N1373A
Service difficulty reports · 479
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1373A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1373A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2021092402107Outflow Valve · closedAUTO 1 AND AUTO 2 CABIN PRESSURE INOP. OUTFLOW VALVE DOOR KEEPS CLOSING UNCOMMANDED.(<P>PERF FIM 21-31 FT 803 CABIN PRESSURE BITE NO FAULTS WHERE FOUND. RESET CONTROLLER AND EVERY MODE OPERATES NORMAL.</P>)SDR UIEA2021091102008Warning Message · false activationSTATUS MSG "R ENG HPSOV"(<P>PERFORMED BITE TEST OF THE AIR SUPPLY CONTROL SYSTEM IAW B767 AMM 36-23-00. NO FAULTS FOUND. PERFORMED DRY MOTOR OF R/H ENG IAW B767 AMM 71-00-00. NO DEFECTS NOTED AT THIS TIME. PERFORMED R/H ENG IDLE RUN IAW B767 AMM 71-00-00. NO FSDR UIEA2021091102009Terminal · brokenSTATUS MSG "R ENG HPSOV"(<P>TRANSFERRED TO DMI 153387 IAW MEL 36-11-02-02, CAT C.</P> / <P>LP 1392180: PERFORMED BITE TEST OF THE AIR SUPPLY CONTROL SYSTEM IAW B767 AMM 36-23-00. FOUND R/H HPSOV WIRE FAULT. FOUND WIRE ON HPSOV BROKEN. REPLACED BROKEN TERMINAL SDR UIEA2021082001830Hmu · faultedRT ENGINE CONTROL ADVISORY AND STATUS MESSAGE. PERFORMED FIM FOR PIMU MSG 155-23-A/B FMV SENS DISAGREE. REMOVED AND REPLACED HMU IAW AMM 73-21-14. OPS CKS GOOD PER POWERPLANT TEST #2 AND #3 IAW AMM 71-00-10. NO DEFECT NOTED. OK FOR SVC.SDR UIEA2021081601811Radar · malfunctionedBOTH WXR INOP(<P>RESET BOTH WXR, REBOOTED A/C. OPS TESTED W/ 34-43-00. BOTH SYS WORKING AT THIS TIME. A/C OK FOR SERVICE.</P>)SDR UIEA2021080901755Eec · failedR ENG CONTROL EICAS CAUTION & STS AFTER ENG START(<P>REMOVED & REPLACED RT ENG EEC AS PER MM 73-21-15. NO FAULTS NOTED </P>)SDR UIEA2021080401700Charger · inoperativeAFTER LANDING APU WOULD NOT START AFTER 3 ATTEMPTS(<P>PERFORMED FIM TASK 49-11 F/T 959. FOUND APU BATTERY CHARGER NOT WARNING PROPERLY. REMOVED AND REPLACED APU BATTERY CHARGER IAW AMM 24-31-05. STARTED APU SUCCESSFULLY 3 TIMES. OPS CHECK GOOD. NO OTHER DEFECTSDR UIEA2021080201674Apu · unknownUPON LANDING APU FAULTED OIL QTY SHOWED NORMAL. ON 2ND ATTEMPT OIL QTY SHOWED .25, IT THEN CLIMBED TO .75, TRIED 3RD ATTEMPT OIL Q FULL AND STARTED NORMALLY(<P>NOTED BY MX. PERFORMED 3 ATTEMPTS IAW AMM 49-11-00. ALL ATTEMPTS SUCCESSFUL. NO OTHER DEFECTS NOTED SDR UIEA2021071901590Controller · malfunctionedAVM MONITOR MAINTENANCE MSG APPEARED PRIOR TO DEPARTURE(<P><SPAN>REMOVED & REPLACED AVM SIGNAL CONTROLLER IAW AMM 77-31-03. OPS CHECK GOOD IAW AMM 77-31-03 AND 71-00-00. NO MSG PRESENT AT THIS TIME</SPAN></P>)SDR UIEA2021070201462Warning Message · false indicationR BLD DUCT LEAK MSG(<P>TRANSFERRED TO MDDR # 149543 IAW MEL # 26-18-01-01-01 CAT : C DUE DATE: 11JUL21.