duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '8beaaad9a61c5085406405e78fcaff9eb78fe1c3f4aa42a40673a0b8de63fd8b' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '8beaaad9a61c5085406405e78fcaff9eb78fe1c3f4aa42a40673a0b8de63fd8b' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
Service Bulletin 19 April 2018
2000ï28ï028 Page 1 of 4 ATA CHAPTER: 28 FUEL ï PROBES ï INSPECTION OF OVERREADING FUEL PROBES Mod No. ï
1. PLANNING INFORMATION A. EFFECTIVITY
(1) Aircraft:
Aircraft Mfg. Serial No’s SAAB 2000 ï 004 thru ï 063.
(2) Spares: Not affected.
B. REASON Saab has investigated the fuel probes, due to reports from operators with misleading fuel quantities displayed on EICAS. The investigation points at an ageing problem, where the probes slowly deteriorates. One cause is the contamination of the tubes and tube spacers, which changes the capacity of the probe and causes the probes to read too high or low. Another cause is component failures and/or corroded terminals. This Service Bulletin is issued to ensure correct fuel quantity indication in cockpit.
This Service Bulletin introduce a test procedure for the probes.
In addition a new repetitive inspection will be added in the Airworthiness Limitation Manual (ALM) to ensure continued airworthiness.
C. DESCRIPTION This Service Bulletin gives instructions for:
ï fill up the fuel tanks to mid level ï inspection of the low fuelïlevel sensors ï inspection of fuel quantity probes If necessary:
ï removal of the access door of the fuel tank ï removal the fuel quantity probes ï removal of the low fuelïlevel sensors ï inspection of the low fuelïlevel sensors ï inspection of fuel quantity probes ï installation of the low fuelïlevel sensors ï installation the fuel quantity probes ï installation of the access door of the fuel tank.
D. COMPLIANCE Mandatory.
Saab recommends this Service Bulletin to be performed within 12 months / 1500 flight hours from release of this Service Bulletin This Service Bulletin is under EASA consideration for an Airworthiness Directive.
The final compliance terms will be set by the EASA Airworthiness Directive (AD) when issued.
E. APPROVAL The technical content of this Service Bulletin is approved under the authority of DOA nr.
EASA.21J.066.
Service Bulletin 19 April 2018
2000ï28ï028 Page 2 of 4 F. MANPOWER Estimated time to complete the inspection in this Service Bulletin is:
2 persons required.
Total manhours: 8 Elapsed time (hours): 4 Labour cost at operators expense.
G. MATERIAL ï COST AND AVAILABILITY Ensure the availability of probes with Saab spare department before inspection.
H. TOOLING No special tooling required.
I. WEIGHT AND BALANCE None.
J. ELECTRICAL LOAD DATA Not affected.
K. REFERENCES Aircraft Maintenance Manual (AMM) 08 ï20ï00ï586ï801 12ï10ï28ï600ï803 12ï10ï28ï600ï803 12ï10ï28ï600ï809 24ï00ï00ï860ï801 24ï00ï00ï860ï802 28ï41ï10ï000ï801 28ï41ï10ï400ï801 28ï41ï10ï720ï801 28ï41ï15ï000ï801ï806 28ï41ï15ï000ï807ï808 28ï41ï15ï400ï801ï806 28ï41ï15ï400ï807ï808 57ï27ï15ï000ï801 57ï27ï15ï400ï801 Service News Letter (SNL) 2000 ï1708 Component Maintenance Manual (CMM) UTC (Formerly Simmonds) 28ï45ï03 L. OTHER PUBLICATIONS AFFECTED Aircraft Maintenance Manual (AMM) Airworthiness Limitation Manual (ALM)
Service Bulletin 19 April 2018
2000ï28ï028 Page 3 of 4
2. ACCOMPLISHMENT INSTRUCTIONS A. JOB SET ïUP
(1) Before you start the SB, make sure:
ï The documentation is available ï The exchange probes are i stock.
(2) Make sure aircraft is laterally levelled within +/ ï 1 degree. If necessary, level the aircraft (Ref.
AMM 08ï20ï00ï586ï801).
