N17138
Service difficulty reports · 148
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N17138' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N17138' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20260728018Lamp · burned outAFT AISLE EMERGENCY LIGHT BURNED OUT. REMOVED AND REPLACED AFT AISLE EMERGENCY LIGHT LAMP. OPS CHECK GOODSDR JJBA20250822045Elec Connector · faultedFLAP FAIL, SPS ADVANCED EICAS MESSAGE DISPLAYED AFTER MOVING FLAP HANDLE DURING APPROACH. REMOVED AND REPLACED ELECTRICAL CONNECTOR PLUG P1104. FLAPS OPS CHECK GOOD. PERFORMED FLAP SCREWJACK ACTUATOR LUBRICATION ON ALL FLAP ACTUATORS. PERFORMED FLAP SCREWJACK SDR JJBA20250805132Inverter · inoperativeRIGHT EMERGENCY EXIT HATCH UPPER LIGHT PLACARD INOPERATIVE. REMOVED AND REPLACED INVERTER ASSEMBLY AT POSITION 5. OPS CHECK SAT.SDR JJBA20250716045Flap System · failedFLAP FAIL WHILE MOVING FROM 9 TO 22. FLAP SURFACES AND FSL ARE SET TO 9 DEGREES. ALSO, CONNECTORS P3683 AND P3682 ARE DISCONNECTED AND SECURED FOR FLAPS 9 FERRY FLIGHT. STARTED ZERO RIGGING OF LH IB FLAP. COMPLETED ZERO RIGGING. OPS CHECK SAT. CONNECTORS P3683SDR JJBA20250609008Panel · out of positionMCD WONT CLOSE, TOP PANEL HAS GAP AND EXTERNAL HANDLE NOT FLUSH. PERFORMED MCD ADJUSTMENT/TEST AND PERFORMED CHECK WITH THE FORCE GAUGE. LOAD IS WITHIN LIMITS, FOUND RH UPPER ROLLER CAM TO BE LOOSE. RESECURED CAM. SERVICED/LUBRICATED MCD. MCD CYCLE OPEN/CLOSE.SDR JJBA20250602004Lamp · inoperativeMCD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXTERNAL EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250602003Lamp · inoperativeCENTER AISLE CEILING EMERGENCY LIGHT AT ROW 18 INOPERATIVE. REMOVED AND REPLACED ROW 18 CENTER AISLE CEILING EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250512050Bolt · looseMAIN CABIN DOOR DIFFICULT TO CLOSE. FOUND INNER HANDLE BOX ATTACHMENT BOLTS TO BE LOOSE - TORQUED HANDLE BOX AND LUBRICATED DOOR. OPS CHECK SAT. NO FURTHER DEFECTS NOTED.SDR JJBA20250509045Handle · faultedMCD EXTERIOR DOOR HANDLE NOT FULLY FLUSH. FA REPORTED LOUDER THAN NORMAL WHISTLING SOUNDS. RE-SEALED LOOSED FRAME SEAL. PERFORMED PRESSURIZATION CHECK. OPS CHECK, LEAK CHECK SAT. NO NOISES PRESENT. DOOR HANDLE SEATS FLUSH.SDR JJBA20250221030Drive Unit · failedFLAP FAIL MESSAGE ON EICAS. NO FLAP CHANGE WHEN MOVING FLAP LEVER. REMOVED AND REPLACED FPDU. OPS CHECK GOOD.SDR JJBA20230605001Unknown · unknownMAIN CABIN DOOR UNLOCKING HANDLE LOWER ROLL PIN PULLED OUT RESECURED MAIN CABIN DOOR UNLOCKING HANDLE LOWER ROLL PIN.SDR JJBA20230303019None · nonePHOTO LUMINESCENT LIGHT STRIP LOOSE AT 3A. RESECURED EMERGENCY LIGHT STRIP AT 3ASDR JJBA20221227026Charger · inoperativeLH FWD WING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED #1 EMERGENCY LIGHT BATTERY CHARGER. OPS CHECK SAT.SDR JJBA20220912007Lamp · inoperativeMCD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EMERGENCY LIGHT ASSEMBLY. OPS CHECK SATSDR JJBA20220721023Light · inoperativeRH EXTERNAL LOWER EMERGENCY LIGHT RETAINER ASSY NOT FLUSH WITH FUSELAGE AND IS MISSING SEALANT. R&R EXTERNAL LOWER EMERGENCY LIGHT ASSEMBLY. OPS CHECK SAT.SDR JJBA20220613010None · inoperativeAC CABIN ALT RAPIDLY CLIMBED TO 8400 THEN 9000 FEET, CAB RATE CONTINUED TO -150. CAB ALT CONTINUED TO RISE. DID A RAPID DECENT AND EMERGENCY DECLARED. OPENED BOTH COCKPIT DV WINDOWS, INSPECTED SEALS, FOUND NO DEFECTS. THEN FULLY CLOSED BOTH WINDOWS. REMOVED ANSDR JJBA20220519036None · leakingBRAKE DEGRADED CAUTION MESSAGE ON FINAL APPROACH. ALL WHEEL SPEED SENSORS CHECKED AND FOUND SATISFACTORY. AIRCRAFT TAXIED OUT AND FOUND #2 BRAKES ON MFD HOTTER THAN ALL OTHER WHEELS. AIRCRAFT JACKED AND FOUND #2 BRAKES BINDING. REMOVED AND REPLACED #2 BRAKE ASSDR JJBA20220515027Lamp · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED COCKPIT EMERGENCY LIGHT LAMP. OPS CHECK SAT.SDR JJBA20220515026Battery Pack · inoperativeLH FWD WTF FAIRING EMERGENCY LIGHT INOPERATIVE. FOUND MULTIPLE EMERGENCY LIGHTS INOPERATIVE ON THE SAME CIRCUIT. REMOVED AND REPLACED #1 EMERGENCY LIGHT BATTERY. OPS CHECK SATSDR JJBA20211001004None · noneCOCKPIT ENTRY FLOOR BEAM HAS SIGNS OF CORROSION, TOOLING MARKS AND INCORRECT NUT PLATE INSTALLED. REMOVED AND REPLACED DAMAGE PROFILE REINFORCEMENT AT COCKPIT ENTRY FLOOR BEAM. CORROSION LEVEL 2SDR JJBA20211001003None · noneCOPILOT SIDE SEAT TRACKS (INBD/OUTBD) FLOOR BEAMS SHOW SIGNS OF CORROSION. REMOVED CORROSION AND EVALUATED AREA FOUND TO BE OUT OF LIMITS. FABRICATED REPAIR DOUBLER IND/OUT ISDE AT COPILOT SIDE SEAT TRACKS FLOOR BEAMS. INSTALL REPAIR DOUBLER. CORROSION LEVEL 2SDR JJBA20210930007None · nonePILOT SIDE INBD AND OUTBD SEAT TRACK FLOOR BEAMS SHOW SIGNS OF CORROSION (FS9-FS10 4WD LBL12 AND LBL24). BLENDED AREA FOUND TO BE OUT OF LIMITS IN RIGHT SIDE INBD AND OUTBD SIDE TRACK PLACE BEAM. FABRICATED 2 REPAIR DOUBLER IN INBD AND OTBD SIDE. APPLIED ALODISDR JJBA20210926002None · noneAFT FUSELAGE, UNDER TOILET AREA, RH GUSSET BEAMS, FROM FR 61 TO 59, BOTH HAT BEAMS HAS SIGNS OF CORROSION AT BOLT HOLES 4 EACH. BLENDED OUT CORROSION AND EVALUATED AT RH GUSSET FROM FR 59 - FR 60 FOUND TO BE OUT OF LIMITS. REMOVE DAMAGE GUSSET, LOCATE AND DRILSDR JJBA20210924010None · noneM/D CABIN RH SIDE, AT FRAME 53 - 34 FR SIGNS OF CORROSION ALONG FLOOR SILL. REMOVED AND REPLACED FLOOR SILL ON MID