- Holder
- Intermountain Turbine Services Inc.
- Revision
- 21
- Revised
- June 9, 2023
- Status
- Current
- Product
- Engine
- Certification basis
- Part 33
- Models
- 13
- Registered
- 51 aircraft
The release keeps the latest revision of each data sheet. Model names are as the data sheet lists them.
On this page
Models · 13
| Model | Also known as | Note |
|---|---|---|
| LTS101-700D-2 | ||
| LTS101-600A-3 | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-750C-1 | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-650C-3A | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-850B-2 | ||
| LTS101-600A-2 | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-650C-3 | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-750B-2 | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-650B-1 | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-650B-1A | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-750B-1 | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-600A-3A | Formerly Textron-Lycoming, then AlliedSignal | |
| LTS101-650C-2 | Formerly Textron-Lycoming, then AlliedSignal |
Airworthiness directives · 25
ADs whose products are models on this data sheet, matched by model and maker.
AD 2011-23-13Power turbine governors (PTG)AD 2011-08-06Power turbine rotorsAD 2009-24-12Gas generator
See all 25 ADsRegistered aircraft
Registry models that point at this data sheet, with their registered aircraft.
Lycoming LTS-101 series29 registered aircraftHoneywell LTS101-700D-28 registered aircraftHoneywell LTS101-600A3A5 registered aircraft
See all 16 registry modelsSTCs approved under this data sheet · 1
What the data sheet says
From the PDF’s text layer, line by line: tables lose their columns. The PDF is the record.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
TYPE CERTIFICATE DATA SHEET NO. E5NE
Engines of models described herein conforming with this data sheet (which is part of Type Certificate No. E5NE) and other
approved data on file with the Federal Aviation Administration (FAA), meet the minimum standards for use in certificated
aircraft in accordance with pertinent aircraft data sheets and applicable portions of the Federal Aviation Regulations, provided
they are installed, operated, and maintained as prescribed by the approved manufacturer's manuals and other approved
instructions.
TYPE CERTIFICATE (TC) HOLDER: Intermountain Turbine Services, Inc.
270 South 1060 West
Lindon, UT 84042
Type Certificate Holder Record: Honeywell International, Inc. transferred TC E5NE to
Intermountain Turbine Services, Inc. on June 9, 2023.
TYPE CERTIFICATE HOLDER RECORD: The TC No. E5NE was originally issued to Avco Lycoming Engine Group,
Stratford Division, Stratford, Connecticut. The TC was endorsed for transfer on July 20, 1982, and was reissued to Avco
Lycoming Engine Group, Williamsport Division, Williamsport, Pennsylvania on August 16, 1982. The TC was again endorsed
for transfer on January 29, 1987, and was reissued to Avco Lycoming Textron, Stratford Division, Stratford, Connecticut, on
February 27, 1987. The TC was endorsed for a change in the holder's name on October 21, 1987, and was reissued to Textron
Lycoming, Stratford Division, on October 28, 1987. The TC was endorsed for a change in the holder's name on January 27,
1995, and was reissued to AlliedSignal Inc. on January 31, 1995. The TC was reissued for a change in the holder’s name to
Honeywell International Inc. on December 14, 1999. Honeywell International, Inc. transferred ownership of TC No. E5NE to
Intermountain Turbine Services, Inc. on June 9, 2023.
E5NE
Revision 21
Intermountain Turbine
Services, Inc.
LTS101-600A-2
LTS101-600A-3
LTS101-600A-3A
LTS101-650B-1
LTS101-650B-1A
LTS101-650C-2
LTS101-650C-3
LTS101-650C-3A
LTS101-700D-2
LTS101-750B-1
LTS101-750B-2
LTS101-750C-1
LTS101-850B-2
June 9, 2023
PAGE 1 2 3 4 5 6 7 8 9 10 11 12
REV. 21 17 18 19 21 17 17 20 20 20 21 21
LEGEND: "- -" INDICATES "SAME AS PRECEDING MODEL"
"---" INDICATES "DOES NOT APPLY"
NOTICE: ALL PAGES ARE REFORMATTED. SIGNIFICANT CHANGES ARE
BLACK-LINED.
