N14106
Service difficulty reports · 158
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N14106' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N14106' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2022071501737Intercostal · corrodedB757-53-3-0552: R/H MAIN CABIN FLOOR INTERCOSTAL LOCATED BETW ST A 365.25-377.7, RBL 59-63, UPPER SURFACE HAS CORROSION. AREA MAR KED IN RED. TRANSCRIBED FROM HAECO GSO NRC# 9283129 REMOVED AND REPLACED SEAT TRACK IAW BAC DWG 141N5131 AND SRM 51- 40-02 AND 51SDR CALA2022071501736Floor Support · corrodedSUPPORT TASK MAIN CABIN STA 720-724 RBL 65 GUTTER SUPPORT HAS CO RROSION ON UPPER SURFACE, TRANSCRIBED FROM HAECO GSO NR 9282390 REMOVED AND REPLACED GUTTER SUPPORT AT STA 720 TO 724 RBL-65 IAW B757-200 SRM 51-40-02, 51-40-05, DWG 143N5202. HAECO GSO MECH V 9SDR CALA2022071501735Floor Support · corrodedSUPPORT TASK L-1 DOOR THRESHOLD AREA STA 324-365 HAS CORROSION O N C-CHANNEL, TRANSCRIBED FROM HAECO GSO NR 9282881 REMOVED AND REPLACED C-CHANNEL IAW BAC 141N8322 AND SRM 51-40-02 , SRM 51-40-05. HAECO GSO MECH V901427 INSP QC456SDR CALA2022071101700Panel · corrodedSUPPORT TASK: MAIN CABIN STA 1660-1680 LBL65 HAS CORROSION ON UPPER SURFACE. TRANSCRIBED FROM HAECO GSO NRC 9282474SDR CALA2022071101699Deck Plate · corrodedSUPPORT TASK: MAIN CABIN STATION STA 1715-1720 DECK PLATE UPPER SURFACE HAS CORROSION AT AFT DRAIN PAN AREA. TRANSCRIBED FROM H AECO GSO N/R 9282689.SDR CALA2022071101698Deck Plate · gougedSUPPORT TASK: MAIN CABIN STA. 1680-1720 LBL 27 HAS GOUGES ON UPPER SURFACE AFT DECK PLATE. TRANSCRIBED FROM HAECO GSO NR 928234 71.SDR CALA2022071101693Floor Support · gougedSUPPORT TASK: 1602. MAIN CABIN STA. 668 & LBL20 FLOOR SUPPORT INTERCOSTAL HAS GOUGES ON TOP @ FASTENER HOLE. DOT J203. TRANSCRIBED FROM HAECO GSO N/R 9282541.SDR CALA2022071101692Deck Plate · gougedSUPPORT TASK: MAIN CABIN STA. 1680-1720 RBL 27 HAS GOUGES ON UPPER SURFACE AFT DECK PLATE. TRANSCRIBED FROM HAECO GSO N/R 928 2472.SDR CALA2022071101691Floor Support · corroded(B757-53-3-0531) R4 CUTOUT LOWER SILL, CHANNEL, CORRODED BETWEEN BS 1660 AND BS 1680 APPROX. STRINGER S-17R. MARKED. DOT: B880 TRANSCRIBED FROM HAECO GSO NR 9283260.SDR CALA2022070801669Intercostal · corrodedSUPPORT TASK: MAIN CABIN STA 324-345 LBL20 INTERCOSTAL HAS CORROSION ON UPPER SURFACE. TRANSCRIBED FROM HAECO GSO NRC 9282558 REPLACED INTERCOSTAL FR 324-345 PT # 141N5170U30 IAW BOEING DWG 141N5170 REV C AND B757-200 SRM 51-40-02. CREATED