Some pages are OCR from a scan. OCR can misread letters and numbers. © Pratt & Whitney. Filed by the FAA in regulations.gov docket FAA-2023-2523; AD 2024-06-04 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '842da320ab2ae4b7b911d75ae467f2b7c95d690121ef8c7b51d5788986a01d20' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '842da320ab2ae4b7b911d75ae467f2b7c95d690121ef8c7b51d5788986a01d20' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991
ENGINE - HUB, HIGH PRESSURE TURBINE (HPT), 1ST AND 2ND STAGE - DO A REPETITIVE ANGLED ULTRASONIC SCAN INSPECTION OF THE HPT 1ST AND 2ND STAGE HUBS FOR A MANUFACTURING
ANOMALY DMC: PW1000G-A-72-00-0205-00A-930A-D | Issue No: 001 | Issue Date: 2023-11-30
ALERT SERVICE BULLETIN Revision History Original Issue (001) November 30, 2023 Reason for the Revision This is the Original Issue of this Service Bulletin.
MODEL APPLICATION PW1519G, PW1521G, PW1521GA, PW1521G-3, PW1524G, PW1524G-3, PW1525G, PW1525G-3
BULLETIN ISSUE SEQUENCE PW1500G Series 72-00-0205
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991
ENGINE - HUB, HIGH PRESSURE TURBINE (HPT), 1ST AND 2ND STAGE - DO A REPETITIVE ANGLED ULTRASONIC SCAN INSPECTION OF THE HPT 1ST AND 2ND STAGE HUBS FOR A MANUFACTURING
ANOMALY
RTX/P&W PROPRIETARY INFORMATION This document contains proprietary information of RTX Corporation ("RTX") and/or of one or more of RTX's worldwide divisions, subsidiaries, and affiliates including Pratt & Whitney Canada, Pratt & Whitney, and Collins Aerospace and/or of a supplier and/or partner to any of the foregoing RTX entities. The proprietary information set forth in this document is provided in confidence and solely for the purposes of supporting engine certification and providing applicable information regarding the proper use, maintenance, inspection, repair, and servicing and parts application of Pratt & Whitney engine products and services ("Purpose"). By accepting this document the recipient agrees to limit copying the document, or any information in it, solely for distribution within the recipient's company or to a third party to carry out the stated Purpose for the document and any information in it. You cannot possess, use, copy, or disclose this document or any information in it for any purpose other than that stated above, without RTX's express written permission. Violation of these restrictions may result in criminal and/or civil liability.
Neither this document nor any information in it may be disclosed to others, or used for any other purpose, including, without limitation, to design, create, develop, reproduce, manufacture or derive any design, part, product, material, process, modification, configuration change or repair, or obtain FAA, TCCA or other government approval to do so.
If a Government agency or department intends to disclose any information, written notice should be given to: (1) Intellectual Property Counsel, Pratt & Whitney, 400 Main Street, East Hartford, CT 06118, U.S.A.; (2) VP and Counsel, Commercial Engines, Pratt & Whitney, 400 Main Street, East Hartford, CT 06118, U.S.A.
WARNING: This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-
774. Diversion contrary to U.S. law is prohibited. The export, re-export, transfer or re-transform of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by Pratt & Whitney, is prohibited without prior written approval from, as applicable, RTX, P&WC, Pratt & Whitney and/or Collins Aerospace, and authorization under applicable export laws.
EAR Export Classification: ECCN 9E991 Compliance Category 6
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 Summary The purpose of this Alert Service Bulletin is to do a repetitive angled ultrasonic scan inspection of the High Pressure Turbine (HPT) 1st and 2nd stage hubs for a manufacturing anomaly. The source of the anomaly is thought to occur during part manufacture.
Planning Information Applicability Engine Models Applicable PW1519G, PW1521G, PW1521GA, PW1521G-3, PW1524G, PW1524G-3, PW1525G, PW1525G-3 Engine Serial Nos. - All engines that incorporated Reference 4, Service Bulletin No.
PW1000G-A-72-00-0164-00A-930A-D with the part numbers identified in Table 1.