CABIN RH SIDE FR 56-41 AND FR 48-52. PERFORMED UTT BY NDT OF BLENDED AREA ON FR 41-48 MID RH CABIN FOUND TO BE WITHIN LIMITSSDR JJBA20210923006None · noneHAT BEAM RH AFT OF FR 59 FOUND TO HAVE CORRODED AREA AT NUT PLATE AREA. CUTOUT DAMAGE AREA. FABRICATED REPAIR DOUBLER. APPLIED ALODINE, PRIMER, TOP COAT AND INSTALLED REPAIR DOUBLER. CORROSION LEVEL 2SDR JJBA20210921033None · noneLH FUSELAGE AT FR60 SILL AREA, SMALL PLATE FOR WATER SUPPLY HAS A CRACK AT NUT PLATE. INSTALLED EWIS PROTECTION ON LH FUSELAGE AT FR60 TO FR 59. REMOVED CABLE AND DUCT FAIRING FOR ACCESS. REMOVED DAMAGED SMALL PLATE, LOCATED AND DRILLED NEW PLATE. RE-INSTALLEDSDR JJBA20210919027None · noneRH FR19, Y=479 SUSPECT CORROSION ON HAT-BEAM. REMOVED AND REPLACED HAT BEAM AT Y=479 RH FR19 CORROSION LEVEL 2SDR JJBA20210821003Rib · corrodedLH AILERON INBD RIB SHOWS SIGNS OF CORROSION. FABRICATED AND REPLACED LH AILERON INBD RIB.SDR JJBA20210818048Panel · corrodedVERTICAL STAB INSIDE PANEL 325CL THE UPPER RUDDER ACTUATOR CONNECTING HARDWARE IS CORRODED. REMOVED & REPLACED UPPER RUDDER ACTUATOR BOLT & HARDWARESDR JJBA20210719021Target · out of adjustLG AIR/GROUND FAIL CAUTION MESSAGE RIGHT AFTER ROTATION FOLLOWED BY ENG 1-2 REV DISAGREE. ADJUSTED NLG DOWNLOCK PROX SWITCH TARGET. OPS CHECK SAT. PERFORMED OPERATIONAL CHECK OF #1 AND #2 T/R. OPS CHECK SAT. NO FAULTS FOUND AT THIS TIME. OPS CHECK SAT ON GEAR SDR JJBA20210523025None · noneFUEL LEAK COMING FROM PANEL 651CB. REMOVED PANEL 651 CB. FOUND FUEL IN THE DRY BAY OUTSIDE OF RIB 20. AILERON PCA`S HAD FUEL ON THEM, THE HYDRAULIC LINE CLOTH COVERS WERE SOAKED IN FUEL WITH FUEL ON THE PANEL AND IN THE DRY BAY AREA. UNABLE TO CLASSIFY THE LEASDR JJBA20210402007Seat Frame · crackedCRACKED AISLE SIDE FRAMES ON SEATS 4A, 10A, 19A, AND 22A. R&R SEATS 4A, 10A, 19A, AND 22A.SDR JJBA20201213026Battery Pack · no testDURING OPERATIONS CHECKS OF EMERGENCY LIGHT FOUND SERVICE DOOR. EXIT IDENTIFIER, EXIT MARKER, EXIT LOCATOR ALL LOCATED IN GALLEY AREA INOPERATIVE. REMOVED AND INSTALLED NEW NR 2 BATTERY PACK AND CHARGER. EMERGENCY LIGHT OPERATION TEST GOOD.SDR JJBA20201209023Seat Track · corrodedLEFT AISLE UNDER SEAT TRACK NR 29 FLOOR BEAM HAS CORROSION. REMOVED AND REPLACED LEFT AISLE UNDER SEAT TRACK NR 29 FLOOR BEAM.SDR JJBA20201207017Stringer · damagedSTRINGER HAS GROOVE CUT IN THE BOTTOM SIDE, AT FR 17X+10.562 AND STGR 15R. REMOVED DAMAGED SECTION OF STRINGER 15R BETWEEN FRAMES 15 AND 16 ENDING AT FRAME 20 AND SPLICED IN NEW SECTION OF STRINGER.SDR JJBA20201204025Seat Track · corrodedLEFT AISLE, UNDER SEAT TRACK NR 31 FLOOR BEAM HAS CORROSION. REMOVED AND REPLACED LEFT AISLE UNDER SEAT TRACK