duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '3805c39655fa31e0a1c668722c608647551c7712c9721e79941257640e6c4087' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '3805c39655fa31e0a1c668722c608647551c7712c9721e79941257640e6c4087' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
This document transmits Revision 4 to Service Bulletin RB211-72-AG774 Document History Service Bulletin Revision Status Supplement Revision Status Initial Issue Mar.20/12 Revision 1 Jul.31/13 Revision 2 Dec.23/14 Revision 3 Sep.24/15 Bulletin Revision 4 Remove Incorporate Reason for change All pages of the Service Bulletin Pages 1 to 33 of the Service Bulletin To extend the date of compliance.
All pages of Appendix 1 Page 1 of Appendix 1 To extend the date of compliance.
All pages of Appendix 2 Pages 1 to 10 of Appendix 2 To extend the date of compliance.
All pages of Appendix 3 Pages 1 to 3 of Appendix 3 To extend the date of compliance.
All pages of Appendix 4 Page 1 and 2 of Appendix 4 To extend the date of compliance.
All pages of Appendix 5 Pages 1 to 4 of Appendix 5 To extend the date of compliance.
Printed in Great Britain Oct.13/20 RB211 TRENT 800 SERIES PROPULSION SYSTEMS NON-MODIFICATION SERVICE BULLETIN RB.211−72−AG774 Transmittal - Page 1 of 3 Date ALERT ALERT
CHECK THAT ALL PREVIOUS TRANSMITTALS HAVE BEEN INCORPORATED If any have not been received please advise Customer Data Services, Rolls-Royce plc, Derby, England ©Rolls-Royce plc (date as above) Printed in Great Britain
LIST OF EFFECTIVE PAGES The effective pages to this Service Bulletin following incorporation of Revision 4 are as follows:
Page Revision Number Revision Date Bulletin R 1 4 Oct.13/20 R 2 4 Oct.13/20 R 3 4 Oct.13/20 R 4 4 Oct.13/20 R 5 4 Oct.13/20 R 6 4 Oct.13/20 R 7 4 Oct.13/20 R 8 4 Oct.13/20 R 9 4 Oct.13/20 R 10 4 Oct.13/20 R 11 4 Oct.13/20 R 12 4 Oct.13/20 R 13 4 Oct.13/20 R 14 4 Oct.13/20 R 15 4 Oct.13/20 R 16 4 Oct.13/20 R 17 4 Oct.13/20 R 18 4 Oct.13/20 R 19 4 Oct.13/20 R 20 4 Oct.13/20 R 21 4 Oct.13/20 R 22 4 Oct.13/20 R 23 4 Oct.13/20 R 24 4 Oct.13/20 R 25 4 Oct.13/20 R 26 4 Oct.13/20 R 27 4 Oct.13/20 R 28 4 Oct.13/20 R 29 4 Oct.13/20 R 30 4 Oct.13/20 R 31 4 Oct.13/20 R 32 4 Oct.13/20 R 33 4 Oct.13/20 Appendix 1 R 1 4 Oct.13/20 Appendix 2 R 1 4 Oct.13/20 R 2 4 Oct.13/20 R 3 4 Oct.13/20 R 4 4 Oct.13/20 R 5 4 Oct.13/20 R 6 4 Oct.13/20 Printed in Great Britain RB.211−72−AG774 Transmittal - Page 2
R 7 4 Oct.13/20 R 8 4 Oct.13/20 R 9 4 Oct.13/20 R 10 4 Oct.13/20 Appendix 3 R 1 4 Oct.13/20 R 2 4 Oct.13/20 R 3 4 Oct.13/20 Appendix 4 R 1 4 Oct.13/20 R 2 4 Oct.13/20 Appendix 5 R 1 4 Oct.13/20 R 2 4 Oct.13/20 R 3 4 Oct.13/20 R 4 4 Oct.13/20 Printed in Great Britain RB.211−72−AG774 Transmittal - Page 3
1. Planning Information A. Effectivity Boeing 777 RB211 TRENT 875-17 Engines pre SB72-G581 Part 1 RB211 TRENT 877-17 Engines pre SB72-G581 Part 1 RB211 TRENT 884-17 Engines pre SB72-G581 Part 1 RB211 TRENT 884B-17 Engines pre SB72-G581 Part 1 RB211 TRENT 892-17 Engines pre SB72-G581 Part 1 RB211 TRENT 892B-17 Engines pre SB72-G581 Part 1 RB211 TRENT 895-17 Engines pre SB72-G581 Part 1 B. Reason
(1) Problem A number of LP compressor front case assemblies have exhibited corrosion to the casing Isogrid structure under the Kevlar wrap. The corrosion has been identified during engine overhaul by bulging of the Kevlar wrap or the rear titanium fire shield.
