N1427A
Service difficulty reports · 457
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1427A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1427A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2020012400117Wire · looseLEFT ENG BLEED EICAS MSG DISPLAYED WHEN LEFT ENG ANTI-ICE SELECTED.(<P>PERFORMED BITE CHECK FOR FAMV, FOUND L FAV, FAS LIGHT ON. OPENED T/R ON LEFT ENG AND FOUND TWO LOOSE WIRES. TIGHTENED WIRES, RAN ENG, NO MESSAGES PRESENT AT THIS TIME. VERIFIED BITE ON FAMVSDR UIEA2020012400118Warning Message · false activationLEFT ANTI-ICE VALVE EICAS MSG WHEN SELECTED ENG ANTI-ICE FROM ON TO AUTO.(<P>PERFORMED ANTI-ICE VALVE OPS CHK IAW 30-21-00. NO PROBLEMS NOTED.</P>)SDR UIEA2020012100100Circuit Card · malfunctionedLEFT ENGINE BLEED OFF CAUTION MESSAGE ON EICAS. BITE PROCEDURE PERFORMED, FOUND FAS AND FAU FAULTS. REMOVED AND REPLACED LEFT ENGINE AIR SUPPLY CONTROL IAW AMM 36-11-03. FAULTS CLEARED. MCC NOTIFIED.SDR UIEA2020012190095Seal · leakingAFTER BOTH ENGINES WERE STARTED AND WITH AIRCRAFT CONFIGURED NORMALLY, THE LEFT DUCT PRESSURE WOULD OSCILLATE BETWEEN 10 AND 40 PSI WHILE RIGHT DUCT PRESSURE WAS STEADY AT 35 PSI. THE OSCILLATION TOOK APPROX 20 SECONDS FROM 10 TO 40 PSI THEN REMAINED AT 40 FORSDR UIEA2020011700082Pump · malfunctionedDURING T/O, CENTER HYD DEM PUMP EICAS MSG, C HYD SYS PRESS, GEAR DISAGREE AT APPROX 2000FT. AFTER GEAR RETRACTED, ONLY C HYD DEM PUMP REMAINED ON. QRH COMPLETED CALLING FOR PUMP TO BE TURNED OFF. T/S TO CENTER HYD DEMAND PUMP. TRANSFER TO MDDR 123516 IAW MEL 2SDR UIEA2020010900042Warning System · false activationSTATUS MESSAGE AFT EQUIPMENT EXH FAN 2.(<P>PERFORMED FIM 21-26 TASK 806. NO FAULTS FOUND.</P>)SDR UIEA2020010900043Warning System · false activationHI FLOW INHIBIT STATUS MESSAGE.(<P>PERFORMED FIM 21-51 FAULT TREE 854. NO FAULTS NOTED. </P>)SDR UIEA2020010600020Start Valve · malfunctionedAPU INSUFFICIENT DUCT PRESSURE(<P>ITEM TRANSFERRED TO MDDR 123039 IAW DDG 49-11-01-01, CAT 'C'.</P><P>REF LOG PAGE 1178031: FOUND INSUFFICIENT AIR FLOW IN LH STARTER, REMOVED AND REPLACED LEFT ENG STARTER (OFF PART: P/N 3505448-5-1, S/N GRTA0349) AND START VALSDR UIEA2019122306129Acoustic Liner · damagedON WALKAROUND FOUND RT ENG ACOUSTIC PANEL AT APPROX. 