KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622

Transmittal Sheet Summary This service bulletin provides a b ench test procedure for Continuous Fire Detector (CFD) sensing elements to verify proper operation. Failed units will be replaced by Kidde Aerospace and Defense.

NOTE: This Service Bulletin is classified under Chapter 26 due to the initial classification of the CFD product line. Airbus classifies the O verheat Detection System (OHDS) as Sensing Elements under Chapter 36. CFD's and OHDS Sensing Elements reference the same product.

Service Bulletin Revision History

REVISION DATE OF RELEASE Initial Release (IR) January 13, 2022

Subject to the EAR, ECCN 9E991 .

The data in this document were developed only to maintain systems and/or parts manufactured by or for Collins Aerospace or approved by Collins Aerospace. The data may not be applicable to any other systems and/or parts, regardless of their apparent similarity to systems and/or parts manufactured by or for Collins Aerospace or approved by Collins Aerospace.

Do not rely in any way on data in this document to maintain or otherwise support systems and/or parts that wer e not manufactured by or for Collins Aerospace or approved by Collins Aerospace without evidence that the Federal Aviation Administration or other regulatory agency has determined that the data in this document is valid for such use.

Collins Aerospace ass umes no liability whatsoever, whether contractual, warranty, tort or otherwise, for unauthorized alteration or alterations not performed in accordance with Collins Aerospace approved procedures.

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 1 of 30

1. PLANNING INFORMATION A. Effectivity This Service Bulletin (SB) is applicable for CFD (sensing elements) Units.

PART NUMBER APPLICABLE TO

DATE CODE

PART NUMBER APPLICABLE TO

DATE CODE

PART NUMBER APPLICABLE TO

DATE CODE 04-195006-001 Before A2105 04-90014-9186A Before A2105 04-90014-9268A Before A2105 04-195007-001 Before A2105 04-90014-9187A Before A2105 04-90014-9269A Before A2105 04-90014-9088A Before A2105 04-90014-9190A Before A2105 04-90014-9271A Before A2105 04-90014-9098A Before A2105 04-90014-9195A Before A2105 04-90014-9272A Before A2105 04-90014-9099A Before A2105 04-90014-9196A Before A2105 04-90014-9274A Before A2105 04-90014-9102A Before A2105 04-90014-9197A Before A2105 04-90014-9275A Before A2105 04-90014-9113A Before A2105 04-90014-9198A Before A2105 04-90014-9277A Before A2105 04-90014-9115A Before A2105 04-90014-9200A Before A2105 04-90014-9280A Before A2105 04-90014-9117A Before A2105 04-90014-9202A Before A2105 04-90014-9281A Before A2105 04-90014-9119A Before A2105 04-90014-9203A Before A2105 04-90014-9283A Before A2105 04-90014-9120A Before A2105 04-90014-9204A Before A2105 04-90014-9284A Before A2105 04-90014-9121A