Table 1. HPT 1st And 2nd Stage Hub Part Numbers HPT 1st Stage Hub Part Number HPT 2nd Stage Hub Part Number 30G8501 30G7202 Concurrent Requirements There are no concurrent requirements.
Reason Problem: HPT 1st and 2nd stage hubs shipped before the revised production inspection procedures can contain anomalies that affect the part material.
Cause: It is possible that anomalies were introduced during powdered metal manufacturing which were not identified by the inspection methods available at that time.
Solution: Do a repetitive angled ultrasonic scan inspection of the HPT 1st and 2nd stage hubs that can identify material anomalies.
Description Do a repetitive angled ultrasonic scan inspection of the HPT 1st and 2nd stage hubs.
Compliance Category 6 Do a repetitive angled ultrasonic scan inspection of the HPT 1st and 2nd stage hubs when the HPT 1st and 2nd stage rotor assemblies are separated. See Figure 1 for the definition of HPT 1st and 2nd stage rotor assembly separation.
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 NOTE If the part accumulated 100 cycles or less in service since the last inspection, it is not necessary to do an inspection again.
NOTE It is possible that an angled ultrasonic scan inspection was completed at OEM or by Reference 5, Alert Service Bulletin No. PW1000G-A-72-00-0196-00A-930A-D, however, compliance with this Alert Service Bulletin is still necessary.
NOTE 'Engine Shop Visit' is the induction of an engine into the shop for maintenance involving the separation of major core engine flanges inclusive of D flange and aft. The separation of engine flanges solely for the purpose of transportation without subsequent engine maintenance does not constitute a shop visit. See Figure 2.
Approval Data The part number changes and/or part changes specified in the Material Information section and Accomplishment Instructions of this Service Bulletin agree with the applicable Federal Aviation Regulations and are FAA-Approved for the engine model(s) given.
Manpower The estimate of man-hours of labor directly necessary to do the intent of this Service Bulletin are as follows:
Necessary to Gain Access to the Parts From HPT 1st and 2nd Stage Rotor Assembly ... 16.0 hours.
Necessary to Clean the Parts ... 16.0 - 20.0 hours.
Necessary to Do a Visual Inspection of the Parts ... 4.0 hours.
Necessary to Do a Fluorescent Penetrant Inspection of the Parts ... 4.0 hours.
If Necessary to Make a Mark on the Parts ... 0.5 hour.
Total Necessary Man-hours ... 40.5 - 44.5 hours.
Weight and Balance No Change.
Electrical Load Data Not Applicable.
1.
A.
2.
3.
4.
5.
6.
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 Software Accomplishment Summary Not Applicable.
References Turbojet Engine Standard Practices Manual, Part No. 585005.
PW1500G Series Engine Illustrated Parts Data (EIPD), PN 5305819.
PW1500G Series SP-72-51 Special Procedures - High Pressure Turbine (HPT) Module PN 5317960.
Service Bulletin No. PW1000G-A-72-00-0164-00A-930A-D; Engine - Rotor And Nozzle Assembly, High Pressure Turbine (HPT) - Introduce An HPT Rotor Assembly And HPT Nozzle Assembly Configuration With Increased Durability.
Alert Service Bulletin No. PW1000G-A-72-00-0196-00A-930A-D; Engine - Hub, High Pressure Turbine (HPT), 1st And 2nd Stage - Inspection Of The HPT 1st And 2nd Stage Hubs For Manufacturing Anomaly.
Non-Destructive Inspection Procedure (NDIP) NDIP-1254, dated July 28, 2022, or later revision.
Non-Destructive Inspection Procedure (NDIP) NDIP-1257, dated September 7, 2022, or later revision.
Publications Changed -PW1500G Series Engine Illustrated Parts Data (EIPD), PN 5305819 72-51-30, Figure 01 72-51-40, Figure 01 Interchangeability Not Applicable.
Information in the Appendix Alternate Accomplishment Instructions (No) Progression Charts (No) Added Data (Yes) Revision to Table of Limits (No) Inspection Procedures (No) Material - Cost and Availability
1.
