On this page
ADs that cite it · 1
Newest first, with the revision each names, as OpenAirDocs read it from the AD’s text: check it against the AD.
Also cited in 1 proposed AD.
Text · 21Partly OCR
Some pages are OCR from a scan. OCR can misread letters and numbers. © Pratt & Whitney. Filed by the FAA in regulations.gov docket FAA-2016-8836; AD 2017-05-05 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '3b0a40c8dc878079de6903681b803954c68e6521d0009db476b6cf91dc33723f' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '3b0a40c8dc878079de6903681b803954c68e6521d0009db476b6cf91dc33723f' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SER VICE
BULLETIN ENGINE — HUB, FRONT ,
TURBINE,
ASSEMBL Y OF —
INSPECTION OF THE HUB FOR A MISMA TCH (STEP) ON THE AFT SIDE M O D E L A P P L I C A T I O N PW4074, PW4074D, PW4077, PW4077D, PW4084D, PW4090, PW4090-3 B U L L E T I N I S S U E S E Q U E N C E PW4G-1 12 Series 72-342 A T A N U M B E R 72-52-00 U T C / P & W P R O P R I E T A R Y I N F O R M A T I O N This document is the property of United T echnologies Corporation — Pratt & Whitney (UTC/P&W).
Y ou may not possess, use, copy or disclose this document or any information in it, for any purpose, including without limitation to design, manufacture, or repair parts, or obtain F AA or other government approval to do so, without UTC/P&W’ s express written permission.
Neither receipt nor possession of this document alone, from any source, constitutes such permission.
Possession, use, copying or disclosure by anyone without UTC/P&W’ s express written permission is not authorized and may result in criminal and/or civil liability .
Not subject to the EAR per 15 C.F .R.
Chapter 1, Part
734.3(b)(3).
C o m p l i a n c e C a t e g o r y 5, 6 P & W D i s t r i b u t i o n C o d e 2641 September 23/16 PW4G-1 12-72-342 Page 1 of 21 Published in United States of America
S u m m a r y The function of this Service Bulletin is to provide an inspection procedure to measure the surface condition of the aft side web/rim fillet on the front turbine hub assembly .
There has been one incident of hub fracture which initiated in the aft side at the web/rim fillet, and examination of the fracture site revealed a mismatch feature (step).
This Service Bulletin supersedes Reference 6, Special Instruction 250F-16.
P l a n n i n g I n f o r m a t i o n E f f e c t i v i t y D a t a E n g i n e M o d e l s A p p l i c a b l e PW4074, PW4077 Engine Serial No.
— All engines PW4074D, PW4077D, PW4084D, PW4090, PW4090-3 Engine Serial No.
— All engines N O T E :
The engine serial number ef fectivity data and its related engine model identification contained in this Service Bulletin are taken from the records of part(s) incorporation during initial manufacture.
After initial engine manufacture, but before final delivery , P&W may change part(s) in the engine or change the model identification of the engine.
Such action is recorded on F AA337 forms.
T o find Service Bulletin PW4G-1 12-72-342 models that are applicable, the owner/operator of the engine must compare the Service Bulletin List supplied with the engine as sent from P&W and the List of Changes incorporated at the Airframer from F AA337 forms to the Service Bulletin PW4G-1 12-72-342 Ef fectivity section.
The PW4090 Engine ef fectivity is also applicable to all the PW4090 de-rate models (PW4074D, PW4077D, and PW4084D) unless otherwise specified.
C o n c u r r e n t R e q u i r e m e n t s There are no concurrent requirements.
R e a s o n
1.
Problem:
There has been one incident of hub fracture which initiated in the aft side at the web/rim fillet, and examination of the fracture site revealed a mismatch feature (step).
2.
Cause:
An investigation revealed nonconforming geometry (mismatch) of the radii transition feature.
It has also been determined that this nonconforming mismatch can occur during front turbine hub manufacture.
A nonconforming mismatch results in increased stress at the web/rim fillet location.
3.
Solution:
This Service Bulletin requires one-time dimensional inspection of all detail front turbine hub assemblies for a nonconforming mismatch of the web/rim fillet transition feature when the HPT module, 1st rotor assembly , hub assembly , or detail hub is removed from the engine.
This includes 1st stage rotor assemblies, hub assemblies and detail hubs currently removed or currently installed in removed HPT modules.
All front hubs found with mismatch beyond serviceable limits must be removed from service.
September 23/16 PW4G-1 12-72-342 Page 2
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not Subject to the EAR per 15 C.F .R.
