N213UA
Service difficulty reports · 185
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N213UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N213UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009111603571Sdu · malfunctionedSATCOM HI GAIN SATCOM HI GAIN IS FAILED. STATUS CREW COMMENTS: CHRONIC GRIPE. MSG-2360131 ACTIVE ER INTER MSG-2360121 ACTIVE ER INTER. REPLACED SDU, SYSTEM PASSED TEST.SDR UALA2009111003511Connector · not seatedVHF CENTER HEAD OFF. RESEATED CONNECTOR ON CENTER VHF AND NOW NORMAL.SDR UALA2009110403422Antenna · faultySATCOM HI GAIN IS FAILED. AWAITING ANTENNAS AND GASKETS. HARD FAULT MESSAGE TOP-PORT HGA FAIL. REPLACED SPLITTER, NO HELP. REPLACED LEFT SMHGA ANTENNA, SATCOM SYSTEM TEST OKAY.SDR UALA2009100603137Amplifier · malfunctionedSATCOM HI GAIN FAILED. STATUS MSG01- ACTIVE CRUISE HARD; HGA HIGH POWER AMPLIFIER (LEFT) OR SATELLITE DATA UNIT (LEFT) OUTPUT CIRCUIT IS OPEN OR SHORTED. DB- SATELLITE DATA UNIT (LEFT) MSG-2360121 ACTIVE ER HARD. RESET HI GAIN CB AND SDU L CB, NO HELP. SSDR UALA2009093003080Transceiver · malfunctionedLEFT HF INOP WILL NOT SEND OR RECEIVE. REPLACED LEFT HF COMM TRANSCEIVER. MAT CHECKED GOOD. REPLACED LEFT HF COMM TRANSCEIVER. MAT CHECKED GOOD.SDR UALA2009090302770Nose Cowl · damagedNR 1 ENG STRUCK JETWAY WHILE PARKING AT GATE B17. NOSE COWL OUTER SKIN AND CORE DAMAGED. NO DAMAGE TO INNER SKIN. ACCMP'D INTERIM REPAIR TO L-NOSE COWL. INSTALLED METAL PATCH INNER AND OUTER FAN COWL SEAL EDGES AND TAPE. ACFT FERRIED TO SFO FOR REPAIR. NSDR UALA2009081302491Probe · faultyFUEL QUANTITY INDICATION ON EICAS DISPLAY - FLUCTUATES. CREW COMMENTS: FUEL QTY FLUCTUATES 2000 POUNDS. PERFORMANCE PAGE SHOWS CALC FUEL. RIGHT FUEL QTY SENSOR 19 SHOWS 0.0 SENSOR 18 SHOWS 8.6 SENSOR 20 SHOWS 0.7 RIGHT FUEL QTY INOP TOTAL FUEL QTY ALSO INOSDR UALA2009072702235Microphone · faultyFIRST OFFICER OXYGEN MIC INOPERATIVE. NEED NEW O2 ASSY PN MXP 402-3. NR INOP 02 ASSY WAS MOVED TO SECOND OBSERVERS SEAT, AND MEL USED REFLECTS THIS. 2ND OBSERVERS SEAT IS INOP (FIRST OFFICERS O2 ASSY IS OK)SDR UALA2009072002140Processing Unit · faultyPER FLT CREW CENTER FUEL TANK QTY INOP. REPLACED FUEL QUANTITY PROCESSOR UNIT, CHECKS OKAY.SDR UALA2009062901835Line · leakingLOSS OF HYD C-SYSTEM QUANTITY AND PRESSURE. REPLACED NLG STEERING LINE. LEAK CHECKED GOOD.SDR UALA2009031300784Seal · leakingFUEL LEAK FROM NR 1 ENG STRUT AREA. FOUND MAIN FUEL FEED LINE IN PYLON LEAKING. ACP'D MM 28-22-15 AND REPLACED COUPLING SEALS. WET MOTOR AND RAN NR 1 ENG. NO LEAKS FOUND.SDR UALA2009031200770Module · failedLEFT PACK FCV VLV INOP AT FL370, PRESSED AIR CON RESET TWICE DURING COURSE OF FLT, BUT CONTINUED TO FAIL. CHRONIC HISTORY. REPLACED FLOW SENSOR, NO HELP. REPLACED LEFT FLOW SENSOR MODULE, SYS TEST OK.SDR