N13161
Service difficulty reports · 78
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N13161' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N13161' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20250825055Skin · dentedDENT/CREASE WAS IDENTIFIED IN THE FORWARD FUSELAGE 1 AREA, LOCATED BETWEEN FRAMES 1A AND 2 AND BETWEEN STRINGERS 15R AND 13R. NO STRUCTURAL DEFORMATION OR ADDITIONAL ANOMALIES WERE OBSERVED. PERMANENT REUNFORCING REPAIR PERFORMED ON RF FWD DUSELAGE SKIN AT FRASDR JJBA20250623017Lamp · inoperativeMCD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXTERNAL EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250520082Charger · inoperativeMCD FAIRING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK FAIL. REMOVED AND REPLACED LIGHT ASSEMBLY. OPS CHECK FAILED. REMOVED AND REPLACED LIGHT BATTERY CHARGER. OPS CHECK SAT.SDR JJBA20250210011Lamp · inoperativeAFT CEILING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED AFT EMERGENCY CEILING LIGHT LAMP. OPS CHECK SAT.SDR JJBA20250110010Transceiver · intermittentWEATHER RADAR FAILED INTERMITTENTLY IN FLIGHT. REMOVED AND REPLACED WEATHER RTA AND W025 HARNESS. OPS CHECK GOOD. NO DEFECTS NOTED.SDR JJBA20241018011Lamp · inoperativeAISLE CEILING EMERGENCY LIGHT AT SEAT 22A INOPERATIVE. REMOVED AND REPLACED AISLE CEILING EMERGENCY LIGHT LAMP. OPS CHECK SAT.SDR JJBA20240708002Lamp · inoperativeRH FWD LOWER FAIRING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED RH FWD LOWER FAIRING EMERGENCY LIGHT BULB. OPS CHECK SAT.SDR JJBA20240219040Flashlight Assy · inoperativeFLASHLIGHT ABOVE THE FLIGHT ATTENDANT SEAT HAS WORN BRACKET CAUSING CHARGE TO BE INTERMITTENT. REMOVED AND REPLACED FLASHLIGHT ASSEMBLY ABOVE FA SEAT. RED LIGHT ILLUMINATED. OPS CHECK GOOD.SDR JJBA20230612006Battery Pack · inoperativeFOUND RH FWD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED #2 EMERGENCY LIGHT BATTERY. OPS CHECK SAT. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR JJBA20230123017Lamp · inoperativeFWD MOST CENTER AISLE CEILING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LIGHT BULB AT FWD MOST CEILING LINING EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20230119015Lamp · inoperativeMCD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXTERNAL EMERGENCY LIGHT. OPS CHECK SATSDR JJBA20220919025None · trippedSMOKE IN COCKPIT BURNING SMELL. INSPECTED THE COCKPIT AND FOUND EICAS DISPLAY CB WAS EXTENDED. REMOVED AND REPLACED EICAS DISPLAY UNIT. RESETED DISPLAY CB. OPS CHECK SATSDR JJBA20220721027Light · inoperativeMCD EMERGENCY LIGHT INOP. R/R MCD EXTERNAL EMER. LIGHT ASSY. OPS CHECK SATSDR JJBA20220721026Light · inoperativeAFT EXIT SIGN AT EMERGENCY EXIT ROW INOP. R&R EXIT SIGN AT EMERGENCY EXIT ROW. OPS CHECK FAIL. FOUND INVERTER TO BE BAD R&R INVERTER. OPS CHECK SATSDR JJBA20220429032Lamp · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED COCKPIT EMERGENCY EXIT LIGHT LAMP. OPS CHECK SATSDR JJBA20220429031None · wrong partINCORRECT EXIT MARKER INSTALLED ON FLOOR PROXIMITY LIGHT ALONGSIDE SEAT 24A. REMOVED AND REPLACED EXIT MARKER. NO DEFECTS