Chapter 1, Part
734.3(b)(3).
D e s c r i p t i o n Do an inspection of the surface condition of the aft side web/rim fillet on the front turbine hub assembly .
C o m p l i a n c e For Part A (PW4074D, PW4077D, PW4084D, PW4090 and PW4090-3 models) Category 5 Do when the engine is disassembled suf ficiently to give access to the changed subassembly
(i.e., module, accessories, components, build groups) and to all changed spare subassemblies.
For Part B (PW4074 and PW4077 models) Category 6 Do when the subassembly
(i.e.
modules, accessories, components, build groups) is disassembled suf ficiently to give access to the changed part and to all changed spare parts.
A p p r o v a l D a t a The times between inspections specified in Compliance and the inspection procedures specified in the Accomplishment Instructions agree with the applicable Federal A viation Regulations and are F AA-Approved for the engine model(s) given.
M a n p o w e r The estimate of man-hours of labor directly necessary to do the intent of this Service Bulletin are as follows:
1.
T otal Necessary Man-hours .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1.5 W e i g h t D a t a No Change.
E l e c t r i c a l L o a d D a t a Not Applicable.
S o f t w a r e A c c o m p l i s h m e n t S u m m a r y Not Applicable.
R e f e r e n c e s
1.
T urbojet Engine Standard Practices Manual, Part No.
585005.
2.
PW4074, PW4077 T urbofan Engines, Illustrated Parts Catalog, Part No.
51A346.
3.
PW4074D, PW4077D, PW4084D, PW4090, PW4090-3, PW4090D, PW4098 T urbofan Engines, Illustrated Parts Catalog, Part No.
51A742.
4.
PW4074D, PW4077D, PW4084D, PW4090, PW4090-3, PW4090D, PW4098 T urbofan Engines, Engine Manual, Part No.
51A751.
5.
PW4000 Series 1 12 Inch PW4074, PW4077, PW4077D, PW4084D, PW4090, PW4098 T urbofan Engines, Engine Cleaning, Inspection And Repair (CIR) Manual, Part No.
51A750.
6.
Special Instruction (SI) 250F-16.
September 23/16 PW4G-1 12-72-342 Page 3
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not subject to the EAR per 15 C.F .R Chapter 1, Part
734.3(b)(3).
P u b l i c a t i o n s C h a n g e d PW4074, PW4077 T urbofan Engines, Illustrated Parts Catalog, Part No.
51A346.
72-52-00, Figure 1 PW4074D, PW4077D, PW4084D, PW4090, PW4090-3, PW4090D, PW4098 T urbofan Engines, Illustrated Parts Catalog, Part No.
51A742.
72-52-00, Figure 1 I n t e r c h a n g e a b i l i t y Not Applicable.
I n f o r m a t i o n i n t h e A p p e n d i x Alternate Accomplishment Instructions (No) Progression Charts (No) Added Data (Y es) Revision to T able of Limits (No) Inspection Procedures (No) September 23/16 PW4G-1 12-72-342 Page 4
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not Subject to the EAR per 15 C.F .R.
Chapter 1, Part
734.3(b)(3).
M a t e r i a l I n f o r m a t i o n M a t e r i a l — C o s t a n d A v a i l a b i l i t y
1.
There is no new material cost to do this Service Bulletin when the part modification procedure is used.
2.
There is no kit provided to do this Service Bulletin.
I n d u s t r y S u p p o r t P r o g r a m Not Applicable.
T h e m a t e r i a l d a t a t h a t f o l l o w s i s f o r e a c h e n g i n e .
N O T E :
It is possible to use the Chapter/Section and Figure/Item reference number shown below the old part number to find the part in the Illustrated Parts Catalog.
Because there are many dif ferent configurations used, it is frequently necessary to show more than one group of parts.
When this occurs, parts that are interchangeable are shown line-by-line only , unless this is shown dif ferently .
C A U T I O N :
THE
FOLLOWING MA TERIAL DA T A T
ABLE(S) ARE
ORGANIZED BY
ILLUSTRA TED P AR TS CA T ALOG.
ALL P AR TS IN THE T
ABLE(S) MA Y OR MA Y NOT BE
APPLICABLE T O ALL THE ENGINE MODELS SHOWN IN THE T ABLE HEADING.
YOU MUST REFER T O THE
APPROPRIA TE
ILLUSTRA TED P AR TS CA T ALOG FOR ENGINE MODEL
APPLICABILITY USING THE OLD P AR T NUMBER (PN) AND CA T ALOG
SEQUENCE NUMBER.
