Copy · TR53-128 · 19 pages

© Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2024-2012, the docket of AD 2025-02-03. Not covered by OpenAirDocs’ CC0 dedication.

Text

From the PDF’s text layer: layout, tables and figures are lost. The PDF is the document.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '479c618c2c5f47e0929e97cac60d07f3a232659229be7c32456f1b7acfb4d4fc'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

/C0078/C0079/C0078/C0068/C0069/C0083/C0084/C0082/C0085/C0067/C0084/C0073/C0086/C0069/C0032/C0084/C0069/C0083/C0084/C0073/C0078/C0071/C0032/C0077/C0065/C0078/C0085 /C0065/C0076 /C0080/C0097/C0114/C0116 /C0052 /C0045 /C0085/C0108/C0116/C0114/C0097/C0115/C0111/C0110/C0105/C0099 /C0080/C0097/C0114/C0116 /C0052 /C0080/C0097/C0103/C0101/C0032/C0049

/C0069/C0070/C0070/C0069/C0067/C0084/C0073/C0086/C0073/C0084/C0089/C0058 /C0083/C0069/C0069 /C0080/C0065/C0082/C0065/C0071/C0082/C0065/C0080/C0072 /C0050 /C0084/C0082/C0032/C0053/C0051/C0045/C0049/C00508 /C0084/C0069/C0077/C0080/C0079/C0082/C0065/C0082/C0089 /C0082/C0069/C0086/C0073/C0083/C0073/C0079/C0078 /C0053/C0051/C0045/C0049/C00508

/C0070/C0073/C0076/C0073/C0078/C0071 /C0073/C0078/C0083/C0084/C0082/C0085/C0067/C0084/C0073/C0079/C0078/C0083/C0058 /C0073/C0110/C0115/C0101/C0114/C0116 /C0116/C0104/C0105/C0115 /C0084 /C0101/C0109/C0112/C0111/C0114/C0097/C0114/C0121 /C0082/C0101/C0118/C0105/C0115/C0105/C0111/C0110 /C0102/C0097/C0099/C0105/C0110/C0103 /C0084/C0065/C0083/C0075 /C0080/C0097/C0114/C0116 /C0052/C0044 /C0053/C0051/C0045/C0052/C0049/C0045/C0049/C00562/C0046 /C0082/C0101/C0099/C0111/C0114/C0100 /C0116/C0104/C0101 /C0105/C0110/C0099/C0111/C0114/C0112/C0111/C0114/C0097/C0116/C0105/C0111/C0110 /C0111/C0102 /C0116/C0104/C0105/C0115 /C0084 /C0101/C0109/C0112/C0111/C0114/C0097/C0114/C0121/C0082/C0101/C0118/C0105/C0115/C0105/C0111/C0110 /C0111/C0110 /C0116/C0104/C0101 /C0121/C0101/C0108/C0108/C0111/C0119 /C0082/C0069/C0067/C0079/C0082/C0068 /C0079/C0070 /C0084/C0069/C0077/C0080/C0079/C0082/C0065/C0082/C0089 /C0082/C0069/C0086/C0073/C0083/C0073/C0079/C0078/C0083 /C0115/C0104/C0101/C0101/C0116 /C0097/C0116 /C0116/C0104/C0101 /C0102/C0114/C0111/C0110/C0116 /C0111/C0102 /C0116/C0104/C0105/C0115 /C0118/C0111/C0108/C0117/C0109/C0101/C0046 /C0075/C0101/C0101/C0112 /C0116/C0104/C0105/C0115 /C0084/C0101/C0109/C0112/C0111/C0114/C0097/C0114/C0121 /C0082/C0101/C0118/C0105/C0115/C0105/C0111/C0110 /C0117/C0110/C0116/C0105/C0108 /C0082/C0101/C0118/C0105/C0115/C0105/C0111/C0110 /C00525 /C0105/C0110/C0099/C0111/C0114/C0112/C0111/C0114/C0097/C0116/C0101/C0115 /C0116/C0104/C0105 /C0115 /C0105/C0110/C0102/C0111/C0114/C0109/C0097/C0116/C0105/C0111/C0110 /C0105/C0110/C0116/C0111 /C0116/C0104/C0101 /C0078/C0111/C0110/C0100/C0101/C0115/C0116/C0114/C0117/C0099/C0116/C0105/C0118/C0101 /C0084 /C0101/C0115/C0116/C0105/C0110/C0103 /C0077/C0097/C0110/C0117/C0097/C0108/C0046 /C0068/C0069/C0083/C0067/C0082/C0073/C0080/C0084/C0073/C0079/C0078/C0058 53-41-182 This Temporary Revision revises TASK Part 4, 53- 41- 182 Inspection of the LATERAL BEAM WEB and LOWER CAP FLANGES AT FS513.00 to introduce a new calibration reference standard (CRS) and make other miscellaneous changes.