</P> / <P>02JUL21 - 1461062 - ITEM# 3 - STL - PERFORMED T/S PER FAULT CODE 26-90-07-42 AND FIM 26-18 FT 804. BLOCKS 1-11. SYSTEM TEST OK. NO FAULTS NOTED AT SDR UIEA2021062901442Warning Message · false activationR BLD ISLN VAL MESSAGE(<P>PERFORMED BITE TEST PER AMM B767 36-23-00. NO FAULTS FOUND AT THIS TIME.</P>)SDR UIEA2021062901441Line · leakingFOUND LEAK AT LH ACM SENSE LINE(<P>THIS BECOMES MDDR 149360 PER MEL 21-51-01-01 CATG C DUE 08JUL21.</P> / <P>30JUN21 - 1461052 - ITEM# 6 - ONT - REMOVED THE L/H ACM IAW AMM 21-51-03 UP TO AND INCLUDING STEP H, SUBTASK 10.</P> / <P>30JUN21 - 1461053 - ITEM# 7 -SDR UIEA2021062801429Warning Message · false activationEICAS MSG "R BLD DUCT LEAK".(<P>KPERFORM BITE CHECK OF AIR SUPPLY MODULE, NO FAULT MESSAGE NOTED AT THIS TIME. PERFORMED WING AND BODY DUCT LEAK DETECTION BITE PROCEDURE IAW FIM TASK 26-18 BLOCK (1). OPERATED BOTH ENGINES WITH BOTH PACKS ON AND VERIFIED RIGHT SDR UIEA2021062501413Elt · damagedPORTABLE ELT CORD FOUND PULLED/BROKEN.(<P>REMOVED & REPLACED PORTABLE ELT IAW AMM 25-63-03. OPS CHECK NORMAL AT THIS TIME.</P>)SDR UIEA2021061201334Lamp · inoperative#2 ENG LOW OIL PRESS LIGHT INOP(<P>TRANSFERRED TO MDDR 148412, DUE 21JUN21, MEL 79-33-01-01, CAT C, TI LC 2052. MCC NOTIFIED. PLACARDS INSTALLED.</P> / <P>12JUN21 - TPA - LP1465362 - ITEM #4 - TPA - RELAMPED LIGHT, OPS CHECK OK. THIS CLEARS MDDR 148412.</P>)SDR UIEA2021060801290Ecu · faultedAPU INOP. APU FAILED COLD SOAK START(<P>THIS BECOMES MDDR 148218 PER MEL 49-11-01A, CAT C, DUE 18JUN21. PERFORMED APU FIM 49-11 FAULT TREE 958 AND FOUND CODE 01 ON ECU DURING BITE. </P><P>LP 1465341: REMOVED AND REPLACED APU ECU IAW AMM 49-61-05. OPS CHECK GOOSDR UIEA2021060701286Warning Message · false indicationREF DAILY CHECK STEP 2A(4), ECS RIGHT ENGINE IGNITER 2 MSG(<P>PERFORMED T/S PER FIM 74-00 F/T 811, NO DEFECTS NOTED, PERFORMED IGNITION SYSTEM TEST, OPS CHECK NORMAL IAW AMM 74-00-00.</P>)SDR UIEA2021060701288Pump · intermittentLEFT AFT FUEL PUMP INTERMITTENT.(<P>PERFORMED OPS TEST IAW BOEING 767 AMM 28-22-00, OPS CHECK GOOD AT THIS TIME</P>)SDR UIEA2021052301165Blades · dentedFOUND LEADING EDGE FAN BLADES ON #1 ENGINE BLADES 4, 6, 7, 13, 15, 16, 29, 34, & 36 TO HAVE MINOR DENTS.(<P>INSPECTED FAN BLADES IAW B767 AMM 72-31-02. ALL BLADES FOUND TO BE WITHIN AMM LIMITS FOR SERVICE. NO OTHER ACTION NECESSARY. TRANSFERRED TO NON-MEL # 14SDR UIEA2021052301166Solenoid Valve · faultedAPU RELIABILITY COLD START UNSUCCESSFUL AFTER 3 ATTEMPTS ST -52C FL370. APU INOP.(<P>TRANSFERRED TO MDDR # 147412 IAW MEL 49-11-01A, CAT C, DUE DATE 02JUN21. EH 1526Z.