E5NE Page 2 of 13
I. MODELS: LTS101 -600A-2 -600A-3 -650B-1 -650B-1A -650C-2 -650C-3
-650C-3A
TYPE
RATINGS (See NOTE 1)
Maximum Continuous
at sea level, hp.
Takeoff (5 minutes)
at sea level, hp.
30 minute OEI
Rating at sea level hp.
2 1/2 minute OEI
Rating at sea level hp.
Axial – centrifugal flow, free turbine, turboshaft. Single stage axial and single stage
centrifugal compressor. Reverse flow annular combustor. Single stage gas generator
turbine. Single stage power turbine.
590
615
---
---
- -
- -
---
---
550(1)
550(2)
592(3)
592(4)
550
600
600
650
592
628
650
675
598
630
- -
- -
I. MODELS: LTS101 -750B-1 -750B-2 -750C-1 -600A-3A -700D-2 -850B-2
TYPE
RATINGS (See NOTE 1)
Maximum Continuous
at sea level, hp.
Takeoff (5 minutes)
at sea level, hp.
30 minute OEI
at sea level hp.
2 1/2 minute OEI
at sea level hp.
Axial – centrifugal flow, free turbine, turboshaft. Single stage axial and single stage
centrifugal compressor. Reverse flow annular combustor. Single stage gas generator
turbine. Single stage power turbine.
550(5)
550(6)
694(7)
727(8)
658
690
708
742
653
684
702
735
625
650
---
---
650
732
---
---
746
780
807
838
(1) Available to ambient temperature of 72oF
(22oC) (5) Available to ambient temperature of 91oF (33oC)
(2) Available to ambient temperature of 84oF (29oC) (6) Available to ambient temperature of 106oF
(41oC)
(3) Available to ambient temperature of 78oF
(25oC)
(4) Available to ambient temperature of 91oF
(33oC)
(7) For engines in compliance with SB LTS 101B-72-00-0161,
NOTE 1 applies. 592 Hp available to ambient temperature of
100oF (38oC) for LTS101-750B-1 engines not in compliance
with SB No. LTS 101B-72-00-0161.
(8) For engines in compliance with SB LTS101B-72-00-0161,
NOTE 1, applies. 592 Hp available to ambient temperature of
115oF (46oC) for LTS101-750B-1 engines not in compliance
with SB No. LTS101B-72-00-0161.
E5NE Page 3 of 13
I. MODELS: LTS101 -600A-2 -600A-3 -650B-1 -650B-1A -650C-2 -650C-3
-650C-3A
REDUCTION GEAR RATIO
0.1612
- -
0.1654
0.1612
0.2632
- - (Output Shaft Speed to
Power Turbine Speed)
FUEL (See NOTE 2 and NOTE ASTM D1655 Jet - - - - - - - - - -
16) A, A1, & B,
MIL-DTL-5624
Grades JP-4, JP-
5, and JP-8 or
equivalent
OIL (See NOTE 3) MIL-PRF-7808
MIL-PRF-23699
- - - - - - - - - -
PRINCIPAL DIMENSIONS
Length, in. nominal 30.93 31.56 31.05 30.93 31.21 31.21(-3)
31.31(-3A)
Height, in. nominal 23.64 24.80 25.36 - - 19.45 - -
Width, in. nominal 19.37 - - 18.52 - - 22.60 - -
WEIGHT (Dry), lb.