F AILURE T O INST ALL THE P AR T(S) IN THE
CORRECT ENGINE MODEL MA Y RESUL T IN A
CONFIGURA TION THA T IS NOT F AA APPROVED.
T h e m a t e r i a l d a t a t h a t f o l l o w s i s f o r e a c h e n g i n e .
F o r P W 4 0 7 4 , P W 4 0 7 7 E n g i n e s :
New PN Qty Estimate of Unit Price ($) Keyword Old PN Instructions — Disposition 1 HUB — ASSY OF , TURB, FR 50L761 (72-52-00-1-20)
(4)(X) 1 .HUB 52L201
(4)(W) OR 1 HUB — ASSY OF , TURB, FR 52L701 (72-52-00-1-20 A)
(4)(X) 1 .HUB 52L601
(4)(W) OR 1 HUB — ASSY OF , TURB, FR 55L221 (72-52-00-1-20 B)
(4)(X) 1 .HUB 55L801
(4)(W) September 23/16 PW4G-1 12-72-342 Page 5
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not subject to the EAR per 15 C.F .R Chapter 1, Part
734.3(b)(3).
T h e m a t e r i a l d a t a t h a t f o l l o w s i s f o r e a c h e n g i n e .
F o r P W 4 0 7 4 D , P W 4 0 7 7 D , P W 4 0 8 4 D , P W 4 0 9 0 , P W 4 0 9 0 - 3 E n g i n e s :
New PN Qty Estimate of Unit Price ($) Keyword Old PN Instructions — Disposition 1 HUB — ASSY OF , TURB, FR 52L901 (72-52-00-1-20)
(4)(X) 1 .HUB 53L001
(4)(W) OR 1 HUB — ASSY OF , TURB, FR 53L121 (72-52-00-1-20 A)
(4)(X) 1 .HUB 53L601
(4)(W) OR 1 HUB — ASSY OF , TURB, FR 53L121-001 (72-52-00-1-20AA)
(4)(X) 1 .HUB 53L601-001
(4)(W) OR 1 HUB — ASSY OF , TURB, FR 55L521 (72-52-00-1-20 C)
(4)(X) 1 .HUB 55L901
(4)(W) M o d i fi c a t i o n a n d S p a r e s I n f o r m a t i o n Estimated part prices are provided when they are available at time of publication.
The Estimate of Unit Price is only for planning purposes and does not constitute a firm quotation.
An asterisk (*) is shown where part pricing information was unavailable.
In either case, contact Pratt & Whitney Spares Management & Logistics for firm quotations.
Parts Modification Conditions
(4) Do an inspection as specified in the Accomplishment Instructions.
Spare Parts A vailability (W) The part is a detail of the assembly and is not procurable as a spare item.
(X) See Reference 2, or 3, Illustrated Parts Catalog for applicable replacement parts.
V endor Services or Special Components/Materials P&W Designation V endor Designation Name V endor Name & Address PMC 4095 V arious Solvent — Scrub Pad V arious Source Code:
V arious See Standard Practices Source Code List PMC 4494 V arious Polyvinyl-siloxane V arious September 23/16 PW4G-1 12-72-342 Page 6
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not Subject to the EAR per 15 C.F .R.
Chapter 1, Part
734.3(b)(3).
P&W Designation V endor Designation Name V endor Name & Address Source Code:
V arious See Standard Practices Source Code List Alternate to PMC 4494 161 16 Reprorubber Quicksetting Putty Flexbar Machine Corp.
250 Gibbs Road Islandia, NY 1 1749-2697 Source Code:
2R260 See Standard Practices Source Code List M a t e r i a l D a t a f o r E a c h S p a r e E n g i n e The material for each spare engine is as stated in the preceding material information section.
R e i d e n t i fi e d P a r t s Not Applicable.
N e c e s s a r y T o o l s No more Support Equipment is necessary .
O t h e r M a t e r i a l I n f o r m a t i o n D a t a Not Applicable.
September 23/16 PW4G-1 12-72-342 Page 7
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not subject to the EAR per 15 C.F .R Chapter 1, Part
734.3(b)(3).
A c c o m p l i s h m e n t I n s t r u c t i o n s P a r t A ( P W 4 0 7 4 D , P W 4 0 7 7 D , P W 4 0 8 4 D , P W 4 0 9 0 a n d P W 4 0 9 0 - 3 m o d e l s )
1.
