N2142J
Service difficulty reports · 138
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2142J' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2142J' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA2026093000916Sense Line · damagedFLT 353, BOS-DUB. (ETOPS), AFTER TAKEOFF AND THRUST REDUCTION ENG 1 SENSOR FAULT EICAS MESSAGE, ENGINE 1 SENSOR FAULT. REMOVED & REPLACED SHEARED BURNER PRESS SENSE LINE ( AS11) PER AMM 73-21-23, PERFORMED ENG RUNS FOR OPS CHK + LEAK CHECKS PER AMM 71-00-SDR YENA2026091400798Generator · malfunctionedFLT 842, DUB-JFK. (ETOPS) AC GEN CLASS 2 MX MSG ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY FAULT(S) INDICATED BY GPCU OR AC GEN). OPENSDR YENA2026081400670Fluid · lowFLT 841, JFK-DUB. (ETOPS) "RAIN REPELLANT LOW ( RAIN REPELLENT SYSTEMS )." (SUPPLEMENTAL INFORMATION TO FOLLOW).SDR YENA2026080500650Control Unit · failedFLT 1926, LGW-BOS. (ETOPS) WXR/PWS PULL-UP SAFETY LOCK TOGGLE SWITCH IN INOP SWITCH SHOULD REQUIRED PULL TO GO FROM '1' TO 'OFF' BUC CAN BE KNOCKED 'OFF' WITHOUT PULLING; R/R WX RADAR CONTROL UNIT IAW AMM 34-41-12.SDR YENA2026072700623Warning Message · illuminatedFLT 1926, LGW-BOS. (ETOPS) ENGINE 1 HEAT SYSTEM DEGRADED ECAM ON TAXI TO GATE EXTINGUISHED ON ENGINE SHUT DOWN ( HEAT SYS DEGRAD CAUTIONS ON ECAM E/WD) OPEN.SDR YENA2026070900525Indicator · inoperativeFLT # 1177, BOS-LAS. (ETOPS) "FLT ATT DIRECT VIEW SYS INOP ( E-DIRECT VIEW SYSTEM )"SDR YENA2026070600513Warning Message · illuminatedFLT # 8450, EWR-BOS. (ETOPS) "ENG 1 BLEED INOP ( BLEED AIR SUPPLY SYSTEMS )" (SUPPLEMENTAL INFORMATION TO FOLLOW).SDR YENA2026070600512Warning Message · illuminatedFLT # 8450, EWR-BOS. (ETOPS) "PACK 1 INOP ( PACKS )" (SUPPLEMENTAL INFORMATION TO FOLLOW).SDR YENA2026070700521Unknown · odorFLT# 2074, LAX-EWR. CABIN AND COCKPIT ODORS DURING CLIMB OUT, ODORS DISSIPATED AT CRUISE THEN ODORS REUMED DURING DESCENT, ODORS CONSISTENT WITH DIRTY SOCK SMELL.; C/W INFO NOTICE 2017-T015M , FOUND ENG #1 AS SOURCE OF ODOR EVENT. R/R ENG #1 SEE LP 4756175-2. SDR YENA2026070200507Unknown · odorFLT #2074, LAX-EWR. CABIN AND COCKPIT ODORS DURING CLIMB OUT, ODORS DISSIPATED AT CRUISE THEN ODORS REUMED DURING DESCENT, ODORS CONSISTENT WITH DIRTY SOCK SMELL. (SUPPLEMENTAL INFORMATION FOLLOW)SDR YENA2026062900494Actuator · inoperativeFLT # 1524, JFK-LAX. (ETOPS) PACK 2 REGULATOR SYSTEM IS INOP. R & R PACK #2 P2 RAM AIR ACTUATOR FIN 28HH, OPS CHK GOOD. SEE