What it approves
Installation of Outerlink Corporation Air IP system
What the certificate says
From the PDF’s text layer, without the form’s printed wording. Layout and order may differ; the PDF is the record.
FAA 8110-2 (10/24) Page 1 of ___ SR11898NY Sterling Helicopter 1226 River Road Croydon, PA 19021 27 Title 14 Code of Federal Regulations H2SW Bell Textron Canada Limited 206, 206A, 206A-1, 206B, 206B-1, 206L, 206L-1,206L-3, 206L-4, 407
1. The installer must determine whether this design change is compatible with previously approved modifications.
2. If the holder agrees to permit another person to use this certificate to alter a product, the holder must give the other person written evidence of that permission. (see continuation sheet 3) 06/19/2023 02/18/2025 Michael P. Linegang Manager, East Certification Branch (AIR-750) Compliance & Airworthiness Division Aircraft Certification Services (AIR), AVS/FAA 3
1. Installation of Outerlink Corporation Air IP system in accordance with Sterling Helicopter Master Drawing List, Document ST-9951-02, Rev. C, dated November 14, 2025 or later FAA approved revision.
2. Maintenance to be performed according to the Instructions for Continued Airworthiness (ICA) Document Number ST-9951-03, Rev. A, dated June 13, 2025.
02/05/2026
3. A copy of this certificate and the applicable ICA must be maintained as part of the permanent records of the modified aircraft.
4. Aircraft to be operated in accordance with Sterling Helicopter Rotorcraft Flight Manual Supplement (RFMS) document number ST-9951-13, Rev. -, FAA Approved dated February 04, 2025.
5. This STC is applicable to all serial numbers for Bell Textron Model Series 206/407.
Certification Basis:
In accordance with 14 CFR §§ 21.115 and 21.101, and the FAA policy for significant changes per FAA Order 8110.48A, the FAA certification basis for the aircraft listed on this certificate is as follows:
a. The Certification Basis for areas that have not been altered or impacted by this modification remain in accordance with the aircraft's Type Certificate Data Sheets (TCDS) No. H2SW.
b. For parts altered or impacted by this modification since the application reference date of June 19, 2023, the certification basis is established under Part 27 as amended by Amendment 27-30 and is as follows:
27.301(a)(b) [Amdt. 27-0], 27.303 [Amdt. 27-0], 27.305 [Amdt. 27-0], 27.307(a) [Amdt.
27-26], 27.337(a) [Amdt. 27-26], 27.561(a)(b) [Amdt. 27-30], 27.561(b)(3)(i-iv) [Amdt. 27-0],
27.601(a) [Amdt. 27-0], 27.603 [Amdt. 27-16], 27.605(a) [Amdt. 27-16], 27.609 [Amdt. 27-0],
27.610 [Amdt. 27-21], 27.611(a)(b) [Amdt. 27-0], 27.613 [Amdt. 27-26], 27.619 [Amdt. 27-0],
27.625(a) [Amdt. 27-0], 27.1301 [Amdt. 27-0], 27.1309(a)(c) [Amdt. 27-21], 27.1351(a) [Amdt.
27-13], 27.1357(c) [Amdt. 27-13], 27.1365 [Amdt. 27-0], 27.1501(b) [Amdt. 27-14], 27.1529 [Amdt. 27-18], 27.1541(a)(2) [Amdt. 27-0], 27.1581(a)(2) [Amdt. 27-14], 27 Appendix A 27.1 [Amdt. 27-24], 27 Appendix A 27.2 [Amdt. 27-24], 27 Appendix A 27.3 [Amdt. 27-24], 27 Appendix A 27.4 [Amdt. 27-24].
END 3 3 Add Page
ADs that name this STC · 0
An AD can apply because an STC is installed, or mention one in its text.
Approved models · 10
| Make | Model | Data sheet |
|---|---|---|
| Bell Textron Canada Limited | 206 | H2SW |
| Bell Textron Canada Limited | 206A | H2SW |
| Bell Textron Canada Limited | 206A-1 (OH-58A) | H2SW |
| Bell Textron Canada Limited | 206B | H2SW |
| Bell Textron Canada Limited | 206B-1 | H2SW |
| Bell Textron Canada Limited | 206L | H2SW |
| Bell Textron Canada Limited | 206L-1 | H2SW |
| Bell Textron Canada Limited | 206L-3 | H2SW |
| Bell Textron Canada Limited | 206L-4 | H2SW |
| Bell Textron Canada Limited | 407 | H2SW |
Every issue · 2
DRS keeps each issue of an STC as its own record, with its own certificate and attachments.
| Date | Status | Files |
|---|---|---|
| February 5, 2026 | Amended, current | Certificate |
| February 18, 2025 | Issued, earlier issue | Certificate |