07 O'CLOCK POSITION AFT OF N1 FAN, TOP COAT MISSING. REMOVED AND REPLACED NR 2 ENGINE ACOUSTIC LINER PANEL AT 7 O'CLOCK IAW AMM 72-33-01.SDR UIEA2019122206122Warning Message · false activationLEFT ENGINE ANTI-ICE EICAS MESSAGE ILLUMINATED DURING DESCENT. CYCLED THE SWITCH AND THE MESSAGE WENT AWAY. PERFORMED ENGINE INLET TAI TEST IAW AMM 30-21-00. OPS CHECKED GOOD.SDR UIEA2019122306115Warning Message · false activationSTATUS MESSAGE FOR AFT EQUIP EXHAUST FAN NR 2. ACCOMPLISHED FIM TASK 21-26 FT 806. MESSAGE CLEARED. OPS CHECKED NORMAL.SDR UIEA2019122096113Warning Message · false activationSTATUS MSG AFT EQUIPMENT EXH FAN 2(<P>PERFORMED FIM 21-26 FT 806, MSG ERASED. OPS CHK NORMAL AT THIS TIME.</P>)SDR UIEA2019121986107Sensor · failedRH PACK PRIMARY HEAT EXCHANGER IN TEMP INDICATOR IS BLANK.(<P>REMOVED AND REPLACED BULB ASSY IAW AMM 21-61-02. OPS CHK NORMAL.</P>)SDR UIEA2019121306066Duct · damagedFOUND SURGE VALVE DUCT DAMAGED.(<P>REMOVED AND REPLACED DUCT IAW B767 AMM 49-53-01, OPS CHECK GOOD. <BR /></P>)SDR UIEA2019121326064Warning Message · illuminatedON THE CLIMB, L/H ENG DISPLAYED 3.5 VIB FAN AT CLIMB POWER (104.1). EVENT RECORD WAS PUSHED. (<P>PERFORMED FIM 71-05 FT 853 UP TO BLOCK 56. CONTINUE THE ENGINE TO SERVICE, MONITOR THE ENG VIB ON SUBSEQUENT FLIGHTS. MCC NOTIFIED.</P>)SDR UIEA2019121326056Warning Message · false activation"R BLEED OFF" MSG DISPLAYED & CLEARED NUMEROUS TIMES DURING FLIGHT.(<P>PERFORMED AIR SUPPLY MODULE BITE TEST, NO FAULT FOUND PER FIM 36-10 FT 836. IDLE ENG RUN UP IAW 71-00-00-862-002-600, OPS CHECK NORMAL.</P>)SDR UIEA2019120435991Module · failedAPU NOT PROVIDING ENOUGH AIR PRESSURE TO START RIGHT ENGINE. REMOVED AND REPLACED FLOW SENSING MODULE IAW B767 AMM 49-53-08. OPS CHECKED GOOD.SDR UIEA2019120295964O-Ring · damagedDURING MAINTENANCE ON APU, EVIDENCE OF OIL LEAK FROM FILLER CAP. FOUND FILLER CAP "O" RING DAMAGED.(<P>REMOVED AND REPLACED FILLER CAP "O" RING IAW AMM 20-10-19. RAN APU AND CHECKED FOR OIL LEAKS, NO LEAKS NOTED AT THIS TIME.</P>)SDR UIEA2019120205973Engine · malfunctionedUNCOMMANDED CHANGES IN THE NR 1 ENGINE N1, N2 FUEL FLOW DURING POWER SURGES FROM BAD CPU. NO THRUST LEVER MOVEMENT. PERFORMED PIMU BITE PROCEDURE AND GROUND TEST ON BOTH ENGINES BY PLACING EEC MAINT (L/R) ENGINES POWER SWITCH ON P61 PANEL TO TEST PER FIM 71-0SDR UIEA2019112535951Sensor · faultedAPU AUTO SHUTDOWN. SERVICED APU OIL (1.5 QT) IAW AMM 12-13-04. OPS CHECK AND LEAK CHECK NORMAL, NO FAULTS NOTED. APU AUTO SHUTDOWN AGAIN. REMOVED AND REPLACED INLET TEMP SENSOR ON APU PER AMM 49-61-03. RAN APU, PERFORMED OPERATIONAL CHECK, OPS CHECK GOOSDR UIEA2019112195934None · noneRADAR GROUND CLUTTER SUPPRESSION (GCS) SWITCH DOES NOT LOCK DOWN IN THE GROUND CLUTTER SUPPRESSION MODE. ALL MODES APPEAR TO OPERATE ON THE RADAR DISPLAY.