N17146
Service difficulty reports · 100
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N17146' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N17146' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20260508004Terminal Block · meltedWOOD BURNING SMELL IN COCKPIT, NEAR GLARE SHIELD FO SIDE. FOUND RH W/S SENSORS TO SHOW EVIDENCE OF ELECTRICAL DAMAGE SUCH AS MELTING SENSORS, TERMINAL BLOCK MELTING, AND SOLDER DAMAGE TO TERMINALS P AND G. REMOVED FO'S WINDSHIELD AND ALSO WIPER AND REPLACED 4SDR JJBA20260415013Unknown · odorBURNING ODOR DURING ANTI-ICE OPS IN FLT FOLLOWED BY BLEED 1 LEAK. ODOR DIMINISHED LEAVING ICING CONDITIONS. CRISPY SWEET BURNING ODOR. THE ODOR ONLY OCCURRED IN THE FLT DECK, THE FLT ATTENDANT COULD BRIEFLY SMELL IT BUT IN THE FLIGHT CREW EYES WERE WATERING. TSDR JJBA20260216026Shear Tie · crackedFRAME 61 RH SHEAR TIE CRACKED. REMOVED AND REPLACED SHEAR TIE.SDR JJBA20260216031Shear Tie · corrodedFRAME 51 LH SHEAR CLIP CORRODED BEYOND LIMITS. REMOVED AND REPLACED SHEAR CLIPSDR JJBA20260216030Floor Support · corrodedLAV RT FLOOR SILL CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLOOR SILL.SDR JJBA20260216029Channel · corrodedSERVICE DOOR SILL CAP CORRODED BEYOND LIMITS. REMOVED AND REPLACED SERVICE DOOR SILL CAP.SDR JJBA20260216028Floor Support · corrodedR3 FLOOR SILL CORRODED BEYOND LIMITS. REMOVED AND REPLACED RH #3 SILL.SDR JJBA20260216027Doubler · corrodedFWD PARTITLLON DOUBLER AT FRAME 61 CORRODED. REMOVED AND REPLACED DOUBLER 1SDR JJBA20241219033Control Lever · inoperativeFLAP FAIL IN FLIGHT. FOLLOWED FIM. FOUND NO DEFECTS. COULD NOT DUPLICATE FLAP FAIL FAULT. CHECKED ELECTRICAL CONNECTORS P1100 AND P110415 IS PROPERLY PLUGGED. OPS CHECK SAT. REMOVED AND REPLACED FLAP SELECTOR LEVER. OPS CHECK SATSDR JJBA20240805003Light · misinstalledRH OVERWING EMERGENCY EXIT LIGHT INSTALLED UPSIDE DOWN. REMOVED AND REINSTALLED OVERWING EMERGENCY EXIT LIGHT CORRECTLY.SDR JJBA20240805002Sign · inoperativeFWD EXIT EMERGENCY SIGN ABOVE ROW 18 INOPERATIVE. REMOVED AND REPLACED FWD EXIT EMERGENCY SIGN ABOVE ROW 18. OPS CHECK SAT.SDR JJBA20240708003Door · lack of lubeMAIN CABIN DOOR IS HARD TO CLOSE WITH HANDLE. LUBRICATED DOOR. OPS CHECK SAT.SDR JJBA20240502068Connector · disconnectedFOUND MULTIPLE EMERGENCY LIGHTS INOPERATIVE. FOUND CONNECTOR DISCONNECTED, RE-CONNECTED CONNECTOR. OPS CHECK SATSDR JJBA20240429064Lamp · inoperativeCOCKPIT EMERGENCY LIGHT OUT. REMOVED AND REPLACED BULB. OPS CHECK SAT.SDR JJBA20240422055Door · faultedMCD WONT OPEN FROM OUTSIDE OF AIRCRAFT. PERFORMED OPS CHECK ON MCD. OPS CHECK SATSDR JJBA20230911004Unknown · unknownRT EMERGENCY EXIT DOOR SHOWING OPEN. CLEANED MICRO SWITCH. OPS CHECK SAT.SDR JJBA20230818004Sign · looseCENTRAL CABIN OVERHEAD FWD EMERGENCY LIGHT INOP. FOUND CONNECTOR LOOSE, RECONNECTED. OPS CHECK SATSDR JJBA20230303001None · noneMAIN CABIN DOOR WON'T COMPLETELY CLOSE. CLEANED DOOR SEAL AND LUBED THE ROLLER. OPS CHECK GOOD.SDR JJBA20221017006Skin · gougedGOUGE ON BAGGAGE DOOR FORWARD OF VENT HANDLE AS MARKED. REMOVED DAMAGE AND INSTALLED REPAIR DOUBLER AND FILLER ON BAGGAGE DOOR FWD LOWER EDGE SKIN.SDR JJBA20221017008Skin · corrodedCORROSION FOUND ON INTERNAL FUSELAGE SKIN AROUND CUTOUT FOR RAT #2 ANTENNA CABLE. REPAIRED REAR FUSELAGE SKIN AT RAT #2 ANTENNA.SDR JJBA20221017007Skin · corrodedREAR FUSELAGE I SKIN HAS CORROSION UNDER RAR #2 ANTENNA BASE. REPAIRED SKIN UNDER RAR #2 ANTENNA WITH REPAIR DOUBLER FILLERSDR JJBA20221017010Skin · dentedEXTERNAL FUSELAGE - DENT LOCATED BETWEEN FR 26 AND FR 27 BETWEEN STGR 20 AND 21 LH. REPAIRED DENT FR26-27 STRINGERS 20L-21L WITH CUTOUT AND DOUBLER/FILLERSDR JJBA20221017009Yoke · damagedDAMAGED HOLE #1 PYLON YOKE UPPER FLANGE, AFT FASTENER. REPAIRED HOLE ON #1 PYLON YOKE UPPER FLANGE AT AFT FASTENER LOCATION.SDR JJBA20220728033Light · inoperativeEMERGENCY FLOOR STRIP LIGHTING POTENTIALLY IN INCORRECT POSITIONS. REINSTALLED EMERGENCY FLOOR STRIP TO CORRECT LOCATIONSSDR JJBA20220719013Gear · unlatchedLG AIR /GND FAIL IN FLIGHT. R&R LEFT MLG FORWARD PROX SWITCH & RIGHT MLG AFT PROX SWITCH. PERFORMED GEAR SWINGS WITH BREAK OUT BOXSDR JJBA20220520039None · noneFRONT SIDE OF EMERGENCY EXIT LIGHT IS INOPERATIVE. RESECURED EMERGENCY EXIT LIGHT CONNECTIONSDR JJBA20210618026Unknown · odorDIRTY SOCK SMELL ON CLIMB OUT AND APPROACH. PERFORMED BOROSCOPE INSPECTION OF COMPRESSOR FLOWPATH EXTENSION FOR FRONT SUMP OIL LEAKAGE. NO DEFECTS NOTED. #1 PERFORMED BACK LIGHT INSPECTION OF ENGINE #1 FOR OIL LEAKAGE. .0 CARBON SEAL, NO FAULT NOTED. PERFORMESDR JJBA20201125016Proximity Switch · out of adjustLANDING GEAR AIR/GROUND FAIL MESSAGE ON EICAS. WITH POWER OFF PINS D&V OF P7164 TO GROUND AT .4 OHM & WITH POWER ON AT 1.7 OHMS AND SLOWLY RISING. REBONDED & SEALED GS0366DC. NOW READING .5 OHM WITH POWER ON. JACKED A/C FOUND RT GEAR SHOCK ABSORBER AIR/GRNSDR JJBA20201112008Proximity Switch · out of adjustLG AIR/GROUND FAIL ON EICAS AND LANDING GEAR WOULD NOT RETRACT. FOUND LEFT SHOCK MLG WOW PROX SWITCH GAP OUT OF LIMITS ADJUSTED GAP. FOUNT RT MLG SHOCK WOW PROX SWITCH DEFECTIVE REMOVED AND REPLACED RIGHT MLG SHOCK WOW PROX SWITCH. OPERATIONS CHECK GOOD.SDR RAIA2019122070001Pump · failedHYDRAULIC SYSTEM 2 FAIL. R&R #2 HYDRAULIC PUMP. OPS CHECK GOOD.SDR RAIA2019111310004Door Frame · corrodedZ FRAME AT CARGO DOOR FR 65 HAS CORROSION.... PERFORMED TEMP REPAIR ON Z ANGLE REP ETD2019-145-150902SDR RAIA2019111310003Angle · crackedCARGO RAMP FWD L ANGLE IS