LP 4756177-2 (IN REF TSM 21-61-00-810-850-A, AND PREVIOUS MX TROUBLESHOOTING, AND MCC REQUEST. R/R PACK #2 P2 RAM AIR IN ACTUATOR (FIN:SDR YENA2026062900492Tube · rupturedFLT 124, LAX-JFK. (ETOPS) UPON INSPECTION, DURING OPS CHK, FOUND PACK 1, ACM ANTI ICE TUBE RUPTURED, R & R PACK 1 ACM ANT ICE TUBE IAW AMM 21-52-21. OPS & LEAK CHK GOOD.SDR YENA2026062900501Unknown · odorFLT 124, LAX-JFK. ODOR IN FLIGHT DECK DURIGNG DESCENT 4000' AND BELOW DIRTY SOCK ODOR. CABIN AIR QUALITY EVENT REPORTING FORM SUBMITTED ; REF INFO NOTICE 2-17-T015M. REF TSI MDDR #622005 UNDER WO # 1503431. ACCOMPLISHED ENG NR 1 BORO INSP W/ NO FINDINGS. ACCOSDR YENA2026062900500Unknown · odorFLT 1223, JFK-LAX. ODOR IN FLT DECK & CABIN DURNING APP AROUND 3000 FEET. COMPLIED WITH INFORMATION NOTICE 2017-T015. STEP 1, ISOLATED FAULT TO TYPE 10, SUSPECT LOCAL FIRE IN VICINITY OF AIRPORT, PER TSM 05-50-00-810-085-B/ TSM 05-50-00-810-085-D. AIRCRAFT ISSDR YENA2026062200485Controller · failedFLT 215, JFK-SFO. (ETOPS) "AIR PACK 2 REGULATOR FAULT ( AIR COND PACK RAM AIR INLET FLAPS ) ; FOLLOWED TSM 21-61-00-810-850-A ACTUATOR OPS CHK GOOD, PERFORMED REACTIVTION OF RAM AIR INLET FLAP IN REF W/ AMM 21-61-00-040-002-A DID R/R OF CACS ( 57HH) IAW AMM 2SDR YENA2026061700481Fire Bottle · failedFLT # 323, JFK-LAX. (ETOPS) "FWD CARGO BTL 2 FAULT ; R/R FWD CARGO BTL 2 ( 4010WX) IAW AMM 26-23-41. OPS CHECK GOOD. NO FAULTS PRESENT A/C OKAY FOR CON'T SVC REF L/P # 4542148 ITEM # 1 + # 2 FOR R/R OF CATRIDGE SQUIB FOR FWD BTL 2 ( 4010WX)."SDR YENA2026031600312Warning Message · false activationFLT # 177 BOS -LAS (ETOPS). " ECAM STATUS AIR BLEED MX MSG ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 1) FAULT(S) INDICATED BY AIR BLEED. FOLLOWED FIM 36-00-00-810-804-A. OPS CHECK GOOD. NO RECENT OR CURRENT ACTIVE FASDR YENA2026021100163Fire Loop · failedFLT 1115, JFK- SFO (ETOPS). ENG 2 FIRE LOOP A FAULT, ENGINE FIRE DETECTION SYSTEMS 1, LOOP A . REMOVED AND REPLACED ENG 2 CORE LOOP A FIRE OVERHEAT DETECTOR AND OPS CHECKED PER AMM 26-12-17, OPS CHECK OK AND FAULT CLEARED. MDDR CLEARED PLACARD REMOVED, MX-SDR YENA2026020900157Pump · failedFLT # 2233 BOS- SFO (ETOPS). " #1 ENG HEAT SYS DEGRADE ( HEAT SYS DEGRAD CAUTIONS ON ECAM E/WD ).; REMOVED AND REPLACED ENG FUEL / OIL HEAT EXCHANGER BYPASS VLV IAW AMM 79-21-09 NO LEAKS NOTED ENGINE RUN PERFORMED. ALL PARAMETER NORMAL MX-4 UPDATED PLACARD RESDR YENA2026020200108Actuator · faultedFLT 