(<P>THIS IS NON-LATCHING COMPONENT IAW S/B 34-45-32, PN 622-5130-005. PERFORMED OPS CHECK OF THE WX RADAR SDR UIEA2019111435901Pump · warning messageL FWD FUEL PUMP EICAS MESSAGE.(<P>PLACED ON DMI 120572 IAW MEL 28-22-01, CAT 'C', DUE DATE: 23-NOV-19.</P><P>REF LOG PAGE 1232423 ITEM M3: REMOVED AND REPLACED LEFT FWD BOOST PUMP IAW B767 AMM 28-22-03. OPS CHECK GOOD. THIS CLEARS MDDR 120572. PLACARDS REMOVEDSDR UIEA2019110505853Oxygen Mask · damagedPORTABLE MASK RUBBER CRACKED.(<P>REMOVED AND REPLACED PORTABLE O2 MASK IAW LOPA DRAWING #B767F 25-EEL REV 11. OPS CHK NORMAL AT THIS TIME. </P>)SDR UIEA2019103005819Unknown · malfunctionedAPU INOP; LOW DUCT PRESSURE.(<P>TRANSFERRED TO MDDR 119894 IAW MEL 49-11-01A, CAT 'C', DUE DATE 09-NOV-19.</P><P>LP 1075747 - M9: PERFORMED APU BITE TEST IAW AMM 49-61-05. NO FAULTS DISPLAYED ON ANY OF THE LEGS. PERFORMED AIR SUPPLY BITE IAW 36-23-01, NO FAULTSDR UIEA2019102545787Apu · unknownAPU SHUTDOWN WHEN SWITCHING FROM EXT PWR TO APU GEN.(<P>PERFORMED APU BITE IAW B767 FIM 49-11 FT 987. NO FAULTS OR ABNORMAL SHUTDOWN ECU. STARTED APU IAW B767 AMM 49-11-00. PERFORMED POWER TRANSFER AND OPS CHK OF APU GENERATOR IAW B767 AMM 24-21-00, OPS CHECK SDR UIEA2019102205774Sense Line · unsecureLEFT ENGINE BLEED OFF INTERMITTENT.(<P>SECURED PRSOV SENSE LINES AND EXERCISED PRSOV VALVE. NO DEFECTS NOTED AT THIS TIME PER FIM 36-11-07. </P>)SDR UIEA2019100135613Circuit Breaker · trippedL FWD FUEL BOOST PUMP CIRCUIT BREAKER POPPED AFTER TURNING FUEL PUMPS ON (<P>RESET CIRCUIT BREAKER AND OPS CHECKED FUEL PUMP I.A.W AMM 28-21-00 NO FAULTS AT THIS TIME </P>)SDR UIEA2019100105592Fire Warning · false activationMAIN CARGO FIRE EICAS MESSAGE WITH FIRE WARMING LIGHT, AND MASTER CAUTION LIGHT AND CARGO FIRE ARM SWITCH LIGHT DEPRESSED MAIN CARGO FIRE ARM SWITCH AND INCORRECTLY DISCHARGED APU FIRE BOTTLE. REMOVED AND REPLACED APU FIRE EXTINGUISHER IAW AMM 26-22-02.SDR UIEA2019091805526Control Valve · malfunctionedVERY LOW DUCT PRESSURE DURING FIRST ENGINE START (RIGHT ENGINE), LONGER THAN NORMAL START PROCESS. TRANSFERRED TO MDDR 117914 IAW MEL 49-11-01-01, CAT "C", DUE 28-SEP-2019. MAINT ACTION C/W. LP 1210156 - M6: REMOVED AND REPLACED THE APU AIR SUPPLY SHUTOFF VALVSDR