253
265
281
253
240.3
Maximum (includes essential 240.3(-3)
engine accessories but 243(-3A)
excludes starter-generator)
C.G. LOCATION (dry weight)
Aft of engine centerline of lower 5.610 - - 5.671 5.820 8.11 8.11(-3)
mount pads, in. 7.906(-3A)
Below engine centerline, in. 1.880 - - 1.812 1.720 0.641 0.641(-3)
0.598(-3A)
Left of engine centerline looking 0.150 - - 0.072 0.080 0.240 0.240(-3)
Aft, in. 0.314(-3A)
E5NE Page 4 of 13
I. MODELS: LTS101 -750B-1 -750B-2 -750C-1 -600A-3A -700D-2 -850B-2
REDUCTION GEAR RATIO
0.1654
- -
0.2632
0.1612
0.1654
- - (Output Shaft Speed to Power
Turbine Speed)
FUEL (See NOTE 2 and NOTE ASTM D1655 Jet - - - - - - - - - -
16) A, A-1, & B,
MIL-DTL-5624
Grades JP-4, JP-5,
and JP-8 or
equivalent
OIL (See NOTE 3) MIL-PRF-7808
MIL-PRF-23699
- - - - - - - - - -
PRINCIPAL DIMENSIONS
Length, in. nominal 31.05 32.36 31.31 31.56 - - 31.05
Height, in. nominal 25.36 24.68 20.15 24.80 - - 25.36
Width, in. nominal 18.52 19.86 22.60 19.37 - - 18.52
WEIGHT (Dry), lb.
295
273
244
265
279*
283 Maximum (includes essential
engine accessories but
excludes starter-generator)
C.G. LOCATION (dry weight)
Aft of engine centerline of lower 5.542 3.545 7.767 5.610 - - 3.545
mount pads, in.
Below engine centerline, in. 1.861 1.567 0.559 1.880 - - 1.567
Left of engine centerline
looking aft, in. -0.071 0.075 0.303 0.150 - - 0.075
* For -700D-2, dry weight does not include airframe-mounted electronic overspeed controller of 2.7 lbs.
E5NE Page 5 of 13
CERTIFICATION BASIS 14 CFR part 33 effective February 1, 1965, as amended by 33-1, 33-2, 33-3, 33-4, and 33-5.
MODEL APPLICATION
DATE
TYPE CERTIFICATE
ISSUED/AMENDED
LTS101-600A APR 11, 1974 OCT 24, 1975
LTS101-600B SEP 18, 1974 OCT 24, 1975
LTS101-650A APR 11, 1974 OCT 24, 1975
LTS101-650C APR 05, 1974 OCT 24, 1975
LTS101-600A-1 OCT 15, 1975 OCT 24, 1975
LTS101-600B-3 OCT 15, 1975 OCT 24, 1975
LTS101-650A-1 OCT 15, 1975 OCT 24, 1975
LTS101-600A-2 JUL 21, 1977 NOV 30, 1977
LTS101-600A-1 CANCELED NOV 30, 1977
LTS101-600B-3 CANCELED NOV 30, 1977
LTS101-650A-1 CANCELED NOV 30, 1977
LTS101-650A-2 OCT 25, 1976 FEB 24, 1978
LTS101-650C-2 OCT 25, 1976 FEB 24, 1978
LTS101-650A CANCELED MAR 22, 1978
LTS101-650B-1A FEB 08, 1979 FEB 15, 1979
LTS101-650C CANCELED MAR 01, 1979
LTS101-650C-3 MAY 08, 1980 JUN 10, 1980
LTS101-750A-1 DEC 03, 1980 APR 24, 1981
LTS101-650B-1 JAN 22, 1981 JUN 03, 1981
LTS101-750C-1 JAN 22, 1981 AUG 07, 1981
LTS101-650C-3A SEP 08, 1983 JUL 13, 1984
LTS101-600A-3 MAR 19, 1984 JUL 13, 1984
LTS101-750A-3 JAN 04, 1983 SEP 21, 1984
LTS101-750B-2 FEB 14, 1985 NOV 08, 1985
LTS101-750B-1 MAR 31, 1983 JUN 17, 1986
LTS101-600A CANCELED APR 20, 1987
LTS101-600B CANCELED APR 20, 1987
LTS101-650A-2 CANCELED APR 20, 1987
LTS101-750A-1 CANCELED FEB 17, 1988
LTS101-750A-3 CANCELED FEB 17, 1988
LTS101-600A-3A MAR 16, 1999 JUL 21, 1999
LTS101-700D-2 JUN 30, 1999 FEB 13, 2004
LTS101-850B-2 DEC 13, 2002 FEB 13, 2004
PRODUCTION BASIS NONE
NOTE 1. Engine ratings are based on calibrated stand performance under the following conditions:
Static sea level standard conditions at 59oF and 29.92 in. Hg.