1115, JFK- SFO (ETOPS). NR 1 PACK 1 REG FAULT ON ECAM STATUS PAGE ON TAXI IN ( AIR COND PACK RAM AIR INLET FLAPS ). AIR BLEED ECAM MAINTENANCE MEMO ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 1) FAULT INDICATED BYSDR YENA2026020200105Engine · no discrepancyFLT 2116, SFO -JFK (ETOPS). ENGINE NR 1 MINOR FAULT ON ECAM. ( MINOR FAULT CAUTIONS ON ECAM EWD ). PERFORMED W03 HARNESS INSPECTION AND EEC1 TEST REF TSM 79-33-00-810-841-A, NO FAULTS FOUND OK FOR SVC. MDDR CLR. MX 4 UPD. PLACARD REMOVED.SDR YENA2026012800077Fcu · failedFLT 2124. LAX-JFK ( ETOPS). CAT II STATUS MSG ( CATEGORY IIIB NOT AUTHORIZED ).;AUTOTHRUST FUNCTION INOP ( AUTOTHRUST FUNCTION WITH SOFT GO-AROUND ). REMOVED AND REPLACED FCU PER AMM 22-81-12. OPS CHKD GOOD . MDDR CLEARED MX-4 UPDATED PLACARD REMOVED.SDR YENA2026012200061Outflow Valve · faultedFLT 115 JFK - SFO (ETOPS). VENT AVNCS SYS FAULT ON ECAM ( SKIN AIR OUTLET VALVE (AVIONICS) ).; (RESOLVED ON W/O: 1470897 TASKCARD: NR-00003 ) REMOVED AND REPLACED SKIN AIR OUTLET VALVE 22HQ W/ REF TO AMM 21-36-53 OPC600D. MDDR CLRD MX4 UPDATED PLACARD REMOVESDR YENA2026010500008None · noneFLT # 872 SLC - JFK (ETOPS) CORRECT TOTAL TIME AND TOTAL CYCLES (SUPPLEMENTAL INFORMATION)SDR YENA2026010200008Relay · faultedFLT 872 SLC-JFK (ETOPS) PER TECH SUPPORT REQUEST REPLACE RELAY-APURV CMND (21HV).; REMOVED AND REPLACED RELAY APURV CMND (21HV) OPS CHECK GOOD.IAW ESPN-20-46-50. OPENSDR YENA2026010200005Outflow Valve · faultedFLT #1487 BOS-LAX (ETOPS), VENT AVIONIC FAULT SKIN AIR OUTLET VALVE ( SKIN AIR OUTLET VALVE (AVIONICS).; PERFORMED BITE TEST OF AEVC IAW AMM 21-26-00. TEST OK.SDR YENA2025122601262Bypass Valve · warning messageFLT 133 BOS- SFO ( ETOPS). (ECAM INDICATION 3) ON BLEED PAGE B) PACK TURBINE BYPASS VALVE POSITION).; REPLACED ASCS 2 (57HH) PER TECH SUPPORT REQUEST. OPS CHECK GOOD. WORK DONE IAW AMM 21-61-34-400-002-A. MDDR CLOSED, MX-4 UPDATED, PLACARD REMOVED.SDR YENA2025122201237Valve · failedFLT # 348 LAS -JFK (ETOPS) "REF MDDR # 602329 PACK 1 INOP; REMOVED AND REPLACED PACK 1 FLOW CONTROL VALVE PER AMM 21-51-51. OPS CHK GOOD. NO FAULTS NOTED. MX-4 UPDATED. PLACARD RMD. MDDR CLEARED.SDR YENA2025122201235Regulator · malfunctionedFLT #511 JFK-LAS (ETOPS) "PACK 2 REGULATOR FAULT ECAM. RESET PACK 2 CONTROLLER IAW AMM 21-52-21. PERFORMED GROUND VERIFICATION IAW AMM 21-58-00 WITH NO DEFECTS NOTED REFERENCE LP 4500499 ITEM 1 FOR ETOPS VERIFICATION FLIGHT