UIEA2019091205486Fire Detector · faultyRIGHT ENG #2 FIRE LOOP EICAS MSG. TRANSFERRED TO MDDR #117634 IAW MEL 26-11-01-01, CAT "C", DUE 22-SEP-19. DISPATCH: DL @ 09:36Z LP 1210141- M4: REMOVED AND REPLACED LOWER AFT FIRE DETECTOR ON RT ENGINE IAW AMM 26-11-02, OPS CHECK GOOD. THIS CLEARS DMI #117634SDR UIEA2019091205487Pump · malfunctionedDURING R ENG START, APU DUCT PRESSURE STARTED FLUCTUATING BETWEEN 15 - 30%. R ENG STARTER MESSAGE DISPLAYED @ APPROX 5% N2. TRANSFERRED TO MDDR # 117639 IAW MEL 49-11-01A, CAT C. DUE 22SEP19. DISP: ZH 10:45Z. LP 1086521 - M1: PRESSURIZED PNEU SYS IAW AMM 36-00SDR UIEA2019083105409Valve · misinstalledDURING APPROACH, LEFT PACK TEMP EICAS MESSAGE. PACK OPERATED IN STANDBY MODE AFTER PACK RESET. TRANSFERRED TO MDDR 117124 PER MEL 21-51-03-01, CAT C, DUE 10-SEP-19. PLACARDS INSTALLED AND MCC NOTIFIED. LP 1073215 - M3: T/S PACK CONTROL SYSTEM AND FOUND TRIM AISDR UIEA2019083105410Tru · faultyAPU FAILED TO START, APU FAULT MESSAGE. TRANSFERRED TO MDDR 117125 IAW MEL 49-11-01A, CAT 'C', DUE 10-SEP-19. LP 1073215 - M2: T/S PER FIM TASK 49-11 FAULT TREE 991, FOUND FAULTY APU TRU. REMOVED AND REPLACED APU TRU IAW AMM 24-32-04. OPS CHECK GOOD, NO FAULTSSDR UIEA2019083105411Warning System · false activationRIGHT FWD WINDOW EICAS MESSAGE DURING APU START ATTEMPT. PERFORMED OPS CHECK IAW AMM 30-41-00, OPS CHECKS GOOD AT THIS TIME.SDR UIEA2019083105407Warning System · false activationRT FWD WINDOW EICAS MESSAGE UPON LANDING. PERFORMED OPS CHECK IAW AMM 30-41-00. OPS CHECKED GOOD AT THIS TIME.SDR UIEA2019083105408Unknown · malfunctionedAPU FAILED TO START UPON LANDING AT RFD. SECOND ATTEMPT FAILED AS WELL WITH "APU FAULT" EICAS MESSAGE. PERFORMED BITE TEST IAW FIM 49-11 FAULT TREE 958. NO FAULTS FOUND AT THIS TIME.SDR UIEA2019083005393Unknown · malfunctionedAPU FAILED TO START ONCE A/C LANDED IN ONT. PERFORMED FIM 49-11 FT 987 APU BITE, FLAG 34 FAULT. CLEARED FAULT AND PERFORMED OPS CHECK. OPS CHECK NORMAL AT THIS TIME IAW AMM 49-11-00.SDR UIEA2019083095328Warning Message · false activationLEFT PACK TEMP EICAS MESSAGE IN FLIGHT. PERFORMED LEFT PACK SYSTEM BITE AND PACK SYSTEM TEST IAW AMM 21-51-00, NO FAULTS FOUND. RECYCLED LEFT PACK SWITCH, OPS CHECK GOOD.SDR UIEA2019082805310Wire · disconnectedRT FWD WINDOW HEAT EICAS MESSAGE AND INOP LIGHT ON OVERHEAD PANEL CAME ON AFTER LANDING. DURING TROUBLESHOOTING, FOUND 2 SHIELDED WIRES FROM TERMINAL BOARD T234, FA2 AND FC2 NOT