Service bulletin · Hamilton Sundstrand

Revision 1U.S. DOT/FAA - Service Bulletin - Hamilton Sundstrand ASB JFC131-2-73-A24_R1 · 18 pages · 687 KB

© Hamilton Sundstrand Corporation. Filed by the FAA in regulations.gov docket FAA-2011-0944; AD 2012-04-04 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

Docket FAA-2011-0944 (document 0009) · AD 2012-04-04

Type
Alert Service Bulletin
Number
JFC131-2-73-A24
Latest revision known
JFC131-2-73-A24, Revision 1, dated May 18, 2011

A newer revision may exist than any OpenAirDocs knows of: check with the manufacturer.

On this page

ADs that cite it · 1

Newest first, with the revision each names, as OpenAirDocs read it from the AD’s text: check it against the AD.

Text · 18OCR

This text is OCR from a scan. OCR can misread letters and numbers. © Hamilton Sundstrand Corporation. Filed by the FAA in regulations.gov docket FAA-2011-0944; AD 2012-04-04 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = '79ae97a97807b3e3193dd8c71f55c83737343ed5796bde2ed05765ba8345b92d'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Page 1OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN ENGINE FUEL AND CONTROL - JFÇ131-2 FUEL METERING UNIT - ADD SPRING TO METERING

VALVE (MV) AND MODIFY CONTROL ORIFICE © 2010, 2011 Hamilton Sundstrand Corporation

PROPRIETARY

THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF HAMILTON SUNDSTRAND CORPORATION (HSC). RECIPIENT AGREES TO HOLD ALL SUCH INFORMATION IN CONFIDENCE AND AGREES IT SHALL BET

USED ONLY FOR RECIPIENT'S INTERNAL PURPOSES TO MAINTAIN RECIPIENT'S EQUIPMENT OR AS MAY OTHERWISE BE PERMITTED IN AN APPLICABLE AGREEMENT BETWEEN RECIPIENT AND HSC. THIS DOCUMENT AND THE INFORMATION

CONTAINED HEREIN SHALL NOT BE USED FOR ANY OTHER PURPOSE, INCLUDING THE CREATION, MANUFACTURE,

DEVELOPMENT, OR DERIVATION OF ANY REPAIRS, MODIFICATIONS, SPARE PARTS, DESIGN, OR CONFIGURATION CHANGES, OR TO OBTAIN FAA OR ANY OTHER GOVERNMENT OR REGULATORY APPROVAL FOR SAME. RECIPIENT AGREES NOT TO

DISCLOSE SUCH INFORMATION TO ANY THIRD PARTY, EXCEPT AS MAY OTHERWISE BE PROVIDED FOR IN AN APPLICABLE AGREEMENT BETWEEN RECIPIENT AND HSC. COPYING OR DISCLOSURE OF THIS DOCUMENT AND THE INFORMATION

CONTAINED HEREIN BY ANYONE WITHOUT HSC'S PRIOR WRITTEN PERMISSION IS NOT AUTHORIZED AND MAY RESULT IN CRIMINAL AND/OR CIVIL LIABILITY.

INFORMATION SUBJECT TO EXPORT CONTROL LAWS

THE TECHNICAL DATA IN THIS DOCUMENT (OR FILE) IS CONTROLLED FOR EXPORT UNDER THE EXPORT ADMINISTRATION REGULATIONS (EAR), 15 CFR PARTS 730-774. VIOLATIONS OF THESE LAWS MAY BE SUBJECT TO FINES AND PENALTIES UNDER THE EXPORT ADMINISTRATION ACT.

EAR EXPORT CLASSIFICATION: ECCN 9E991

THE DATA IN THIS DOCUMENT WERE DEVELOPED ONLY TO MAINTAIN SYSTEMS AND/OR PARTS MANUFACTURED BY OR FOR HAMILTON SUNDSTRAND OR APPROVED BY HAMILTON SUNDSTRAND. THE DATA MAY NOT BE APPLICABLE TO ANY OTHER T

SYSTEMS AND/OR PARTS, REGARDLESS OF THEIR APPARENT SIMILARITY TO SYSTEMS ANDIOR PARTS MANUFACTURED BYT OR FOR HAMILTON SUNDSTRAND OR APPROVED BY HAMILTON SUNDSTRAND. DO NOT RELY IN ANY WAY ON DATA IN THIS

DOCUMENT TO MAINTAIN OR OTHERWISE SUPPORT SYSTEMS AND/OR PARTS THAT WERE NOT MANUFACTURED BY OR FOR

HAMILTON SUNDSTRAND OR APPROVED BY HAMILTON SUNDSTRAND WITHOUT EVIDENCE THAT THE FEDERAL AVIATION

ADMINISTRATION OR OTHER REGULATORY AGENCY HAS DETERMINED THAT THE DATA IN THIS DOCUMENT IS VALID FOR SUCH USE.

