ERRATA CORRIGE

Please find here attached the pages that have to be replaced in the basic Service Bulletin n°189-272

 PAGE 3 “COMPLIANCE” section

Was:

NOTES  The operations performed in accordance with Part IV of this SB covers also the already approved AMPI Maintenance Task

(i.e. MT 64-17, required every 400 FH).

Becomes:

NOTES  The operations performed in accordance with Part IV of this SB covers also the already approved AMPI Maintenance Task

(i.e. MT 64-17, required every 1600 FH).

 PAGE 5 “PUBLICATION” section

Was:

DATA MODULE DESCRIPTION PART DM01 89-A-00-20-00-00A-120A-A Helicopter on ground for a safe maintenance.

I, II, III,

IV, V, VI DM02 89-A-06-41-00-00A-010A-A Access doors and panels - General data I, II DM03 89-A-64-11-05-00A-520A-A Lightning conductor jumper - Remove procedure II Becomes:

DATA MODULE DESCRIPTION PART DM01 89-A-00-20-00-00A-120A-A Helicopter on ground for a safe maintenance.

I, II, III,

IV, V, VI DM02 89-A-06-41-00-00A-010A-A Access doors and panels - General data I, II DM03 DELETED - -

 PAGE 13 “ACCOMPLISHMENT INSTRUCTIONS”

Was:

Step 6.3.1 - In accordance with applicable steps of AMP DM 89-A-64-31-01-00A- 720A-A, temporarily detach the upper attachment of all the pitch links from the TR.

Step 6.3.4 - In accordance with AMP DM 89-A-64-11-05-00A-520A-A, disconnect the TR lightning conductor jumper.

Becomes:

Step 6.3.1 - In accordance with applicable steps of AMP DM 89-A-64-31-01-00A- 520A-A, temporarily detach the upper attachment of all the pitch links from the TR.

Step 6.3.4 - DELETED.

 PAGE 18 “ACCOMPLISHMENT INSTRUCTIONS”

Was:

Step 6 - In accordance with AMP DM 89-A-64-11-05-00A-520A-A, disconnect the TR lightning conductor jumper.

Becomes:

Step 6 - DELETED.

N° 189-272 DA TE: August 4, 2020 REV. : / - July 10, 2020 Pa ge 1 of 27 TITLE ATA 64 - TR FLIGHT CONTROL PERIODICAL INSPECTION FOR IMPROVED DUPLEX B EARING

REVISION LOG First issue.

Leonardo S.p.A.

Via Giovanni Agusta, 520 21017 Cascina Costa di Samarate (VA) Italy Tel.: +39 0331 229111 - Fax: +39 0331 229605/222595 An appropriate entry should be made in the aircraft log book upon accomplishment.

If ownership of aircraft has changed, please, forward to new owner.

EMERGENCY ALERT

SERVICE BULLETIN

S.B. N°189-272 EMERGENCY ALERT DATE: August 4, 2020 Page 2 of 27 REVISION: /

1. PLANNING INFORMATION A. EFFECTIVITY Part I: All AW 189 helicopters equipped with Tail Rotor Duplex Bearing P/N MM6430V00151 and TRA P/N 6F6730V00331.

Part II: All AW 189 helicopters equipped with Tail Rotor Duplex Bearing P/N MM6430V00151.

Part III: All AW 189 helicopters equipped with Tail Rotor Duplex Bearing P/N MM6430V00151.

Part IV: All AW 189 helicopters equipped with Tail Rotor Duplex Bearing P/N MM6430V00151.

B. COMPLIANCE

GENERAL NOTE A non-cumulative tolerance of 10% may be applied to the compliance times specified in this SB to allow synchronization of the required inspections with other required maintenance tasks for which a non-cumulative tolerance is already granted in the applicable Maintenance Manual.

Part I:

Within 10 FH from any installation of TR Duplex Bearing P/N MM6430V00151. Then repeat the inspection every 10 FH.

NOTES  Every time it is required to perform Part II, accomplishment of Part I on the same maintenance downtime must be performed as a prerequisite.

 If Part III is required in the same maintenance downtime of Part II, it shall be performed lastly.

Part II:

Within 50 FH from any installation of TR Duplex Bearing P/N MM6430V00151. Then repeat the inspection every 50 FH.

Part III:

Upon any installation of TR Duplex Bearing P/N MM6430V00151. Then repeat the inspection every 100 FH.

S.B. N°189-272 EMERGENCY ALERT DATE: August 4, 2020 REVISION: / Page 3 of 27 NOTES  Perform in sequence Part I and Part II as a prerequisite.

 If Part III is required in the same maintenance downtime of Part IV, it shall be performed after Part IV.

 The operations performed in accordance with Part IV of this SB covers also the already approved AMPI Maintenance Task (i.e. MT 64- 17, required every 1600 FH).

