AD 47-30-07

Airworthiness directive · Trip-Free Circuit Breaker · Textron Army AT-11

Model
Army AT-11
Data sheet
TCDSA-2-582
Product
Aircraft · Small airplane

Unofficial copy of the text in the FAA’s Dynamic Regulatory System. The FAA’s own copy is the authoritative one. DRS record last changed January 21, 2026.

On this page

The airworthiness directive

47-30-07 BEECH: (Was Mandatory Note 3 of AD-2-582-2.) Applies Only to AT-11 Aircraft Which Are Not Equipped With Generator Circuit Protective Devices.

To be accomplished prior to certification or, if certificated, on next periodic inspection but not later than October 1, 1947.

In accordance with Figure 1 install a 50-ampere trip-free circuit breaker, Spencer Thermostat Co. PLM-50 or equivalent, between the battery terminal of each generator cutout and its respective ammeter shunt. The circuit breakers should be accessible in flight and labeled respectively: "LEFT GEN. CIRCUIT" and "RIGHT GEN. CIRCUIT."

Affected TCDS · 1

The type certificate data sheets for the models this AD names, matched by model and maker.

Registered aircraft

No registered aircraft matched this AD’s modelsForeign aircraft aren’t included, and ADs on propellers and appliances aren’t matched by model.