of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2 INSPECTION OF THE LATERAL BEAM WEB AND LOWER CAP FLANGES AT FS513.00

1. General A. Function

(1) This inspection is used to examine for subsurface cracks in the lateral beam (frame sector) web and the lower cap flanges at FS513.00, between LBL3.10 and RBL3.10.

NOTE: The inspection is to be done at the same time as Part 6, 53−41−182.

B. Reference Information

(1) For added data that is necessary to do this inspection, refer to the sections of the manuals that follow:

− Nondestructive Test Manual (NDTM) Part 1, General − Structure Repair Manual (SRM) − Aircraft Maintenance Manual (AMM).

(2) individual certified to an NDT Standard approved by the National Airworthiness Authority.

C. Location

(1) The lateral beam web and the lower cap flanges are found in Zone 160 (Refer to NDTM Part 1, General 51−01−03).

D. Access

(1) The access to the inspection area is from the main−landing−gear (MLG) wheel bins.

E. Parts Examined in This Procedure Refer to Table 1.

Table 1 − Part Identification Data ITEM NO. [1] DESCRIPTION DRAWING OR PARTNUMBER [2] MATERIAL SPECIFICATION −− Frame sector 601R32028 7050−T7452 Alalloy forging CMS 514−04 NOTE [1]: Parts that do not include an item number are not identified in Figure 2 or Figure 5.

NOTE [2]: Numbers that do not include a dashed suffix are drawing numbers.

2. Effectivity A. All aircraft with Post SB 601R−29−020, or with Modsums TC601R14198 (addition of reinforcing strap at FS513.00) and TC601R14160 (cutout in the hydraulic support beam) incorporated.

NOTE: NDTM Part 6, 53−41−182 must be accomplished in order to complete the full inspection.

TR 53-128

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic

AWL 53-41-182 This inspection must be done by a level II or Level III ultrasonic quali-fied Page 2of 19 Sep 15/23

Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2

3. Tools and Equipment A. Use the items identified as follows, or their equivalent (Refer to NDTM Part 1, 51−20−04):

NOTE: The calibration data given in this procedure is for the specified ultrasonic equipment. It is possible that other equivalent equipment will use different values.

Ensure that the performance characteristics of the test instrument and transducer is established in accordance with the procedures outlined in the Recommended Practice ASTM E317.

Equivalent ultrasonic equipment may be used provided that it satisfies the requirement of this procedure and is capable of resolving the reference notches in the calibration standard at the requirement level of resolution.

