What it approves
Installation of a medical interior and life support equipment
What the certificate says
From the PDF’s text layer, without the form’s printed wording. Layout and order may differ; the PDF is the record.
FAA Form 8110-2 (5/14) Page 1 of
Part of the
Signature
Title SH664NE Sikorsky Aircraft Corporation 6900 Main Street Stratford, CT 06615 Federal Aviation Regulations.
1. Installation of a medical interior and life support equipment in accordance with Keystone Helicopter Corporation Medevac Installation Drawing List, Report No. IDL 87-5, Rev. C, dated July 20, 1994, and Keystone Helicopter Corporation Installation Instructions BO 105 S Medical Interior Report No. IM 87-5.1 dated January 30, 1989.
2. Keystone Helicopter Corporation Rotorcraft Flight Manual Supplement No. FM 87-5, Rev. 2, dated March 3, 1995, for Eurocopter Deutschland BO-105S is required with this STC.
(See Description of Type Design Change continued on Page 3 of 3)
1. The installer must determine whether this design change is compatible with previously approved modifications.
2. If the holder agrees to permit another person to use this certificate to alter a product, the holder must give the other person written evidence of that permission.
Gaetano Sciortino Manager New York Aircraft Certification Office * See AML No. SH664NE * See AML No. SH664NE October 1, 2011, December 17, 2014 July 5, 1990, July 10, 1991, March 3, 1995 November 15, 1988 June 21, 1989 * See AML No. SH664NE 3
FAA Form 8110-2 (5/14) Page 2 of
To (Name and address of transferee)
From (Name and address of grantor)
3 SH664NE
FAA Form 8110-2 (5/14) Page 3 of
3 Date Reissued: December 17, 2014
Description of Type Design Change (continued):
3. Keystone Helicopter Corporation Rotorcraft Flight Manual Supplement No. FM 87-5.1, no revision, dated March 3, 1995, for Eurocopter Deutschland BO-105LS A-1 is required with this STC.
4. Keystone Helicopter Corporation Rotorcraft Flight Manual Supplement No. FM 87-5.2, no revision, dated March 3, 1995, for Eurocopter Canada BO-105LS A-3 is required with this STC.
----------END---------- SH664NE
ADs that name this STC · 0
An AD can apply because an STC is installed, or mention one in its text.
Approved models · 3
Every issue · 2
DRS keeps each issue of an STC as its own record, with its own certificate and attachments.
| Date | Status | Files |
|---|---|---|
| December 17, 2014 | Reissued, current | CertificateApproved model list |
| October 1, 2011 | Reissued, earlier issue | Certificate |