AD 2011-03-09

Airworthiness directive · Ignition · Boeing MD-90-30

Effective
March 14, 2011
Published
February 7, 2011 · 76 FR 6535–6536
Issued
January 26, 2011
Model
MD-90-30
Data sheet
TCDSA6WE
Registered aircraft
5 matched by model
Product
Aircraft · Large airplane
ATA chapter
74 · Ignition
Amendment
39-16593
Docket
FAA-2010-1043
Project
2010-NM-200-AD
Issued as
Final rule

Unofficial copy from the Federal Register XML, document 2011-2428. Only the govinfo PDF is the legal edition. DRS record last changed May 30, 2024.

On this page

Summary

We are adopting a new airworthiness directive (AD) for the products listed above. This AD requires installing new fire handle shutoff system wiring. This AD was prompted by a possible latent failure in the fire handle shutoff relay circuit due to a lack of separation between engine wires. We are issuing this AD to minimize the possibility of a multiple engine shutdown due to single fire handle activation.

The airworthiness directive

2011-03-09 The Boeing Company: Amendment 39-16593; Docket No. FAA-2010-1043; Directorate Identifier 2010-NM-200-AD.

(a) Effective Date

PDF page 2

(a) This AD is effective March 14, 2011.

(b) Affected ADs

PDF page 2

(b) None.

(c) Applicability

PDF page 2

(c) This AD applies to all The Boeing Company Model MD-90-30 airplanes, certificated in any category.

(d) Subject

PDF page 2

(d) Joint Aircraft System Component (JASC)/Air Transport Association (ATA) of America Code 74, Ignition.

(e) Unsafe Condition

PDF page 2

(e) This AD was prompted by a possible latent failure in the fire handle shutoff relay circuit due to a lack of separation between engine wires. We are proposing this AD to minimize the possibility of a multiple engine shutdown due to single fire handle activation.

(f) Compliance

PDF page 2

(f) Comply with this AD within the compliance times specified, unless already done.

(g) Wire Installation

PDF page 2

(g) Within 4,200 flight hours after the effective date of this AD, install new fire handle shutoff system wiring, in accordance with the Accomplishment Instructions of Boeing Alert Service Bulletin MD90-74A002, dated August 17, 2010.

(h) Alternative Methods of Compliance (AMOCs)

PDF page 2

(h)(1) The Manager, Los Angeles Aircraft Certification Office, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in the Related Information section of this AD.

(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office.

(i) Related Information

PDF page 2

(i) For more information about this AD, contact William S. Bond, Aerospace Engineer, Propulsion Branch, ANM-140L, FAA, Los Angeles Aircraft Certification Office, 3960 Paramount Boulevard, Lakewood, CA 90712-4137; phone: 562-627-5253; fax: 562-627-5210; e-mail: William.Bond@faa.gov.

(j) Material Incorporated by Reference

PDF page 2

(j) You must use Boeing Alert Service Bulletin MD90-74A002, dated August 17, 2010, to do the actions required by this AD, unless the AD specifies otherwise.

(1) The Director of the Federal Register approved the incorporation by reference of Boeing Alert Service Bulletin MD90-74A002, dated August 17, 2010, under 5 U.S.C. 552(a) and 1 CFR part 51.

(2) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, 3855 Lakewood Boulevard, MC D800-0019, Long Beach, California 90846-0001; telephone 206-544-5000, extension 2; fax 206-766-5683; e-mail dse.boecom@boeing.com; Internet https://www.myboeingfleet.com.

(3) You may review copies of the service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington. For information on the availability of this material at the FAA, call 425-227-1221.

(4) You may also review copies of the service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at an NARA facility, call 202-741-6030, or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.

Rule preamble

The FAA’s background, reasoning and cost estimate, published with the AD.

DatesPage 1

This AD is effective March 14, 2011.

The Director of the Federal Register approved the incorporation by reference of a certain publication listed in the AD as of March 14, 2011.