Before A2105 04-90014-9208A Before A2105 04-90014-9286A Before A2105 04-90014-9122A Before A2105 04-90014-9209A Before A2105 04-90014-9287A Before A2105 04-90014-9126A Before A2105 04-90014-9211A Before A2105 04-90014-9288A Before A2105 04-90014-9130A Before A2105 04-90014-9212A Before A2105 04-90014-9289A Before A2105 04-90014-9134A Before A2105 04-90014-9213A Before A2105 04-90014-9295A Before A2105 04-90014-9136A Before A2105 04-90014-9215A Before A2105 04-90014-9305A Before A2105 04-90014-9137A Before A2105 04-90014-9216A Before A2105 04-90014-9310A Before A2105 04-90014-9140A Before A2105 04-90014-9217A Before A2105 04-90014-9312A Before A2105 04-90014-9142A Before A2105 04-90014-9218A Before A2105 04-90014-9314A Before A2105 04-90014-9143A Before A2105 04-90014-9228A Before A2105 04-90014-9318A Before A2105 04-90014-9145A Before A2105 04-90014-9234A Before A2105 04-90014-9320A Before A2105 04-90014-9147A Before A2105 04-90014-9236A Before A2105 04-90014-9321A Before A2105 04-90014-9148A Before A2105 04-90014-9237A Before A2105 04-90014-9323A Before A2105 04-90014-9149A Before A2105 04-90014-9238A Before A2105 04-90014-9324A Before A2105 04-90014-9150A Before A2105 04-90014-9239A Before A2105 04-90014-9325A Before A2105 04-90014-9151A Before A2105 04-90014-9240A Before A2105 04-90014-9328A Before A2105 04-90014-9152A Before A2105 04-90014-9241A Before A2105 04-90014-9332A Before A2105 04-90014-9155A Before A2105 04-90014-9242A Before A2105 04-90014-9339A Before A2105 04-90014-9158A Before A2105 04-90014-9243A Before A2105 04-90014-9348A Before A2105 04-90014-9165A Before A2105 04-90014-9244A Before A2105 04-90014-9351A Before A2105 04-90014-9166A Before A2105 04-90014-9245A Before A2105 04-90014-9361A Before A2105 04-90014-9167A Before A2105 04-90014-9246A Before A2105 04-90014-9363A Before A2105 04-90014-9168A Before A2105 04-90014-9248A Before A2105 04-90016-901 Before A2105 04-90014-9169A Before A2105 04-90014-9251A Before A2105 04-90016-902 Before A2105 04-90014-9170A Before A2105 04-90014-9252A Before A2105 1002008-051C Before A2105 04-90014-9171A Before A2105 04-90014-9253A Before A2105 1004008-046D Before A2105 04-90014-9172A Before A2105 04-90014-9254A Before A2105 1005008-046D Before A2105 04-90014-9173A Before A2105 04-90014-9256A Before A2105 1070001-217A00 Before A2105 04-90014-9175A Before A2105 04-90014-9257A Before A2105 1070001-221A00 Before A2105 04-90014-9176A Before A2105 04-90014-9258A Before A2105 1072001-041A00 Before A2105 04-90014-9180A Before A2105 04-90014-9259A Before A2105 1072001-041M00 Before A2105 04-90014-9181A Before A2105 04-90014-9263A Before A2105 1072001-044A00 Before A2105 04-90014-9183A Before A2105 04-90014-9264A Before A2105 1072001-044M00 Before A2105 04-90014-9184A Before A2105 04-90014-9267A Before A2105 1072001-046M00 Before A2105

