Service Bulletin 20 August 2015

2000–38–012 Page 1 of 10 ATA CHAPTER: 38 WATER / WASTE – POTABLE WATER SYSTEM – INSTALLATION OF SHRINKABLE

TUBES AS SPRAY SHIELDS Mod No. 6530

1. PLANNING INFORMATION A. EFFECTIVITY

(1) Aircraft:

Aircraft Mfg. Serial No’s SAAB 2000 – 017, 019–021, 027–028, 030, 034, 040, 050 and 052.

(2) Spares: Not affected.

B. REASON One occurrence of rudder pedal restriction has been reported on an aircraft with the larger potable water system equipped with in–line heaters (option 38:201 and 38:201–1).

Subsequent investigation showed that this was the result of a ruptured in–line heater attachment, which resulted in water spraying in the area (Zone 116) during refilling on ground.

Frozen water on the rudder control mechanism in Zone 116 then led to the rudder pedal restriction.

Analysis after the reported event indicates that the pitch control mechanism (including pitch disconnect/spring unit) may also be frozen as a result of water spray, which would prevent disconnection and normal pitch control. The analysis also indicated that a failed water tubing could lead to a water spray potentially resulting in the same scenario as above.

This condition, if not corrected, could result in occurrences of reduced control of the aircraft and a potential unsafe condition.

This Service Bulletin, applicable for aircraft equipped with the smaller potable water system (without the in–line heater), is issued in order to remove the risk for uncontrolled leakage of water tubing/couplings and water spray in zone 116 that may cause frozen parts of the flight control system.

C. DESCRIPTION This Service Bulletin gives instructions for installation of shrinkable tubes as spray shields over the water pipes in zone 116 and 118 (REF. FIG. 1).

D. COMPLIANCE Mandatory.

Saab recommends this Service Bulletin to be performed within 24 months from release of this Service Bulletin This Service Bulletin is under EASA consideration for an Airworthiness Directive.

The final compliance terms will be set by the EASA Airworthiness Directive (AD) when issued.

E. APPROVAL This Service Bulletin is developed and approved under the authority of DOA nr. EASA.21J.066. The change addressed in the bulletin is classified as ”Major” in accordance with EC regulation 748/2012 Part 21A.91 and is approved by the European Aviation Safety Agency. Ref. EASA Major Change Approval 10054453.

Service Bulletin 20 August 2015

2000–38–012 Page 2 of 10 F. MANPOWER Estimated time to complete this Service Bulletin is:

1 persons required.

Total manhours: 6 Elapsed time (hours): 6 Labour cost at operators expense.

G. MATERIAL – COST AND AVAILABILITY Price and availability for Mod Kit. No. SAAB 2000–38–012–01 will be furnished on request.

H. TOOLING No special tooling required.

I. WEIGHT AND BALANCE Weight change 0.2 kg / 0.44 lb Center of gravity STA 190.0 Change moment 0.38 kgin / 0.84 lbin 100 J. ELECTRICAL LOAD DATA Not affected.

K. REFERENCES Aircraft Maintenance Manual (AMM) 06–41–00–00 TASK 12–10–38–610–801 TASK 12–10–38–680–801 L. OTHER PUBLICATIONS AFFECTED Aircraft Maintenance Manual (AMM) Illustrated Parts Catalog (IPC)

2. ACCOMPLISHMENT INSTRUCTIONS A. JOB SET–UP

(1) Before you start the SB, make sure:

– The modification kit contains the parts listed in the Service Bulletin – The documentation is available.

(2) Drain the potable water system (Ref. AMM TASK 12–10–38–680–801).

(3) Get access

(a) Remove the access panels 116AR and 118AR (Ref. AMM 06–41–00–00).

Service Bulletin 20 August 2015

2000–38–012 Page 3 of 10 B. MODIFICATION REF. FIG. 2

(1) Make the evacuation holes in the shrinkable tube (2).

(a) On the shrinkable tube (2), measure and mark out the position for the 7 cut outs (evacuation holes) (Ref. View C).

(b) Use a sharp tool and carefully make the 7 cut outs.

(2) Remove the tube assy (7).

(a) Loosen the nuts (6 and 8).

(b) Remove the tube assy (7) from the reducer (9) and the filling adaptor (5). Keep the tube assy (7) for installation.

(3) Install the shrinkable tube (the tube) (2) (Ref. View A–A, B–B, D)

(a) Remove the reducer (9) from the water pipe (11). Keep the reducer (9) for installation.

(b) From between STA 186.0 and 215, remove one screw each from the two two existing clamps that attach the water pipe (11).

(c) Remove and discard the two cushions that is installed between the existing clamps and the water pipe (11).

(d) Use masking tape or equivalent to hold the nut of the water pipe (11) in position during installation of the tube (2).