CONNECTED FOR WIRES W624-203B AND W624-202R. RESOLDERED IAW SWPM 20-10-15. PERFORSDR UIEA2019082765294Status Message · false indicationDURING PRE-FLIGHT CHECK, FOUND STATUS MESSAGE: R ENG FIRE LP 2. T/S PER FIM 26-11. CHECKED AND CLEANED ALL CONNECTORS, NO FAULTS NOTED. ALL CHECKED OK, TESTED FIRE DETECTOR LOOPS AND ALL CHECK OK PER AMM 26-11-00.SDR UIEA2019082705302Warning Message · false activationRIGHT FWD WINDOW EICAS MESSAGE CAME ON AFTER LANDING. RESET RIGHT FWD WINDOW HEAT PBSW, FAULT CLEARED. PERFORMED FIM 30-41 FT 804, NO FAULT NOTED.SDR UIEA2019082765295Controller · no testR FWD AND L AFT WINDOW HEAT CONTROLLER REQUIRES REPLACEMENT, WILL NOT TEST CONSISTENTLY. REMOVED AND INSTALLED. SERVICEABLE WINDOW HEAT CONTROLLER IAW B767 AMM 30-41-01. OPS CHECK GOOD.SDR UIEA2019082705304Wire · shortedEICAS MESSAGE FOR RT FWD WINDOW. RAN QRH 3.15. PERFORMED FIM 30-41 FT 802. CHECKED SENSOR 1 SENSOR 2 OHMS GOOD. CHECKED WINDOW HEAT ELEMENT RESISTANCE AT 10.2 OHMS GOOD, FOUND SHORT TO GROUND ON WIRE W624-202B-24 W624-203B-24, W624-215B-24. ITEM 3. ITEM 3SDR UIEA2019082765292Controller · not reportedRH PACK CONTROLLER REQUIRES REPLACEMENT. REMOVED AND REPLACED RH PACK CONTROLLER IAW AMM 21-51-24. OPS CHECK GOOD AT THIS TIME.SDR UIEA2019082765290Warning Message · false activationDURING DESCENT RECEIVED AN EICAS MESSAGE, LT PACK TEMP. RAN THE QRH TO SBY N. PERFORMED SYSTEM TEST OF LT PACK COOLING SYSTEM IAW B767 AMM 21-51-00. FOUND NO MESSAGES OR FAULTS ON LT PACK CONTROLLER AT THIS TIME. AIRCRAFT OK FOR SERVICE.SDR UIEA2019082505283Controller · malfunctionedRECEIVED "RIGHT FWD WINDOW" EICAS AFTER LANDING. REMOVED AND REPLACED RIGHT WINDOW HEAT CONTROLLER IAW AMM 30-41-01. OPS CHECK GOOD.SDR UIEA2019082655278Warning Message · false activationRT FWD WINDOW EICAS MSG. PERFORMED FWD WINDOW HEAT OPERATIONAL CHECK IAW AMM 30-41-00. FOUND NO DISCREPANCY AT THIS TIME, OPS CHECK IAW FIM 30-41-00 FAULT TREE 804.</P>)SDR UIEA2019082645276Warning Message · false activationEICAS MESSAGE: RIGHT FWD WINDOW. PERFORMED OPS CHECK OF THE RIGHT FWD WINDOW HEAT IAW AMM 30-41-00. OPS CHECK GOOD AT THIS TIME.SDR UIEA2019082635266Warning Message · false activationR FWD WINDOW EICAS MESSAGE. PERFORMED OPS CHECK OF RT FWD WINDOW HEAT, OPS CHECK GOOD AT THIS TIME IAW AMM 30-41-01.SDR UIEA2019082635272Apu · inoperativeAPU INOP. PERFORMED OPERATIONAL CHECK OF APU IAW AMM 49-11-00, OPS CHECK GOOD.
Back to N1427A