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 2 of 30

PART NUMBER APPLICABLE TO

DATE CODE

PART NUMBER APPLICABLE TO

DATE CODE

PART NUMBER APPLICABLE TO

DATE CODE 1072001-055A00 Before A2105 1072001-173A00 Before A2105 1072001-245A51 Before A2105 1072001-059A00 Before A2105 1072001-173A51 Before A2105 1072001-247A00 Before A2105 1072001-072A00 Before A2105 1072001-185A00 Before A2105 1072001-247A51 Before A2105 1072001-075A51 Before A2105 1072001-186A00 Before A2105 1072001-248A00 Before A2105 1072001-078A00 Before A2105 1072001-186A51 Before A2105 1072001-248A51 Before A2105 1072001-080A00 Before A2105 1072001-188A00 Before A2105 1072001-250A95 Before A2105 1072001-080A51 Before A2105 1072001-191A00 Before A2105 1072001-251A00 Before A2105 1072001-086A00 Before A2105 1072001-197A00 Before A2105 1072001-251A51 Before A2105 1072001-086A51 Before A2105 1072001-197A51 Before A2105 1072001-255A00 Before A2105 1072001-087A00 Before A2105 1072001-200A00 Before A2105 1072001-255A51 Before A2105 1072001-087A51 Before A2105 1072001-200A51 Before A2105 1072001-256A00 Before A2105 1072001-090A00 Before A2105 1072001-201A00 Before A2105 1072001-256A51 Before A2105 1072001-090A51 Before A2105 1072001-205A00 Before A2105 1072001-260A95 Before A2105 1072001-091A00 Before A2105 1072001-205A51 Before A2105 1072001-262A00 Before A2105 1072001-091A51 Before A2105 1072001-206A00 Before A2105 1072001-262A51 Before A2105 1072001-097A51 Before A2105 1072001-206A51 Before A2105 1072001-263A95 Before A2105 1072001-105A51 Before A2105 1072001-209A00 Before A2105 1072001-270A00 Before A2105 1072001-121A00 Before A2105 1072001-209A51 Before A2105 1072001-270A51 Before A2105 1072001-121A51 Before A2105 1072001-210A00 Before A2105 1072001-277A95 Before A2105 1072001-126A95 Before A2105 1072001-210A51 Before A2105 1072001-285A00 Before A2105 1072001-129A00 Before A2105 1072001-212A00 Before A2105 1072001-286A95 Before A2105 1072001-129A51 Before A2105 1072001-212A51 Before A2105 1072001-287A95 Before A2105 1072001-131A00 Before A2105 1072001-213A00 Before A2105 1072001-291A00 Before A2105 1072001-131A51 Before A2105 1072001-213A51 Before A2105 1072001-297A00 Before A2105 1072001-134A00 Before A2105 1072001-215A00 Before A2105 1072001-297A51 Before A2105 1072001-134A51 Before A2105 1072001-215A51 Before A2105 1072001-317A95 Before A2105 1072001-136A95 Before A2105 1072001-217A51 Before A2105 1072001-319A00 Before A2105 1072001-137A00 Before A2105 1072001-218A00 Before A2105 1072001-319A51 Before A2105 1072001-140A00 Before A2105 1072001-218A51 Before A2105 1072001-323A00 Before A2105 1072001-140A51 Before A2105 1072001-219A00 Before A2105 1072001-323A51 Before A2105 1072001-142A00 Before A2105 1072001-219A51 Before A2105 1072001-328A00 Before A2105 1072001-149C00 Before A2105 1072001-221A00 Before A2105 1072001-328A51 Before A2105 1072001-149C01 Before A2105 1072001-221A51 Before A2105 1072001-A049-51 Before A2105 1072001-149C51 Before A2105 1072001-222A00 Before A2105 1072001-A051-51 Before A2105 1072001-151A95 Before A2105 1072001-222A51 Before A2105 1072001-A075-51 Before A2105 1072001-152A00 Before A2105 1072001-223A00 Before A2105 1072001-A098-51 Before A2105 1072001-152A51 Before A2105 1072001-223A51 Before A2105 1072001-A100-51 Before A2105 1072001-152C51 Before A2105 1072001-229A00 Before A2105 1072001-A115-51 Before A2105 1072001-156C01 Before A2105 1072001-229A51 Before A2105 1072001-A120-51 Before A2105 1072001-158A95 Before A2105 1072001-230A00 Before A2105 1072001-A123-51 Before A2105 1072001-159A00 Before A2105 1072001-234A00 Before A2105 1072001-A126-51 Before A2105 1072001-161C00 Before A2105 1072001-234A51 Before A2105 1072001-A136-51 Before A2105 1072001-161C01 Before A2105 1072001-238A00 Before A2105 1072001-A139-51 Before A2105 1072001-161C51 Before A2105 1072001-238A51 Before A2105 1072001-A141-51 Before A2105 1072001-162A00 Before A2105 1072001-240A00 Before A2105 1072001-A151-51 Before A2105 1072001-162A51 Before A2105 1072001-240A51 Before A2105 1072001-A154-51 Before A2105 1072001-163A00 Before A2105 1072001-242A95 Before A2105 1072001-A158-51 Before A2105 1072001-163A51 Before A2105 1072001-243A00 Before A2105 1072001-A162-51 Before A2105 1072001-166A00 Before A2105 1072001-243A51 Before A2105 1072001-A168-51 Before A2105 1072001-166A51 Before A2105 1072001-244A95 Before A2105 1072001-A170-51 Before A2105 1072001-168A95 Before A2105 1072001-245A00 Before A2105 1072001-A171-51 Before A2105