</P><P>ONT MX, 23MAY, LP 1476796, ITEM M4: REMOVED AND REPLACED DE-OIL SOLENOID VALVE IAW AMMSDR UIEA2021052201164Warning Message · false activationINFO ONLY "L AFT FUEL PUMP" EICAS OCCURRED MOMENTARILY, NOT TRIGGERING AS MASTER CAUTION. (<P>PERFORMED OPERATONAL TEST OF THE L AFT FUEL PUMP/PRESSURE SWITCH IAW AMM 28-42-01, OPS NORMAL.</P>)SDR UIEA2021052401173Apu · faultedAPU COLD SOAK START FAILED 3 ATTEMPTS FL380, SAT-45(<P>OPS CHK APU PER AMM 49-11-00. CHK GOOD. NO FURTHER ACTION REQ AT THIS TIME.</P>)SDR UIEA2021042500990Starter · faultedAPU RELIABILITY COLD START ACCOMPLISHED ON FLT LEG ILN-ONT. SAT-59, FL 360. START UN-SUCCESSFUL ON 3 START ATTEMPTS.(<P>APU BITE SHOWS "A/C START CIRCUIT" FAULT FOR PREVIOUS 3 ATTEMPTS. FIM 49-11 FAULT TREE 962, FOUND SUSPECT TERMINALS AT APU START MOTOR AT BLSDR UIEA2021042600997Window · warning message"R SIDE WINDOW" EICAS MESSAGE DISPLAYED IN FLIGHT.(<P>PERF BITE TEST IAW FIM 30-41-803. RIGHT WINDOW #2 FAIL. SWAP WINDOW HEAT UNITS. TRANSFER TO MDDR 145886 PER MEL 30-41-01-02, CAT C, DUE 05MAY21 DISPATCH R.C. 18:21Z.</P><P>26 ARPR 21 - 1304706 - ITEM# M12 -SDR UIEA2021042300984Relay · failedAPU RELIABILITY COLD START UNSUCCESSFUL ON FLT ILN-PDX AFTER 3 START ATTEMPTS. STATUS MSG APU DOOR. NOTED BY MX. MULTIPLE APU STARTS ON GND NORMAL, 1ST ATTEMPT. APU INLET DOOR ACTUATOR CONNECTOR PLUG CLEAN & DRY, MOISTURE & FROST NOTED ON EMPENAGE. DMI 145628SDR UIEA2021042000938Contactor · failedAPU FAIL TO START(<P>TRANSFERRED TO MDDR 145605 IAW MEL 49-11-01A, CAT C.</P><P>LP 1312947: PERFORMED FIM 49-11 FT. 991 TO STEP 22. REMOVED AND REPLACED APU CRANK CONTACTOR K117 IAW AMM 49-41-05. OPS CHECKS GOOD. 3 SUCCESSFUL START ATTEMPTS. MDDR 145605 CLOSEDSDR UIEA2021041300883Radar · malfunctionedWX RADAR L & R SYS WILL NOT PAINT KNOWN PRECIPITATION.(<P>PERFORMED WXR BITE TEST IAW AMM 34-43 FAULT TREE 805 AND WEATHER RADAR ANTENNA TEST IAW AMM 34-43-05, NO FAULTS FOUND. OK TO CONTINUE.</P>)SDR UIEA2021041300882Radar · failedBTB L AND R WXR SYSTEM FAIL.(<P>RESTE C/B, PERFORMED TEST ON WXR IAW AMM 34-43-00, NO FAULT FOUND AT THIS TIME.</P>)SDR UIEA2021041000873Apu · malfunctionedAPU FAULT 1ST START ATTEMPT, 2ND ATTEMPT SUCCESSFUL FOLLOWED BY GEN OFF. RESET APU GEN FOLLOWED BY APU AUTO SHUTDOWN.(<P>TRANSFERRED TO MDDR 145104 PER DDG 49-11-01B. MX PROCEDURES C/W PLACARDS INSTALLED.</P><P>PDX MX, LP 1254482, ITEM M3: C/W FIM 49-11 FT 958SDR UIEA2021040900869Fan · inoperativeDURING PREFLIGHT MX AFT DET FAN, T/S PER FIM 26-16 FT 812, #1 FAN INOP.(<P>TRANSFERRED TO MEL 26-16-01-03-01, CAT C, MDDR 145049. DUE 19APR21 JT 05:26Z.</P><P>LP 1254413: REPLACED NBR 1 AFT CARGO SMOKE DET FAN IAW AMM 26-16-02. OPS CK GOOD.SDR UIEA2021040900866Warning Message · false activationAFT WQ EXH FAN 2 STATUS MSG(<P>RESET C/B ON PANEL P11, ROW P, COL 10 IAW 767 AMM 20-60-01-862-001. FAN TEST GOOD IAW B767 AMM 21-26-01-400-801-002, NO DEFECTS NOTED AT THIS TIME.