UALA2008111306361Controller · faultyAPU BLEED AIR APUC DETECTED LOSS OF ABILITY TO PNEUMATICALLY LOAD APU. MESSAGE IS TRIGGERED BY IGV OR SURGE CONTROL SYSTEM FAULTS. STATUS MSG01- NOT ACTIVE ENGINE START MODE DEPENDENT; SURGE CONTROL VALVE (PNEUMATIC CLUSTER) DOES NOT FOLLOW COMMAND. DB- ASDR 2008UALA06361Controller · faultyAPU BLEED AIR APUC DETECTED LOSS OF ABILITY TO PNEUMATICALLY LOAD APU. MESSAGE IS TRIGGERED BY IGV OR SURGE CONTROL SYSTEM FAULTS. STATUS MSG01- NOT ACTIVE ENGINE START MODE DEPENDENT; SURGE CONTROL VALVE (PNEUMATIC CLUSTER) DOES NOT FOLLOW COMMAND. DB- APUSDR 2008UALA05678Generator · leakingRIGHT BACK UP GENERATOR OFF OR FAILED. RIGHT BUG WILL NOT HOLD OIL LEAKING ON ENG RUN. NR 2 ENGINE BUG FOUND UNDERSERVICED. SERVICED UNIT RAN ENGINE, WITHIN 2 MINUTES OIL COULD BE SEEN EVACUATING FROM OVERFILL DRAIN. REMOVED BUG. INSTALLED REPLACEMENT BACSDR 2008UALA05666Idg · faultyRIGHT IDG HAS BLOCKED MESSAGE ON EICAS CHAPTER 24 MAINTENANCE PAGE. IDG FOUND FAULTY. REPLACED IDG. OP CHECK & LEAK CHECK GOOD. RESERVICED RT IDG. OK FOR SERVICE.SDR 2008UALA03955Starter · faultyLEFT ENGINE WILL NOT START. *S/D* SUSPECT FAULTY STARTER. REPLACED STARTER IAW MM 80-11-01, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03778Start Valve · faultyENG START VALVE L LEFT STARTER AIR VALVE POSITION DISAGREES WITH COMMANDED POSITION OR STARTER AIR VALVE POSITION INDICATION IS LOST. STATUS MSG01- NOT ACTIVE ENGINE START MODE DEPENDENT; STARTER AIR VALVE (SAV) (L ENG) IS NOT IN COMMANDED POSITION. DB- ELESDR 2008UALA02910Slide · misinstalledENTRY DOOR 2L ESCAPE SLIDE SAFETY PIN HOLE IS OBSTRUCTED. SUSPECT IMPROPERLY INSTALLED. REPLACED SLIDE PER MM 25-6 6-01-401. AC OK FOR SERVICE.SDR UALA2008111302896Skin · damagedLIGHTNING STRIKES LT HORIZ STAB UPPER SURFACE, INBOARD END. FOUND LIGHTNING STRIKES. ACCOMPLISHED PERMANENT REPAIR PER SRM 51-20-06. AC OK FOR SERVICE.SDR 2008UALA02896Skin · damagedLIGHTNING STRIKES LT HORIZ STAB UPPER SURFACE, INBOARD END.SDR 2008UALA01567Connector · damagedTHE L FWD FUEL BOOST PUMP PRESSURE SWITCH SIGNAL IS LOW WITH L FWD FUEL BOOST PUMP ON. FOUND FAULTY FUEL PUMP AND CONNECTOR DAMAGED. REPLACED CONNECTOR AND PUMP. AC OK FOR SERVICE.SDR 2008UALA00710Oil System · leakingRTFL DUE TO NR 1 OIL QUANTITY LOSS INDICATION. THE ENGINE'S ANGLE GEARBOX (AGB) WAS REPLACED AT HNL, AND THE AIRCRAFT RETURNED TO SERVICE. PROBLEM DID NOT RECUR. SHOP INVESTIGATION FOUND THAT THE AGB SNOUT PACKING (IPC 72-62-00-001-001) WAS WORN FLUSH WITH TSDR 2007UALA05199Gcu · burnedRTFL DUE TO A RT ENGINE GENERATOR PROBLEM. AFTER TROUBLESHOOTING,FOUND RT GCU CIRCUIT BREAKER OPEN & GEN CONTROL UNIT BURNED INSIDE. REPLACED GCU AND OPS CHECKED GOOD. OPENED UP GCU MR24241-13 AND VERIFIED A UNIT INTERNAL FAILURE WITH BURNED CIRCUIT BOARD. SDR 