− Sonatest Model: UFDS, Ultrasonic Flaw detector − Angle beam type transducer, 5.0 MHz frequency, 45 degrees refractive angle in aluminum, contact surface 0.30 in. by 0.70 in. (7.62 mm by 17.78 mm), Harisonic Model: PAB−0504 − Angle beam miniature transducer, 5.0 MHz frequency, 45 degrees refractive angle in aluminum, contact surface 0.19 in. by 0.35 in. (4.83 mm by 8.90 mm) VM Products Model: VM 7−121−TC−A − Ultrasonic Couplant Gel Inspectech LTD: Gorptech Industrial − MHI RJ Aviation calibration reference standard EXCM601R30014, similar in material and cross section as the inspection area and containing subsurface electrical discharge machined (EDM) notches − MHI RJ Aviation calibration reference standard E XCM601R30038, similar in material and cross section as the inspection area and containing subsurface electrical discharge machined (EDM) notches − Coaxial cable.

4. Preparation and Cleaning A. Prepare the inspection area as follows:

(1) Remove all of the fasteners collars adjacent to the scanning surface if they interfere with the transducer.

WARNING: DO NOT REMOVE ANY OF THE FASTENERS HEADS AFTER YOU REMOVE THE FASTENERS COLLARS. REMOVAL OF THE FASTENERS HEADS CAN CAUSE INJURIES TO PERSONS AND /OR DAMAGE TO EQUIPMENT .

(2) Identify the location to be inspected.

(3) Remove the MLG wheel bins to get access to the external structure of the lateral beam and lower cap flanges at FS513.00 (Refer to AMM Task 53−83−01−000−801).

WARNING: MAKE SURE THAT THERE IS A GOOD FLOW OF CLEAN AIR AND SUFFICIENT FIRE PROTECTION. USE APPROVED BODY PROTECTION WHEN YOU USE SOLVENTS. ALL SOLVENTS ARE POISONOUS AND SOME ARE FLAMMABLE.

(4) Clean the following surfaces where the transducer will be placed for inspection (Refer to the SRM, Chapter 51−26−00):

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic

TR 53-128 Page 3of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2 − The aft surface on the web of the lateral beam − The forward and aft surface of the lateral beam lower−cap−flanges.

NOTE: It is not necessary to remove the finish from the parts unless it shows deterioration or local damage.

(5) If the finish in the area to be inspected is damaged or deteriorated, remove the finish (Refer to the SRM, chapter 51).

5. Inspection for Subsurface Cracks in the Lateral Beam (Frame Sector) Web at FS513.00 Between LBL3.10 and RBL3.10 A. Equipment Calibration Refer to Figure 1.

(1) Connect the transducer PAB−0504 with the coaxial cable to the ultrasonic instrument.

(2) Turn the power ON and set the instrument to pulse−echo test mode and 5 MHz test frequency.

(3) Use a removable trace marker to draw two vertical reference lines on the surface of the −3 and −4 frame sectors web on the calibration reference standard EXCM601R30014, from the most outboard edge of the −1 center joint fitting extending up to the −3 and −4 frame−sectors upper flanges.

NOTE: The two reference lines are used to limit the extend of the initial scan.

(4) Apply a thin even layer of couplant gel on the web aft surfaces of −3 and −4 frame sectors, between the reference lines and outboard edges.

(5) Do the distance calibration on the calibration reference standard E XCM601R30014, as follows:

(a) Align the front of the transducer with the vertical reference line such that the soundbeam is directed towards the inboard edge of the −4 frame sector at BL0.00, as shown in Transducer Placement 1 (Refer to Figure 1, Sheet 1).

(b) Manipulate the transducer and adjust the GAIN (sensitivity) control as necessary to obtain a maximized 40% full screen height (FSH) edge reflection signal from the −4 frame sector, as shown in CRT display, Transducer Placement 1 (Refer to Figure 1, Sheet 2).

(c) Use the DELAY and RANGE controls to set the leading edge of the first reflection signal from the −4 frame sector edge at 100% of the horizontal limit on the horizontal baseline, as shown in CRT display, Transducer Placement 1 (Refer to Figure 1, Sheet 2).

