N1181A
Service difficulty reports · 435
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1181A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1181A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2022100601095None · noneDESCENT DEVICE INOP(<P><SPAN>PER CREW, UPON OPENING STORAGE DEVICE. DESCENT REEL DROPPED DOWN. RESECURED DESCENT DEVICE IAW AMM 25-61-05. NO FURTHER DEFECTS NOTED.</SPAN></P>)SDR UIEA2022041900315None · noneENG #1 I/B T/R WITH SEAL DAMAGED LOCATED AT INTERNAL AREA .(<P>PREPARED, CLEANED, AND REPAIRED FIRE RETARDANT SEAL INNER AREA OF ENG. # 1 I/B T/R PER B767-300 AMM 78-31-00-308-072-H00 .</P>)SDR UIEA2022041900316None · noneFWD CARGO CREW OXYGEN NEED SERVICE TO FULL .(<P>REMOVED, SERVICED & REINSTALLED FWD CARGO CREW O2 BOTTLE PER B767-300</P> / <P>AMM 12-15-08, 35-00-00, 35-11-00 & AC 43.13-1B PAR 9-46 THRU 9-51 PGS 9-448 THRU 9-455. </P> / <P>NO LEAKS. P/N B42365-1. S/N SDR UIEA2022041900317None · noneLEFT INB AFT FLAP OB SIDE HAS SEAL MISSING .(<P><SPAN>REMOVED AND INSTALLED SEAL AT LEFT INB AFT FLAP O/B SIDE AS PER 767-300 </SPAN></P> / <P><SPAN>AMM 20-10-23-964-001</SPAN></P>)SDR UIEA2022041900318None · noneRH INB MID FLAP OB SIDE WITH AERODYNAMIC SEAL DAMAGED .(<P><SPAN>REMOVED AND INSTALLED AERODYNAMIC SEAL AT R/H INB MID FLAP O/B SIDE AS PER 767-300</SPAN></P> / <P><SPAN>AMM 20-10-23-964-001</SPAN></P>)SDR UIEA2022041900319Pouch · looseCOCKPIT F/O SEAT LIFE VEST POUCH VELCRO LOOSE .(<P>SECURED VELCRO AT COCKPIT F/O SEAT LIFE VEST AS PER 767-300 AMM 20-30-01-992-001</P>)SDR UIEA2022041900320None · noneCOCKPIT LH STOWAGE LIFE RAFT P/N RO425A-107 S/N TAL6A072 DUE FOR SERVICE.(<P>REMOVED AND REPLACED COCKPIT LOWER LIFE RAFT AS PER B767-300 AMM 25-62-00.</P>)SDR UIEA2022041900321Squib · noneAPU SQUIB P/N 30903856 S/N 01189 DUE FOR TIME CHANGE .(<P>REMOVED & REPLACED APU SQUIB PER B767-300 AMM 26-22-02.</P> / <P>SQUIB TEST PASSED . NEW DUE DATE 31 OCT 29</P>)SDR UIEA2022041900322None · noneCOCKPIT 1ST OBS SEAT BELTS MISSING COTTER PINS(<P>REMOVED AND REPLACED 1ST OBS COTTER PINS IAW B767-300 AMM 20-10-23</P>)SDR UIEA2022041900323Rod · noneENG. #1 O/B CORE COWL HOLD OPEN ROD DAMAGED(<P>REMOVED AND REPLACED #1 O/B CORE COWL HOLD OPEN ROD IAW B767-300 AMM 71-11-11</P> / <P>OPS CHECK GOOD</P>)SDR UIEA2021110802368None · noneEICAS: R GEN OFF AT ENG START, QRH 6.12 ACOMPLISHED + RESET OPS NORMAL(<P><SPAN>COMPLETED WITH OPS CHECK FOR RH GEN IN REF. AMM 71-00-00. ( ENT RUN ). OPS CHECK GOOD. NO FAULTS NOTED. </SPAN></P>)SDR UIEA2021102302276Flap · noneLH WING I/B FLAP LOWER SURFACE HAS BULGING AREA AT FASTENER ROW JUST I/B OF O/B TRACK.