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 3 of 30

PART NUMBER APPLICABLE TO

DATE CODE

PART NUMBER APPLICABLE TO

DATE CODE

PART NUMBER APPLICABLE TO

DATE CODE 1072001-A179-51 Before A2105 35546-2-255 Before A2105 35596-2-310 Before A2105 1072001-A182-51 Before A2105 35546-2-310 Before A2105 35597-2-255 Before A2105 1072001-A183-51 Before A2105 35548-2-255 Before A2105 35597-3-255 Before A2105 1072001-A189-51 Before A2105 35549-2-255 Before A2105 35598-2-255 Before A2105 1072001-A192-51 Before A2105 35551-2-255 Before A2105 35599-2-255 Before A2105 1072001-A195-51 Before A2105 35552-2-255 Before A2105 35599-2-310 Before A2105 1072001-A199-51 Before A2105 35553-2-255 Before A2105 35599-2-310 Before A2105 1072001-A203-51 Before A2105 35554-2-255 Before A2105 35599-3-255 Before A2105 1072001-A215-51 Before A2105 35554-4-255 Before A2105 35600-2-255 Before A2105 1072001-A223-51 Before A2105 35556-2-255 Before A2105 35601-2-255 Before A2105 1072001-A225-51 Before A2105 35557-2-255 Before A2105 35601-2-310 Before A2105 1072001-A233-51 Before A2105 35558-2-255 Before A2105 35602-2-255 Before A2105 1072001-A234-51 Before A2105 35558-2-310 Before A2105 35603-2-255 Before A2105 1072001-A236-51 Before A2105 35560-2-255 Before A2105 35604-2-255 Before A2105 1072001-A237-51 Before A2105 35561-2-255 Before A2105 35605-2-255 Before A2105 1072001-A238-51 Before A2105 35562-2-255 Before A2105 35606-2-255 Before A2105 1072001-A240-51 Before A2105 35563-2-255 Before A2105 35607-2-255 Before A2105 1072001-A241-51 Before A2105 35566-2-255 Before A2105 35609-2-255 Before A2105 1072001-A242-51 Before A2105 35566-2-310 Before A2105 35610-2-255 Before A2105 1072001-A247-51 Before A2105 35567-2-255 Before A2105 35611-2-255 Before A2105 1072001-A250-51 Before A2105 35567-3-255 Before A2105 35611-3-255 Before A2105 1072001-A258-51 Before A2105 35568-2-255 Before A2105 35612-2-255 Before A2105 1072001-A259-51 Before A2105 35568-4-255 Before A2105 35614-2-255 Before A2105 1072001-A260-51 Before A2105 35569-2-255 Before A2105 35615-2-255 Before A2105 1072001-A263-51 Before A2105 35571-2-255 Before A2105 35616-2-255 Before A2105 1072001-A270-51 Before A2105 35572-2-255 Before A2105 35617-2-255 Before A2105 1072001-A286-51 Before A2105 35573-2-255 Before A2105 35618-2-255 Before A2105 1072001-A287-51 Before A2105 35574-2-255 Before A2105 35619-2-255 Before A2105 1072001-A306-51 Before A2105 35575-2-255 Before A2105 35620-2-255 Before A2105 1072001-A308-51 Before A2105 35576-2-255 Before A2105 35621-2-255 Before A2105 1072001-A317-51 Before A2105 35577-2-255 Before A2105 35622-2-255 Before A2105 1072001-A326-51 Before A2105 35579-2-255 Before A2105 35622-4-310 Before A2105 1072001-A342-51 Before A2105 35580-2-255 Before A2105 35623-2-255 Before A2105 1072001-C149-51 Before A2105 35581-2-255 Before A2105 35624-2-255 Before A2105 1072001-C152-51 Before A2105 35582-2-255 Before A2105 35624-2-310 Before A2105 1094006-046 Before A2105 35583-2-255 Before A2105 35625-2-255 Before A2105 1095006-046 Before A2105 35584-2-255 Before A2105 35626-2-255 Before A2105 35518-48-400 Before A2105 35584-3-255 Before A2105 35627-2-255 Before A2105 35522-2-255 Before A2105 35586-2-255 Before A2105 35628-2-255 Before A2105 35523-2-255 Before A2105 35587-2-255 Before A2105 35629-2-255 Before A2105 35524-2-255 Before A2105 35588-2-255 Before A2105 35630-2-255 Before A2105 35525-2-255 Before A2105 35589-2-255 Before A2105 35631-2-255 Before A2105 35526-2-255 Before A2105 35590-2-255 Before A2105 35632-2-255 Before A2105 35527-2-255 Before A2105 35591-2-255 Before A2105 35633-2-255 Before A2105 35528-2-255 Before A2105 35592-2-310 Before A2105 35634-2-255 Before A2105 35532-2-255 Before A2105 35593-2-255 Before A2105 35636-2-255 Before A2105 35532-2-310 Before A2105 35593-3-255 Before A2105 35636-2-310 Before A2105 35535-2-255 Before A2105 35594-2-255 Before A2105 35637-2-310 Before A2105 35535-2-310 Before A2105 35594-2-310 Before A2105 35637-3-255 Before A2105 35537-2-255 Before A2105 35595-2-255 Before A2105 35638-2-255 Before A2105 35545-2-310 Before A2105 35596-2-255 Before A2105 35639-2-255 Before A2105