Part IV:

Within 100 FH from any installation of TR Duplex Bearing P/N MM6430V00151. Then repeat the inspection every 100 FH.

C. CONCURRENT REQUIREMENTS N.A.

D. REASON This Service Bulletin is issued in order to require the periodical inspection of the slippage marking of the back-end castellated nut of the TR servo-actuator, the introduction of a new Thermal strip and the periodical detailed inspection of the new improved TR duplex bearing.

E. DESCRIPTION Following the introduction on in-service fleet of the new improved TR Duplex Bearing P/N MM6430V00151, this Service Bulletin provides the instructions for the new inspection regime, partially requiring some of the checks already requested by SB 189- 237 on previous TR Duplex Bearing P/N 4F6430V00551.

In details, Part I of this Service Bulletin provides the periodical detailed inspection of the slippage marking of the castellated nut installed on the back end of the TRA P/N 6F6730V00331, retaining the requirements of Part I of SB 189-237.

Part II partially retains the requirement of the Parts II, IV and V of the SB 189-237, requiring the detailed inspection of TR duplex bearing, in addition to the verification of particle presence in the grease and the recursive check of the Thermal strip.

Part III provides the instructions to install a new dedicated Thermal strip in the area of the TR duplex bearing.

S.B. N°189-272 EMERGENCY ALERT DATE: August 4, 2020 Page 4 of 27 REVISION: / Part IV partially retains the requirement of the Parts II and VI of the SB 189-237, requiring a check for axial play and a roughness check of the duplex bearing to be performed after removal of the spider assembly.

Incorrect installation of the TR servo-actuator back-end nut or seizure of the TR Duplex bearing may lead to loss of Tail Rotor control which, depending on the flight condition, could lead to loss of control of the aircraft.

Feedback on the compliance to this Service Bulletin is required.

F. APPROVAL The technical content of this Service Bulletin is approved under the authority of DOA nr.

EASA.21.J.005. For helicopters registered under other Aviation Authorities, before applying the Service Bulletin, applicable Aviation Authority approval must be checked within Leonardo Helicopters customer portal.

E.A.S.A. states mandatory compliance with inspections, modifications or technical directives and related time of compliance by means of relevant Airworthiness Directives.

If an aircraft listed in the effectivity embodies a modification or repair not LHD certified and affecting the content of this Service Bulletin, it is responsibility of the Owner/Operator to obtain a formal approval by Aviation Authority having jurisdiction on the aircraft, for any adaptation necessary before incorporation of the present Service Bulletin.

G. MANPOWER To comply with this Service Bulletin the following MMH are deemed necessary:

Part I: approximately half (0.5);

Part II: approximately two (2);

Part III: approximately one (1);

Part IV: approximately three (3);

MMH are based on hands-on time and can change with personnel and facilities available.

H. WEIGHT AND BALANCE N.A.

S.B. N°189-272 EMERGENCY ALERT DATE: August 4, 2020 REVISION: / Page 5 of 27 I. REFERENCES

1) PUBLICATIONS

DATA MODULE DESCRIPTION PART DM01 89-A-00-20-00-00A-120A-A Helicopter on ground for a safe maintenance.

I, II, III,

IV, V, VI DM02 89-A-06-41-00-00A-010A-A Access doors and panels - General data I, II DM03 DELETED - - DM04 89-A-64-31-01-00A-520A-A Pitch link - Remove procedure II DM05 89-A-64-31-01-00A-720A-A Pitch link - Install procedure II DM06 89-A-64-31-03-00A-520A-A Spider plug - Remove procedure II, III, IV, V, VI DM07 89-A-64-31-03-00A-720A-A Spider plug - Install procedure II, III, IV, V, VI DM08 89-A-64-31-02-00A-520A-A Scissors group – Remove procedure II DM09 89-A-64-31-07-00A-520A-A Boot - Remove procedure II DM10 89-A-64-31-04-00A-520A-A Spider and slider assembly - Remove procedure II, VI DM11 89-A-64-31-04-00A-720A-A Spider and slider assembly - Install procedure II, VI DM12 89-A-64-31-05-00A-520A-B Duplex bearing - Remove procedure

II, IV, V, VI DM13 89-A-64-31-05-00A-720A-B Duplex bearing - Install procedure II, IV, V, VI

2) ACRONYMS AMDI Aircraft Material Data Information AMP Aircraft Maintenance Publication DM Data Module DOA Design Organization Approval EASA European Aviation Safety Agency ITEP Illustrated Tool and Equipment Publication LHD Leonardo Spa Helicopters MMH Maintenance Man Hours FH Flight Hours SB Service Bulletin TR Tail Rotor

S.B. N°189-272 EMERGENCY ALERT DATE: August 4, 2020 Page 6 of 27 REVISION: / TRA Tail Rotor Actuator

3) ANNEX N.A.