(<P>REMOVED CORROSION LH WING I/B FLAP LOWER SURFACE. ORIG. MAT. WAS .125" REMAINING MAT. IS .034" IS FOUND TO BE OUT OF LIMITS IAW B767 SRM 57-53-01. REMOVED AND REPLACED LHSDR UIEA2021102502279Light · noneFLIGHT DECK ENTRYWAY L/H SIDE AFT END OF SLIDE CONTAINER BOTTOM SIDE EMERGENCY EXIT LIGHT CRACKED AND DAMAGED. CAUTION: COULD BE HAZMAT HAZARD.(<P>REMOVED AND REPLACED FLIGHT DECK ENTRYWAY L/H SIDE AFT END OF SLIDE CONTAINER BOTTOM SIDE EMERGENCY EXIT LIGHT IASDR UIEA2021102502280None · noneAREA OF CORROSION ON R/H HORIZ STAB UPPER SURFACE AT FRONT SPAR JUST O/B OF BANANA FAIRING.(<P>BLENDED THE AREA ON THE R/H HORIZONTAL STABILIZER UPPER SURFACE AT FRONT SPAR JUST O/B OF THE BANANA FAIRING IAW B767 SRM 51-10-02. UPON THE EVALUATION THE AREA WAS SDR UIEA2021100602197None · noneF/O ESCAPE ROPE PANEL WILL NOT LATCH CLOSED.(<P>RE-SECURED FO ESCAPE ROPE PANEL IN REF AMM 25-61-05.</P>)SDR UIEA2021092702131Warning Message · false activationSTATUS MESSAGES AFT EQ FAN 1 & AFT EQ FAN 2(<P>FLIGHT CREW FOUND FWD & AFT CARGO FIRE ARM SWITCHES DEPRESSED. CYCLED SWITCHES. NO MESSAGES PRESENT AT THIS TIME, DONE IAW B767 AMM 26-19-00.</P>)SDR UIEA2021091602028Engine · warning messageUPON SHUTTING DOWN LEFT ENGINE L AC BUS MESSAGE DISPLAYED REMAINED ILLUMINATED UNTIL EXT POWER SELECTED.(<P>PERFORMED FIM TASK 24-32 FT803 BLOCKS 1 AND 2 FOLLOWED BY ENGINE RUN IAW AMM 71-00-00. OPS NORMAL AT THIS TIME. NO FURTHER DEFECTS NOTED. NUSSIANCE FAULSDR UIEA2021082301849Blade · nickedSMALL CHIP ON OUTER FAN BLADE # 18 OF RIGHT ENGINE(<P>NICK FOUND TO BE WITHIN REPAIRABLE LIMITS, BLENDED PER AMM 72-31-02. NO FURTHER DEFECTS NOTED. OK FOR SVC. TRANSFERRED TO NON MEL 152213 FOR DYE PENETRANT WITHIN 50FH 0R 10 FC,</P> / <P><SPAN>LP 1368567: PSDR UIEA2021080801746Start Valve · faultedR STARTER CUTOUT EICAS MESSAGE ILLUMINATED MOMENTARILLY. WHILE AT CRUISE. REPEATED SEVERAL TIMES BUT ONLY FOR A SECOND AT A TIME.(<P>R/R RIGHT ENG STARTER VALVE PER AMM 80-11-02. PERF ENG RUN IAW AMM 71-00-00. OPS TEST NORMAL, NO DEFECTS NOTED, ITEM 2 IS RELATSDR UIEA2021080651708Fault Light · false activationAPU FAULT EICAS DURING TAXI IN.(<P>PERFORMED APU BITE TEST PER FIM 45-11 FT 958. NO FAULTS FOUND. NO MINI FLAGS APU OIL LEVEL GOOD. OPS TESTED APU NORMAL PER AMM 49-11-00 </P>)SDR UIEA2021072701633Warning Light · false activationEQUIPMENT COOLING "VALVE "LIGHT ILLUMINATED.(<P>CYCLED EQUIPMENT COOLING SELECTOR SWITCH FROM "AUTO" TO "STBY" REF B767 AMM 21-58-00 VALVE CLEARD ONCE SWITCH WAS TAKEN BACK TO AUTO. NO FURTHER EFFECTS NOTED.