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 4 of 30

PART NUMBER APPLICABLE TO

DATE CODE

PART NUMBER APPLICABLE TO

DATE CODE

PART NUMBER APPLICABLE TO

DATE CODE 35640-2-255 Before A2105 35661-2-310 Before A2105 35774-200-255 Before A2105 35641-3-255 Before A2105 35663-2-255 Before A2105 35777-200-255 Before A2105 35642-2-255 Before A2105 35665-2-255 Before A2105 35778-200-255 Before A2105 35643-2-255 Before A2105 35666-3-310 Before A2105 35780-200-255 Before A2105 35647-2-255 Before A2105 35667-2-255 Before A2105 35781-200-255 Before A2105 35650-2-255 Before A2105 35668-2-255 Before A2105 35784-200-255 Before A2105 35654-2-255 Before A2105 35668-2-310 Before A2105 35795-200-255 Before A2105 35655-2-255 Before A2105 35670-2-255 Before A2105 35796-200-255 Before A2105 35658-2-255 Before A2105 35673-2-255 Before A2105 35798-200-255 Before A2105 35658-2-310 Before A2105 35677-2-255 Before A2105 35808-200-255 Before A2105 35659-3-310 Before A2105 35680-2-255 Before A2105 35812-200-255 Before A2105 35660-2-310 Before A2105 35687-2-255 Before A2105

NOTE: Numeric Date Code: AYYWW (YY 2 -digit year, WW 2-digit Week) Example A2105 (Date of Manufacture 5th week of 2021).

B. Concurrent Requirement Not applicable.

C. Reason

(1) Description of Existing Condition

(a) CFD sensing elements produced between November 24, 2004 and January 31, 2021 may not properly detect thermal bleed leak events. This specific failure mode is not detectable by Overheat Detection System .

(2) Extent Condition E ncountered

(a) Any CFD sensing elements Part Numbers listed in Section 1.A. may be affected .

(3) Expected Benefits of Modification

(a) Verification that CFD sensing elements will operate per specification .

(4) Safety Intent of Corrective Action

(a) Identify inoperable units by testing for function ality.

(b) Remove inoperable units from the field .

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 5 of 30

(5) Regulatory Action

(a) To be determined by the governing civil aviation authority.

D. Description Shop test CFD sensing elements for proper operation. Failed units will be replaced Free Of Charge (FOC) by Kidde Aerospace and Defense.

E. Compliance Optional - Service Bulletin for convenience or option.

Desirable - Service Bulletin to introduce improvements.

X Recommended - Service Bulletin recommended to be accomplished to prevent significant operational disruptions.

Mandatory - Service Bulletin must be accomplished.

NOTE: Service Bulletin compliance is Highly Recommended per ATA -2200 definition.

F. Approval

(1) The approved design of the CFD sensing element part numbers listed in Section 1.A is in compliance with the requirements of TSO -C11e. This SB allows you to determine if t he suspect parts conform to the approved design

(2) The inspection procedures described in the SB are reviewed and technically accepted by Airbus to apply to the Airbus fleet affected. This SB does not contain any change information that revises the equipment definition covered by Airbus approved modifications.

NOTE: This statement is only valid for PN certified by Airbus, refer to paragraph Effectivity.

