N213UA
Service difficulty reports · 185
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N213UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N213UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011121406841Flight Recorder · malfunctionedFLT RECORDER SYS FLIGHT DATA RECORDER SYSTEM OFF OR INOPERATIVE WITH ANY ENGINE IN START MODE OR ANY ENGINE IN RUN MODE OR AIRCRAFT AIRBORNE. VOICE RECORDER OK. REPLACED FLIGHT RECORDER PER AMM, TESTED OKAY.SDR UALA2011120506679Audio Panel · faultedCAPTAIN'S AUDIO PANEL NO RECEPTION. SWAPPED CAPTAIN'S AUDIO PANEL WITH 1ST OBS, NO HELP. REPLACED AMU AS PER MM, NO HELP. RESET POWER TEST OK REF MM.SDR UALA2011120506678Control Panel · malfunctioned1ST OBS AUDIO CTL PNL IST OBS HAS NO OUTPUT. FAILED ON TEST. REPLACED 1ST OBS AUDIO CTL PNL AS PER MM. CHECKED OKAY.SDR UALA2011120506673Audio Control · faultyON TAXI OUT VHF 1 RADIO BECAME SCRATCHY AND UNREADABLE. REPLACED AUDIO MANAGEMENT UNIT PER AMM. ALL FUNCTIONS CHECK NORMAL. RADIO CHECK NORMAL.SDR UALA2011102705822Fseu · faultedAFTER ACCOMPLISHING AILERON HIGH SPEED COA 209904. CENTER PRIMARY FLIGHT COMPUTER LANE 3 HAS A FAULT. REPLACED FSEU-2. ALL GROUND TESTS PASSED.SDR UALA2011101805643Generator · faultyRT ENG BACKUP GENERATOR HAS OIL BLOCKED INDICATION ON EICAS DISPLAY. REPLACED BACKUP GENERATOR PER MM, RAN ENG PER TASK 71-00-00, CHECK'S OKAY.SDR UALA2011101105519Unknown · malfunctionedHYDIM CARD HR LOSS OF RIGHT HYDIM CARD (HR). (STATUS) -DEFERRED PER 2911H. -INF- :MESSAGE SHOULD READ HYDIM CARD HCR. ACCOMPLISHED LRU REPLACEMENT TEST VIA MAT, HCR CKS GOOD, NO ACTIVE OR LATCHED FAULTS. SOFTWARE CONFIG CHECK ALSO CHECKS GOOD.SDR UALA2011092605197Actuator · failedTURBINE CASE COOLING ACTUATOR STUCK OR REVERTED TO ITS FAIL-SAFE POSITION. TURBINE CASE COOLING LPT VALVE DEACTIVATED REF MEL 7524B; ROD END IS IN LOB. PERFORMED WIRING CHECKS PER FIM'S 75-24 TASK 805 & 806, ALL TESTED GOOD, REPLACED EEC PER MM, STILL FAULTSDR UALA2011092605196Thermocouple · fodNR 2 ENG TCA THERMOCOUPLE PROBE AT 9 O'CLOCK POS DOES NOT SEAT COMPLETELY. SUSPECT DEBRIS IN HOLE. INSTALLED TCA PROBE AFTER REMOVAL OF FOD. 5 MIN CHECK ENGINE TEMPS, NORMAL.SDR UALA2011071903656Panel · crackedTHE 195CL PANEL HAS A CRACKED - DELAM EDGE AFT END NEAR RT LATCH. 1 INCH LONG. .5 INCH WIDE. EDGE BAND DAMAGE REMOVED AND TAPED WITH SPEED TAPE TO PREVENT MOISTURE INGRESS. TAPE TO BE RECHECKED EACH 3 SVC FOR SECURITY. ** MF7793 CREATED TO MONITOR ** -ISDR UALA2011062903198Computer · faultyFLIGHT CONTROLS SYSTEM BELOW MINIMUM DISPATCH REQUIREMENTS. REPLACED AND OPS CHECKED CENTER ACE AND CENTER PFC PER MM. ALL TESTS PASSED.SDR UALA2011050202140Computer · faultyLEFT PRIMARY FLIGHT COMPUTER HAS LANE 3 