SDR #1028967 DOT ZSDR CALA2022070801668Crease Beam · corrodedB757-53-3-0552 RH MAIN CABIN CREASE BEAM FLOOR STRUCTURE UPPER SURFACE STA. 429-440 APPROX. HAS NUMEROUS SPOTS OF CORROSION. AREA MARKED IN RED, TRANSCRIBED FROM HAECO GSO NR 9283103 REMOVED CORROSION ON CREASE BEAM FOUND TO BE OUT OF LIMITS WITH CREASE BEAM ISDR CALA2022070801682Angle · corrodedSUPPORT TASK: MAIN CABIN STA. 1678 RBL 65 ANGLE UPPER SURFACE HAS CORROSION. TRANSCRIBED FROM HAECO GSO NR 9282486. REMOVED CLIP FROM R4 THRESHOLD SUPPORT BEAM AT RBL65 STA 1681.8 LOCATED AND DRILLED NEW CLIP IAW B757-200 SRM 51-40-05 AND B757- HAECO GSO MECHSDR CALA2022070801666Floor Support · corrodedB757-53-3-0056 LH MAIN CABIN FLOOR INTERCOSTAL LOCATED AT STA 707 LBL62 UPPER SURFACE HAS AREA OF CORROSION NEAR FASTENER HOLE. AREA CIRCLED IN RED, TRANSCRIBED FROM HAECO GSO NR 9283130 REMOVED CORROSION, ORIG. THICKNESS: .065" IAW BOEING DWG #143N54 # 143N54SDR CALA2022070801677Floor Support · corrodedSUPPORT TASK- MAIN CABIN STA 1640-1660 BL0 FLOOR SUPPORT HAS COR ROSION ON UPPER SURFACE. TRANSCRIBED FROM HAECO GSO NRC 9282478 REMOVED CORROSION ON INTERCOSTAL FLOOR SUPPORT AT STA IAW B757-200 SRM 51-40-02 AND BAC DWG 146N5269-1 REV- 1640-STA 1660 BL-O. FOSDR CALA2022070801676Housing · corrodedB757-53-3-0479: BS 333 LH CORROSION AROUND FLIGHT CONTROL CABLE HOUSING. TRANSCRIBED FROM HAECO GSO NRC 9282788 MAT ID 7075.0 .040 PN 141N5170-13 PO 973010.1, FAB''D AND INSTALLED IAW B757 200 SRM 51-40-02 AND BOEING DWG 141M5170 IAW BOEING DWG 14145170 REV SDR CALA2022070801667Floor Support · corrodedSUPPORT TASK: MAIN CABIN FLOOR SUPPORT AT STA 340 LBL20-LBL32 HA S CORROSION ON UPPER SURFACE. TRANSCRIBED FROM HAECO GSO NRC 92 82960. INSTALLED FLOOR SUPPORT STA 340 LBL 20-32 IAW BOEING DWG 141N5170 REV C AND B757 200 SRM 51-40-02. HAECO GSO MECH V932595 ISDR CALA2022070801665Intercostal · corrodedSUPPORT TASK: MAIN CABIN STA 1660-1680 BL0 FLOOR SUPPORT HAS COR ROSION ON UPPER SURFACE. TRANSCRIBED FROM HAECO GSO NRC 9282477 IAW B757-200 DWG 146N5230 AND B757-200 SRM 51-40-02 AND LOCATING AND DRILL NEW HOLES IAW B757-200 SRM 51-40-05 REMOVED CORROSION ASDR CALA2022070801664Intercostal · corrodedSUPPORT TASK: MAIN CABIN STA 1660-1680 BL0 FLOOR SUPPORT HAS COR ROSION ON UPPER SURFACE. TRANSCRIBED FROM HAECO GSO NRC 9282477 IAW B757-200 DWG 146N5230 AND B757-200 SRM 51-40-02 AND LOCATING AND DRILL NEW HOLES IAW B757-200 SRM 51-40-05 REMOVED CORROSION ASDR CALA2022070401638Support Beam · corrodedB757-53-3-0572 R-4 DOOR THRESHOLD SUPPORT BEAM UPPER SIDE CORRODED APPROX 6 INCHES IN FRONT OF AFT DRAIN LINE CUTOUT. TRANSCRIBED FROM HAECO GSO NRC 9282803SDR CALA2022070401637Floor Support · corrodedSUPPORT TASK: 1602 MAIN CABIN STA 650 RBL25 FLOOR SUPPORT HAS CORROSION. TRANSCRIBED FROM HAECO GSO NRC 9282540SDR CALA2022070401635Intercostal · corrodedSUPPORT TASK: MAIN CABIN STA 324-345 LBL20 INTERCOSTAL HAS CORROSION ON UPPER SURFACE. TRANSCRIBED FROM HAECO GSO NRC 9282558SDR CALA2022062801597Floor Support · corrodedSUPPORT TASK: MAIN CABIN STA 300 RBL 18-34 INTERCOSTAL HAS CORROSION ON UPPER SURFACE. TRANSCRIBED FROM HAECO GSO NRC 9282557 REMOVED AND INSTALLED NEW SUPPORT IAW BAC DWG 141N5160 AND SRM 5 1-40-02, SRM 51-40-05. CREATED SDR #1028928. HAECO GSO MECH V9 014SDR CALA2022062201548Floor Support · corrodedSUPPORT TASK- 1602 MAIN CABIN FLOOR PANEL SUPPORT HAS CORROSION STA 740-750 RBL62. TRANSCRIBED FROM HAECO GSO NRC 9282535 INSTALLED CREASE BEAM INBOARD SPLICE REPAIR IAW B757-200 SRM 53- 00-13-2R-1. HAECO GSO MECH V890956 INSP QC302SDR CALA2022032300759None · noneLAV M FUL AND OVER FLOWN. FOUND LAV M PREVIOUSLY LOCKED OUT, LAV K WAS FULL, ALL LAVS SERVICED AND CLEANED BY CLEANERS . OK FOR SERVICE.SDR CALA2021072601193Radio · inoperativeHF RADIOS TRANSMIT NO RECEIVE..NO STATIC AT ALL...NO SIDE TONE ON RIGHT HF AT ALL R HF TRANSCEIVER R&R PER AMM 23-11-03-401 & TEST PASS. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1615423 SN OFF 6630 TRANSCEIVER, HF OFF 99-2310-9-0001 6630 ON 29-2311-9-001SDR CALA2021052600742Line · leakingRH MLG TRUCK POSITIONER ACTUALTOR PRESSURE HYDRAULIC FLEX LINE LEAKING. REMOVED AND REPLACED RH MLG TRUCK POSITION ACTUATOR UPPER PRESS HYD FLEX LINE. HYD SERVICE AND LEAK CHECK REQUIRED. SERVICED LEFT SYSTEM HYDRAULICS, LEAK TEST OF INSTALLED LINE GOOD. PERFOSDR CALA2021022500227Charger · inoperativeDURING SCHK FOUND SEAT EMERGENCY LIGHTS INOP FROM SEAT 21-33. R & R CHARGER ASSY M10699 IAW AMM 33-51-07 OPS CHK GOOD INSPECTED INSTALL AND TEST.SDR CALA2019071801217Not Reported · leakingB757-53-3-0480, FWD CARGO STA 680 LT SIDE UNDER LAVS FLOORBEAM HAS BLUE WATER STAINS. REF ST ENG N/R 0066860 FABRICATED 15 EA INSOLATION BLANKETS FOR FWD CARGO COMPARTMENT STA 680 LT SIDE UNDER LAVS FLOORBEAM IAW AMM 25-00-00-300 -810. REMOVED CONTAMINATED INSSDR CALA2019071801215Frame · dentedB757-06-03-0230, FWD CARGO FRAME FLANGE DENTED AT STA540 LT STRINGER. REF ST-ENG N/R 0066885. ACCOMPLISHED