2.
3.
4.
5.
6.
7.
1.
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 Part prices were not available at the time of Service Bulletin publication. Contact Pratt & Whitney Spares Management & Logistics for firm quotations.
There is no kit provided to do this Service Bulletin.
Part availability information is provided in material data Instructions - Disposition.
Industry Support Program Not Applicable.
Modification and Spares Information Parts Modification Conditions
(4) Do an inspection as specified in the Accomplishment Instructions.
Spare Parts Availability (X) See Reference 2, Illustrated Parts Data for applicable replacement parts.
Vendor Services or Special Components/Materials Operators seeking an approved repair station to modify parts affected by this Alert Service Bulletin please reference the repair Service Value Catalog (SVC) published by the PW Repair Sourcing team. For more information please contact the Pratt & Whitney Repair Sourcing team by email:
pw1500sourcing@prattwhitney.com. For the HPT 1st stage hub, do the inspection as specified by Reference 6, NDIP-1254. For the HPT 2nd stage hub, do the inspection as specified by Reference 7, NDIP-1257.
Material Information Support Equipment List:
No more Support Equipment is necessary.
Material Information Table:
NOTE It is possible to use the Chapter/Section and Figure/Item reference number shown below the old part number to find the part in the Illustrated Parts Data.
Because there are many different configurations used, it is frequently necessary to show more than one group of parts. When this occurs, parts that are interchangeable are shown line-by-line only, unless this is shown differently.
CAUTION: THE FOLLOWING MATERIAL DATA TABLE(S) ARE ORGANIZED BY ILLUSTRATED PARTS DATA. ALL PARTS IN THE TABLE(S) MAY OR MAY NOT BE APPLICABLE TO ALL THE ENGINE MODELS SHOWN IN THE TABLE HEADING. YOU MUST REFER TO THE
APPROPRIATE ILLUSTRATED PARTS DATA FOR ENGINE MODEL APPLICABILITY USING THE OLD PART NUMBER (PN) AND CATALOG SEQUENCE NUMBER. FAILURE TO INSTALL THE
PART(S) IN THE CORRECT ENGINE MODEL MAY RESULT IN A CONFIGURATION THAT IS NOT FAA APPROVED.
For PW1519G, PW1521G, PW1521GA, PW1521G-3, PW1524G, PW1524G-3, PW1525G, PW1525G-3 Engines:
2.
3.
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 New Part Number Part Name Quantity Old Part Number (CSN) Instructions - Dispositions HUB - HPT, 1ST STAGE 1 30G8501 (72-51-30-01A- 410B)
(4)(X) HUB - HPT, 2ND STAGE 1 30G7202 (72-51-40-01A- 410B)
(4)(X) Accomplishment Instructions Remove the HPT 1st Stage Hub, PN 30G8501, as specified in Reference 3, Special Procedures, PWSPROC-A-72-51-30-00A-530A-B and PWSPROC-A-72-51-30-01A-530A-B.
See Figure 3 (Sheet 1 of 2).
Remove the HPT 2nd Stage Hub, PN 30G7202, as specified in Reference 3, Special Procedures, PWSPROC-A-72-51-40-01A-530A-B and PWSPROC-A-72-51-40-00B-530A-B.
See Figure 4 (Sheet 1 of 2).
Clean the HPT 1st and 2nd stage hubs to prepare for Fluorescent Penetrant Inspection (FPI), as specified in Reference 3, Special Procedures, PWSPROC-A-72-51-0000-00C-250A-C. See Figure 3 (Sheet 1 of 2) and Figure 4 (Sheet 1 of 2).
Do an FPI of the HPT 1st and 2nd stage hubs, as specified in Reference 3, Special Procedures, PWSPROC-A-72-51-3141-00A-351A-C and PWSPROC-A-72-51-4141-00A-351A-C.
Do a visual inspection of the HPT 1st and 2nd stage hubs for damage, as specified in Reference 3, Special Procedures, PWSPROC-A-72-51-3141-00A-310A-C and PWSPROC-A-72-51-4141-00A-310A-C.