AddressesPage 1

For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, 3855 Lakewood Boulevard, MC D800-0019, Long Beach, California 90846-0001; telephone 206-544-5000, extension 2; fax 206-766-5683; e-mail dse.boecom@boeing.com; Internet https://www.myboeingfleet.com. You may review copies of the referenced service information at the FAA Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington. For information on the availability of this material at the FAA, call 425-227-1221.

For further information contactPage 1

William S. Bond, Aerospace Engineer, Propulsion Branch, ANM-140L, FAA, Los Angeles Aircraft Certification Office, 3960 Paramount Boulevard, Lakewood, CA 90712; phone: 562-627-5253; fax: 562-627-5210; e-mail: William.Bond@faa.gov.

DiscussionPage 1

We issued a notice of proposed rulemaking (NPRM) to amend 14 CFR part 39 to include an airworthiness directive (AD) that would apply to the specified products. That NPRM published in the Federal Register on November 5, 2010 (75 FR 68245). That NPRM proposed to require installing new fire handle shutoff system wiring.

CommentsPage 1

We gave the public the opportunity to participate in developing this AD. We received no comments on the NPRM or on the determination of the cost to the public.

Explanation of Change Made to the ADPage 1

We have revised this AD to identify the legal name of the manufacturer as published in the most recent type certificate data sheet for the affected airplane models.

ConclusionPage 1

We reviewed the relevant data and determined that air safety and the public interest require adopting the AD with the change described previously. We also determined that this change will not increase the economic burden on any operator or increase the scope of the AD.

Costs of CompliancePage 1

We estimate that this AD will affect 25 airplanes of U.S. registry.

We estimate the following costs to comply with this AD:

Estimated Costs
ActionLabor costParts costCost per productCost on U.S. operators
Wiring change8 work-hours × $85 per hour = $680$489$1,169$29,225
Authority for This RulemakingPage 1

Title 49 of the United States Code specifies the FAA's authority to issue rules on aviation safety. Subtitle I, section 106, describes the authority of the FAA Administrator. Subtitle VII: Aviation Programs, describes in more detail the scope of the Agency's authority.

We are issuing this rulemaking under the authority described in subtitle VII, part A, subpart III, section 44701: “General requirements.” Under that section, Congress charges the FAA with promoting safe flight of civil aircraft in air commerce by prescribing regulations for practices, methods, and procedures the Administrator finds necessary for safety in air commerce. This regulation is within the scope of that authority because it addresses an unsafe condition that is likely to exist or develop on products identified in this rulemaking action.

Regulatory findingsPage 1

This AD will not have federalism implications under Executive Order 13132. This AD will not have a substantial direct effect on the States, on the relationship between the national government and the States, or on the distribution of power and responsibilities among the various levels of government.

For the reasons discussed above, I certify that this AD:

(1) Is not a “significant regulatory action” under Executive Order 12866,

(2) Is not a “significant rule” under DOT Regulatory Policies and Procedures (44 FR 11034, February 26, 1979),

(3) Will not affect intrastate aviation in Alaska, and

(4) Will not have a significant economic impact, positive or negative, on a substantial number of small entities under the criteria of the Regulatory Flexibility Act.

Adoption of the AmendmentPage 2

Accordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows:

Adoption of the amendmentPage 2

1. The authority citation for part 39 continues to read as follows:

2. The FAA amends § 39.13 by adding the following new airworthiness directive (AD):

Affected TCDS · 1

The type certificate data sheets for the models this AD names, matched by model and maker.

Registered aircraft · 5

Registered aircraft whose airframe or engine model this AD names. Matched by model only, so check each against the AD’s applicability.

By aircraft maker
  • Mcdonnell Douglas3 aircraft
  • Boeing2 aircraft
By year built
19951999
Registered aircraft by year built: 5 aircraft
19951
19962
19981
19991

By model

Aircraft