Disassemble the HPT Module to gain access to the front turbine hub assembly as specified in the Reference 4, Engine Manual, Chapter/Section 72-52-00, Disassembly-01.
2.
Inspect and measure the surface condition of the aft side web/rim fillet of the front turbine hub assemblies as follows.
See Figure
2.
N O T E :
All hubs previously inspected to Reference 6, Special Instructions (SI) 250F-16, or assembly PN 55L521 or PN 55L221 that are marked with detail hub PN 55L901 Revision B or PN 55L801 Revision E or subsequent detail hub revision letters do not require re-inspection.
A.
Clean the hub prior to inspection as follows:
N O T E :
Cleaning can be performed locally when the hub is in the rotor assembly partially disassembled (see Reference 4,Chapter/Section 72-52-00, Disassy
01) or when the HPT stage 2 air seal is removed in the detail piece part condition.
(1) When the hub is installed in the rotor assembly , clean the 1st stage hub rear surface locally per SPOP 208, solvent wipe the area with a PMC 4095 scrub pad followed by a clean cloth wipe.
Refer to Figure
2.
(2) When the hub is in the detail state, clean the 1st stage hub rear surface per Reference 5, CIR Manual Chapter/Section 72-52-00 Cleaning-01.
Refer to Figure
2.
B.
Do an inspection as follows:
(1) Make a replica at four locations approximately 90° apart of the surface of interest using applicable polyvinyl-siloxane impression material per Reference 1, It is acceptable to use Flexbar Machine Corporation’ s™ “Reprorubber Quicksetting Putty”, Model Nos.
16130 or 16131, as an alternate material to PMC 4494 replicating compounds specified in SPOP
127.
(a) The resultant replica should be approximately
1.500 –
2.000 inch (38 –
50.8 mm) in length and look like the illustration in Figure
3.
(2) Create two cuts at the middle of each mold to produce a cross section perpendicular to the circumferential direction.
The slice thickness should not be greater than
0.190 inch
(4.83 mm).
Refer to Figure 4 for an illustration of this requirement.
(3) Install each replica on a Shadowgraph machine and view the image at 20X or greater magnification.
(4) If the mismatch (step) height “H” on the replica (Figure 5 and/or Figure
6) is less than or equal to
0.002 inch
(0.05 mm) the hub is acceptable to continue in service.
N O T E :
A mismatch of
0.002 inch
(0.05 mm) on the replica should measure
0.04 inch
(1.02 mm) on a 20X magnification.
(5) If a feature looks similar to the ones shown in Figure 5 and/or Figure 6, with a mismatch height “H” that is greater than
0.002 inch
(0.05 mm) OR if there is uncertainty in interpreting the inspection results, keep subject part on hold and report the findings to the local Pratt & Whitney local representative.
September 23/16 PW4G-1 12-72-342 Page 8
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not Subject to the EAR per 15 C.F .R.
Chapter 1, Part
734.3(b)(3).
(a) Place all the replication materials in a bag or envelope with the part number , serial number , hours/cycles on the hub and send to the Pratt & Whitney local Field Representative.
(6) If any of the mismatches look like the examples shown in Figure 7, it is most likely a crack.
Place the subject hub on hold and report to Pratt & Whitney per paragraph
5.(a) above.
C.
Mark the hub as follows:
(1) Mark the Service Bulletin Number on the front turbine hub assembly as specified in Reference 1, Standard Practices Manual, Chapter/Section 70-1 1-00, Class
42.
See Figure 8 and Figure 9 for the location of marking.
D.
Report the following information for each front turbine hub inspected.
(1) Provide the inspection result to the Pratt & Whitney local field representative.
Use the format shown in the table that follows for providing inspection results.
PW4000-1 12 Front T urbine Hub Assembly W eb/Rim Fillet Inspection Results — SB PW4G-1 12-72-342 Date Inspected Shop Operator HUB PN HUB SN Hub T otal T ime (TC) Hub T otal Cycles (TC) Mismatch Found?
(Y es/No) Mismatch Description (If Found) September 23/16 PW4G-1 12-72-342 Page 9
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not subject to the EAR per 15 C.F .R Chapter 1, Part
734.3(b)(3).
P a r t B ( P W 4 0 7 4 a n d P W 4 0 7 7 m o d e l s )
1.
Inspect and measure the surface condition of the aft side web/rim fillet of the front turbine hub assembly as follows.
See Figure
2.