INTERIM REPAIR AT FWD CARGO FRAME STA 540 BETWEEN S TGR 23L AND STGR 24L IAW EC/RA 5310-07642, REV -, PART 1. WORK WAS ACCOMPLISHED ON ST-ENG N/R 0066885SDR CALA2019071301175Slider · defectiveSUPPORT TASK EA 2560-02123 REV D DOOR AFT GIRT BAR SLIDER FAILED MEASUREMENT TEST. REF ST-ENG N/R 0066591.SDR CALA2019070801165Slider · defectiveEA 2560-02123 REV D R1 DOOR FWD AND AFT GIRT BAR SLIDER FAILED MEASUREMENT TEST. REF ST-ENG N/R 0066590SDR CALA2019070801155Support Bracket · crackedB757-06-3-0354-FWD CARGO DOOR FWD AND AFT UPPER CORNER SUPPORT BRACKETS ARE CRACKED AS MARKED. 50-022. REF. ST. ENGINEERING N/R 0066721 REMOVED AND REPLACED FWD CARGO DOOR FWD AND AFT UPPER CORNER BRA CKETS IAW SRM 51-40-02 PG 10 AND DWG 143N6603 RE V AT. THISSDR CALA2019070801151Pan · gouged(B757-06-3-0366)L4 DOOR EXTERNAL HANDLE PAN IS GOUGED AS MARKED 50-036 REF. ST.ENGINEERING N/R 0066795 L4 DOOR EXT. HANDLE PAN FOUND TO BE OUT OF LIMITS IAW SRM 52-10-01 ALLOW DAMAGE 1, FIG.101, DET. VI. (DIMENSIONS ARE: L =4.8 X W =.10" X D=.020"). REPLACED/ISDR CALA2019022500296Control Panel · failedR ENG BLEED TRIP AT FL390... EVEN AFTER DESCEST TO FL250 UNABLE TO HOLD CAB PER TOMC AND ORDMM TECH CALLOUT ACCOMPLISH PNUEMATIC SYSTEM HEAL TH CHECK PER MM36-00-23-501 ON #2 ENGINE. ACP HPSOV AND HS PILO T TEST PER MM36-00-23-705-151-001, TEST PASSED. ACP SDR CALA2017120804354Light · unknownEMERGENCY LIGHTS WITH OVHD PNL SW IN ARMED POS, UNARMED LIGHT ON AND MSG DISPLAYED PERFORMED OPERATIONAL TEST PER MM33-51-00-715-044. ALL SWITCH POSITIONS CHECKED GOOD PER THE MM. OK TO CONTINUE.SDR CALA2017082502883Lamp · inoperativeEMERGENCY LIGHT ABOVE SEAT 1B INOPERATIVE. REPLACED THE LAMPS. OPS CHECKED GOOD.SDR CALA2017050501274Switch · brokenEMERGENCY LIGHT TEST SWITCH NEXT TO L2 DOOR BROKEN. REPLACED FLIGHT COMPARTMENT EMERGENCY LIGHT ABOVE L2 DOOR IAW AMM 33-51-09. OPS CHECK GOOD.SDR CALA2017041401003Light · inoperativeL3 EMERGENCY EXTERIOR LIGHT INOP. RELAMPED L3 EXTERIOR EMERGENCY LIGHT. OPS CHECK GOOD. REF AMM 33-51-00-715-039.SDR CALA2017041401002Light · inoperativeL2 EMERGENCY EXTERIOR LIGHT INOP. RELAMPED L2 EXTERIOR EMERGENCY LIGHT. OPS CHECK GOOD. REF AMM 33-51-00-715-039.SDR CALA2017013000206Battery · dischargedPER 2 SVC FOUND EXTERIOR EMERGENCY LIGHT INOP BY MED 2R, 4R & 4L. RELAMPED 2R AND 4L OPS CK GOOD. DISASSEMBLED 4R FOR TS LIGHT INOP FOUND BATTERY TO BE BAD. REPLACED BATTERY AND TESTED. OPS CHECKS GOOD. REF AMM 33-51-07-902-001 REASSEMBLED 4R EXTERIOR