N11189

Service difficulty reports · 85

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N11189' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JJBA20250119037Elec Connector · looseGALLEY EMERGENCY EXIT SIGN INOPERATIVE. UPON INSPECTION, FOUND LOOSE CONNECTION AT GALLEY EXIT SIGN ABOVE SERVICE DOOR. REPAIRED CONNECTION. OPS CHECK SAT.Jan 14, 2026 · N11189 · Emb EMB145XR · Light System WiringSDR JJBA2025515048Support · corrodedTOILET WASTE VALVE SUPPORT HAS CORRODED HARDWARE. REMOVED 1 AFT RINSE NIPPLE SCREW. REPLACED AND INSTALLED 1 AFT RINSE NIPPLE SCREW. REMOVED 4 AFT WASTE DRAIN VALVE SCREWS. REPLACED AND INSTALLED 4 AFT WASTE DRAIN VALVE SCREWSMay 11, 2025 · N11189 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20250515058Floor Support · corrodedFLOOR SILL ASSEMBLY AT STR 16R FR20 FWD GALLEY CORRODED AROUND N/P HOLE. BLENDED CORROSION ON FLOOR SILL ASSEMBLY AT STR 16R FR20 UNDER FWD GALLEY AT N/P HOLE. PERFORMED REQUIRED 30X DVI ON BLEND REPAIR AT STR 16R FR20. PRE-TREATED AND PRIMED AREA.May 11, 2025 · N11189 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20250421062Door · unsecureRAMP AGENT REPORTS MCD WILL NOT FULLY CLOSE. INSPECTED, AND PERFORMED OPS CHECK OF MCD. OPS CHECK SAT. NO DEFECTS NOTED.Apr 17, 2025 · N11189 · Emb EMB145XR · Passenger/Crew DoorsSDR JJBA20250410038Valve · inoperativeBLEED 1/2 OVER TEMP IN ICING. REMOVED AND REPLACED LOW TEMP AIR THERMOSTAT. OPS CHECK SAT. PERFORMED TI AND AGAIN BLEED 2 ARROW TURN AND WENT INTO RED. NO EICAS MESSAGE WAS GIVEN. REMOVED AND REPLACED BLEED 2 OUTLET TEMP SENSOR. PERFORMED BLOCK 1, 2, AND 3 OPSApr 7, 2025 · N11189 · Emb EMB145XR · Pneumatic Indicating SystemSDR JJBA20241219034Tire · failedAIRCRAFT JARRING AT VR. COMPLIED WITH LANDING GEAR TIRE BUST OR TIRE TREAD FAILURE INSPECTION. NO DAMAGE OR DEFECTS NOTED AT THIS TIME.Dec 16, 2024 · N11189 · Emb EMB145XR · TireSDR JJBA20241101017Inverter · inoperativeSERVICE DOOR EXIT SIGN EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED INVERTER 2. OPS CHECK SAT.Oct 29, 2024 · N11189 · Emb EMB145XR · Emergency LightingSDR JJBA20240624041Display · inoperativeMFD FLICKERING ON/OFF WHEN RADAR TURNED ON AND BURNING ODOR. REMOVED AND REPLACED CAS MFD DISPLAY UNIT WITH NEW. OPS CHECK GOOD. NO SMELL OR ODOR NOTED.Jun 19, 2024 · N11189 · Emb EMB145XR · Central DisplaySDR JJBA20240603060Dau · inoperativeFUEL TRANSFER INOPERATIVE IN FLIGHT. REMOVED AND REPLACED DAU #1. OPS CHECK SAT. PERFORMED A FUEL TRANSFER OPS CHECK. OPS CHECK SAT. NO REPEAT FAULT CODES FOUND. REMOVED AND REPLACED VENTRAL PUMP A. OPS/LEAK CHECK SAT.May 26, 2024 · N11189 · Emb EMB145XR · Aircraft Fuel Distribution SystemSDR JJBA20240328092Light · inoperativeLOWER SERVICE DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LOWER SERVICE DOOR EMERGENCY LIGHT. OPS CHECK SATMar 27, 2024 · N11189 · Emb EMB145XR · Emergency LightingSDR JJBA20240308039Connector · corrodedEMERGENCY CALL LIGHT ALWAYS ON IN THE COCKPIT. INSPECTED FA'S HANDSET CONNECTORS, PERFORMED WIRE CHECKS BETWEEN HANDSETS AND PA AMP AND PERFORMED OPS CHECK. NO DEFECTS NOTED. FOUND CORROSION AT P8100, CLEANED CORROSION AND OPS CHECK GOOD. INSPECTED FA'S HANDSEMar 5, 2024 · N11189 · Emb EMB145XR · Light System WiringSDR JJBA20240115011Lamp · inoperativeWING TO FUSELAGE FRONT FAIRING LH EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT HOUSING. OPS