</P>)SDR UIEA2021072601625Pneumatic System · unknownAPU PNEUMATICS INOP. T/S IAW FIM 49-11 FAULT TREE. NO FAULTS FOUND. PERFORMED VISUAL INSPECTION ON APU BLEED AIR DUCT IAW AMM 36-11-02. NO DEFECTS FOUND. PERFORMED ENGINE RUN IAW AMM 72-00-00.SDR UIEA2021072301616Warning Message · false activationSTATUS 'AFT EQ EXH FAN 2'(<P>PERFORMED FIM TASK 21-26 FAULT TREE 808. NO FAULTS FOUND. COULD NOT DUPLICATE. OPS CHECKS GOOD.</P>)SDR UIEA2021072301617Warning Message · false activationR ENG STARTER EICAS MSG DURING ENG START. 2ND. ATTEMPT OK.(<P>PERFORMED R/H ENG STARTER VALVE OPS CHECK IAW B767 AMM 71-00-00. NO DEFECTS NOTED AT THIS TIME. A/C OK FOR SERVICE.</P>)SDR UIEA2021072101604Warning Message · false indicationAFTER SHUTDOWN TR UNIT STATUS MESSAGE DISPLAYED(<P><SPAN>PERFORMED T/S PER FIM 24-32 F/T 803, NO DEFECTS NOTED, SYSTEM OPS CHECK NORMAL.</SPAN></P>)SDR UIEA2021071901586Switch · faultedAPU DEFERRED PER MCC (INOP)(<P>TRANSFER TO MDDR DMI #150314 IAW B767 DDG MEL 49-11-01A, CAT C, DUE 27JUL21 "M" PROC C/W. </P> / <P>C/W WITH ECM #2021P-233 REF. LOGPAGE 1369494 ITEM 8...REPLACED DE-OIL SOLENOID VALVE.. P/N 3876166-1..S/N 1102 ON APU IAW AMM49-SDR UIEA2021071201520Unknown · leakingEXCESSIVE OIL FOUND ON INBOARD SURFACE OF LEFT ENGINE EXHAUST COWL (6 O'CLOCK POSITION).(<P>OPENED AND INSPECTED LEFT ENGINE EXHAUST COWL FOR OIL LEAKS, NO LEAKS NOTED.</P>)SDR UIEA2021070901496Circuit Card · faultedEICAS MSG "R STARTER CUTOUT" INTERMITTENTLY DISPLAYED IN CRUISE FOR ABOUT 3-5 SECONDS.(<P>RIGHT STARTER VALVE PREV REPLACED ON 03APR21. PERFORMED OPS CHECK IAW AMM 71-00-00. OPS CHECK OK. DUE TO HISTORY REPLACED N2 SPEED CARD (M1092) IAW AMM 73-21-54. REMOVED SDR UIEA2021070701480Warning Light · false activationDURING CLIMB WHEN SELECTING L ENG ANTI-ICE FROM ON TO OFF THE L ENG ANTI ICE EICAS MESSAGE DISPLAYED FOR APPROX 3-5 SECONDS, WENT AWAY(<P>PER AMM 30-21-00 SYSTEM OPERATES NORMAL. NO FURTHER DEFECTS NOTED AT THIS TIME.</P>)SDR UIEA2021070701481Warning Message · false activationWHEN SHUTTING DOWN LEFT ENGINE IN THE BLOCKS, THE L AC BUS FAILED.(<P>T/S PER FIM 24-32 FT 803, SYSTEM TEST OK, T/S PER FIM 24-20 FT 801. NO FURTHER DEFECTS NOTED AT THIS TIME, A/C IS OKAY FOR FURTHER SERVICE.</P>)SDR UIEA2021070201468Starter · malfunctionedBAD POWER TRANSFER STARTING RT ENGINE. RETURN TO BLOCK TO POWER RESTART.(<P>PERFORMED RESET IAW AMM 24-22-00 RT GEN PER RH ENG RUN IAW 71-00-00 POWER TRANSFER SUCCESSFUL. NO FUTHER DEFECTS NOTED.</P>)SDR UIEA2021062001386Transceiver · faultedL WX RADAR FAILED TWICE IN FLIGHT, SWITCHED TO R WX RADAR AND THE SYSTEM WORKED NORMALLY.