LATCHED FAULT AND WILL NOT RESET. REPLACED PFC, INSTALLED SOFTWARE & PERFORMED INSTALLATION TESTS.SDR UALA2011042902092Apu · faultyAPU AND APU DOOR EICAS MESSAGE, NO START. REPLACED APU AND OPS CHECK NORMAL PER MM.SDR UALA2011041101722Window · leakingWINDOW 2L SQUEAL DID NOT SOUND AT ALL DURING CLIMB, HOWEVER THE SQUEAL. REPLACED 2L WINDOW MM.SDR UALA2011041101723Fan · faultyPRIOR TO DEPARTURE, RT LAVATORY/GALLEY VENT FAN MESSAGE DISPLAYED. FOUND C/B POPPED, RESET, FAILED TEST. REPLACED RT VENT FAN PER MM, MAT OPS CHECK PASSED - NO MORE STATUS MESSAGE.SDR UALA2011041101740Link · out of adjustNOISE FROM LOWER LEFT CORNER OF CAPT SLIDING WINDOW. ACCOMPLISHED INSPECTION CHECK, FOUND ONLY AFT LOWER LINK ARM OUT OF LIMITS. ADJUSTED LINK ARM PER AMM. PRESSURIZED AIRCRAFT PER JRH, NO LEAKS NOTED.SDR UALA2011033001521Power Supply · faultyM33097 EMER PWR SUPPLY DID NOT KEEP IT'S LIGHTS ILLUMINATED FOR 15 MINUTES AT R2 DOOR. REPLACED POWER SUPPLY, OP CHECK GOOD.SDR UALA2011033001520Power Supply · faultyM33406 EMER PWR SUPPLY DID NOT KEEP IT'S LIGHTS ILLUMINATED FOR 15 MINUTES AT L3 DOOR. REPLACED POWER SUPPLY. OP CHECK GOOD.SDR UALA2011033001541Slide Raft · damagedTHE NR 4 RT PAX ENTRY SLIDE-RAFT BACK-BOARD HAS PUNCTATION (0.4"*0.5").SDR UALA2011033001540Slide · crackedTHE NR 4 LT PAX ENTRY SLIDE-RAFT BACK-BOARD SURFACE CRACKED (0.7").SDR UALA2011033001539Window · defectiveFOUND MILKY WHITE AREA IN WINDOW NR 1 LT UPPER EDGE IN COCKPIT. REPLACED WITH NEW WINDOW PER AMM, WINDOW HEAT CONTROL SYSTEM TESTS OKAY.SDR UALA2011033001538Window · defectiveFOUND MILKY WHITE AREA IN WINDOW NR 3 RT AROUND EDGE IN COCKPIT. REPLACED WITH NEW WINDOW PER AMM, WINDOW HEAT CONTROL SYSTEM TESTS OKAY.SDR UALA2011033001537Window · defectiveFOUND MILKY WHITE AREA IN WINDOW NR 3 LT AROUND EDGE IN COCKPIT. REPLACED WITH NEW WINDOW PER AMM, WINDOW HEAT CONTROL SYSTEM TEST OKAY.SDR UALA2011012100362Module · inoperativeRT FWD FUEL PUMP INOPERATIVE. REPLACED RT FWD PUMP SWITCH MODULE ASSY. OPS CHECKED PUMP OPERATION OK.SDR UALA2011011700251Circuit Card · faultyEAI CARD L STATUS MSG AT GATE. NO TIME TO FIX, COMPLIED WITH MEL AND DEACTIVATED LT ENG AI VALVE OPEN. RESET CARD, NO HELP. SUGGEST CHANGING EAI VALVE. REPLACED EAI CARD AND RESTORED SYSTEM.SDR UALA2010111604246Actuator · faultyAIRCRAFT HEATH MONITORING HAS DOWNLINKED AN ENG EEC C1 L MSG ASSOC WITH 75-50391 MAINT MSG. C/B PULLED FROM REPLACEMENT OF 2.5 BLEED ACT. REPLACED NR 1 ENG 2.5 BLEED ACTUATOR. ACCOMPLISHED TEMPORARY RIG OF 2.5 PER MM. RESET PULLED CB'S PER MM.SDR UALA2010100803735Processor · failedDURING FUELING, FUELING PANEL BLANKED, FLIGHT DECK BLANK AS WELL. REPLACED FUEL QTY PROCESSOR UNIT, CHECKS OK.SDR UALA2010092403548Probe · faultyFQTY RT MAIN DISPLAY BLANK. RELAY RT CTR FUEL PUMP INHIBIT IN P210 IS NOT IN COMMANDED POSITION. ACTIVE MESSAGE 28-12017. DID STEPS A&B FIM 28-22 TASK 839, NO HELP. REPLACED RH #17 TANK UNIT, AND LH #14, BITE CHK GOOD.SDR UALA2010071902568Unknown · odorF/A CONFIRMED BY 2 OMC BURNING RUBBER - ELECTRICAL SMELL NEAR ROW 6 NOW DISSIPATED. ODOR COMES AND GOES. ROW 6AB STATIC IN AUDIO. ACCOMPLISHED SEAT CABLE AND SEB CK 5AB-6AB. NO OBVIOUS ODOR. WIRING TO SEB CHECKS OK. AUDIO SYSTEM OPERATION NORMAL.SDR UALA2010071202461Indicator · faultyRUDDER TRIM SCALE EXTREMELY DIM. REPLACED RUDDER TRIM IND. SYS GROUND CHECKS NORMAL.SDR UALA2010071202462Dump Valve · leakingFUEL DRIPPING FROM LEFT JETTISON VLV NOZZLE AFTER REFUELING. DUE TO RECENT HISTORY, INOPED LEFT JETTISON VLV PER MEL. LEFT VLV CLOSED, C/B`S PULLED-CAPPED. REPLACED LT JETTISON VALVE. OPS CK GOOD.SDR UALA2010070602376Sensor · faultyLOUD PNEUMATIC NOISE RUMBLE IN AREA OF DOOR 3 AFTER STARTER CUT-OUT, APU IN USE. FLT CREW SOP IS TO START BOTH ENGINES AT THE SAME TIME. APPLIED MEL APU PNEUMATICS INOP FOR ENGINE START. REPLACED APU SURGE VALVE AND APU CHECK VALVE AS REQUIRED PER LM. OPERSDR UALA2010062802285Clamp · unsecureAPU BLEED AIR CAUSING VIBRATION - NOISE DURING ENGINE STARTS. LOCKED APU BLEED VALVE CLOSED. REMOVED LT ISOLATION VALVE, LOOKED INSIDE DUCT, NO DEBRIS FOUND. RE-INSTALLED VALVE NOTICED WITH APU BLEED ON THERE IS A SMALL CONSTANT VIBRATION FELT IN THE APU BLSDR UALA2010061002033Idg · faultyELEC GEN OFF LT GENERATOR CONTROL BREAKER (GCB) OPEN OR GENERATOR CONTROL SWITCH OFF AND ENGINE NOT SHUTDOWN. DISCONNECTED LT IDG AND DF IAW MEL 2411B. WKD WITH FLT CREW AND ACP'D MAINT PORTION OF MEL. LT IDG OIL TO BE CHANGED WHEN THIS DEFERRAL IS CLEARED.RESDR UALA2010061002032Gcu · faultyGEN CONTROL L IS OFF. ATTEMPTED 1 RESET IAW CHECKLIST, NO HELP. REPLACED LT ENG GCU, RAN ENG GCU OPS CHECKED GOOD.SDR UALA2010052401755Light · failedINTERIOR EMERGENCY CEILING LT (AREA LTS) INOP ABOVE SEATS 29AB-35AB. REPLACED LAMPS AND REPLACED BROKEN COVER ON 29AB, 32AB AND 35AB, NO HELP. REPLACED LIGHT ASSY M33400. OPS CHKD, OKAY.SDR UALA2010052401754Battery Pack · inoperativeINTERIOR EMERGENCY CEILING (AREA LTS) INOP ABOVE SEATS 1AB-6AB AND FWD OF MID LAV (LT). REPLACED LAMP ON 1AB,3AB,5AB AND L MID LAV LOCATIONS, NO HELP. REPLACED BATTERY PACK AND LT ASSY. OPS CHK'D, OKAY.SDR UALA2010043001455B-Nut · leakingLT PRSOV MESSAGE. FOUND LINE LEAKING AT THE PRSOV WHEN USING PNEUMATIC TESTER. REMOVED LINE AND FOUND THE "B " NUT SEVERELY GALLED AND ALSO THE UNION GOING INTO THE VALVE. MFG NEW LINE AND PRESSURE TESTED IT OK. PRSOV WORKED NORMALLY USING THE PNEUMATIC TESSDR UALA2010042601389Rod · bentFOUND RT ENG