HAMILTON SUNDSTRAND ASSUMES NO LIABILITY WHATSOEVER, WHETHER CONTRACTUAL, WARRANTY, TORT OR

OTHERWISE, FOR UNAUTHORIZED ALTERATION OR ALTERATIONS NOT PERFORMED IN ACCORDANCE WITH HAMILTON SUNDSTRAND APPROVED PROCEDURES.

REVISIONS Revision 1 This revision changes the compliance code and statement and adds a note on page 3.

Units previously modified according to this bulletin do not require remodification according to this bulletin revision.

This bulletin has been reproduced in its entirety. Discard the bulletin you now have and replace it with this copy. The tabulation below is provided for record keeping and traceability of bulletin issues.

Issue Date Basic Oct 21/10 Revision 1 May 18/11 Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 1 of 18

Page 2OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN

1. PLANNING INFORMATION A. Effectivity

(1) Refer to Table 1.

Table 1 Effective Parts Model Hamilton Sundstrand JFC131-2 Fuel Serial Number Of First Metering Units Not Incorporating Part Production Number Incorporation JFC131-2 801000-4 None at this time. No production unit incorporating this modification has been shipped at the time of publication.

NOTE: All JFC131-2 Fuel Metering Units used on Boeing 747, 767 and McDonnell Douglas MD11, Airbus A300 and A310 aircraft that have Pratt and Whitney PW4000 Series Engines.

NOTE: Part Numbers 801000-1 and 801000-2 would need to be upgraded to part number 801000-3 prior to the accomplishment of this Service Bulletin.

Accomplish by referencing Hamilton Sundstrand Service Bulletins JFC131-2-73-7 and JFC131-2-73-9 as applicable.

B. Concurrent Requirements

(1) None C. Reason

(1) Problem

(a) The JFC131-2 Fuel Metering Unit (FMU) has been determined to be susceptible to a single point failure condition in which complete or nearly complete blockage of the FMU Servo Wash Filter can result in insufficient hydraulic pressure being available to properly control the FMU and Actuator functions.

(2) Cause

(a) Investigation of a JFC131-2 FMU field return determined that complete or nearly complete blockage of the FMU Servo Wash Filter resulted in the loss of Metering Valve position control. The loss of control allowed the Metering Valve to be driver to a higher than intended fuel flow.

I Ise or disclosure of thie data in subient to restrintions on the front page of thie document Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 2

Page 3OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN

(3) Solution

(a) A new FMU modification has been defined which will properly position the Metering Valve in the event of a hydraulic pressure loss. The revised design incorporates an additional spring, associated spring mounting hardware, and a Metering Valve Piston modification which will force the Metering Valve Piston to the Minimum Flow stop in the event that Servo Fuel Muscle Pressure is lost. It also provides a set of revised Wf Flapper Fixed /Accel Rate Limiting Orifices of different flow ranges to compensate for the inclusion of the new Spring and to maintain FMU system dynamics within the intended design limits.

(4) Substantiation

(a) The redesigned JFC131-2 FMU is substantiated in accordance with the FAA 36- Item Component Checklist.

D. Description

(1) This Service Bulletin provides instructions to incorporate new JFC131-2 part number 801000-4.

E. Compliance

(1) Category 4 - Do this service bulletin the first time the fuel metering unit is at a maintenance base that can do the procedures regardless of other planned maintenance action.

NOTE: Accomplishment criteria includes the next engine shop visit. Fuel metering units installed on engines inducted for their next maintenance shop visit are to be removed and modified in accordance with this service bulletin.

F. Approval

(1) The repairs or modifications herein have been shown to comply with the applicable Federal Aviation Regulations and are FAA approved for the JFC131-2 Fuel Metering Units listed.

G. Manpower

(1) Approximately 2.0 man-hours are necessary to do this Service Bulletin when it is done during normal component maintenance.

Use or disclosure of this date is sabject to rectrictions or the for page of this document Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 3

Page 4OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN H. Weight and Balance

(1) None I. Electrical Load Data

(1) None J. Software Accomplishment Summary

(1) Not Applicable K. References

(1) Hamilton Sundstrand JFC131-2 FMU Component Maintenance Manual (CMM) 73-21- 64, Revision 7 or later.

(2) Hamilton Sundstrand Standard Practices Manual (SPM) 20-00-01.