</P>)SDR UIEA2021040900867Duct · damagedUPON INSPECTION OF #1 ENGINE FOUND A HOLE IN THE L/H SIDE LOW TURBINE COOLING DUCT.(<P>REMOVED AND REPLACED THE DUCT IAW GE CF6-80C2 ESM 72-00-04. PERFORMED IDLE LEAK CHECK IAW AMM 71-00-00-795-034-H03, TEST #3. LEAK AND OPS CHECK GOOD. ALL PARAMETERS NORMAL. SDR UIEA2021040600842Switch · faultedR ENGINE OIL PRESS LIGHT INOP(<P>TRANSFERRED TO MDDR # 144739 PER MEL 79-33-01-01 CAT C DUE 12 APR 21.</P><P>LOG PAGE 1145808: R&R KORREY SWITCH ASSEMBLY IAW SWPM 20-83-11, OPS CHECK GOOD. THIS CLOSES MDDR 144739.</P><P><BR /></P>)SDR UIEA2021040700843Duct · damagedON DESCENT L N2 VIB FLUCTUATED BETWEEN 2.7-5.0 FL 180-N1 APPROX 45%-IDLE 270KTS. NORMAL ENGINE INDICATIONS OTHERWISE(<P>T/S IAW 767 FIM TASK 71-05 FAULT TREE 858. FOUND LPT DUCT DAMAGE. </P><P>REF LP 1145806. REMOVED AND REPLACED THE DUCT IAW CF6-80C2 ESM 72-0SDR UIEA2021040700844Actuator · faultedAPU FAULT LIGHT APPEARED ON EICAS(<P>REMOVED AND REPLACED APU AIR INTAKE DOOR ACTUATOR IAW 767 AMM 49-15-06.OPS CHECK GOOD</P>)SDR UIEA2021040400833Control Panel · odorBURNING SMELL STRONG ON FLIGHT DECK DURING APPROACH AND LANDING(<P>PERFORMED INSPECTION REF AMM 21-00-21 NO SMELLS OF CONTAMINATION FOUND AT THIS TIME A/C OKAY FOR SERVICE REF AMM 05-51-56 FOR INSPECTION - FOUND ASSY 233N3214-28 TO BE INOP R/R PANEL IAW AMM 20SDR UIEA2021040600840Actuator · malfunctionedAPU COLD SOAK UNSUCCESSFUL AFTER 3 ATTEMPTS, APU DOOR STATUS MESSAGE.(<P>THIS CLOSES MDDR 144694.</P><P>LOG PAGE 1445793: APU HAS MESSAGE FOR DOOR SYSTEM. TRANSFERRED TO MDDR 144727 IAW MEL 49-11-01A.</P><P>LOG PAGE 1145807: REMOVED AND REPLACED APU AIR INTAKESDR UIEA2021040200786Unknown · unknownAPU COLD SOAK START UNSUCCESSFUL AFTER THREE ATTEMPTS.(<P>NOTED BY MX. PERFORMED OPS CHECK OF APU PER AMM 49-11-00. OPS CHECK GOOD. COLD SOAK START REQ PER MDDR 144694.</P>)SDR UIEA2021040200787Oil System · lowAPU RELIABILITY COLD START ACCOMPLISHED ONT-RFD SAT -59/ FL390/ START UNSUCCESSFUL/ 3 ATTEMPTS. ITEM #3: DURING THE 2ND APU START APU "OIL Q" WENT FROM FULL TO "0.25" IT SUBSEQUENTLY AKO DISPLAYED "ADD" TEMPORARILY.(<P>SERVICED APU OIL IAW AMM 12-00-00. TRANSFSDR UIEA2021032500708Warning Light · intermittentRH ENGINE OIL PRESSURE LIGHT OUT ( LOW ENG OIL PRESS INDICATION SYSTEM (-200/-300), ALL EXCEPT JT9D WITHOUT SB767-78-8 INSTALLED, AND CF6-80A/A2 WITHOUT SB767-78-8 INSTALLED )(<P>DEFERRED IAW DDG 79-33-01-01 PER MCC ST@ 2149Z. CAT "C" DUE DATE 03APR21. THIS OPSDR UIEA2021032200683Ecu · faultedL ENG CONTROL EICAS CAUTION & STATUS MSG AFTER ENGINE START(<P>PERFORMED PIMU BITE PER FIM 71-01-00/101, TEST OK. CLEARED EICAS MESSAGE. PERFORMED TWO ENG (L) RUNS PER AMM 71-00-00, CHECK OK. </P><P>LOG PAGE 1457801: REMOVED AND REPLACED LEFT ENG ELECTRONIC COSDR UIEA2021031000516Anti-Ice Valve · malfunctionedRIGHT ENGINE ANTI ICE VALVE LIGHT ILLUMINATED.