J. PUBLICATIONS AFFECTED N.A.

K. SOFTWARE ACCOMPLISHMENT SUMMARY N.A.

S.B. N°189-272 EMERGENCY ALERT DATE: August 4, 2020 REVISION: / Page 7 of 27

2. MATERIAL INFORMATION A. REQUIRED MATERIALS

1) PARTS # P/N ALTERNATIVE P/N DESCRIPTION Q.TY LVL NOTE LOG P/N 1 M06SHA094D01R1 Thermal Strip 1 . (1)(2) - 2 LAMHALPATCH01R1 Protective layer 1 . (1) -

Refer also to AW189 IPD for the spares materials required to comply with the AMP DMs referenced in the accomplishment instructions.

2) CONSUMABLES The following consumable materials, or equivalent, are necessary to accomplish this Service Bulletin:

# Spec./LHD code number DESCRIPTION Q.TY NOTE PART 3 TT-N-95-B / Code No. 531055030 Aliphatic Naphtha (C059) AR (3) II,III

Refer to AW189 AMDI for the consumables required to comply with the AMP DMs referenced in the accomplishment instructions.

3) LOGISTIC MATRIX N.A.

NOTE

(1) This item, strictly required for Part III embodiment, may be required on condition also within the embodiment of other Parts of this SB.

(2) Identification on label M06SHAL094D01R1 is printed on the thermal strip.

(3) Item to be furnished as local supply.

B. SPECIAL TOOLS Refer to AW189 ITEP for the special tools required to comply with the AMP DMs referenced in the accomplishment instructions.

C. INDUSTRY SUPPORT INFORMATION Owners/Operators who comply with the instructions of this Service Bulletin no later than the applicable date in the “Compliance” section will be eligible to receive REQUIRED MATERIALS on free of charge basis, except for Consumable Materials and Special Tools.

S.B. N°189-272 EMERGENCY ALERT DATE: August 4, 2020 Page 8 of 27 REVISION: / NOTE: Customers who fail to comply with the instructions in this Service Bulletin before the compliance date are not eligible for the aforementioned special policy.

Please Issue relevant MMIR form to your Warranty Administration Dpt.

NOTE: WRM will include RETURN MATERIAL AUTHORIZATION (RMA) number; the unit disembarked from the aircraft has to be returned to LHD within thirty (30) calendar days after the shipment of the replacement part. In case of missing return within thirty

(30) calendar days, Customer will be invoiced for the price of the replacement part.

S.B. N°189-272 EMERGENCY ALERT DATE: August 4, 2020 REVISION: / Page 9 of 27

3. ACCOMPLISHMENT INSTRUCTIONS

GENERAL NOTES

a) Place an identification tag on all components that are re-usable, including the attaching hardware that has been removed to gain access to the modification area and adequately protect them until their later reuse.

PART I

1. In accordance with AMP DM 89-A-00-20-00-00A-120A-A, prepare the helicopter on ground for a safe maintenance. Disconnect the battery, all electrical power sources and/or the external power supply.

NOTE Removal of access panels 495A and 496A can be avoided if visual access to the inspection area is available by other means. A suitable borescope can be used for this purpose.

2. In accordance with AMP DM 89-A-06-41-00-00A-010A- A remove the access panels 495A and 496A.

3. Take a picture of the back-end area of the TRA clearly showing the slippage mark, and keep a record in a local archive to be made available if required.

4. With reference to Figure 1, check the slippage mark on the castellated nut for absence of evidence of rotation between the parts. Record the result on Table I on Figure 5.

5. If any evidence of rotation is found, contact the Product Support Engineering (engineering.support.lhd@leonardocompany.com) to receive further instructions before performing the following checks:

5.1 Send the picture taken at step 3 to Product Support Engineering (engineering.support.lhd@leonardocompany.com).

5.2 If the helicopter is already compliant with the SB 189-227, perform HUMS data download from AMMC to DTD. Upload the HUMS data to Heliwise.

5.3 Perform Thermal strip and TR Duplex bearing detailed inspection as per Part II of this SB;

5.4 In case replacement of Duplex Bearing is confirmed as necessary, perform step

6.3 of Part II of this SB.

6. If no evidence of rotation is found in step 4, return the helicopter to a ready to flight condition and record for compliance with Part I of this Service Bulletin on the helicopter

S.B. N°189-272 EMERGENCY ALERT DATE: August 4, 2020 Page 10 of 27 REVISION: / logbook.

7. Send the attached compliance form and the compiled Table I to the following mail box:

engineering.support.lhd@leonardocompany.com As an alternative, gain access to My Communications section on Leonardo WebPortal and compile the “Service Bulletin Application Communication”.