2007UALA02359Slat · damagedRIGHT WING MOST OUTBOARD L/E SLAT 14 IS DAMAGED. [07-27-07] REMOVED NR 14 SLAT AND INSTALLED SERVICABLE SURFACE PER 27-81-15. ACCOMPLISHED TEST FLIGHT. AIRCRAFT TESTS OK & IS READY FOR SERVICE. SUSPECT SLAT IMPACTED BY GROUND EQUIPMENT.SDR 2007UALA00689Outflow Valve · stuckFLIGHT DIVERTED DUE TO NO WATER PRESSURE. PRE-SELECT OVERFLOW VALVE FOUND TO STICK IN SEMI-CLOSED POSITION. PRIOR TO REPLACEMENT- CHECKED LINKAGES, INDICATION & VALVE OPERATION. VLV OPERATION NORMAL WITH PRE-SELECT KNOB MOVEMENT AT FWD SERVICE PANEL. PRECASDR 2007UALA00585A/C Pack · inoperativeLOST RIGHT PACK AFTER DEPARTURE. REPLACED RIGHT SYSTEM LOWER SHUTOFF-PACK FLOW CONTROL VALVE PER MM 21-51-02, PASSED TEST & CLEARED MESSAGE 21-24304 . SUSPECT VALVE STUCK DUE TO FRICTIONAL-INDUCED WARE.SDR 2007UALA00390Water System · low pressureFLT DIVERTED DUE TO NO WATER PRESSURE IN ENTIRE ACFT. PERFORMED OPS CHECK OF WATER SYS ALSO OPS CHECK PRESELECT WATER VALVE ABOVE CEILING PANEL IN FIRST CLASS, ALSO CHK DRAIN VALVE, PRESURE CHECK WITH AND WITHOUT APU BLEED, ALSO REFILLED WATER TO FULL. UNABLSDR 2006UALA02209Skin · damagedLIGHTNING STRIKES LT HORIZONTAL STABILIZER UPPER SURFACE, INBOARD END. INSTALLED COMPOSITE REPAIR PER REO-G10674A. REPAIR IS CONSIDERED TEMPORARY. MUST BE REINSP. EVERY 500 CYC, WITH M AX LIMIT 3000 CYC. MF4982 CREATED TO MONITOR. SANDED & REMOVED PSDR 2005UALA00640Odor · detectedELECTRICAL ODOR IN CABIN. THE FWD LAV FLUORESCENT LIGHT WAS ARCING CAUSING ELECTRICAL ODOR. THE CB WAS PULLED AND THE LAV INOP'D FOR REMAINDER OF FLIGHT UNTIL MECHANIC COULD EXAMINE LIGHT ON GROUND. MECHANIC RESET CIRCUIT BREAKER AND DETERMINED LIGHT TO BE OKSDR 2005UALA00568Strap · misroutedTHE MIDDLE STRAP UNDER THE SLIDE WAS WRAPPED AROUND THE OUTER TUBES WHICH WOULD HAVE CAUSED THE SLIDE TO NOT DEPLOY AND FUNCTION LIKE IT SHOULD. DURING SLIDE/RAFT DISASSEMBLY, CENTER TENSION WEB WAS FOUND MISROUTED AROUND INFLATION TUBES. IT IS SUSPECTED MISSDR 2005UALA00564Skin · lightning strikeLIGHTNING STRIKES LT HORIZONTAL STAB UPPER SURFACE, INBOARD END. LIGHTNING STRIKES LT HORIZ STAB UPPER SURFACE, INBD END. A MAJOR REPAIR WAS INSTALLED PER REO-G1067A & EVA-50377. THIS COMPOSITE REPAIR IS INTERIM (FOR 24 MONTHS - 10JUN07) OR NEXT SCHEDULED 'SDR 2003UALA00686Light · malfunctionedEMERGENCY EXIT LIGHTS ON AND OFF DURING TAXI. CHECKED AND CYCLED COCKPIT, DOOR 1, DOOR 4 SWITCHES.SDR 2002UALA01886Idg · failedVIA SATFONE, CAPT ADVISED HE LOST THE RT GENERATOR. RT GENERATOR WENT OFF LINE WITH NO EICAS MESSAGE OR COCKPIT INDICATION EXCEPT RT GEN "OFF" LIGHT. ATTEMPT TO RESET WAS UNSUCCESSFUL. SUPPLEMENTAL DATA UPDATE THERE WAS AN ASSOCIATED MESSAGE 24-12092 POWER BSDR 2002UALA00306Odor · detectedPER CREW, OIL SMELL IN CABIN DURING DESCENT.
Back to N213UA