CHECK SAT.Jan 13, 2024 · N11189 · Emb EMB145XR · Emergency LightingSDR JJBA20230703026Lamp · noneLH EMERGENCY EXIT OVERHEAD LIGHT INOP R/R LH EMERGENCY EXIT OVERHEAD LIGHT BULB. OPS CHECK SATJun 28, 2023 · N11189 · Emb EMB145XR · Emergency LightingSDR JJBA20230522017Unknown · unknownMAIN CABIN DOOR HARD TO OPEN/CLOSE. APPLIED DRY LUBRICATION TO MAIN CABIN DOOR HINGE AND DOOR SEAL. OPS CHECK GOOD.May 19, 2023 · N11189 · Emb EMB145XR · DoorsSDR JJBA20230306008None · noneCF3, LH OMEGA BEAM #5 CRACKS SUSPECTED FOUND BTW FRAME 41 AND 42 ON FLOOR STRUCTURE. CF3, LH OMEGA BEAM #5 HAS CRACKS SUSPECTED FOUND AT FRAME 41 AND 42 ON FLOOR STRUCTURE. 1 CRACK FOUND AT FR41. BEAM REPAIRED WITH A DOUBLERFeb 27, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230306007None · noneCF3, LH OMEGA BEAM #6 CRACK SUSPECTED FOUND AT FRAME 51 ON FLOOR STRUCTURE. CF3, LH OMEGA BEAM #6 CRACK FOUND AT FRAME 51 ON FLOOR STRUCTURE. BEAM REPAIRED WITH A DOUBLER.Feb 27, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230306005None · noneCF2, CORROSION AND (3X) SUSPECTED CRACKS FOUND ON LH OMEGA BEAM #2 FLOOR STRUCTURE BETWEEN FR 24-30. CF2, CORROSION (LEVEL 1) AND 3 CRACKS FOUND ON LH OMEGA BEAM #2 FLOOR STRUCTURE BTW FR 24-30. BEAM IS REPAIRED WITH 3 DOUBLERSFeb 27, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230309013None · noneCORROSION ON REAR FUSE 2 LOWER SKIN, BTW FR 80-81 AND BTW STR 19L-21L. CORROSION ON REAR FUSE 2 LOWER SKIN BTW FR 80-81 AND BTW STR 19L-21L. SKIN IS REPAIRED WITH A DOUBLER.Feb 26, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230309011None · noneAT REAR FUSE 1 EXT, RADIO ALT ANTENNA NO 2 AFT LOWER DOUBLER CORRODED ON BELLY SKIN BTW FR 68-69. AT REAR FUSE 1 EXT, RADIO ALT ANTENNA NO 2 AFT LOWER DOUBLER CORRODED ON BELLY SKIN BTW FR 68-69, SKIN REPAIRED WITH A DOUBLERFeb 26, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230309009None · noneCORROSION FOUND ON L GUSSET IN TOILET AREA BTW FR 59-61. CF4, CORROSION FOUND ON LH GUSSET IN TOILET AREA BTW FR 59-61. AFTER INVESTIGATION, CORROSION FOUND ON OMEGA BEAM AT FR 59 & 61. BEAM REPAIRED WITH 2 DOUBLERSFeb 26, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230306006None · noneCF2, CORROSION AND (3X) SUSPECTED CRACKS FOUND ON LH OMEGA BEAM #2 FLOOR STRUCTURE BETWEEN FR 29-36. CF2, CORROSION (LEVEL 1) AND 3 CRACKS FOUND ON LH OMEGA BEAM #2 FLOOR STRUCTURE BTW FR 29-36. BEAM IS REPAIRED WITH 3 DOUBLERSFeb 26, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230315021Unknown · unknownRF1, LH FR68 REINFORCEMENT BRACKET CARGO DOOR HOLDER FOUND CRACKED. AFTER INVESTIGATION, A CRACK IS FOUND ON Z FRAME. Z FRAME SPLICEDFeb 24, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230309010None · noneCRACKS SUSPECTED (14X) ON LH SKIN AROUND FASTENERS BTW FR 77-80 BTW STR 3L-9L. CRACKS SUSPECTED ON LH SKIN AROUND FASTENERS BTW FR 77-80 BTW STR 3L-9L. AFTER NDT INSPECTION, 4 CRACKS FOUND. INSTALLED REPAIR DOUBLER AT FR 78 AND BTW STR 5L-7L.Feb 24, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230309012None · noneREPAIR DOUBLER TO REWORK ON CENTER FUSE 4 UPPER SKIN, BTW FR 56-57 AND BTW STR 2L-1R. REPAIR DOUBLER ON CENTER FUSE 4 UPPER SKIN, BTW FR 56-57 AND BTW STR 2L-1RFeb 21, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230303003None · noneDENTS ON CENTER FUSE I LOWER SKIN, BTW FR 17-19 AND BTW STR 21L-21R. ON CENTER FUSE I, LOWER