(<P>TRANSFERRED TO DMI # 148947, CAT D, DUE DATE 18OCT21 IAW DDG 34-43-01 T.I. LUC 2223Z.</P> / <P>CVG MX, 21JUN21, LP 1444308, ITEM M7: REMOVED AND REPLACED WX RADAR TRANSDR UIEA2021061401345Modulating Valve · failedFWD CABIN INOP(<P>PERFORMED FIM 21-60 FT 804 ZONE TEMPERATURE BITE PROCEDURE FAULT LIGHT FOR FWD ZONE TRIM VALVE: ILLUMINATED & PERFORMED FIM 21-60 FT 811 HAD FWD TEMP MSG & FWD CAB INOP LIGHT. REMOVED AND REPLACED FWD TRIM AIR MODULATING VALVE IAW AMM 21-61-0SDR UIEA2021061401344Anti-Ice Valve · faultedLEFT ENG ANTI ICE VALVE DID NOT CLOSE WHEN SWITCH OFF(<P>PERF OPS CHECK OF L ENG TAI VALVE, OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME. REF: 30-21-03-404-022</P>)SDR UIEA2021061001310Transceiver · failedL RADAR "WXR FAIL" DURING CLIMB. WHEN IT WAS OPERATIONAL, IT APPEARED TO BE TILTED LOWER THAN SELECTED TILT.(<P>REMOVED AND REPLACED L/H R/T TRANCEIVER IAW B767 AMM 34-43-01. OPS CHECK GOOD AT THIS TIME.</P>)SDR UIEA2021060901305Fire Loop · malfunctionedRT FIRE LOOP1, RT FIRE LOOP 2(<P>REMOVED AND REPLACED RT ENG FIRE LOOP 1 AMM 26-11-02. REMOVED AND REPLACED RT ENG FIRE LOOP 2 DET ELEMENT. OPS NORMAL IAW AMM 26-11-02.</P>)SDR UIEA2021060401268Warning Message · false activationFWD CABIN TEMP EICAS MSG PRIOR TO BLOCK OUT(<P>DEFER PER MEL 21-61-01-02 CAT C DUE 13JUN21 REF MDDR 147976 CW AT 22:41Z.</P><P>LOG 1343041 ITEM #4 TROUBLE SHOOT PER FIM 21-60 FAULT TREE 806. MESSAGE NOT DISPLAYED. OPS NORMAL. THIS CLEARS MDDR #147976. ID@0118ZSDR UIEA2021060701279Warning Message · false activationFWD CABIN TEMP EICAS MESSAGE.(<P>PERFORMED BITE ON ZONE TEMP CONTROLLER. PER 21-60-99 MSG CLEARED, OPS CK NORMAL, NO FAULTS NOTED.</P>)SDR UIEA2021060101214Tru · faultedAPU FAULT ON FIRST ATTEMPT START OK(<P>TRANSFERRED TO DMI # 147866 CAT C DUE DATE 11 JUN 21 IAW DDG 49-11-01A </P><P>CVG MX, 01JUN21 LP 1306574, ITEM M8: PERFORMED FIM 49-11 TREE 959 & FIM 49-11 963, FIM LEAD TO APU TRU. REMOVED & REPLACED APU TRU IAW 767 AMM SDR UIEA2021050701084Start Valve · faultedR ENG STR CUTOUT EICAS ON SHORT FINAL WENT AWAY TWICE. AFTER LOADING EICAS CAME BACK AND STAYED. RAN QRH CHECK LIST ITEMS.(<P>REMOVED AND REPLACED START VALVE IAW AMM 80-11-02. OPS CHECKS NORM AT THIS TIME. LEAK CHECK GOOD AT THIS TIME.<BR /></P>)SDR UIEA2021050601071Igniter · failedSTATUS MSG R ENG IGNITOR 2(<P>REMOVED AND REPLACED RT ENG IGNITOR 2 IAW AMM 74-21-02. OPS CHECK GOOD NO FURTHER DEFECTS NOTED. STATUS MSG CLEARED.