What it approves
Relocate the standard loads from Emergency Battery 2 to Emergency Battery 1, and add the VHF Comm 1 and FMS 1 to Emergency Battery 2. Requires installation of a 3-inch Standby-Gyro, per ECR 3962, or equivalent.
What the certificate says
From the PDF’s text layer, without the form’s printed wording. Layout and order may differ; the PDF is the record.
FAA Form 8110-2(10-68) Number SA8123NM-D
This Certificate issued to Learjet Inc.
One Learjet Way Wichita, Kansas 67209 Part 25* of the Federal Aviation Regulations. (For the Certification Basis see T.C.D.S. A10CE)
A10CE Learjet 60
Description of Type Design Change: Relocate the standard loads from Emergency Battery 2 to Emergency Battery 1, and add the VHF Comm 1 and FMS 1 to Emergency Battery 2, in accordance with DAS Approved Master Drawing List No. LJ-1020-TUC, Revision (-), dated May 13, 1998, or later DAS Approved Revision.
Limitations and Conditions: 1) This installation should not be incorporated in any aircraft unless it is determined that the interrelationship between this installation and any previously approved configuration will not introduce any adverse effect upon the airworthiness of the aircraft. 2) If the holder agrees to permit another person to use this certificate to alter the product, the holder shall give the other person written evidence of that permission. 3) This STC requires the installation of a 3-inch Standby-Gyro, per ECR 3962, or equivalent.
Date of application : May 11, 1998
Date of issuance : July 06, 1998
Date reissued : December 23, 2015
Original signed by Keith Johnston
( Signature) Keith Johnston ODA administrator ODA-501508-CE, Learjet Inc.
W i c h i t a , K a n s a s ( Title)
NOTE:
DO NOT DELETE THIS PAGE.
DO NOT ADD ANY DATA TO THIS PAGE.
THIS PAGE IS FOR PAGE NUMBERING PURPOSES, PLEASE DISCARD PRINTED COPY.
ADs that name this STC · 0
An AD can apply because an STC is installed, or mention one in its text.
Approved models · 1
| Make | Model | Data sheet |
|---|---|---|
| Learjet Inc. | Learjet 60 | A10CE |