The LP compressor front case is protected by an anti-corrosion paint that is susceptible to frettage from the Kevlar wrap during engine operation.
To prevent this occurrence a thin layer of Silcoset is applied, at manufacture, onto the case prior to applying the Kevlar wrap. However, it has been determined that excessive movement between the Kevlar wrap and fan case has resulted in the Silcoset and anti-corrosion paint fretting away.
The corrosion occurs due to salt water ingress beneath the rear of the Teflon sleeve resulting in pooling within the Isogrid pockets and saturation of the Kevlar wrap. The salt water corrosively attacks the exposed case material in areas where frettage has occurred. The water enters underneath the Teflon sleeve due to a poor seal or debond of the adhesive joint between the Teflon sleeve and the titanium rear fire shield.
Unacceptable levels of corrosion may affect the containment integrity of the LP compressor front case during a fan blade release event.
ENGINE - LP COMPRESSOR CASE - INSPECTION FOR CORROSION ON FRONT CASE - NON-MODIFICATION SERVICE BULLETIN - NON - MOD.72-AG774 Printed in Great Britain RB.211−72−AG774 Page 1 of 33 Mar.20/12 Oct.13/20R
C. Description This Non-Modification Service Bulletin (NMSB) is issued to introduce a once round the fleet in-shop LP compressor front case ultrasonic inspection and acceptance criteria for corrosion.
Accomplishment of this NMSB must be recorded in the engine/module log book.
Results of the inspection must be retained with a copy kept in two separate locations of the overhaul shop records to protect the data for future reference.
Complete the results sheets in Appendi x 3 / Appendix 4, the proforma in Appendix 5 and send to Rolls-Royce via your local service representative.
Revision 1 of this NMSB was issued to include reference to SB72-G856 and to clarify the inspection limits on corrosion present on the LP front fan case.
Revision 2 of this NMSB was issued to improve the clarity of the Acceptance Criteria Limits contained in Appendix 2 following service experience, and refine text in the accomplishment instructions. These changes are in line with the intent of the original revision.
Revision 3 of this NMSB wasR issued to extend the compliance date to 30th April 2020, add OMat 679 reference for corrosion inhibitor (Polyhib) and to change the figure in Appendix 4. This revision also correctedR the typographical errors noted in the previous issue of this NMSB.
Revision 4 of this NMSB is issued to extend the compliance date to 31st October 2024.
R R D. Compliance ALERT Revision 4 of this Non-Modification Service Bulletin is anticipated to be the subject of an EASA Airworthiness Directive (AD).
R R Rolls-Royce recommends that the following action is undertaken to maintain reliability.
This Non-Modification Service Bulletin must be accomplished at shop visit, on all pre SB72-G581 Part 1 LP compressor front cases no later than 31st October 2024, R R where the engine is subject to a level greater than, but not including, serviceability.
Inspect at next shop visit post the issue of this bulletin for those engines not currently inducted, and during shop visit for those engines currently in the shop where the affected part is exposed and substantial rebuild has not yet started.
Printed in Great Britain RB.211−72−AG774 Page 2 Mar.20/12 Oct.13/20R
E. Approval The technical content of this Non-Modification Service Bulletin was approved under the authority of Design Organisation Approval EASA.21J.035 on Mar.9/12, Jun.24/13, Dec.12/14 and was re-approved on Sep.18/15.
The technical content of this Non-Modification Service Bulletin was approved under the authority of Design Organisation Approval EASA.21J.065 on Oct.1/20.
R R F. Manpower
(1) Time to gain access 15 hours (2 persons)
(2) Time to inspect 8 hours (2 persons) NOTE : The ultrasonic inspection defined in Section 3. Accomplishment Instructions must be performed by personnel qualified to ultrasonic inspection level 2 or higher in accordance with EN4179/NAS-410 or alternative standards/guidelines accepted by the applicable National Aviation Authority.
Additionally, all inspection personnel utilising this technique must have received specific training and approval either directly from or by personnel trained by the Rolls-Royce NDE Laboratory.
(3) Time to restore to serviceable condition Not Applicable - Refer to Section 3. Accomplishment Instructions G. Material Price and Availability None H. Tooling Price and Availability
(1) Equipment - Ultrasonic Inspection Description Part Number Inspection Kit USN52 Ultrasonic Flaw Detector or similar Lemo-BNC Adaptor HU44849 NOTE : Item HU44849 is supplied by Rolls-Royce.