<BR /></P>)SDR UIEA2021050301054Warning Message · false activationRT E/I VALVE DISAGREE LIGHT ILLUMINATED PRIOR TO ENG START. VALVE OPERATED NORMALLY BUT SLOW POST START. START CONDUCTED W/ MX AND DISPATCH CONCURRENCE.(<P>C/W ENGINE INLET TAI VALVE OPS CHECK, CHECKS GOOD PER AMM 30-21-03-404-022 SUBTASK 30-21-03-714-062.</P>SDR UIEA2021043001027Warning Light · false activationRT E/I VALVE DISAGREE LIGHT ILLUMINATED PRIOR TO ENG START. VALVE OPERATED NORMALLY(BUT SLOW) POST START. START CONDUCTED W/ MX & DISP. CONCURRENCE.(<P>C/W ENGINE INLET TAI VALVE OPS CHECK, CHECKS GOOD, PER AMM 30-21-03-404-022 SUBTASK 30-21-03-714-062</P>)SDR UIEA2021042801016Inertia Reel · detachedONE ESCAPE INERTIAL REEL FELL OUT OF HOLDER ON TAKE OFF. 6 EACH SERVICEABLE. COMPLIED WITH REEL REMOVAL FROM PLANE SPACER REINSTALLED BACK IN POSITION.</P><P>INSTALLED ESCAPE REEL IAW AMM 25-61-02. THIS CLEARS MDDR 146036. PLACARD REMOVED, MCC NOTIFIED</P>)SDR UIEA2021042100944Escape Reel · unwanted deployDURING TRANSIT CHECK FOUND DESCENT DEVICE DEPLOYED. P/N 379103D-29, SERIAL NO. 20985(<P>TRANSFER TO MDDR 145610 PER MEL 25-61-01-01, CAT C. DUE 30APT21. PLACARDS INSTALLED. DEVICE REMOVED PER MEL. DF 09:58Z</P><P>ONT MX, 21APR21, LP 695223, ITEM M6: INSTALLED SDR UIEA2021042100947Warning Message · false activationFWD CABIN TEMP EICAS MSG.(<P>TRANSFERRED TO MDDR # 145639 OAW MEL 21-61-01-02 DUE DATE: 30APR21 CAT "C". C/W MX PROCEDURE. SP 2315Z</P><P>21APR, ONT MX LP 695222, ITEM M3: PERF OPS CHECK OF ZONE TEMP CONTROL SYSTEM IAW AMM 21-61-00. OPS CHECK GOOD, NO PREVIOUSSDR UIEA2021041700919Gcu · malfunctionedAFTER R ENG START, R GEN WAS INOP(<P>REMOVED AND REPLACED RIGHT ENG GCU PER AMM 24-22-01. OPS TEST GOOD, NO DEFECTS NOTED. ENG RUN PER AMM 71-00-00, OPS GOOD. PLACED .62 ELEC LOAD TO ISOLATE RT GEN APPROX. 5 MINS, NO FAULTS NOTED.</P>)SDR UIEA2021041100875Warning Message · false activation"OVERSPEED" MSTR WARNING EICAS FLASHED BRIEFLY DURING #2 ENG. START.(<P>A/C ON GROUND DURING "OVERSPEED" INDICATION. C/W FIM FT 34-90-49-00. ADC OPS TEST GOOD PER AMM 34-12-00-715-001. ACCOMPLISHED #2 ENG RUN PER 71-00-00-862-053-H03, FAULT NOT REPRODUCED. NO SDR UIEA2021040300815Start Valve · faultedR STARTER CUTOUT EICAS MESSAGE IN FLIGHT(<P>TRANSFERRED TO MDDR 144761 MEL 80-00-02-01 CAT C. 4 APR 2021</P><P>3 APR 2021-LOG PAGE 1465749 M7: REMOVED AND REPLACED #2 ENG START VALVE, IAW AMM 80-11-02, OPS CHECK GOOD. THIS CLEARS DMI 144761, PLACARDS REMOVED.<SDR UIEA2021033000754Pouch · looseCOCKPIT CAPT SEAT LIFE VEST POUCH LOOSE VELCRO(<P>SECURED LIFE VEST POUCH AT COCKPIT CAPT SEAT IAW B767 AMM 20-30-01</P>)
Back to N1181A