CL-215 MAINTENANCE MANUAL PSP 292 TR 25–27 Page 1 of 4 Apr 13/2225–70–00

TEMPORARY

REVISION

TEMPORARY

REVISION EFF: Aircraft Serial Nos. 1001 to 1055, 1058 to 1060, 1062 to 1079, 1081 to 1108, 1110 to 1112, and 1123 TEMPORARY REVISION NO. 25–27 FILING INSTRUCTIONS: Insert Temporary Revision (TR) 25–27 into Chapter 25–70–00, before Page 501.

Record the insertion of this Temporary Revision (TR) 25–27, on the yellow RECORD OF TEMPORARY REVISIONS sheet at the front of Volume 1.

Keep this Temporary Revision until normal revision service incorporates this information into the Maintenance Manual.

DESCRIPTION: This Temporary Revision introduces Mod CL/0076, Water Drop System – Hydraulic Solenoid Electrical Back-EMF Protection.

— Continued Overleaf —

CL-215 MAINTENANCE MANUAL PSP 292 TR 25–27 Page 2 of 4 Apr 13/2225–70–00

TEMPORARY

REVISION

TEMPORARY

REVISION EFF: Aircraft Serial Nos. 1001 to 1055, 1058 to 1060, 1062 to 1079, 1081 to 1108, 1110 to 1112, and 1123 AERIAL FIRE-FIGHTING SYSTEM − ADJUSTMENT/TEST

1. Adjustment/Test Equipment and Materials:

A. Preparation

(1) Apply external DC power. Refer to Chapter 24.

(a) Connect test stand to hydraulic test connections. Refer to Chapter 29.

(b) Check fluid level in hydraulic reservoir. Refer to Chapter 12.

NOTE: Fluid level must be maintained between ADD and FULL during functional checks.

(c) Check shock struts for proper inflation. Refer to Chapter 12.

DESCRIPTION PART NO./

SPECIFICATION

UNITS PER

ASSEMBLY ITEM NO.

Hydraulic test stand 05-7024-1200 – – Hunter force gauge Model HSD200, or equivalent – – Pilot Static System Test Set Barfield Instrument Corp.

Model 1811H635-110 (100 VAC), or 1811H635-220 (220 VAC), or equivalent –– Stop watch – – – Lockwire MS20995CY20 AR – Leak detection fluid MIL-L-25567, Type 1 – – Source of regulated low pressure air (2.5 PSI) –– – Water supply – – – Digital Multimeter Fluke Model 87, or equivalent – –

CL-215 MAINTENANCE MANUAL PSP 292 TR 25–27 Page 3 of 4 Apr 13/2225–70–00

TEMPORARY

REVISION

TEMPORARY

REVISION EFF: Aircraft Serial Nos. 1001 to 1055, 1058 to 1060, 1062 to 1079, 1081 to 1108, 1110 to 1112, and 1123 B. Water Door Mechanism − Functional Test WARNING: INADVERTENT OPERATION OF WATER DOORS MAY CAUSE SERIOUS INJURY. ENSURE THAT ADEQUATE PRECAUTIONS HAVE BEEN TAKEN TO PREVENT OPERATION BEFORE APPROACHING DOORS.

(1) Close the following circuit breakers:

− EMER HYD − WATER SYSTEM − HYD ISOL VALVE − WARNING LIGHTS WATER.

(2) Set the following switches:

− ELECT MASTER to ON − HYD MASTER to ON − WATER DOORS to ARMED.

(3) Set SELECT switch to TRAIN.

(4) Press WATER DROP button and check that right water door opens immediately and operates smoothly, without chattering.

(5) Release WATER DROP button. Check that time from release of button until JACK READY light comes on is 15 +2 seconds.

(6) Press WATER DROP button and check that left door opens immediately and operates smoothly, without chattering.

(7) Release WATER DROP button and check that time from release of button until JACK READY light comes on is 15 +2 seconds.

(8) Check doors for correct locking and for match with outer skin.

(9) Set SELECT switch to BOTH.

(10) Press WATER DROP button, then release. Check that response is immediate and that both doors open smoothly. Check that doors close within 5 +1 seconds, and that there is no appreciable lag between doors when opening or closing.

(11) Check door and supporting structure for deformation or cracking.

CL-215 MAINTENANCE MANUAL PSP 292 TR 25–27 Page 4 of 4 Apr 13/2225–70–00

TEMPORARY

REVISION

TEMPORARY

REVISION EFF: Aircraft Serial Nos. 1001 to 1055, 1058 to 1060, 1062 to 1079, 1081 to 1108, 1110 to 1112, and 1123

(12) Check hydraulic components, t ubing and flexible hoses for leakage.

(13) Check flexible hoses for stretching or pinching during actuator operation.

(14) Set water system switches to OFF.

C. Electrical System − Operational Test Refer to Figure 501.

(1) Apply external DC power. Refer to Chapter 24.

(2) Close INTERNAL LIGHTS WARN TEST circuit breaker.

(3) Press test button on centre instrument panel and check that following water system legends are lit:

− DOOR LOCKED (2) − DOOR UNLOCKED (2) − JACK READY (2) − JACK NOT READY (2) − PROBE UP − PROBE DOWN − ARMED.

(4) Holding test button depressed, switch NAV LIGHTS to ON and check that all above lights are dimmed.

NOTE: Ignore lights that are not part of water system.

(5) Open INTERNAL LIGHTS WARN TEST circuit breaker.

(6) Check system operation. Carry out procedur e in sequence from step (1) to step (20), inclusive. Note that steps (5), (10), (12) and (14) have two stages, door closed and door locked.

(7) Remove external DC power. Refer to Chapter 24.

(8) On aircraft Post Mod CL/0076 with Hydraulic Solenoid Electrical Back-EMF protection, using a digital multimeter in diode test mode, measure CR21MA, CR22MA, CR23MA, CR24MA, CR25MA, CR26MA, CR27MA, CR28MA. Confirm the forward-bias reading is approximately 0.67V and reverse-bias reading is open. Refer to PSP 293 or PSP 393.