(3) Make sure that the total fuel quantity is approximately 4630 lb (2100 kg), evenly distributed in the wings. If necessary, adjust the fuel quantity (Ref. AMM 12ï10ï28ï600ï801 or 12ï10ï28ï600ï803).
(4) Supply the External AC Power (Ref. AMM 24 ï00ï00ï860ï801).
B. INSPECTION
(1) General
(a) This procedure to do a functional check of the fuel quantity system and the Low Level warnings. This procedure intends to ensure the low level warnings and fuel measurement works as intended. Before removal of faulty probes, ensure exchange probes in stock.
C. FUNCTIONAL TEST
(1) Do a check of the fuel indicator gauging accuracy and the low level warning.
(a) Check the fuel quantity as indicated on the refuel/defuel quantity on the wing fueling panel and EICAS in the flight compartment. Make a record of the results.
(b) Use the magnetic fuel level indicator and check the fuel quantity in the LH and RH outboard tanks. Make a record of the results.
(c) Compare the result from step (a) and (b) and make sure the fuel indicator values are within +/ï165 lbs (75 kg) per side.
NOTE: If the indicator values are out of tolerance, further investigation shall be done to find the source of error. For guidance (Ref. SN 2000ï1708, CMM 28ï45ï03).
Replace fuel probes as required.
(d) Ensure no low level caution (L or R) alerts.
(e) Transfer fuel from right tank to left tank by using R PUMP (Ref. AMM 12ï10ï28ï600ï809). Monitor the transfer on EICAS, the amount should increase/decrease in the wing tanks without any scatter, when warning R FUEL QTY LO appears on PED, immediately terminate the transfer.
(f) Use the inner magnetic fuel level indicator and check the fuel quantity in the RH inboard tank. The value shall be 430 +/ï 100 liters (114 +/ï 26 US gals).
NOTE: If the Low Level warning is out of tolerance, further investigation shall be done to find the source of error (Ref. AMM TASK 28-41-10-720-801). Replace low level sensors as required.
(g) Transfer fuel from right tank to left tank by using R PUMP (Ref. AMM 12-10-28-600-809).
Monitor the transfer on EICAS, the amount should increase/decrease in the wing tanks without any scatter, stop when the quantity displayed on EICAS for left tank is 4300 lb (1950 kg).
(h) Do step (a) to (c) again for right tank.
(i) Transfer fuel from left tank to right tank by using L PUMP (Ref. AMM 12-10-28-600-809).
Monitor the transfer on EICAS, the amount should increase/decrease in the wing tanks without any scatter, when warning L FUEL QTY LO appears on PED, immediately terminate the transfer.
Service Bulletin 19 April 2018
2000ï28ï028 Page 4 of 4
(j) Use the inner magnetic fuel level indicator and check the fuel quantity in the LH inboard tank. The value shall be 430 +/ï 100 liters (114 +/ï 26 US gals).
NOTE: If the Low Level warning is out of tolerance, further investigation shall be done to find the source of error (Ref. AMM TASK 28-41-10-720-801). Replace low level sensors as required.
(k) Transfer fuel from left tank to right tank by using L PUMP (Ref. AMM 12ï10ï28ï600ï809). Monitor the transfer on EICAS, the amount should increase/decrease in the wing tanks without any scatter, stop when the quantity displayed on EICAS for right tank is 4300 lb (1950 kg).
(l) Do step (a) to (c) again for left tank.
(m) Transfer fuel to the LH tank until the quantity for LH and RH reads same quantity.
D. JOB CLOSE ïUP
(1) Remove all tools and equipment from the work area. Make sure that the work area is clean.
(2) Remove the External AC Power (Ref. AMM 24 ï00ï00ï860ï802).
3. MATERIAL INFORMATION NOTE: If you need to replace parts:
A. Fuel probes:
Item Part Number Qty Nomenclature Designation Remarks 20136ï0101 Fuel Probe 20136ï0102 Fuel Probe 20136ï0103 Fuel Probe 20136ï0104 Fuel Probe 20136ï0105 Fuel Probe 20136ï0106 Fuel Probe B. Low level sensor Item Part Number Qty Nomenclature Designation Remarks 20137ï0101 Level Sensor