Other Publications Affected

(1) The release of Hamilton Sundstrand JFC131-2 FMU CMM 73-21-64, Revision 7, will incorporate the information within this Service Bulletin.

M. Interchangeability or Intermixability of Parts

(1) The incorporation of this bulletin does not affect the interchangeability or intermixability of the JFC131-2 FUEL METERING UNIT.

2. MATERIAL INFORMATION A. Material - Price and Availability

(1) See paragraph 2.C. and Table 2 for details.

B. Industry Support Information

(1) Commercial Policy defined in Hamilton Sundstrand Service Information Release (SIR) JFC131-2:005. This Commercial Policy will expire upon incorporation of this Service Bulletin in all JFC131-2 FMU's or by December 31, 2015, whichever occurs first.

Usp or disclosure of this data in subject to rectritions on the front page of this document Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 4

Page 5OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN C. Material Necessary For Each Unit

(1) Material to be Purchased

(a) The parts that are necessary to do this Service Bulletin can be obtained by ordering either Parts Kit part number K28837 or K28791, and the individual Orifice Assembly part numbers. See Table 2 for details.

(b) In Table 2, the "Key Word" is the name of the part.

(c) The Purchase Order requests for parts should reference this Service Bulletin, JFC131-2-73-A24, and should be addressed to:

Hamilton Sundstrand A United Technologies Company Attention: Manager, Commercial Spares Administration Mail Stop: 236-6 P.O. Box 7002 4747 Harrison Ave.

Rockford, IL 61125-7002 Facsimile: (815) 226-2624 FAA Repair Station License Number SI3R842L Use or disclosure of this date is subject to restrictions on the front page of thie decuman!

Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 5

Page 6OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN Table 2 New Parts Required New Part Keyword Old Part Unit Price Special Instructions/ Number (Notes 1, 2 and 3) Number Qty Disposition 1014354-1 Spring N/A 1 (Note 4) Add 1014548-1 Spring Seat N/A 1 (Note 4) Add 1014387-1 Max Flow Adjustment Screw 786956-1 1 (Note 4) Replace 1014413-1 Orifice Assembly 786015-1 AR (Note 4) Replace 1014413-2 Orifice Assembly 786015-1 AR (Note 4) Replace 1014413-3 Orifice Assembly 786015-1 AR (Note 4) Replace 1014413-4 Orifice Assembly 786015-1 AR (Note 4) Replace 1014413-5 Orifice Assembly 786015-1 AR (Note 4) Replace 1014413-6 Orifice Assembly 786015-1 AR (Note 4) Replace 1014413-7 Orifice Assembly 786015-1 AR (Note 4) Replace 800991-2 Metering Valve 800991-1 1 (Note 4) Replace Table 2 Note 1: The Flapper Fixed Orifice/Accelerated Rate Limiting Orifice Assembly (PN 786015-1) is being replaced with a revised Orifice Assembly (base PN 1014413) selected from a group of seven (7) dash numbered orifices. The different dash number orifices are required to accommodate FMU to FMU tolerance variations. While an analysis indicates the PN 1014413-3 Orifice Assembly is the most likely to yield nominal test results, individual FMU test results will dictate the proper dash number orifice to install.

Table 2 Note 2: Orifice Assemblies should be ordered as individual parts. Order quantities of each Orifice Assembly should be determined in accordance with the maintenance shop support management policies of the individual maintenance facilities.

Table 2 Note 3: Those parts, other than the Orifice Assembly, needed to complete the Service Bulletin modification can be obtained by ordering one of two available Parts Kits.

For new parts only, Parts Kit part number K28837 should be ordered. For new and expendable parts, Parts Kit part number K28791 should be ordered. See Table 3 for a full listing of new parts within Parts Kit part number K28837. See Table 4 for a full listing of new and expendable parts within Parts Kit part number K28791.

Table 2 Note 4: Please refer to Hamilton Sundstrand Service Information Release (SIR) JFC131- 2:005 for the parts price offer information. Contact Hamilton Sundstrand Commeral Opares foi pai pruenna mormation. 10ce paragraph 2 C. en Use or discosure of this date is subject to restrictions orma front page of this document Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 6