G. Manpower The total estimated time to accomplish the work in this service bulletin is 0.5 man hours per unit.

TASK ESTIMATED HOURS Preparation 0.2 Installation 0.0 Testing 0.3 Total 0.5

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 6 of 30

H. Weight and Balance No change.

I. Electrical Load Data No change.

J. Software Accomplishment Summary None.

K. References

(1) Abbreviated Component Maintenance Manual (ACMM) for 1070001-XXXXXX, 36-22-16

(2) ACMM for 1072001 -XXXXXXX, 36-22-17

(3) ACMM for 1094006 -XXXXXX, 1095006-XXX, 04-90014-XXXX, and 04-90016-XXX, 36- 22-05

(4) ACMM for 35518 -48-XXX and 35XXX-X-XXX, 26 -14-12

L. Other Publications Affected None.

M. Interchangeability or Intermixability of Parts N/A

2. MATERIAL INFORMATION A. Material - Price and Availability Tooling Kit part number 173948 available .

NOTE: Tooling Kit 173948 contains items from tables in Section 2.E.

NOTE: Order if test equipment is not av ailable.

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 7 of 30

NOTE: The current charge for Collins to perform this service bulletin is $794.60 United States Dollars (USD) and may be subject to future price adjustments. Pricing is only valid through December 31, 2022.

B. Industry Support Information

(1) The modification materials in this service bulletin may be obtained from:

Not Applicable

(2) The tooling kit in this service bulletin may be obtained from:

Rockwell Collins Rental Exchange 400 Collins Road NE Cedar Rapids, IA 52498 -0001 TELEPHONE: 1.800.713.5467

Email: Collinsdispatchprograms@rockwellcollins.com

Include the following:

Email Subject: CFD NOE Kit Provide FOC PO Power Requirements: 110V or 220V

NOTE: Please review the commercially available t est equipment required in Section

2.E.(2). Order if test equipment is not available .

(3) Warranty For units in and out of warranty, Collins Aerospace will reimburse the cost of this service bulletin or perform this service bulletin at no charge for the materials and labor .

NOTE: Warranty claims will be accepted through December 31, 202 8.

(4) Instructions for Warranty Claims can be found at:

https://portal.rockwellcollins.com/web/support -self-service/warranty

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 8 of 30

(5) Operators can also forward claims for labor reimbursement to the e -mail:

kiddewarranty@collins.com

C. List of Components

(1) Materials Purchased None.

(2) Materials Supplied by Customer

PART NUMBER KEY WORD DESCRIPTION QUANTITY SPECIAL INST R U C T IO N / DISPOSITION Commercially Available* Marking Material Customer Preference As Required (AR) Locally Sourced * Part is at the customers discretion based on local availability D. Subcomponents to be re -identified CFD sensing element part numbers listed in Section 1.A

E. Tooling

(1) Materials Purchased for Testing Procedure

PART NUMBER KEY WORD DESCRIPTION QUANTITY SPECIAL INST R U C T IO N / DISPOSITION Kit 173948 Contains the items below as well as items in the Table f rom Section 2. E.(2) 1146006 -0254 -00 Connecting Cable 100in, Gold, Pin Conn ector 2 N/A 1148006 -0254 -00 Connecting Cable 100in, Gold, Socket Conn ector 2 N/A 476232 Shell and Insert Assy Gold 20 Contact S ocket -Capable receiving 0.06 inch (1.52 mm) diameter contact pin 349457 Contact Pin Gold 20 Gold Plated 0.06 inch (1.52 mm) diameter

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 9 of 30

F. Materials Supplied by Customer for Testing Procedure

PART NUMBER KEY WORD DESCRIPTION QUANTITY RANGE TOLERANCE BK 879B or Equivalent LCR Meter Electronic Test Equipment 1 1 kHz test frequency

0.6-1.0 Vrms test level 0 VDC 0-40 kΩ Z impedance 32-104°F (0 -40 °C) operate temp ±5% Not applicable ±0.02 VDC ±5% Not applicable Steinel HG2320E or Equivalent Heat Gun Heating Gun 1 32-662°F (0-350 °C) (at nozzle) ±10 °F (±5 °C) Steinel 07051 or Equivalent Heat Gun Shield Heat Shield 1 N/A N/A HH501BJK or Fluke 289 or Equivalent Digital Multimeter (DMM) or Digital Temperature Meter (DTM) Measures Temperature 1 Type K input 32- 1100°F (0-594°C)