NOTED.SDR JJBA20220314038Not Reported · not reportedAFTER NDT INSPECTION, BOTH PYLON SPAR II YOKE HOLES HAVE INDICATIONS. X2 BUSHINGS FLUSH - PYLON-00 LOCALLY FABRICATED. DAMAGED HOLES ON PYLON SPAR II YOKES REPAIRED.SDR JJBA20220228025Not Reported · not reportedAT REAR FUSE EXT, CORROSION FOUND ON SKIN UNDER FWD RAD ALT. ASE BTW FR 6566 AND BTW STR 21L-21R. AT REAR FUSE EXT, UNDER FWD RAD ALT BASE BTW FR 65-66 AND BTW STR 21L-21R REMOVED FOR CORROSION ACCESS. FWD RAD ALT BASE BTW FR65-66 AND BTW STR 21L-1R BLENDED OUSDR JJBA20220228024Not Reported · not reportedAT CFIV, CORROSION FOUND ON RH BEAM IN LAVATORY AREA BTW FR 59-6. AT CFIV, ON RH BEAM IN LAVATORY AREA BTW FR 59-61, PAINT REMAIOVED FOR INVESTIGATION. AT CFIV CORROSION ON RH BEAM IN LAV AREA BTW FR 59-61 REPAIRED.SDR JJBA20220228023Not Reported · not reportedAT CF II AREA FOUND ON RH FRAME 25 BTW STR 15R-16R. CFII, CRACK ON RH FRAME 25 BTW STR 15R-16R REPAIREDSDR JJBA20211020057Battery Pack · inoperativeEMERGENCY EXIT SIGN INOPERATIVE OVER ROW 18. REMOVED AND REPLACED BATTERY (EMERGENCY) PACK AND R&R BATTERY CHARGER ASSEMBLY. OPS CHECK GOOD.SDR JJBA20210630046Light · inoperativeMCD EXTERNAL EMERGENCY LIGHT INOPERATIVE. R&R MCD EXTERNAL EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20210321003Armrest · crackedFOUND CRACK IN PAX SEAT ARMREST AT 2A. REMOVED AND REPLACED PAX SEAT AT 2A.SDR JJBA20210306003Sign · inoperativeAFT CEILING EMERGENCY EXIT SIGNS INOPERATIVE. R&R AFT CEILING EMERGENCY EXIT SIGN. OPS CHECK SAT.SDR JJBA20210107001Fuse · failedAISLE EMERGENCY OVERHEAD AFT LIGHT LAMP INOPERATIVE. REMOVED BATTER POWER SUPPLY NR 1, 2, 3, AND 4. PERFORMED CONTINUITY TEST OF FUSES ON NR 3 EMERGENCY LIGHT BATTERY CHARGER. FUSE F3 FAILED. R & R CHARGER. OPERATIONS CHECK FAIL. LT EXIT IDENTIFIER LIGHTSDR JJBA202001109002Warning Message · false activationLG/AIR GROUND FAIL IN AIR, MESSAGE WENT AWAY AFTER QRH WAS PERFORMED (MESSAGE APPEARED IMMEDIATELY WHEN GEAR SELECTED DOWN, WENT AWAY ON ITS OWN AFTER 4-5 MIN). SERVICED NLG. C/W LANDING GEAR SWING. OPS GOOD.SDR JJBA201912165004Bulb · inoperativeMCD EMERGENCY LIGHT IS INOPERATIVE. REMOVED AND REPLACED LIGHT BULB. OPS CHECK GOOD.SDR JJBA20190815006Light · inoperativeMAIN CABIN DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MAIN CABIN EMERGENCY LIGHT ASSEMBLY. OPS CHECK GOOD.SDR JJBA20190627017Light · inoperativeLT EMERGENCY LIGHT FWD OF WING IS INOPERATIVE. R&R LT EMERGENCY LIGHT FWD OF WING. OPS CHECK SAT.SDR JJBA201906032003Connector · unsecureEMERGENCY EXIT SIGN ON CABIN CEILING IS NOT ILLUMINATED. TIGHTENED PLUGS TO EMERGENCY EXIT SIGN AS REQUIRED. OPS CHECK SAT.SDR JJBA201904220013Anti-Ice Valve · failedE2 A/ICE FAIL. PERFORMED QRH OF E2 ANTI ICE VALVE FAILURE. NO FAULTS PRESENT. FOLLOWED FIM E2 A/ICE VLV FAIL MESSAGE AND PERFORMED BLEED AIR TEST. NO MESSAGES OR FAULTS.SDR JJBA201904220012Anti-Ice Valve · failedWING A/ICE FAIL MESSAGE. PERFORMED QRH OF E2 ANTI ICE VALVE FAILURE. NO FAULTS PRESENT. FOLLOWED FIM E2 A/ICE VLV FAIL MESSAGE AND PERFORMED BLEED AIR TEST. NO MESSAGES OR FAULTS.SDR JJBA20190105018Battery Pack · dischargedEMERGENCY SIDEWALL AND AFT CEILING LIGHTS AT EMERGENCY ROW INOPERATIVE. R&R EMERGENCY BATTERY POWER SUPPLY 3. OPS CHECK SAT.SDR JJBA201808141010Liner · out of positionLT AND RT PASSENGER CABIN ESCAPE HATCHES SNAG ON UPPER PART OF SIDEWALL LINING WHICH PREVENTS THEM FROM OPENING. REMOVED AND ADJUSTED THE EMERGENCY EXIT SIDE WALLS. ESCAPE HATCHES NO LONGER SNAG ON LININGS.SDR JJBA2018081408009Floor Support · corrodedCORROSION ON THE CENTER OMEGA BEAM AT FRAME 23, 100% MATERIAL LOSS. REMOVED AND REPLACED THE OMEGA BEAM BETWEEN FR 16-24.SDR JJBA2018081408008Floor Support · crackedCRACKED RT OMEGA BEAM INBD SUPPORT BETWEEN FRAMES 47 - 48. REMOVED AND REPLACED THE OMEGA BEAM SUPPORT.SDR JJBA2018081408007Floor Support · crackedCRACK FOUND IN THE LT OMEGA BEAM OTBD SUPPORT BETWEEN FRAMES 47 - 48. REMOVED AND REPLACED THE OMEGA BEAM OTBD SUPPORT.SDR JJBA2018081407006Skin · gougedFUSELAGE SKIN HAD THREE GOUGES UNDER THE UPPER TCAS ANTENNA FROM SURFACE CONTACT. REPAIRED THE SKIN AT FRAMES 16 - 17, STRINGERS 1L - 1R.SDR JJBA2018081404005Skin · dentedSKIN DENTED BETWEEN FRAMES 23 AND 24, STRINGERS 14R AND 15R. INSTALLED A REPAIR DOUBLER AND FILLER.SDR JJBA2018081404003Skin · gougedRIGHT LEADING EDGE WAS DEEPLY GOUGED BETWEEN RIBS 1 & 2. APPROXIMATELY 4 INCHES ABOVE LANDING LIGHT CUT-OUT. INSTALLED FABRICATED PARTS TO RH LEADING EDGE 611.SDR JJBA2018081401002Floor Support · corrodedCORROSION FOUND ON THE LT OMEGA BEAM AT FRAME 20. REMOVED AND REPLACED A REPAIR DOUBLER ON THE LT OMEGA BEAM.SDR JJBA2018081404004Support · crackedCRACKED RT OMEGA BEAM OTBD SUPPORT BETWEEN FRAMES 47 - 48. REMOVED AND REPLACED THE OMEGA BEAM SUPPORT.SDR JJBA2018081401001Floor Support · corrodedCORROSION ON THE RT OMEGA FRAME 23. REPAIRED THE OMEGA BEAM .SDR JJBA20180219002Pressure Switch · failedRUDDER 1 - 2 INOPERATIVE ON EICAS. DIVERTED. R & R SYSTEM 2 PRESSURE SWITCH IAW FIM AMM. OPS CHECKED SAT.SDR JJBA20171223012Lamp · inoperativeEMERGENCY LIGHT BY THE MAIN CABIN DOOR HAS A LAMP OUT. R & R THE LAMP IAW AMM 33-50-00. OPS CHECKED GOOD.SDR JJBA20170826024Connector · unsecureOVERHEAD EMERGENCY LIGHT AT ROW 18 INOPERATIVE. SECURED A LOOSE CONNECTOR. OPS CHECKED GOOD.SDR ASOA201612063086Control Panel · faultyTHE CREW REPORTED A LAVATORY SMOKE WARNING SHORTLY AFTER TAKEOFF ON EICAS AND IN GALLEY. NO EVIDENCE OF SMOKE , FIRE, OR SMELL WAS NOTED. MAINTENANCE INSPECTED AND REPLACED THE LAV SMOKE DETECTOR PANEL AND OPERATIOMNAL CHECKS WERE GOOD.SDR ASOA201612053085Connector · dirtyTHE CREW REPORTED LAV SMOKE WARNING MESSAGE . NO SMOKE FIRE OR ODOR WAS NOTED. MAINTENANCE INSPECTED AND REMOVED THE CONNECTOR P8100, CLEANED AND REINSTALLED. OPS CHECKED GOOD.SDR ASOA201611086148Beam · corrodedDURING C-CHECK, THE CARGO DOOR CUTOUT LOWER BEAM WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE BEAM IAW SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20160306017Light · inoperativeTHE CREW REPORTED EMERGENCY AISLE PATH LIGHT STRIP BETWEEN ROW 2 AND 3A WOULD NOT TEST. MAINTENANCE REPLACED THE AISLE PATH LIGHT STRIP BETWEEN ROW 2 AND 3A.OPS CHECKS WERE GOOD.
Back to N13161