Page 7OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN Table 3 Parts Kit Part Number K28837 New Parts (Note: Order Orifice Assemblies as Individual Parts) Part Number Nomenclature Quantity 1014354-1 Spring 1 1014548-1 Spring Seat 1 1014387-1 Max Flow Adjustment Screw 1 800991-2 Metering Valve 1 Table 4 Parts Kit Part Number K28791 New and Expendable Parts (Note: Order Orifice Assemblies as Individual Parts) Part Number Nomenclature Quantity 1014354-1 Spring 1 1014548-1 Spring Seat 1014387-1 Max Flow Adjustment Screw 1 800991-2 Metering Valve 818548-026 Preformed Packing 1 818548-023 Preformed Packing 4 818548-013 Preformed Packing 818548-007 Preformed Packing 2 801094-3 Radial Spacer 1 758901-5 Piston Seal 755347-1 Backup Seal-Triangular 1 69429A26 Backup Ring-Retaining 69429A10 Backup Ring-Retaining 2 69429A7 Backup Ring-Retaining 2 69280-31 Backup Ring-Retaining 69272-28 Cotter Pin Use or disc ete is subject to res the fr nis cocunte Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 7

Page 8OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN Table 4 Parts Kit Part Number K28791 New and Expendable Parts (Note: Order Orifice Assemblies as Individual Parts) (Continued) Part Number Nomenclature Quantity 69259-24 Outer Sleeve Ring M25988/2-906 Packing, Preformed 1 M25988/2-903 Packing, Preformed 1 M25988/2-026 Packing, Preformed M25988/2-010 Packing, Preformed M25988/2-007 Packing, Preformed 1 M25988/2-006 Packing, Preformed 1 Use or disclosure of thie date a subject to restartions on the front page of this document Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 8

Page 9OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN

(2) Material Supplied by the Operator

(a) The same as the material necessary for each unit.

(3) Vendor Services

(a) You can send repair or overhaul orders to these addresses:

Hamilton Sundstrand Worldwide Repair Customer Support Center - Windsor Locks 1 Hamilton Road Dock W Windsor Locks, CT 06096 USA Attention: Contracts Administration FAA Repair Station License Number SI3R842L Hamilton Sundstrand Worldwide Repair Customer Support Center - Maastricht Horsterweg 7 6199 AC Maastricht Airport The Netherlands Attention: Contracts Administration FAA Repair Station License Number CW5Y794M Fuel Accessory Service Technologies - FAST No. 8 Loyang Way 4 Singapore 507604, Republic of Singapore Attention: Contracts Administration FAA Repair Station License Number F3YY247Y Use or disclosure of this dete to subject crestriations or the front page of this docume Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 9

Page 10OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN D. Material Necessary For Each Spare

(1) The same as the material necessary for each unit.

E. Reidentified Parts

(1) The following part numbers are affected by this modification:

Table 5 Reidentified Parts Old Part Number Keyword New Part Number 801000-1* JFC131-2 FMU 801000-4 801000-2* 801000-3 NOTE: *Part numbers 801000-1 and 801000-2 would need to be upgraded to part number 801000-3 prior to the accomplishment of this Service Bulletin.

Accomplish by referencing Hamilton Sundstrand Service Bulletins JFC131- 2-73-7 and JFC131-2-73-9 as applicable.

F. Tooling - Price and Availability

(1) Technical requirements for the tooling necessary to accomplish this Service Bulletin are included in Figure 1 through Figure 5.

3. ACCOMPLISHMENT INSTRUCTIONS A. General

(1) The user should obtain the material safety data sheets [Occupational Safety and Health Act (OSHA) Form 20 or equivalent] from the manufacturers or suppliers of materials to be used. The user must become completely familiar with the manufacturer/ supplier information and adhere to the procedures, recommendations, warnings, and cautions of the manufacturer/supplier for the safe use, handling, storage, and disposal of these materials. The user should also read the long version of the warnings contained in this bulletin. The long version warnings are contained in Hamilton Sundstrand Warnings Registry 341-006 available free of charge to all organizations that are on distribution for this bulletin. The Warnings Registry 341-006 is also available at www.hsvas.com.

B. Disassembly

(1) Disassemble the JFC131-2 in accordance with the DISASSEMBLY section of Component Maintenance Manual (MIM) 73-21-64. Gain access to and remove the metering valve part number 800991-1.

Use or disclostire of thie date in aubiect to page of the document Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 10

Page 11OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN C. Assembly

(1) Assemble the Metering Valve (MV) into the FMU in accordance with the following instructions:

NOTE: The introduction of the modified Metering Valve assembly, PN 800991-2, will result in a change to the existing installation tooling, the seal installer, GS21456-1, and seal pusher, GS21457-1. Figure 5, tool Detail 5 a and b, contains the technical information for the new seal installer (a) and new seal pusher (b) tool. This tool should be utilized for the installation of the Metering Valve assembly, PN 800991-2.

(a) Reference JFC131-2 CMM 73-21-64, ASSEMBLY section, Part 5. Accomplish all work in accordance with Part 5, up to paragraph 5. J. (8). Replace the instructions of paragraph 5. J. (8) with paragraph (b) below, and then continue with the subsequent assembly instructions.