CROSS TIE SUPPORT ASSY ROD BENT, AND BOTH LEGS ATTACH BOLTS SHEARED. REPLACED HOOP TIE SUPPORT ROD AND BOLTS.SDR UALA2010041901300Converter · faultyBOTH BACK-UP GEN OFF LINE. RESET AND THEY RESTORED. REPLACED BACKUP CONVERTER M24004. INSTALLED SOFTWARE AND ACCOMPLISHED ENGINE RUN. CKS OK.SDR UALA2010041201217Shutoff Valve · faultyBLEED HPSOV L LT ENGINE BLEED HIGH PRESSURE SHUTOFF VALVE (HPSOV) FAILED OPEN OR CLOSED, OR LT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. DUE TO FLIGHT CREWS REPORTING 'BLEED PRSOV L' STATUS MESSAGE WITH NUMEROUS COMPONENTS PREVIOUSLY REPLACED, ACP PNESDR UALA2010041201203Controller · faultyFOUND ONE OF THE SOLENOID ON THE HPFAC SHORTING. REPLACED HPFAC. NEED ENG AIR SUPPLY OPS TEST. ACCOMPLISHED ENG AIR SUPPLY OPS TEST, PARAMETERS ALL NORMAL. NO MESSAGES.SDR UALA2010041201196Controller · faultySTATUS MSG 'BLEED PRSOV L' DISPLAYED ON ARRIVAL. REPLACED LT ASCPC. SYS OPERATION NORMAL.SDR UALA2010040901191Controller · faultyBLEED OFF ENG L EICAS MSG. CYCLED BLEED SWITCH, NO HELP. ACFT RTBL DUE TO HISTORY. PRSOV LOCKED IN CLOSED POSITION PER MEL. REPLACED PRSOVC, RAN ENGINE PER JRH, CHECKED NORMAL.SDR UALA2010040601154Shutoff Valve · faultySTATUS MESSAGE ON EICAS, BLEED PRSOV L. PRSOV LEFT NR 1 INOP IN THE CLOSE POSITION. PER MEL 36040 ENGINE IDLE SELECTION SYSTEM IS CONSIDERED INOP. INSTALLED NEW PRSOV AND PRSOVC PER AMM AND PERFORMED TEST. SYSTEM OPERATES NORMALLY.SDR UALA2010031200838Seal · damagedFUEL SEEP FOUND AT APU DC PUMP AT REAR SPAR MATING SURFACE LT WHEEL WELL. NOT NECESSARY TO REPAIR IMMEDIATELY. EXAMINE FREQUENTLY TO MAKE SURE IT DOES NOT GET LARGER. TO BE REPAIRED AT NEXT LAYUP. REPLACED 2 EA. APU DC PUMP SEALS. (ITEMS 70 & 75) NO LEAKSDR UALA2010030100721Buss · failedRIGHT TRANSFER BUSS FAILED 10 MILES FROM AIRPORT. CREW REPORTED RT TRANSFER BUSS FAILED WHEN APPROACH MODE WAS SELECTED ON MCP. FOUND FAULT MESSAGE 24-120-91. PER FIM REPLACED BACKUP GENERATOR CONVERTER.SDR UALA2010022200637Filter · leakingOIL QUANTITY IND, FLIGHT DIVERTED. AIR OIL HEAT EXCHANGER HAS AN OIL LEAK FOR RIGHT ENGINE. RIGHT ENG HEAT EXCHANGER REMOVED AND AWAITING FOR SERVICEABLE PART. STILL OPEN TO COVER INSTALLATION OF AIR-OIL HEAT EXCHANGER. RAN ENGINE HIGH POWER. LEAK CHECK GOSDR UALA2010011100107Cable · faultyFOUND SATCOM HIGH GAIN INOP. ORDERED HIGH POWER RELAY-K23001 AND CABLE BETWEEN HPA AND HIGH POWER RELAY. REPLACED CABLE.SDR UALA2009113003682Cable · faultyNUMEROUS SAT VOICE LOST MESSAGES. REPLACED CABLE ASSY W23101, P/N 513881-504, PORT SMHGA LEFT ANT TO PORT BSU. OP CKS AND SAT VOICE OP CKS NORMAL. REPLACED CONNECTOR DM23088B. CANNOT REPLACE ANY MORE CONNECTERS ON THIS CABLE W6185 DUE TO LENGTH OF CABLE.
Back to N213UA