(6) Do the sensitivity calibration on the calibration reference standard as follows:

(a) Couple the transducer to the −3 frame sector web, align the front of the transducer with the vertical reference line such that the soundbeam is directed towards NOTCH E, as shown in Transducer Placement 6 (Refer to Figure 1, Sheet 1).

(b) Manipulate the transducer to obtain a maximized amplitude signal from NOTCH E and adjust the GAIN control to obtain a 50% FSH signal response for NOTCH E, as shown in Transducer Placements 2, 4 and 6 (Refer to Figure 1, Sheet 2).

This is the initial scan sensitivity.

TR 53-128 Page 4of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2 rnd5341182_003.dg, kms/rm, 18/04/00 BL 0.00

AFT UPPER JOINT−ANGLE (REF) −1 CENTER JOINT

FITTING

VERTICAL

REFERENCE LINE

TRANSDUCER PLACEMENT 1

TRANSDUCER PLACEMENT 2

OUTBOARD EDGE

LOWER FLANGE (TWO PLACES)

UPPER FLANGE (TWO PLACES) −3 FRAME SECTOR−4 FRAME SECTOR (BOTH SIDES) EOP−4 EOP−3 (REF)

TRANSDUCER PLACEMENT 3

TRANSDUCER PLACEMENT 4

TRANSDUCER PLACEMENT 5

TRANSDUCER PLACEMENT 6

OUTBOARD EDGE A B C D E

1. Letters A through E are EDM notches in −3 frame sector.

2. All EDM notches are 0.005 inch (0.127 mm) wide by 0.25 inch (6.35 mm) long.

NOTESR EFERENCE STANDARD EXCM601R 30014 AND TRANSDUCER

PLACEMENTS (VIEW LOOKING FWD)

3. EOP: Edge of part.

REINFORCING STRAP Transducer Placements and CRT Display − Distance and Sensitivity Calibration Figure 1 (Sheet 1)

TR 53-128 Page 5of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2 TRANSDUCER PLACEMENTS 2, 4 AND 6 50 1000 50 100 IP NEA WE DEFECT WINDOW 50 1000 50 100 IP WE 50 1000 50 100 IP NED WE NEB

CRT DISPLAY 50 100 0 50 100 IP WE EOP−4 ECHO NEE, NEC EOP−3, −4 ECHO TRANSDUCER PLACEMENT 1 TRANSDUCER PLACEMENTS 3 AND 5 TYPICAL NOTCH−FREE DISPLAY IP − WE − NEA − NEB − NEC − NED − NEE − NOTES Initial pulse.

Wedge echo (non−relevant indication).

Echo from notch A.

Echo from notch B.

Echo from notch C.

Echo from notch D.

Echo from notch E.

rnd5341141_010.dg, kms/jp, 05/03/99

HORIZONTAL BASELINES

CRT DISPLAY

CRT DISPLAY CRT DISPLAY Transducer Placements and CRT Displays − Distance and Sensitivity Calibration Figure 1 (Sheet 2)

TR 53-128 Page 6of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2

(c) Without further adjustment in sensitivity, move the transducer at Transducer Placement 2 (Refer to Figure 2, Sheet 1) to obtain a maximized amplitude signal from NOTCH A. The distance between the leading edge signals of NOTCHES A and E on the horizontal baseline is defined as the DEFECT WINDOW, as shown in CRT display, Transducer Placements 2, 4 and 6 (Refer to Figure 1, Sheet 2).

(d) Scan the web of the −3 frame sector between the upper and lower flanges, manipulate the transducer and align the front of the transducer with the vertical reference line such that the soundbeam is directed to BL0.00 (Refer to Figure 2, Sheet 1). The maximized signals from NOTCHES A through D shall be equal to or exceed 50% FSH and appear in the DEFECT WINDOW, as shown in CRT display, Transducer Placements 2 through 6 (Refer to Figure 1, Sheet 2).B . Inspection Procedure Refer to Figure 1 and Figure 2.