Printed in Great Britain RB.211−72−AG774 Page 3 Mar.20/12 Oct.13/20R
(2) Consumable Materials Description Part Number Ultrasonic Couplant OMat 655 Temporary marker felt/fibre tip OMat 262 or equivalent Corrosion inhibitor (Polyhib) OMat 679 I. References
(1) Rolls-Royce RB211 Service Bulletins:
(a) 72-G581 Engine - LP compressor front case - Introduction of a revised LP compressor front case with corrosion protection
(b) 72-G634 Engine - LP compressor front case - Introduction of reworked LP compressor front case assemblies with revised corrosion protection
(c) 72-G856 Engine - LP Compressor Front Case - Introduction of a Reworked LP Compressor Front Case Assembly with revised Corrosion Protection and Reworked Circumferential Brackets Featuring Dry Film Lubricant
(2) Engine Manual:
(a) 72-34-00, Disassemble the Low Pressure (LP) Compressor Case
(b) 72-34-14, LP Compressor Front Case - Disassembly
(c) 72-34-14, LP Compressor Front Case - Cleaning Printed in Great Britain RB.211−72−AG774 Page 4 Mar.20/12 Oct.13/20R
2. Material Information None Printed in Great Britain RB.211−72−AG774 Page 5 Mar.20/12 Oct.13/20R
3. Accomplishment Instructions A. Prepare LP compressor front case for inspection.
(1) Remove the ice impact panels in accordance with Engine Manual, 72-34-00, Disassembly.
(2) Remove the acoustic panels in accordance with Engine Manual, 72-34-00, Disassembly.
(3) Remove the acoustic panel support brackets in accordance with Engine Manual, 72-34-14, Disassembly.
NOTE : Make sure all serviceable hardware is retained for reuse.
(4) Clean the inner surface of the LP compressor front case approximately 60 degrees either side of Bottom Dead Centre (BDC) in accordance with Engine Manual, 72-34-14, Cleaning.
B. Ultrasonic inspection of the LP compressor front case.
(1) The ultrasonic inspection of the LP compressor front case is in two parts.
(a) Part A inspection will ultrasonically identify corrosion on the surface (back wall) of the pocket areas and parts of the Isogrid bosses using the Sonatest RapidScan2 system.
(b) Part B inspection will ultrasonically identify the outer surface (back wall) of the Isogrid web and bosses using a single element ultrasonic transducer.
NOTE : All inspection personnel utilising this technique must have received specific training and approval either directly from or by personnel trained by the Rolls-Royce NDE Laboratory.
(2) Part A - Ultrasonic inspection using the Sonatest RapidScan2 system.
(a) Prepare the RapidScan ultrasonic equipment.
NOTE : All RapidScan equipment should be connected together before turning the power switch on. The equipment is suitable for 110V or 220V AC power 50-60 Hz.
(b) Insert the mains cable into the RapidScan unit. If the button does not illuminate when switching on check the fuse (located below the socket).
Printed in Great Britain RB.211−72−AG774 Page 6 Mar.20/12 Oct.13/20R
CAUTION : APPLICATION OF FORCE WILL DAMAGE THE PROBE CONNECTOR
(c) Connect the wheel probe to the RapidScan by plugging in the large multi-way connector. With the connector unplugged, turn the black handle on the connector to the open position and offer the connector up to the RapidScan unit. No force should be required in order to do this. If the connector does not fit with zero force applied, check the condition of the connector terminal pins. With the connector in place, turn the handle to the lock position.
(d) Insert the wheel-probe encoder connector into the encoder port 1 on the RapidScan unit.
CAUTION : THE MAIN UNIT POWER MUST BE SWITCHED ON AND THE PCMCIA ADAPTER
CONNECTED TO THE LAPTOP BEFORE THE LAPTOP IS SWITCHED ON
(e) Make sure the PCMCIA card is inserted into the PCMCIA port on the laptop and connect power to the laptop.
(f) Make sure the wheel transducer is completely filled with distilled water and 20 drops of OMat 679 Corrosion inhibitor (Polyhib).
NOTE : The wheel transducer must be drained and refilled with distilled water and OMat 679 Corrosion inhibitor (Polyhib) on a weekly basis and should not be left full of water for a sustained period.
The wheel transducer is drained and filled by removing the two screw caps in the end cap of the wheel (see Fig.1). After filling, these should be firmly replaced. Make sure that draining and re-filling of the wheel-probe is performed at least 1 metre away from the main RapidScan unit in a location suitable for wet processes to avoid water ingress into the system.
(g) Start up RapidScan.
(h) Logon to the laptop as Operator.