N O T E :
All Hubs previously inspected to Special Instructions (SI) 250F-16 or assembly PN 55L521 or PN 55L221 that are marked with detail hub PN 55L901 Revision B or PN 55L801 Revision E or subsequent detail hub revision letters do not require re-inspection.
A.
Clean the hub prior to inspection as follows:
N O T E :
Cleaning can be performed locally when the hub is in the rotor assembly partially disassembled (see Reference 4, Chapter/Section 72-52-00, Disassy
01) or when the HPT stage 2 air seal is removed in the detail piece part condition.
(1) When the hub is installed in the rotor assembly , clean the 1st stage hub rear surface locally per SPOP 208, solvent wipe the area with a PMC 4095 scrub pad followed by a clean cloth wipe.
Refer to Figure
2.
(2) When the hub is in the detail state, clean the 1st stage hub rear surface per Reference 5, CIR Manual Chapter/Section 72-52-00 Cleaning-01.
Refer to Figure
2.
B.
Do an inspection as follows:
(1) Make a replica at four locations approximately 90° apart of the surface of interest using applicable polyvinyl-siloxane impression material per Reference 1, It is acceptable to use Flexbar Machine Corporation’ s™ “Reprorubber Quicksetting Putty”, Model Nos.
16130 or 16131, as an alternative material to PMC 4494 replicating compounds specified in SPOP
127.
(a) The resultant replica should be approximately
1.500 –
2.000 inch (38 –
50.8 mm) in length and look like the illustration in Figure
3.
(2) Create two cuts at the middle of each mold to produce a cross section perpendicular to the circumferential direction.
The slice thickness should not be greater than
0.190 inch
(4.83 mm).
Refer to Figure 4 for an illustration of this requirement.
(3) Install each replica on a Shadowgraph machine and view the image at 20X or greater magnification.
(4) If the mismatch (step) height “H” on the replica (Figure 5 and/or Figure
6) is less than or equal to
0.002 inch
(0.05 mm) the hub is acceptable to continue in service.
N O T E :
A mismatch of
0.002 inch
(0.05 mm) on the replica should measure
0.04 inch
(1.02 mm) on a 20X magnification.
(5) If a feature looks similar to the ones shown in Figure 5 and/or Figure 6, with a mismatch height “H” that is greater than
0.002
(0.05) OR if there is uncertainty in interpreting the inspection results, keep subject part on hold and report the findings to the local Pratt & Whitney local representative.
(a) Place all the replication materials in a bag or envelope with the part number , serial number , hours/cycles on the hub and send to the Pratt & Whitney local Field Representative.
September 23/16 PW4G-1 12-72-342 Page 10
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not Subject to the EAR per 15 C.F .R.
Chapter 1, Part
734.3(b)(3).
(6) If any of the mismatches look like the examples shown in Figure 7, it is most likely a crack.
Place the subject hub on hold and report to Pratt & Whitney per paragraph
5.(a) above.
C.
Mark the hub as follows:
(1) Mark the Service Bulletin Number on the 1st stage hub as specified in Reference 1, Standard Practices Manual, Chapter/Section 70-1 1-00, Class
42.
See Figure 8 and Figure 9 for the location of marking.
D.
Report the following information for each front turbine hub inspected.
(1) Provide the inspection result to the Pratt & Whitney local field representative.
Use the format shown in the table that follows for providing inspection results.
PW4000-1 12 Front T urbine Hub Assembly W eb/Rim Fillet Inspection Results — SB PW4G-1 12-72-342 Date Inspected Shop Operator HUB PN HUB SN Hub T otal T ime (TC) Hub T otal Cycles (TC) Mismatch Found?
(Y es/No) Mismatch Description (If Found) September 23/16 PW4G-1 12-72-342 Page 1 1
UTC/P&W
PROPRIET AR Y
INFORMA TION Subject to the restrictions on the cover or first page.
Not subject to the EAR per 15 C.F .R Chapter 1, Part
734.3(b)(3).
Pratt & Whitney A United Technologies Company
FRONT TURBINE HUB ASSEMBLY -
INSPECT AS SPECIFIED IN THE ACCOMPLISHMENT INSTRUCTIONS.
B526424
LOCATION OF THE FRONT TURBINE HUB ASSEMBLY 72-52-00 FIGURE 1 September 23/16 PW4G-112-72-342 Page 12
UTC/P&W PROPRIETARY INFORMATION Subject to the restrictions on the cover or first page.
Not Subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3).