32-104°F (0-40 °C) operate temp ±4°F (±2.2°C) or 0.75% (whichever is greater)

Not applicable

KMQSS-062U-12 or Equivalent Thermal Couple Measures Temperature 1 Type K input 32 -1100°F (0 -594°C) or greater ±4°F (±2.2°C) or 0.75% (whichever is greater) 4TM11 or Equivalent Stopwatch Stopwatch Time 1 2 minutes (min) 1 second resolution (±5 secs over range)

G. Special Tools None.

3. ACCOMPLISHMENT INSTRUCTIONS

NOTE: Some steps in the accomplishment instructions are identified as Required for Compliance (RC). If this service bulletin is mandated by an airworthiness directive (AD), the steps identified as RC must be done to comply with the AD. Steps not identified with RC are recommended and may be deviated from; done as a part of other actions; or done with accepted methods different from those given in SB if the RC steps can be done and the airplane returned to a serviceable condition.

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 10 of 30

A. General

(1) RC - Test Environment Testing may be performed at a room temperature between 55°F (12.8°C) and 85°F

(29.4°C), and relative humidity not exceeding 90%. Test area must be free from flammable vapors. Work surface used for bench top testing must be made from non -flammable and non-conductive materials.

WARNING: Hot air tool can produce up to 1300°F (795°C) of flameless heat at the nozzle.

Do not direct airstream at clothing, hair, or other body parts. If the hot air is set above 392°F (200°C), ensure the surroundings are free of fuel vapors and other ignition sources.

WARNING: Do not use near flammable liquids or in an explosive environment (fumes, gases, or dust). Remove materials or debris that may become ignited from work area.

WARNING: Always hold tool by plastic en closure. The metal nozzle requires approximately 20 minutes to cool to where it can be touched. Do not touch nozzle or accessory tips until cool.

WARNING: Do not store tool until nozzle has cooled to room temperature. Place tool in a clear area away from combustible materials while cooling.

WARNING: Use shield materials around the heated area to prevent damage or fire.

CAUTION: Do not cut off airflow by p lacing nozzle too close to work piece. Keep intake vents clean and clear of obstructions.

WARNING: Do not leave tool unattended while running or cooling down. Otherwise risk of fire.

CAUTION: Place tool on a level surface when tool is not handheld. Place cord in a position that won’t cause tipping.

Page 12OCROpen in PDF

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN

FIRE PROTECTION- AIRBUS CONTINUOUS FIRE DETECTOR (CFD) -

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION NOTE: Keep a fully charged fire extinguisher nearby.

(2) RC - Sensing Elements Heating Procedure The following figures show how to use the heat gun. A heat protection shield must be used and attached to the end of the heat gun outlet. A heat protection shield (Steinel P/N 07051) is normally supplied in the referenced kit. If not available, the following dimensions can be followed to produce an acceptable heat protection shield. The heat protection shield shall be 1.410.2 inch (~3.56 cm 10.5 cm) in width and rolled in a half circle with a radius of approximately 0.75 inches (1.91 cm) for optimum testing. The end of the half circle shall be 1.25-1.5 inches (~3.18 to 3.81 cm) away from the heat gun outlet as shown in Figure 1 and Figure 2.

SEN SING HEAT GUN OUTLET

ELEMENT

HEAT PROTECTION SHIELD

AIRFLOW -1.00 to 1.25 INCH- RADIUS APPROX (2. 54 TO 3.18 cm)

0.75 INCH

(1.91 cm)

1.25 to 1.5 INCH

(3.18 TO 3.81 cm) Figure 1: Heat Protection Shield Side View

OFF-AXIS

THERMOCOUPLE

LOCATION TC TIP PLACED 0.33 INCH (0.85 cm) FROM CENTERUNE

HEAT GUN OUTLET

1.2 TO 1.6 INCH _ HEAT PROTECTION AIRFLOW

(3.06 TO 4.06 cm)

SENSING

ELEMENT TC TIP ON CENTERLINE OF HEAT FLANGE CENTER

THERMOCOUPLE LOCATION •1.00 to 1.25 INCH

(2.54 TO 3.18 cm) Figure 2: Heat gun with heat protection shield top down view January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 11 of 30

Pages 13–24 of 33