENANCE CHAPTER 53 CHECKS CHECK ZONE ACCESS MANUAL − CH. 5 DESCRIPTION INTERVAL

REFERENCE 53−30−00−191 * Skin Circumferential Splice at FS559.00, between STR10L and STR10R

• NDT Check (Ref. PSP 612, Part 6, ET−53−30−32) PHASE−IN: For aircraft with less than 11500 Hours, this check must be accomplished before 15000 Hours. For aircraft with 11500 Hours or more but less than 15000 Hours, this check must be accomplished within 3500 Hours but before 17500 Hours. For aircraft with 15000 Hours or more but less than 17500 Hours, this check must be accomplished within 2500 Hours but before 19000 Hours. For aircraft with 17500 Hours or more, this check must be accomplished within 1500 Hours.

T 15000 H R 15000 H 241 242

TIME LIMITS/MAINTENANCE CHECKS PSP 601A−5 TEMPORARY REVISION NO. TR 5−281 INSERT IN SECTION 5−10−30 FACING PAGE 31 EFFECTIVITY: ALL TR 5−281 5−10−30 Page 1 of 1Apr 30/2020 NOTE: Record the incorporation of this Temporary Revision on the yellow RECORD OF TEMPORARY REVISIONS and the LIST OF EFFECTIVE TEMPORARY REVISIONS sheets at the front of this publication.