No air bleed, no duct losses, no external power extraction.
Exhaust configuration as specified in the applicable engine Installation Instructions or
Manual.
NOTE 2. Engines will operate satisfactorily with fuel contaminated to the levels specified in the applicable
engine Installation Instructions or Manual provided the fuel is introduced to the engine in accordance
with the installation requirements.
NOTE 3. Mixing of these oil types is prohibited. See Engine Maintenance Manual for approved brands by
type.
NOTES
E5NE Page 6 of 13
NOTE 4. Maximum permissible gas generator operating speeds (r.p.m.):
I. MODELS: LTS101 -600A-2 -600A-3 -650B-1 -650B-1A -650C-2 -650C-3
-650C-3A
Transient
2-1/2 Minute OEI
30 Minute OEI
Takeoff
Maximum Continuous
5 Minute Part Power
50,548 50,787(1) 50,548 - - - - - -
--- --- 50,548 50,169 50,548 - -
--- --- 50,169 49,255 50,169 - -
49,638 49,830(1) 49,638 49,255 49,638 - -
49,159 49,255(1) 49,159 48,394 49,159 - -
--- --- 49,159 --- 49,159 - -
(1) Applicable only if Service Bulletin No. LT101-72-50-0126 and LT101-72-50-0157 are incorporated. For all other engines,
the limits are the same as the –600A-2.
I. MODELS: LTS101 -750B-1 -750B-2 -750C-1 -600A-3A -700D-2 -850B-2
Transient
2-1/2 Minute OEI
30 Minute OEI
Takeoff
Maximum Continuous
5 Minute Part Power
50,787 - - - - - - 51,313 52,178
50,787 - - - - --- --- 51,938
50,169 50,165 - - --- --- 51,699
49,830 - - - - - - 51,026 51,029
49,255 - - - - - - 50,164 50,455
49,255 - - - - --- --- ---
NOTE 5. Maximum permissible power turbine output shaft torque (ft.-lb.):
I. MODELS: LTS101 -600A-2 -600A-3 -650B-1 -650B-1A -650C-2 -650C-3
-650C-3A
Transient 594 - - 649 - - 419 - -
2-1/2 Minute OEI --- --- 594 - - 383 - -
30 Minute OEI --- --- 594 541 369 - -
Takeoff 541 - - 519 541 357 - -
Maximum Continuous 519 - - - - - - 335 - -
5 Minute Part Power --- --- 165 --- 335 - -
No Load (Autorotation) 0 - - - - - - - - - -
I. MODELS: LTS101 -750B-1 -750B-2 -750C-1 -600A-3A -700D-2 -850B-2
Transient
2-1/2 Minute OEI
30 Minute OEI
Takeoff
Maximum Continuous
5 Minute Part Power
No Load (Autorotation)
725 - - 480 641** 725** - -
643 - - 417 --- --- 643
614 - - 397 --- --- 614
597 - - 387 583 618 597
567 - - 367 561 567 ---
165* - - 343 --- --- ---
0 - - - - - - - - - -
* Approved for continuous operation at out put shaft speed up to 6,180 r.p.m. and output shaft torque up to 377 ft.-lb.