NR 31 FLOOR BEAM.SDR JJBA20201204024Seat Track · corrodedLEFT AISLE, UNDER SEAT TRACK NR 30 FLOOR BEAM HAS CORROSION. REMOVED AND REPLACED LEFT AISLE UNDER SEAT TRACK NR 30 FLOOR BEAM.SDR JJBA20201204022Buttstrap · corrodedLT FLOOR STRUCTURE UNDER SEAT 1A CORROSION ON BUTT STRAP IN 2 LOCATIONS. REMOVED AND REPLACED BUTT STRAP FLOOR STRUCTURE UNDER SEAT 1A.SDR JJBA20201125021Frame · corrodedRIGHT ENGINE, FORWARD FRAME AFT FLANGE TO COMPOSITE OUTER BYPASS DUCT HAS MULTIPLE LOCATIONS OF CORROSION AROUND CIRCUMFERENCE APPROXIMATELY 60 PERCENT OF THE CIRCUMFERENCE. UPON FURTHER EVALUATION THE LOCATIONS OF CORROSION FOUND ON RIGHT ENGINE, FORWARD FRASDR RAIA2019121080001Flap System · unknownFLAP FAIL ON APPROACH AT 0 DEGREE---PERFORMED GVI OF FLAP SYSTEM AND RAN OPS CHECKS OF FLAPS,OPS CHECK GOOD ACFT OK FOR SERVICESDR RAIA201909230002Control Unit · inoperativePITCH TRIM MAIN INOP FOLLOWED BY PITCH TRIM BACKUP INOP. RETURNED FROM FLIGHT AND DECLARED EMERGENCY. LANDED WITHOUT INCIDENT. R&R HSCU AND MAIN PITCH TRIM CUTOUT SWITCH. OPS CHECK GOOD.SDR RAIA2019083029001Frame · corrodedLOWER FRAME ON CARGO DOOR HAS CORROSION AROUND NUTPLATE HOLES. R&R LOWER FR ON CARGO DOOR.SDR RAIA2019083027003Gusset · corrodedLH OMEGA BEAM UPPER DIGITAL SUPPORT HAS CORROSION AT FRAME 59. REMOVED & REPLACED LH OMEGA BEAM GUSSET, NUT PLATES STILL NEED TO BE INSTALLED. INSTALLED NUT PLATES.SDR RAIA2019082970002Frame · crackedCOCKPIT FRAME 10 RH SIDE IS CRACKED AT UPPER END- R & R FR 10 RH.SDR RAIA2019082970001Frame · crackedCOCKPIT FRAME 10 LH SIDE IS CRACKED AT UPPER END. R & R FRAME 10 LH.SDR RAIA201908260001Web · crackedLT WW REAR WEB IS CRACKED AT LOWER O/B CORNER. R&R LT WW REAR WEB.SDR RAIA201908200008Shear Tie · crackedRT SHEAR CLIP AT FR 80 BETWEEN STR 5&6 IS CRACKED. REMOVED CRACKED SHEAR CLIP AT FRAME 80 BETWEEN STRINGERS 5&6 AND INSTALLED NEW SHEAR CLIP.SDR RAIA201908200007Shear Tie · crackedLT SHEAR CLIP AT FR 80 BETWEEN STR 5&6 IS CRACKED. REMOVED LT SHEAR CLIP AT FRAME 80 RT BETWEEN STRINGERS 5 & 6 AND INSTALLED HI-LOKS INTO NEW PART, AIRCRAFT RIVETS NEED TO BE INSTALLED. FINISHED SHEAR CLIP INSTALLATION BY INSTALLING ALL RIVETS AND ANY OTHER RSDR RAIA2019083020006Floor Support · corrodedLH FLOOR SILL HAS LIGHT CORROSION ON UPPER SURFACE BETWEEN FRAME 54 & 55 LH. REMOVED AND STARTED INSTALLING LH FLOOR SILL AT FR 54-55. FINISHED INSTALLING LH FLOOR SILL AT FR 54-55.SDR RAIA2019083020005Gusset · corrodedAFT LAV CENTER OMEGA BEAM UPPER DIGITAL SUPPORT HAVE CORROSION AROUND NUTPLATE HOLE AT FRAME 59. REMOVED & REPLACED AFT LAV CENTER OMEGA BEAM GUSSET, NUTPLATES STILL REQUIRED TO BE INSTALLED. INSTALLED NUTPLATES.