(1) After equipment calibration as outlined in Para. 5.A., use a removable trace marker to draw two vertical references lines on the web surfaces of the left and right−side lateral beam at FS513.00 near LBL3.10 and RBL3.10, from the most outboard edge of the center joint fitting extending up to the lateral−beams upper−cap flanges (Refer to Figure 2, Sheet 2).

(2) Apply a thin layer of couplant gel on the lateral−beam−web aft surface of the left and right−side lateral beams outboard from the two vertical reference lines (Refer to Figure 2, Sheet 2).

(3) Scan the left and right−side lateral beam webs between the upper and lower cap flanges, manipulate the transducer and align the front of the transducer with the vertical reference lines such that the soundbeam is directed to BL0.00.

(4) Record all indications that have an amplitude signal of 10% FSH or greater and their relative locations on the part for final evaluation.

C. Final Evaluation

(1) Evaluation of indications detected at the initial scan sensitivity:

(a) Couple the transducer on the calibration reference standard E XCM601R30014, Rev. B, manipulate the transducer so that the front of the transducer is as close as possible to the −1 center joint fitting or upper aft joint−angle to obtain a maximized amplitude signal from the EDM notch that corresponds to the fastener location detected on the aircraft (Refer to Figure 1, Sheet 2).

(b) Adjust the GAIN (sensitivity) to obtain a maximized amplitude signal from the notch to 80% FSH.

(c) Couple the transducer back on the aircraft. Manipulate the transducer so that its front is as close as possible to the center joint fitting or to the aft upper joint−angle to obtain a maximized amplitude signal from the indication detected at the initial scan sensitivity (Refer to Figure 2, Sheet 2).

TR 53-128 Page 7of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2 A WL 69.00

VIEW LOOKING FORWARD AT FS 513.00 A B B FS 513.00 C −B B rnd5341182_001.dg, jp/rm, 18/04/00 AFT

EXAMINE THE

SHADED AREA WL 69.00

FORWARD UPPER JOINT−ANGLE

LOWER JOINT ANGLE

CENTER JOINT

FITTING

LATERAL

BEAM WEB

AFT UPPER JOINT−ANGLE (REF) (REF)

LOWER CAP FLANGE

UPPER CAP FLANGE

LATERAL BEAM FRAME SECTOR (TWO PLACES)

FASTENER HEADS (TYPICAL)

REINFORCING STRAP COLLAR (TYPICAL) SUPPORT−BEAM

ATTACHMRNT

FLANGES (REF) BL 0.00 1 Hydraulic support beam omitted for clarity.

LEGEND 1 Inspection of the Lateral Beam (Frame Sector) Web on Frame FS513.00, Between LBL3.10 and RBL3.10 Figure 2 (Sheet 1)

TR 53-128 Page 8of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2 rnd5341182_002.dg, kms/jp, 08/06/00 LBL 3.10 BL 0.00 RBL 3.10

AFT UPPER JOINT−ANGLE (REF)

CENTER JOINT

FITTING

UPPER CAP FLANGE (TWO PLACES)

TRANSDUCER

SCAN PATH (TYPICAL LEFT AND

RIGHT SIDE)

LIMIT OF SCAN (AT INITIAL

SCAN SENSITIVITY)

VIEW LOOKING FORWARD C

VERTICAL

REFERENCE LINE

LOWER CAP FLANGE (TWO PLACES)

REINFORCING STRAP

VERTICAL

REFERENCE LINE Inspection of the Lateral Beam (Frame Sector) Web on Frame FS513.00, Between LBL3.10 and RBL3.10 Figure 2 (Sheet 2)

TR 53-128 Page 9of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2 D. Acceptance or Rejection Criteria

(1) Any distinct indications with an amplitude signal of 20% FSH or greater at the final evaluation sensitivity is cause for rejection.

(2) Record and report results in accordance with company guidelines and policies.