(b) Remove compressor/sleeve (CMM 73-21-64, IPL Figure 5, Item 80)/spool (70) assembly from dry ice. Remove MV spool (70) and sleeve (80) from seal compressor, GS21455-1. Install the MV installation rod (Figure 3, tool Detail 3) by hand into the threaded hole in the end of the spool (70). Place the spring seat (PN 1014548-1) on the spring (PN 1014354-1), install assembled spring and seat over tool Detail 3 (open spring end over rod first).

CAUTION: ENSURE HOLDING ACTION OF MV SLEEVE AND SPOOL INSTALLER (FIGURE 2, TOOL DETAIL 2) IS CONSTANT DURING FOLLOWING PROCEDURE.

(c) Position and secure the FMU housing (370) with the MV bore on a horizontal plane. Using alignment marks on FMU housing (370) and sleeve (80), install MV assembly (60), with spring and seat and tool Detail 3 attached, into MV bore.

Using tool Detail 2, engage the ears on the top of the MV sleeve (80), and then pushing in with the tool, ensure the MV sleeve (80) and spool (70) is at the bottom of the bore.

(d) While holding MV in position with tool Detail 2, install MV maximum flow stop sleeve (Figure 1, tool Detail 1), small diameter boss end first, over top of tool Detail 3, which is now protruding out from the maximum flow adjusting screw bore.

Position tool Detail 1 to contact top of bore.

(e) Position the MV installation rod clip (Figure 4, tool Detail 4) through its open end and ensure it is completely seated on the smaller diameter section of tool Detail

3. The side of tool Detail 4 should be up against the end of tool Detail 1. Retain tool Detail 4 by installing a 0.125 inch (3.175mm) headed straight pin (shop supplied), minimum 1.0 inch in length, in the through - hole at the end of tool Detail

4. Release hold on tool Detaii 2, but maintain tooi position.

Joe di disclosure of the vata to subjed ta restatoro or the from paye vi tia dutdren.

Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 11

Page 12OCROpen in PDF

Hamilton Sundstrand A United Technologies Company

ALERT SERVICE BULLETIN

(f) With tool Detail 2 still positioned on the MV sleeve (80), rotate to align the slot on side of tool Detail 2 with the position of the hole boss for the MV anti-rotation headless straight pin (CMM 73-21-64, IPL Figure 4, Item 40). Ensure internal alignment position of the MV exists by installing a 0.125 inch (3.175mm) headed straight pin (shop supplied), minimum 1.0 inch in length, in the MV anti-rotation pin hole. Once it has been aligned properly, remove the 0.125 inch (3.175mm) headed straight pin from the MV anti-rotation pin hole, and then remove tool Detail

2.

(g) Continue in accordance with ASSEMBLY section of CMM 73-21-64, Part 4, except do not accomplish paragraphs 6.B. and 6.C. until directed to do so in step

(i) below.

(h) Prior to accomplishing ASSEMBLY section of CMM 73-21-64, Part 3, remove the

0.125 inch (3.175mm) headed straight pin from tool Detail 4, and then remove tool Detail 4 from its position by pulling it away from tool Detail 3. Remove tool Detail 1 from tool Detail 3, and then remove tool Detail 3 by hand, unscrewing the tool from the MV spool (70).

Reference ASSEMBLY section of CMM 73-21-64, Part 4, paragraph 6. B. and 6.

C, utilize process instructions to order and install a new Maximum Flow Rate Adjustment Screw (PN 1014387-1, reference CMM 73-21-64, IPL Figure 5, Item NOTE: The Flapper Fixed Orifice/Accelerated Rate Limiting Orifice Assembly is being replaced with a revised Orifice Assembly selected from a group of seven (7) dash numbered orifices. The different dash number orifices are required to accommodate FMU to FMU tolerance variations. While an analysis indicates the PN 1014413-3 Orifice Assembly is the most likely to yield nominal test results, individual FMU test results will dictate the proper dash number orifice to install.

Reference ASSEMBLY section of CMM 73-21-64, Part 7, paragraph 3. C., utilize process instructions to order and install a new Flapper Fixed Orifice/Acceleration Rate Limiting Orifice (Orifice Assembly) (PN 1014413-3, reference CMM 73-21- 64, IPL Figure 7, Item 300C).

Uạe or disclacue of thic data in eubiert to restrictions on the frent nage of thie document Original Issue Date: Oct 21/10 JFC131-2-73-A24 Revision 1: May 18/11 Page 12