(i) Double click on the RapidScan2 desktop icon or start from the Windows start menu.
(j) The initial screen allows the user to enter the desired program mode.
The menu buttons in the top left-hand corner perform the following functions:
New C - Start a new C-scan session New T - Start a new T-scan session - stitch C-scans together Load - Load a previously saved C or T-scan session Printed in Great Britain RB.211−72−AG774 Page 7 Mar.20/12 Oct.13/20R
Save - Save saCo r T-scan session or particular instrument settings Close - Close current session - Exits Rapidscan if session is closed CAUTION : ACTIVATION OF THE NEW C BUTTON ONLY OCCURS IF THE COMPUTER ON WHICH THE SOFTWARE IS RUNNING IS CONNECTED TO RAPIDSCAN HARDWARE.
IF THE NEW C BUTTON IS UNEXPECTEDLY UNAVAILABLE (GREYED OUT) THEN
SHUT DOWN THE LAPTOP AND TURN OFF THE ILLUMINATED POWER SWITCH ON THE RAPIDSCAN UNIT. CHECK THE PCMCIA CARD IS FULLY INSERTED AND THAT THE CABLE IS CORRECTLY SCREWED IN TO THE CARD. SWITCH ON THE
RAPIDSCAN UNIT AND RESTART THE LAPTOP
(k) Click on the New C tab on the start up screen and import the settings file by clicking on Settings menu 1 and clicking Import New.
(l) Select settings file RollsRoyceCAL2 and click Open.
(m) Calibrate the RapidScan system.
(i) Check that the array is normalised for flat plate by using the adjustment slide on the side of the probe. The pin should be as far up the slot as possible and then tightened.
(ii) Check the water path (P.Zero) and the sensitivity across the array using working standard plate HU44852.
(iii) Position the wheel probe at one end of the working standard plate HU44852. Make sure the array is away from the holes and slot.
(1) Make sure couplant is applied and press down on the probe handle until both red wheels are contacting the working standard and the wheel tyre is in full contact across the full width.
(2) In Settings menu 2 check P.Zero (water path) is set correctly. This is when the first signal is about 10 per cent across the time base, when the probe is firmly pressed on to the plate. (See the P.Zero setting on the Settings Card for the approximate value).
(3) In the A-Scan menu click on the Extrema button and adjust the gain to maximise the signal envelope but make sure that no signals are above 100 per cent Full Screen Height (FSH) in Gate 1 and therefore saturated otherwise sensitivity calibration cannot be carried out (Aim for 80 per cent minimum). After checking, turn off Extrema.
(4) Sensitivity setting of the array is carried out in Settings menu 3.
Printed in Great Britain RB.211−72−AG774 Page 8 Mar.20/12 Oct.13/20R
(5) Continue to press down on the probe handle, keeping the red wheels in contact with the plate and the wheel tyre in full contact across the full width.
(6) Make sure that the control for QN Gate is set to Gate 1 and that the Back Wall Echo (BWE) is covered by Gate 1 (RED).
Refer to Fig.2.
(7) Click on the Q Norm button (if a reminder pops up relating to Q Norm in the inspection tools menu, click OK). This equalises sensitivity across all array elements.
NOTE : If an error message appears relating to some signals being clipped then return to the A-Scan menu to decrease the gain and make sure no signals are above 100 per cent FSH in Gate 1.
(8) Sensitivity calibration is now complete and when rolling the probe over the working standard plate, the B-Scan should show equal response across the probe array.
NOTE : The gate settings are preset in the RollsRoyceCAL2 settings file but can be checked as detailed in Appendix 1.
(n) Scan the Working Standard.
(i) The length of the scan to be carried out must be set correctly in the C-Scan menu at 350 mm.
NOTE : Scanning speed is dependent on the Pulse Repetition Frequency (PRF) in the A-Scan menu (this will be pre-set, see Settings Card for the correct value). If the maximum scanning speed is exceeded this will be seen as lines across the C-Scan where data collection is incomplete.
Maximum scanning speed allowable is indicated as a green pointer on the Y-axis of the C-Scan when a scan is in progress.
(ii) Normal scanning must be carried out from left to right when looking at the probe from the Non-Encoder Side as shown in Fig.3.
(iii) Apply a fine water spray to the top surface of the working standard HU44852 to act as a couplant and position the wheel probe at the left hand end of the plate with the end of the rear roller aligned against the top left hand edge as shown in Fig.4.
(iv) Apply an even pressure to make sure that the probe is in full contact across its width.
Printed in Great Britain RB.211−72−AG774 Page 9 Mar.20/12 Oct.13/20R