SKIN, BTW STR 21L-21R DENT FOUND OUT OF LIMIT. ON CENTER FUSE 1, LOWER SKIN BTW FR 17-19 AND BTW STR 21L-21R DENT REPAIRED WITH A DOUBLER. SURFACE REPROTECTION COVEREDFeb 3, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230208009Not Reported · not reportedCF1, CORROSION FOUND ON RH OMEGA BEAM AT FR 23 ON FLOOR STRUCTURE AREA. CORROSION ON RH OMEGA BEAM AT FR 23 AROUND NUTPLATE BLENDED OUT OF LIMTIS. RH OMEGA BEAM AT FR 23 ON FLOOR STRUCTURE REPAIREDFeb 3, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20230208008Not Reported · not reportedDENT ON LH CENTER FUSE 1 SKIN, BTW FR 22-23 AND BTW STR 12L-13L. ON LH CENTER FUSE 1, DENT BTW FR 22-23 AND BTW STR 12L-13L FOUND OUT OF LIMITS. LH CENTER FUSE, BTW FR 22-23 AND STR 12L-13L EXTERNAL SKIN, DENT REPAIRED WITH A DOUBLER.Feb 2, 2023 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220923032Inverter · inoperativeAFT OVERWING EMERGENCY EXIT PLACARD INOPERATIVE. REMOVED AND REPLACED INVERTER #4. OPS CHECK SATSep 23, 2022 · N11189 · Emb EMB145XR · Emergency LightingSDR JJBA20220923031Battery Pack · inoperativeFWD & MIDDLE AISLE EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY AT BPS1. LIGHTS ONLY MOMENTARILY CAME ON. REMOVED AND REPLACED NEWLY INSTALLED POWER SUPPLY AT BPS1. OPS CHECK GOODSep 23, 2022 · N11189 · Emb EMB145XR · Emergency LightingSDR JJBA20220923030Battery Pack · inoperativeMCD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY AT BPS1. LIGHTS ONLY MOMENTARILY CAME ON. REMOVED AND REPLACED NEWLY INSTALLED POWER SUPPLY AT BPS1. OPS CHECK GOODSep 23, 2022 · N11189 · Emb EMB145XR · Emergency LightingSDR JJBA20220505019Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT ASSEMBLY. OPS CHECK SAT.May 5, 2022 · N11189 · Emb EMB145XR · Emergency LightingSDR JJBA20210316046None · noneEXISTING DOUBLER BETWEEN FRAMES 15 AND 16 BETWEEN STRINGERS 10R AND 11R. REPAIR WAS ACCOMPLISHEDMar 16, 2021 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20210316045None · noneCIRCULAR REPAIR DOUBLER INCORRECTLY INSTALLED ON FORWARD FUSELAGE PRESSURE BULKHEAD. INSTALLED DOUBLER ON FWD BULKHEAD AFT SIDE.Mar 16, 2021 · N11189 · Emb EMB145XR · Fuselage Main, StructureSDR JJBA20210306048None · noneEXISTING DOUBLER BETWEEN FRAMES 70-72 + AND BETWEEN STRINGER 11-14L. REMOVED DOUBLER AND REPAIRED REAR FUSELAGE SKIN BETWEEN FRAMES 70-72 AND STRINGERS 11L-14L.Mar 6, 2021 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20210306047None · noneFUSELAGE EXISTING REPAIR LOCATED BETWEEN FRAMES 19-20 STGR 2-4R. REMOVED DOUBLER AND REPAIRED CENTER FUSELAGE I SKIN AT FR 19-20 AND STGR 2-4R.Mar 6, 2021 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20210305044None · noneRECOMPLY WITH EC5310-01446 IN FORWARD AVIONICS BAY. RECOMPLIED WITH EC5310-01446 IN FORWARD AVIONICS BAYMar 5, 2021 · N11189 · Emb EMB145XR · Fuselage Structure (General)SDR ASOA202009224024Control Module · smokeIAH FLIGHT 3907. THE CREW REPORTED AN ELECTRICAL SMOKE ODOR IN THE FORWARD CABIN. MAINTENANCE REMOVED AND REPLACED THE CABIN LIGHT CONTROL MODULE, OPERATIONALLY TESTED WITH NO DEFECTS NOTED AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.Sep 22, 2020 · N11189 · Emb EMB145XR · Passenger Compartment LightingSDR ASOA202003297030Door Sill · corrodedRH FLOOR SILL CORRODED FROM FRAME 29-35. REMOVED AND REPLACED RH FLOOR SILL FRAME 29-35 IAW EMB SRM 51-40-02.Mar 26, 2020 · N11189 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20200310026Frame · damagedFRAME #3 DAMAGED AT STRINGER 14L-16L. REMOVED AND REPLACED FRAME #3 AT STRINGER 14L-16L IAW EMB 145XR SRM 51-40-02 & 51-20-03.Mar 10, 2020 · N11189 · Emb EMB145XR · Fuselage Main, FrameSDR ASOA202003107025Frame · damagedFRAME #2 DAMAGED AT STRINGER 14L-16L. REMOVED AND REPLACED FRAME #2 AT STRINGER 14L-16L IAW EMB 145XR SRM 51-40-02 & 51-20-03.Mar 10, 2020 · N11189 · Emb EMB145XR · Fuselage Main, FrameSDR ASOA2019121073067Wire · inoperativeDURING ROUTINE MAINTENANCE FOUND SERVICE DOOR EMERGENCY LIGHT WAS INOPERATIVE.MAINTENANCE REPAIRED SERVICE DOOR LIGHT WIRING. OPERATIONAL CHECKS WERE GOOD.Dec 7, 2019 · N11189 · Emb EMB145XR · Light System WiringSDR ASOA2018111385316Sign · inoperativePILOT REPORTED "EMERGENCY LIGHT OVER FA JUMPSEAT NOT WORKING". MX REMOVED AND REPLACED EMERGENCY EXIT WARNING SIGN OVER FA JUMPSEAT. A/C WAS APPROVED FOR RETURN TO SERVICE.Nov 8, 2018 · N11189 · Emb EMB145XR · Emergency LightingSDR ASOA20150901166VControl Unit · defectiveSPOILER FAIL ILLUMINATED ON DECENT WITH THRUST LEVERS AT IDLE. R & R SPOILER CONTROL UNIT IAW EMB 145 27-63-02. OPS CK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Sep 1, 2015 · N11189 · Emb EMB145XR · Drag Control SystemSDR ASOA20140620133Floor Support · corrodedDURING C-CHECK, THE RT OMEGA BEAM WAS FOUND TO BE CORRODED BETWEEN FRAMES 23-24. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EC5310-01785. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Jun 20, 2014 · N11189 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20140620132Floor Support · corrodedDURING C-CHECK, THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 59. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EC5320-01950. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Jun 20, 2014 · N11189 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20140620131Floor Support · corrodedDURING C-CHECK, THE RT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 59. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EC5320-01950. ACFT APPROVED FOR RETURN TO SERVICE.Jun 20, 2014 · N11189 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20140620130Beam · corrodedDURING C-CHECK, THE CARGO DOOR CUTOUT LOWER BEAM WAS FOUND TO BE CORRODED. MAINTENANCE R & R THE BEAM IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.Jun 20, 2014 · N11189 · Emb EMB145XR · Fuselage Main, StructureSDR ASOA20140331053Display · failedCREW REPORTED THAT THE NR 1 PFD BLANKED OUT TRIPPING THE CIRCUIT BREAKER. CAUTIONS WERE CHECKED AND A STRONG ELECTRICAL ODOR WAS DETECTED. MAINTENANCE R & R THE AFFECTED PFD, OPS TESTED WITH NO DEFECTS. ACFT APPROVED FOR RETURN TO SERVICE.Mar 31, 2014 · N11189 · Emb EMB145XR · Central DisplaySDR ASOA20131202209Light · malfunctionedCREW REPORTED EMERGENCY LIGHT IN CABIN DOES NOT WORK. MAINTENANCE INSPECTED THE ACFT, RESET THE EMERGENCY LIGHTS, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Dec 2, 2013 · N11189 · Emb EMB145XR · Emergency LightingSDR ASOA20130715074Flapper Valve · leakingPILOT REPORTED A RT WING FUEL LEAK AND PERFORMED AIR RETURN. MX INSPECTED AND FOUND THE RT WING OUTERMOST FLAP VALVE LEAKING. MX R & R THE RT WING FLAP VALVE WITH LEAK CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Jul 15, 2013 · N11189 · Emb EMB145XR · Fuel Storage
Back to N11189