Send the HPT 1st and 2nd stage hubs to an approved source. Contact the P&W Repair Sourcing Team identified in the Vendor Services or Special Components/Materials section above for an authorized vendor and shipping information.
The vendor will examine and return the part after they do the angled ultrasonic scan inspections that follow.
For the HPT 1st Stage Hub, PN 30G8501, Reference 6, NDIP-1254, dated July 28, 2022, or later approved revision. See Figure 3 (Sheet 1 of 2).
For the HPT 2nd Stage Hub, PN 30G7202, Reference 7, NDIP-1257, dated September 7, 2022, or later approved revision. See Figure 4 (Sheet 1 of 2).
If the HPT 1st or 2nd stage hubs do not pass their applicable angled ultrasonic scan inspection, remove the part from service and return the part to Pratt & Whitney Commercial Serviceable Assets (CSA) unless otherwise directed by Customer Technical Services (CTS).
See Figure 3 (Sheet 1 of 2) and Figure 4 (Sheet 1 of 2).
If the HPT 1st stage hub passes the angled ultrasonic scan inspection, do a check of the record of serial number and certificate of conformance, and make a mark as follows. See Figure 3.
Find the HPT 1st stage hub part number "30G8501" mark.
Use a mechanical vibration peen or deep dot peen method and make a "NDIP-1254 CSN ####" mark in the outer diameter in the location of dimension BF, as specified in Reference 1, SPM, Chapter/Section 70-11-00. "####" is the number of cycles since new on the part at the time of inspection.
1.
2.
3.
4.
5.
6.
7.
A.
B.
8.
9.
A.
B.
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 NOTE The purpose of the mark is to identify that the referenced NDIP was completed and to identify the cycles since new of the part at the time of the angled ultrasonic scan inspection. An example where the NDIP was completed at 1000 cycles since new would receive: NDIP-1254 CSN 1000.
If the HPT 2nd stage hub passes the angled ultrasonic scan inspection, do a check of the record of serial number and certificate of conformance, and make a mark as follows. See Figure 4.
Find the HPT 2nd stage hub part number "30G7202" mark.
Use a mechanical vibration peen or deep dot peen method and make a "NDIP-1257 CSN ####" mark in the location of the outer diameter of the shaft forward of the HPT snap, as specified in Reference 1, SPM, Chapter/Section 70-11-00. "####" is the number of cycles since new on the part at the time of inspection.
NOTE The purpose of the mark is to identify that the referenced NDIP was completed and to identify the cycles since new of the part at the time of the angled ultrasonic scan inspection. An example where the NDIP was completed at 1000 cycles since new would receive: NDIP-1257 CSN 1000.
Install the HPT 1st Stage Hub, PN 30G8501, with the new mark as specified in Reference 3, Special Procedures, PWSPROC-A-72-51-30-00A-710A-B. See Figure 3 (Sheet 1 of 2).
Install the HPT 2nd Stage Hub, PN 30G7202, with the new mark as specified in Reference 3, Special Procedures, PWSPROC-A-72-51-40-00A-710A-B. See Figure 4 (Sheet 1 of 2).
10.
A.
B.
11.
12.
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 Figure 1: HPT 1ST AND 2ND STAGE ROTOR ASSEMBLY SEPARATION
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 Figure 2: LOCATION OF THE ENGINE FLANGES
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 Figure 3: LOCATION OF THE HPT 1ST STAGE HUB (Sheet 1 of 2) 30G8501 HPT 1ST STAGE HUB
EXAMINE AS SPECIFIED
IN THE ACCOMPLISHMENT
INSTRUCTIONS
IN THE ACCOMPLISHMENT IDENTIFY AS SPECIFIED INSTRUCTIONS
1.250 MAX par ICN-PW1000G-A-72000205-P-77445-41738-A-001-01
Pratt & Whitney Proprietary Information © 2023.Subject to export control. EAR Export Classification: ECCN 9E991 Figure 3: LOCATION OF THE HPT 1ST STAGE HUB (Sheet 2 of 2)