** Time limit: 30 seconds above Takeoff torque limit.
E5NE Page 7 of 13
NOTE 6. Maximum permissible output shaft speeds (r.p.m.):
I. MODELS: LTS101 -600A-2 -600A-3 -650B-1 -650B-1A -650C-2 -650C-3
-650C-3A
Transient
2-1/2 Minute OEI
30 Minute OEI
Takeoff
Maximum Continuous
5 Minute Part Power
No Load (Autorotation)
6,300 - - 6,365 6,300 9,784 - -
--- --- 6,120 6,085 9,545 - -
--- --- 6,120 6,085 9,545 - -
6,085 - - 6,120 6,085 9,545 - -
6,085 - - 6,120 6,085 9,545 - -
--- --- 6,365 --- 9,930 - -
6,300 - - 6,365 6,300 9,930 - -
Transient
2-1/2 Minute OEI
30 Minute OEI
Takeoff
Maximum Continuous
5 Minute Part Power
No Load (Autorotation)
*Time limit 12 seconds above 6,460 r.p.m.
**Approved for continuous operation at output shaft speed up to 6,180 r.p.m. and output shaft torque up to 377 ft.-lb.
***Time Limit: 5 seconds above 6,780 r.p.m.
NOTE 7. Maximum permissible temperatures:
Measured gas temperature oF (oC) as measured by thermocouples mounted in the combustor housing:
LTS101 -600A-2 -600A-3 -650B-1 -650B-1A -650C-2 -650C-3
-650C-3A
Starting
Transient
2-1/2 Minute OEI
30 Minute OEI
Takeoff
Maximum Continuous
5 Minute Part Power
1650* (899) - - ** - - * - - - - - -
1550* (843) 1557 (847)** 1550 (843) - - - - - -
--- --- 1530 (832) 1485 (807) 1530 (832) - -
--- --- 1464 (796) 1420 (771) 1464 (796) - -
1440*** (782) 1447***
(786)(1)
1440***
(782)
1420***
(771)
1440 (782) - -
1405 (763) 1409 (765)(1) 1405 (763) 1360 (738) 1405 (763) - -
--- --- 1405 (763) --- 1405 (763) - -
(1) Applicable only if Service Bulletin No. LT 101-72-50-0126 and LT 101-72-50-0157 are incorporated. For all other -600A-3
engines, the maximum MGT at the takeoff rating shall be 1380oF (749oC) and 1355oF(735oC) at the maximum continuous rating.
LTS101 -750B-1 -750B-2 -750C-1 -600A-3A -700D-2 -850B-2
Starting
Transient
2-1/2 Minute OEI
30 Minute OEI
Takeoff
Maximum Continuous
5 Minute Part Power
1650** (899) - - - - - - 1731***(944) 1679**(915)
1557** (847) - - - - - - 1731***(944) 1679**(915)
1537 (836) 1512 (822) - - --- --- 1637 (892)
1472 (800) 1471 (799) - - --- --- 1608 (875)
1447*** (786) 1447 (786) - - - - *** 1694***(923) 1559 (848)
1409 (765) 1409 (765) - - - - 1635 (890) 1523 (828)
1405 (763) - - - - --- --- ---
I. MODELS: LTS101 -750B-1 -750B-2 -750C-1 -600A-3A -700D-2 -850B-2
6,580* - - 9,930 7,200 7,404*** 7,380***
6,140 - - 9,545 --- --- 6,780
6,140 - - 9,545 --- --- 6,780
6,140 - - 9,545 6,780 - - - -
6,140 - - 9,545 6,780 - - - -
6,460** - - 9,930 --- --- ---
6,460 - - 9,930 6,780 - - - -
E5NE Page 8 of 13
NOTE 7. Continued
*Time limit 12 seconds above 1530oF (832oC).
**Time limit 12 seconds above 1537oF (836oC) (-750B-1, -600A-3, and –600A-3A), and 12 seconds above 1512oF (822oC)
(-750B-2, and -750C-1), and 12 seconds above 16370F (892oC) (-850B-2).
***For the LTS101-600A-2, -600A-3, and -600A-3A engine models, the transient measured exhaust gas temperature must not
exceed the takeoff measured exhaust gas temperature for more than 22 seconds. For the LTS101-650B-1, -650B-1A, and
-750B-1 engine models, the transient measured exhaust gas temperature must not exceed the takeoff measured exhaust gas
temperature for more than 22 seconds and never exceed 1499oF (815oC) at any time during normal takeoff operation. For the
LTS101-700D-2, the starting and transient measured gas temperatures must not exceed the takeoff measured gas temperature for
more than 30 seconds.