EMERGENCSDR CALA2017012200151Seal · tornEXTREMELY LOUD HIGH PITCH SQUEAL PASSING THROUGH 16000. CONTINUED TO FL190. ON DESCENT STOPPED PASSING THRU FL160. EMERGENCY DECLARED. REPLACED CAPTAIN SLIDING WINDOW SEAL.SDR CALA2016122201155Lamp · inoperativeFOUND R2 & L4 DOOR EXTERIOR EMERGENCY SLIDE LIGHTS OUT. REPLACED THE LAMPS. OPS OK.SDR CALA2016070500406Frame · damagedFRAME DENTED BS 1480, STR 25-26L CUTOUT DAMAGED AREA BETWEEN STR 25-26L, FUSELAGE LOWER LOBE FRAME REPAIR AT STA 1480 BETWEEN STR 23- 26L REF SRM 53-00-07, FIG 201, REP 5, CAT B REPAIR. INSP THRESHOLD 37500, F/C AFT REPAIR AND REPEAT AT 12 000 F/C INTERVALS.SDR CALA2016070500404Crease Beam · corrodedLBL 70, CREASEBEAM, BS 760 CORRODED, REMOVED DAMAGE SECTION OF CREASEBEAM STA 735-STA 765. INSTALLED REPAIR REF SRM 53-00-13, FIG 201, REPAIR 1.SDR CALA2016070500403Skin · dentedEXISTING DENT FWD OF L-2 DOOR BETWEEN STA 620 AND STA 640 BETWEEN STR 17L AND STR 18L. INSTALLED FUSELAGE PARTIAL SKIN REPLACEMENT STA 570-661, STR 14L-19L REF RES WI NR 2010609-16 AND ECRA NR 5330-057-36. THIS IS A PERMANENT REPAIR WITH REQUIRED INSPECTIONSSDR CALA2015122101016Unknown · odorBURNING RUBBER ODOR IN COCKPIT AFTER ENG START, AS TAXING OUT SEEMED TO DISSIPATE. AS ACFT TOOK RUNWAY FOR TAKEOFF, ODOR CAME BACK VERY STRONG, AGAIN IT SMELLED LIKE BURNING RUBBER. PERFORMED CONDITIONAL INSPECTION FOR SMOKE & ODOR IAW AMM 05-51-58. NO ODOSDR CALA2015082700700Hydraulic Line · failedINFLIGHT LT HYD QTY LIGHT ILLUMINATED, FOLLOWED BY RESERVOIR LIGHT. HYD QTY READ ZERO, ENG HYD PUMP TURNED OFF WITHIN 3 MINUTES. ELEC HYD PUMP TURNED OFF WITHIN 5 MIN. R & R DAMAGED LT MLG DOWNLOCK RETURN LINE IAW CHAPTER 20. SERVICED THE LT HYD SYS RESERVSDR CALA2015040600245Sensor · out of adjustLEFT CTR DOOR LIGHT ILLUMINATED AT +60KTS ON TAKEOFF. RTO PERFORMED, FOUND L2 DOOR TO OPERATE NORMAL & INDICATION INTERMITTENT. PLACARDED L2 DOOR INDICATION LIGHT INOPERATIVE IAW MEL. DDP COMPLIED WITH. VERIFIED DOOR CLOSED PRIOR TO DEPARTURE. TROUBLE SHOSDR CALA2014112501478Skin · corrodedDURING WALK AROUND FOUND CORROSION AT FWD LAVATORY SERVICE DOOR CUT OUT, AFT INBD AREA. REPAIRED IAW ECRA 5331-01984 PART 1. ISSUE A DIP TO READ ACCOMPLISH A PERMANENT REPAIR IAW PART 3 OF ECRA 5331-01984 PRIOR TO NOVEMBER 21, 2016 OR BEFORE 21,932 TOTAL FLISDR CALA2014102701397Receptacle · burnedFIRST OFFICER REPORTS SCORCH MARKS AROUND ELEC OUTLET AT 4L. R & R OUTLET AT 4L. OPERATIONS CHECKED OK IAW WDM 25-29-11.
Back to N14106