What it approves
Installation of Trig Avionics TY-96 or TY-97 VHF Communications Radio
What the certificate says
From the PDF’s text layer, without the form’s printed wording. Layout and order may differ; the PDF is the record.
FAA Form 8110-2 (5/14) Page 1 of
Part of the
Signature
Title Peregrine 13000 E. Control Tower RD STE 220 Box K-4 Englewood, CO 80112 2 SA01835WI * See AML for certification basis.
23 * Installation of Trig Avionics TY-96/96A or TY-97/97A VHF Communications Radio. See attached Approved Model List (AML) SA01835WI for data required.
1. The installer must determine whether this design change is compatible with previously approved modifications.
2. If the holder agrees to permit another person to use this certificate to alter a product, the holder must give the other person written evidence of that permission.
See attached Approved Model List (AML) No. SA01835WI for all makes, models and certification basis.
April 11, 2018 April 11, 2018 May 6, 2016 April 17, 2017 Todd Dixon Manager Denver ACO Branch
FAA Form 8110-2 (5/14) Page 2 of
To (Name and address of transferee)
From (Name and address of grantor)
2 SA01835WI
ADs that name this STC · 0
An AD can apply because an STC is installed, or mention one in its text.
Approved models · 704
Every issue · 2
DRS keeps each issue of an STC as its own record, with its own certificate and attachments.
| Date | Status | Files |
|---|---|---|
| April 11, 2018 | Amended, current | CertificateApproved model list |
| April 17, 2017 | Issued, earlier issue | CertificateApproved model list |