The transient limits are not to be used for increased power operation during normal takeoff.
Maximum permissible component temperatures:
LTS101 -600A-2 -600A-3 -650B-1 -650B-1A -650C-2 -650C-3
-650C-3A
Zone Temperature (oF):
Gas Generator Speed Control 250 - - - - - - - - - -
Ignition Exciter Box 250 - - - - - - - - - -
Inlet Flow Actuator 410 - - - - - - - - - -
Thermocouple Harness --- --- --- --- --- ---
Electrical Harness --- --- --- --- --- ---
Power Turbine Governor 280 - - - - - - - - - -
Thermocouple Junction Block 450 - - - - - - - - - -
Anti-Icing Valve 450 - - - - - - - - - -
Torque Limiter --- --- --- --- --- ---
Fuel Manifold --- --- --- --- 350 - -
Power Turbine Overspeed Trip 250 - - 160 250 - - 160
(1)
Fuel Metering Unit --- --- --- --- --- ---
EFCS Alternator --- --- --- --- --- ---
Electronic Control Computer --- --- --- --- --- ---
MGT Transient Compensator --- --- --- --- --- ---
LTS101 -750B-1 -750B-2 -750C-1 -600A-3A -700D-2 -850B-2
Gas Generator Speed Control 250 - - - - - - - - - -
Ignition Exciter Box 250 - - - - - - - - - -
Inlet Flow Actuator 410 - - - - - - - - - -
Thermocouple Harness --- --- --- --- --- ---
Electrical Harness --- --- --- --- --- ---
Power Turbine Governor 280 - - - - - - - - - -
Thermocouple Junction Block 450 - - - - - - - - - -
Anti-Icing Valve --- 450 - - - - - - - -
Torque Limiter --- --- --- --- --- ---
Fuel Manifold --- --- --- --- --- ---
Power Turbine Overspeed Trip 160 250 160 250 160 160
(1)
Fuel Metering Unit --- --- --- --- --- ---
EFCS Alternator --- --- --- --- --- ---
Electronic Control Computer --- --- --- --- --- ---
MGT Transient Compensator --- 160 - - --- --- ---
E5NE Page 9 of 13
(1) Zone temperature limit of 250oF is for mechanical power turbine overspeed trip system mounted on the accessory pad
marked “Alternator”. All other engine models utilize an electronic overspeed system with a 160oF limit for the airframe-
mounted box.
NOTE 8. Fuel pressure limits and oil pressure and temperature limits:
Fuel pressure limits for the LTS101-600A-2, and -600A-3 engine models are 15 p.s.i.a. minimum and
45 p.s.i.a. maximum. For all other engine models, the fuel system provides suction lift capability
without any external assistance. See the applicable engine Installation Instructions for further details.