CRACKED.... REMOVED AND REPLACED CARGO RAMP FWD L ANGLESDR RAIA2019111310002Door · corrodedFWD CARGO DOOR AT FRM 65 AND STG 15 RIB HAS CORROSION.... REMOVED AND REPLACED RIB AT FRM 65 AND STG 15..SDR RAIA2019111630044Support · crackedCARGO DOOR HOLD OPEN ROD CUP SUPPORT IS CRACKED- REMOVED CARGO DOOR HOLD OPEN ROD CUP. INSTALLED CARGO DOOR HOLD OPEN CUP SUPPORT.SDR RAIA201911153043Floor Support · corrodedRH FLOOR SILL HAS CORROSION BETWEEN FR30 & FR 35- REMOVED RH FLOOR SILL BEWTEEN FR30 TO FR35. INSTALLED NEW RH FLOOR SILL FR 30 - FR35.SDR RAIA2019111530042Floor Support · corrodedLH FLOOR SILL HAS CORROSION BETWEEN FR48 TO FR52- REMOVED LH FLOOR SILL BETWEEN FR48-FR52. INSTALLED LH FLOOR SILL.SDR RAIA2019111300039Floor Support · corrodedL/H FLOOR SILL HAS CORROSION BETWEEN FR 48 FR52.... REMOVED AND REPLACED L/H FLOOR SILL BETWEEN FR 48- FR 52SDR RAIA2019111300037Angle · corrodedCARGO DOOR CUTOUT Z-ANGLE HAS CORROSION....REMOVED AND REPLACED CARGO DOOR CUTOUT Z-ANGLESDR RAIA2019111300036Floor Support · corrodedL/H FLOOR SILL AFT OF CARGO DOOR HAS SIGNS OF CORROSION..... REMOVED AND REPLACES L/H FLOOR SILL AFT OF CARGO DOOR.SDR RAIA2019111130032Floor Support · corrodedL/H FLOOR SILL HAS CORROSION AT FR 36-FR41... REMOVED AND REPLACED FLOOR SILL...SDR RAIA2019111130031Floor Support · corrodedL/H FLOOR SILL HAS CORROSION AT FR 24-FR29... REMOVED AND REPLACED FLOOR SILL...SDR RAIA2019111130030Floor Support · corrodedL/H FLOOR SILL HAS CORROSION AT FR 30-FR35... REMOVED AND REPLACED FLOOR SILL...SDR RAIA201911113029Floor Support · corrodedR/H FLOOR SILL HAS CORROSION AT FR 48-FR52... REMOVED AND REPLACED FLOOR SILL...SDR RAIA2019111130028Floor Support · corrodedR/H FLOOR SILL HAS CORROSION AT FR 42-FR47... REMOVED AND REPLACED FLOOR SILL...SDR RAIA201911113027Floor Support · corrodedL/H FLOOR SILL HAS CORROSION AT FR 18-FR23... REMOVED AND REPLACED FLOOR SILL...SDR RAIA2019110930026Shear Tie · corrodedSHEAR CLIP HAS CORROSION AT FR 53 STG20-21R.... REMOVED AND REPLACED SHEAR CLIP AT FR 53 ATE STG 20-21RSDR RAIA201911090025Floor Support · corrodedR/H OMEGA BEAM HAS CORROSION AT FR23.... REMOVED DAMAGED AREA AND INSTALLED DOUBLER ON R/H OMEG BEAM AT FR 23SDR RAIA201911090024Floor Support · corrodedR/H FLOOR SILL HAS CORROSION BETWEEN FR36-FR41... REMOVED AND REPLACED R/H FLOOR SILL BETWEEN FR36-FR41SDR RAIA201911129005Spar · crackedL/H HORIZONTAL STAB O/B SPAR IS CRACKED..... REMOVED AND L/ HORIZONTAL STAB O/B SPAR, REMOVED DAMAGE AND INSTALLED DOUBLER IAW ETD2019-145-150917SDR RAIA2019100193001Line · cutTOTAL LOSS OF HYD FLUID IN SYS NR 1. FOUND LASCERATION ON E1 HYD PUMP PRESSURE LINE. R & R THE LINE SERVICED THE HYD SYS NR 1, RAN ENGINES AT POWER, OPS AND LEAK CHECK GOOD.