(e) Carefully slide the tube (2) over the water pipe (11). Make sure that the evacuation holes are facing outboard, against the skin of the lower fuselage.

(f) Position a suitable plate or equivalent as a heat shield in order to protect the existing harnesses, adjacent to the water pipe (11) when you shrink the tube (2).

(g) With the evacuation holes in correct position, use the heat gun and carefully shrink the tube (2) at:

– the two clamp points (Ref. View A–A) – the forward end of the water pipe (11) (Ref. View D).

NOTE: Do not install the two clamps at this time.

(h) Remove the plate installed in step (f).

(4) Install the shrinkable tube (the tube) (3) (Ref. View B–B, E).

(a) Slide the tube (3) over the forward part of the water pipe (11) and part of the tube (2).

(b) Install the reducer (9) on the water pipe (11). Hold the union of the water pipe (11) and tighten the reducer (9).

(c) Make sure the tube (3) cover the union of the water pipe (11) and the fwd end of the tube

(2) (Ref. View E).

(d) Use a heat gun and shrink the tube (3).

(5) Install the tube assy (7) and the shrinkable tube (the tube) (1) (Ref. View B–B, F).

(a) Prior installation, push the tube (1) over the tube assy (7).

(b) Install the tube assy (7).

1 Put the tube assy (7), with the tube (1) in correct position against the reducer (9) and the filling adaptor (5).

2 Tighten the nuts (6 and 8).

3 Push the tube (1) aft and over the reducer (9) and the forward part of the already installed tube (3) (Ref. View F).

Service Bulletin 20 August 2015

2000–38–012 Page 4 of 10 4 Use the heat gun and fully shrink the upper/aft part of the tube (1), around the reducer (9) and the tube (3).

5 At the lower/forward part of the tube (1), carefully shrink until there is an equal gap of approximately 3–5 mm (0.12–0.20 in) to the tube assy (7). Make sure that the lower end of the tube (1) cover the filling adaptor (5).

NOTE: Locally, it is acceptable if the tube (1) is tight against the tube assy (7).

6 Install the strap (4) and make sure there is a tight fit against the installed tube (3).

(c) Install and tighten the two removed screws for the clamps that attach the water pipe (11).

C. JOB CLOSE–UP

(1) Fill the potable water system (Ref AMM TASK 12–10–38–610–801) and at the same time, make sure that there is no visible water leakage.

(2) Close the access.

(a) Remove the tools and equipment from the work area. Make sure the work area is clean.

(b) Install the access panels 116AR and 118AR (Ref. AMM 06–41–00–00).

(c) Close the water service door 118BR (Ref. AMM 06–41–00–00).

(3) Remove the tools and equipment from the work area. Make sure the work area is clean.

3. MATERIAL INFORMATION A. Modification Kit No SAAB 2000–38–012–01 contains:

Item Part Number Qty Nomenclature Designation Remarks 1 RNF–100–2–0 1 Shrinkable tube – Length:

240 mm

(9.45 in) 2 RNF–100–1 1/4–0 1 Shrinkable tube – Length:

850 mm

(33.50 in) 3 RNF–100–1 1/4–0 1 Shrinkable tube – Length:

70 mm

(2.76 in) 4 TY28M O/T T50L.NN O/T 111–05409 O/T PLT4S 1 Strap – –

Service Bulletin 20 August 2015

2000–38–012 Page 5 of 10 B19039

SHRINKABLE TUBE STRAP

SHRINKABLE TUBE

REDUCER

WATER TUBE CLAMPS

PRE MOD POST MOD

Shrinkable Tube / Spray Shield – Description FIG. 1

Service Bulletin 20 August 2015

2000–38–012 Page 6 of 10

THIS PAGE INTENTIONALLY LEFT BLANK

Service Bulletin 20 August 2015

2000–38–012 Page 7/8 of 10 5 6 7 89 11 1 2 7 REF 6 REF 5 REF 1 REF 8 REF 9 REF 11 REF 4 3 B19037

Shrinkable Tube – Installation FIG. 2 (Sheet 1 of 2)

Service Bulletin Date Month Year Revison X, Date Month Year 2000–XX–XXX Page 8

Service Bulletin 20 August 2015

2000–38–012 Page 9/10 of 10 5 mm (0.2 in) R 5 mm (0.2 in) 850 mm (33.5 in) 100 mm (3.94 in) 7 X 100 mm (= 700 mm) (7 X 3.94 in (= 27.6 in)) REF 2 REF B19038 9 REF 3 REF 9 REF 2 REF 1 REF 2 REF 3 REF 4

Shrinkable Tube – Installation FIG. 2 (Sheet 2 of 2)

Service Bulletin Date Month Year Revison X, Date Month Year 2000–XX–XXX Page 10