Oil pressure and temperature (as measured by engine oil temperature bulb located at oil filter
discharge) limits:
Engine Models Specified Range Condition
Oil pressure
during operation
LTS101-650B-1A 80-100 psig Maximum continuous power
LTS101-600A-2, -650B-1, -650C-2/C-3/
C-3A, -750B-1, -750C-1, -700D-2,
-850B-2
80-100 psig
Max. continuous and above with oil
temperature greater than 150oF
(65oC)
LTS101-600A-3, -600A-3A, -750B-2 90-100 psig
Minimum oil pressure LTS101-600A-2 and -650B-1A 20 psig Flight idle and below
LTS101-600A-3, -600A-3A, -650C-2/C-
3/C-3A, -750B-2, -750C-1, -700D-2
20 psig Flight idle, oil inlet temperature
greater than 50oF (10oC)
LTS101-650B-1, -750B-1, -850B-2 40 psig Flight idle, oil inlet temperature
greater than 50oF (10oC)
LTS101-600A-3, -600A-3A, -650B-1,
-650C-2/C-3/C-3A, -750B-1/B-2,
-750C-1, -700D-2, -850B-2
50 psig Flight idle, oil inlet temperature at
or below 50oF (10oC)
Maximum transient
oil pressure (cold oil)
LTS101-600A-2, -650B-1A 200 psig Starting at ambient temperature less
than -20oF (-29oC) for a duration
not to exceed 2.5 minutes
LTS101-600A-3, -600A-3A, -650B-1,
-650C-2/C -3/C-3A, -750B-1/B-2,
-750C-1, -700D-2, -850B-2
350 psig (spikes)
120 psig
During oil warm up from 50oF
(10oC) to 150oF (65oC)
Maximum oil inlet
temperature
LTS101-650C-2/C-3/C-3A, -750C-1 220oF (105oC) Ambient temperature less than
100oF (38oC)
LTS101-600A-2, -600A-3, -600A-3A,
-650B-1*, -650B-1A, -750B-1/B-2,
-700D-2, -850B-2
210oF (99oC) Ambient temperature less than
100oF (38oC)
LTS101-600A-2, -600A-3, -600A-3A,
-650B-1*, -650B-1A, -650C-2/C-3/C-3A,
-750B-1/B-2, -750C-1, -700D-2, -850B-2
230oF** (110oC) Ambient temperature at or above
100oF (38oC)
*50oF (10oC) minimum oil temperature for operation above ground idle.
150oF (65oC) minimum oil temperature during sustained steady state power.
**Oil temperature limit also applies for one engine inoperative (OEI) conditions.
E5NE Page 10 of 13
NOTE 9. Accessory drive provisions:
LTS101
Description
-600A-2 -600A-3 -650B-1 -650B-1A -650C-2 -650C-3
-650C-3A
Starter Generator Pad Type
Rotation (viewing pad)
Gear Ratio(1)
Maximum Torque (in-lb)
Starting
Transient
Maximum continuous
Accessory Pad Type
Rotation (viewing pad)
Gear Ratio(2)
Maximum Torque (in-lb)
Starting
Maximum continuous
Spare Pad Type
Rotation (viewing pad)
Gear Ratio(2)
Maximum Torque (in-lb)
Starting
Maximum continuous
AND20001
Modified (3)
- - - - - - - - - -
CW - - - - - - - - - -
.2512 - - - - - - - - - -
500
150(5)
46(6)
- -
- -
71(6)
- -
- -
- -
- -
- -
- -
- -
- -
- -
---
- -
- -
AND20002
Modified (3)
--- AND20002
Modified (3)
- - - - - -
CW --- CW - - - - - -
0.3265 --- 0.3265 - - 0.3406 - -
---
75
---
---
---
75
---
- -
---
- -
---
- -
AND20000
Modified(3)
(4)
- - --- AND20000
Modified(3)
(4)
--- ---
CCW --- --- CCW --- ---
0.5375 --- --- 0.5375 --- ---
---
20
---
- -
---
---
---
11
---
---
---
---
LTS101
Description
-750B-1 -750B-2 -750C-1 -600A-3A -700D-2 -850B-2
Starter Generator Pad Type
Rotation (viewing pad)
Gear Ratio(1)
Maximum Torque (in-lb)
Starting
Transient
Maximum continuous
Maximum applied torque
Accessory Pad Type
Rotation (viewing pad)
Gear Ratio(2)
Maximum Torque (in-lb)
Starting
Maximum continuous
Spare Pad Type
Rotation (viewing pad)
Gear Ratio(2)
Maximum Torque (in-lb)
Starting
Maximum continuous
AND20001
Modified (3)
- - - - - - - - - -
CW - - - - - - - - - -
0.2512 - - - - - - - - - -
500
150(5)
71(6)
- -
- -
- -
- -
- -
- -
580
- -
- -
- -
- -
- -
- -
- -
- -
--- --- --- 1,100 in-lb(7) - - - -
--- --- AND20002
Modified (3)
--- --- ---
--- --- CW --- --- ---
--- --- 0.3406 --- --- ---
---
---
---
---
---
75
---
---
---
---
---
---
--- --- --- AND20000
Modified
(3)(4)
--- ---
--- --- --- CCW --- ---
--- --- --- 0.5375 --- ---
---
---
---
---
---
---
---
20
---
---
---
---
E5NE Page 11 of 13
NOTE 9. Continued
(1) With respect to gas generator.