(3) For indications that exceed the allowable limits, it is recommended that you contact MHIRJ Customer Support (refer to SRM 51−13−01).

6. Inspection for Subsurface Cracks in the Lateral Beam (Lower Flange) at the 2nd and 3rd Fasteners Outboard of BL0.00 A. Equipment Calibration Refer to Figure 3 and Figure 4.

(1) Remove the transducer PAB−0504 and connect the transducer VM 7−121−TC−A to the ultrasonic instrument with the coaxial cable.

(2) Turn the power ON and set the instrument to pulse−echo test mode and 5 MHz test frequency.

(3) Apply a thin even layer of couplant gel on −3 and −4 frame sectors of the calibration reference standard EXCM601R30038 adjacent to both ends of the −5 lower joint angle and −6 center joint fitting where the transducer will be placed for calibration (Refer to Figure 3).

(4) Do the distance calibration on the reference calibration standard as follows (Refer to Figure 4, Sheet 1):

(a) Couple the transducer to the −3 frame sector of the calibration reference standard EXCM601R30038 with the front of the transducer against the −6 center joint fitting between the two rows of fasteners and the soundbeam directed to BL0.00 reference line, as shown in Transducer Placement 1.

(b) Adjust the instrument GAIN as necessary to obtain a clear first back reflection signal approximately 40% full screen height (FSH) from the edge of end of the part (EOP) −3 frame sector near BL0.00, see CRT display, Distance Calibration.

(c) Use the DELAY and RANGE controls to set the leading edge of the first edge reflection signal at 90% of the horizontal limit on the baseline, as shown in CRT display, Distance Calibration.

(5) Do the sensitivity calibration on the reference calibration standard as follows (Refer to Figure 4, Sheet 2):

(a) Slide the transducer with the front edge against the end of the −6 center joint fitting such that the soundbeam is directed to NOTCH A, as shown in Transducer Placement 2.

(b) Swivel the transducer to obtain a maximized amplitude reflection signal from NOTCH A and adjust the GAIN control to obtain a 100% FSH signal from NOTCH A, as shown in CRT display, Sensitivity Calibration.

(c) Without further adjustment, slide the front of the transducer along the edge of the −5 lower joint angle such that the soundbeam is directed to the NOTCH B, as shown in Transducer Placement 3.

TR 53-128 Page 10of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2 −5 LOWER JOINT ANGLE −6 CENTER JOINT

FITTING −3 FRAME SECTOR (REF) FS 513.00 (REF) −4 FRAME SECTOR −3 FRAME SECTOR −7 REINFORCING STRAP

0.060 in. (1.52 mm)

MAXIMUM GAP BETWEEN −3 AND −4 BL 0.00 (REF) rnd5341182_004.dg, jp/rm, 14/04/00 EE Calibration Reference Standard EXCM601R 30038 Figure 3

TR 53-128 Page 11of 19 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−41−182 EFFECTIVITY: SEE PARAGRAPH 2 FS 513.00 (REF) BL 0.00 (REF) 51 00 50 100 NOTES

CRT DISPLAY

TRANSDUCER PLACEMENT 1 −3 FRAME SECTOR EOP−3 EOPS FROM−3 IP

DISTANCE

CALIBRATION REFERENCE STANDARD EXCM601R30038

AND TRANSDUCER

PLACEMENT

DISTANCE CALIBRATION IP = Initial Pulse.

EOPS = Edge of Part Signal.

ENA = Echo from Notch A in −4 frame sector.

ENB = Echo from Notch B in −4 frame sector.

rnd5341182_005.dg, jp/rm, 07/06/00

SIGNAL AMPLITUDE

BASELINE −6 CENTER JOINT

FITTING −5 LOWER JOINT ANGLE −4 FRAME SECTOR Transducer Placement and Calibration Figure 4 (Sheet 1)

TR 53-128 Page 12of 19 Sep 15/23

Pages 13–19 of 19