(<P>TRANSFERRED TO MEL 30-21-01-04-02 CAT C MDDR 143629. DUE 20MAR21 MT PROCEDURES COMPLIED.</P><P>TPA MX, 13MAR, LP 1457787 ITEM M3: REMOVED AND REPLACED R/H ENG #2 THERMAL COWL ENG INLET ANTI-ICE VALVE AS PER AMMSDR UIEA2021031000514Seal · brokenFIRST AID KIT SEAL BROKEN(<P>REMOVED AND REPLACED FIRST AID KIT IAW AMM 25-64-03.</P>)SDR UIEA2021030800487Starter · inoperativeAPU RELIABILITY COLD START FLT LEG SCK-IAH SAT-62 FL410, START UNSUCCESSFUL AFTER 3 ATTEMPTS.(<P>REMOVED AND REPLACED APU STARTER DUE APU BITE TEST STARTER FAULT IAW AMM 49-41-01. OPS CHECK GOOD.</P>)SDR UIEA2021020100170Acoustic Panel · missingRIGHT ENGINE ACOUSTIC PANEL AFT OF FAN BLADES 6-8 O'CLOCK POSITION MISSING WIRE MESH PEELED OFF. TRANS TO NON-MEL 141743 AS PER AMM 72-00-00, CONTINUE IN OPERATION LIMIT TABLE 642. 10 FLIGHT CYCLES OR 100 FLIGHT HOURS. 04FEB, TPA, LP 1302921, ITEM 1: R & R SDR UIEA2021012600129Pressure Switch · failedRT AFT PRESSURE LIGHT INOPERABLE RT AFT BOOST PUMP. TRANSFERRED TO MDDR 141460, IAW MEL 28-42-01-01 CAT C, DUE DATE 05FEB21, MCC ERIC NOTIFIED. ALL PLACARDS INSTALLED. MX ACTION COMPLIED WITH. REMOVED AND REPLACED GFI RELAY POSITION K10702, PER AMM 28-22-SDR UIEA2021011900077Control Panel · malfunctionedRT AFT FUEL PUMP DOES NOT TURN OFF WITH SWITCH. TRANSFERRED TO MDDR 141101 CAT C DUE DATE 28 JAN 21, AS PER MEL 28-22-01. REMOVED AND REPLACED ENGINE FUEL FEED SYSTEM PANEL, IAW AMM 28-22-17. OPERATIONS CHECK GOOD AT THIS TIME, REF AMM 28-22-00. THIS CLEARSDR UIEA2021011400052Bulb · inoperativeRT ENGINE LOW OIL PRESS LIGHT INOPERABLE EICAS INDICATION NORMAL. LOW ENGINE OIL PRESS INDICATION SYSTEM (-200/-300), ALL EXCEPT JT9D WITHOUT SB767-78-8 INSTALLED, AND CF6-80A/A2 WITHOUT SB767-78-8 INSTALLED. TRANSFERRED TO MDDR 140889, IAW DDG 79-33-01-01 CSDR UIEA2020122402613Valve · malfunctionedFWD CABIN TEMP EICAS ILLUMINATED. ITEM TRANSFERRED TO MDDR 139966, PER MEL 21-61-01-02, CAT C, DUE 02JAN21, MCC NOTIFIED. REMOVED AND REPLACED FWD TRIM VALVE, IAW B767 AMM 21-61-07. OPERATIONS CHECKS GOOD AT THIS TIME.SDR UIEA2020120302509Switch · failedRIGHT AFT FUEL PUMP PRESSURE LIGHT NOT ILLUMINATED WITH SWITCH OFF, RIGHT AFT FUEL PUMP INOPERABLE. TRANSFERRED TO MDDR 138894, IAW MEL 28-22-01, CAT C. DUE DATE 13DEC20. REMOVED AND REPLACED AFT PUMP SWITCH ASSEMBLY, IAW AMM 33-13-00. OPERATIONS CHECK GOO
Back to N1373A