(2) With respect to power turbine.
(3) Limit pad speed and maximum loads modified. See the applicable engine Installation Instructions or Manual for
further details.
(4) Pad pilot diameter modified to 1.622 in. Pad spline pitch diameter modified to .4583 in.
(5) To be used in generating mode only, with a time limit of 30 seconds.
(6) If the starter generator rating is more than 150 amps., the continuous electric load must be limited to 150
amps when the gas generator is less than 43,100 r.p.m.
(7) Applied torque at the starter pad shall not exceed the value stated under any operating or failure condition.
CW - Clockwise, CCW - Counterclockwise
NOTE 10 The LTS101-600A-2 engine model meets the FAA requirements for operation in icing conditions
provided that the induction system design conforms to Kit Number 4-201-080-01, and a
minimum of 37,080 r.p.m. gas producer speed is maintained.
The LTS101-600A-3, -600A-3A, -750C-1, and -700D-2 engine models meet the FAA requirements
for operation in icing conditions provided that the induction system design conforms to Kit Number
4-201-080-01, and a minimum of 38,294 r.p.m gas generator speed is maintained.
The LTS101-650C-2, -650C-3, and -650C-3A engine models meet the FAA requirements for
operation in icing conditions provided that a minimum of 37,080 r.p.m. gas producer speed is
maintained.
The LTS101-650B-1A engine model meets the FAA requirements for operation in icing conditions
provided that the induction system design conforms to Figure 6.8 of Installation Instructions
101.14.50, and a minimum bypass flow of 29% at an inlet referred flow rate of 4.8 lb./sec. is
maintained.
The LTS101-650B-1 engine model meets the FAA requirements for operation in icing conditions
provided that the induction system design conforms to Figure 18 of Installation Instructions
101.14.36.
The LTS101-750B-1 engine model meets the FAA requirements of § 33.68, Amendment 10, for
operation in icing conditions provided that the induction system design conforms to Figure 18 of
Installation Instructions 83.101.11.
The LTS101-750B-2 engine model meet the FAA requirements of § 33.68, Amendment 10, for
operation in icing conditions provided that the induction system design conforms to Figure 19 or
Figure 19A of Installation Manual IM-8020. A minimum bypass flow of 29% at an inlet referred flow
rate of 5.2 lb./sec. is required when equipped with the induction system design as depicted by Figure
19 of the Installation Manual.
The LTS101-850B-2 engine model meets the FAA requirements of § 33.68, Amendment 10, for
operation in icing conditions provided that the induction system design conforms to Attachment 1 of
Installation Manual IM-8022, Revision A, or later FAA approved revisions, and a maximum gas
generator speed of 104.1 percent (all engines operating) and 106.1 percent (OEI) is not exceeded.
E5NE Page 12 of 13
NOTE 11. These engines have not been tested to evaluate the effects of bird and ice ball ingestion. The bird and
ice ball ingestion characteristics of the airframe air inlet and engine combination are to be evaluated
prior to approval of the engine installation.
NOTE 12. Deleted (Revision 19)
NOTE 13. Maximum permissible air bleed extraction is 5% of inlet airflow at the designed customer bleed port
at standard sea level static conditions.
NOTE 14. Certain engine parts are life limited. The limits are listed in FAA approved Service Bulletin Number
LT 101-71-00-0002.
NOTE 15. Engine starter torque and speed requirements are specified in the applicable engine Installation
Instructions or Manual.
NOTE 16. Approved type fuels and fuel additives are specified in the applicable engine Installation Instructions
or Manual or LTS101 Operating Instruction, document 21-11045.
The text continues in the data sheet PDF and in this page’s Markdown copy.