REQUIREMENTR FOR PACK 2."SDR YENA2025121601224Not Reported · not reportedFLT # 2233 BOS-SFO (ETOPS). " (PACKS); FOR CORRECTIVE ACTION REF LP 4500480 ITEM 1 MDDR CLEARED MX-4 UPDATED PLACARD REMOVED".SDR YENA2025121601223Actuator · failedFLT # 2233 BOS-SFO (ETOPS). " ( AIR COND PACK RAM AIR INLET FLAPS ); REMOVED AND REPLACED ACTUATOR- INLET IAW AMM 21-61-51 OPS CHK OK GOOD, MDDR CLEARED MX-4 UPDATED".SDR YENA2025120901181Controller · failedFLT#411, JFK-LAS. (ETOPS) AIR PACK 1 REGULATOR FAULT ( AIR COND PACK RAM AIR INLET FLAPS ); REMOVED AND REPLACED ACSC 1 IAW AMM 21-61-34. OPS CHECK GOOD. NO FAULTS.SDR YENA2025120901182Fcu · failedFLT 2724, LAX-JFK. (ETOPS) ND MAP RANGE ONLY WORKS ON 20 AND 80, EFIS CONTROL PANEL ND RANGE SELECT. REMOVED AND REPLACED FLIGHT CONTROL UNT IAW AMM 22-81-12. OPS CHK GOOD. MX-4 UPDATED. PLACARD REMOVED. MDDR CLEARED.SDR YENA2025111001097Gcu · faultedFLT 1591, JFK-LIR. (ETOPS) CLASS II MAINTENANCE AC GEN ( CLASS II MX MSG - GPCU OR AC GEN ); REMOVED AND REPLACED NR 2 GCU IAW AMM 24-22-34. OPS CHK GOOD NO FAULT MSG PRESENT AT THIS TIME MX-4 UPDATED PLAC REMOVED.SDR YENA2025102101051Relay · faultedFLT#353, BOS-DUB. (ETOPS) CLASS 2 AIRBLEED MESSAGE ON THE STATUS PAGE. ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 1) FAULT(S) INDICATED BY AIR BLEED); (RESOLVED ON W/O: 1448775 TASKCARD: NR-00002) REPLACED RELAY 21HV ISDR YENA2025101601038Warning Message · illuminatedFLT 1080, EDI-BOS. (ETOPS) CLASS 2 AIR AIR BLEED, CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 1, FAULT INDICATED BY AIR BLEED; NO FAULTS OR ECAM MESSAGES UPON ARRIVAL TO A/C NO FAULTS IN PFR PERFORMED TSM 36-00-00-810-8SDR YENA2025101401029Warning Message · false activationFLT#188, LAX-BOS. (ETOPS) AC GEN CLASS II ( CLASS II MX MSG - GPCU OR AC GEN ); FOLLWED TSM 24-22-00-810-832A BITE TESTS PASSED NO ACTIVE MSGS MDDR CLEAR MX-4 UPDATED.SDR YENA2025091500927Heater · failedFLT#1926, LGW-BOS. ANTI ICE LEFT WINDSHIELD HEAT ECAM MSG @ ABOUT 4000 FT.; REMOVED AND REPLACED WHC 31 IAW AMM 30-42-34-400-001-A. OPS TEST OK.SDR YENA2025009000906Unknown · odorFLT#1023, JFK-LAX. (ETOPS) "CONUS REST DUE TO ODOR EVENT. OPENSDR YENA2025082800895Tube · brokenFLT#2104, BOS-BOS. "FOUND ANTI-ICE TUBE ON RH ACM BROKEN; REMOVED AND REPLACED RH ACM ANTI-ICE TUBE PER AMM 21-52-21, LEAK CHECK OK. "SDR YENA2025082600879A/C Pack · odorFLT 2104, BOS-BOS. IMMEDIATALLY AFTER TAKE OFF, THE FLIGHT SMELLED ABNORMAL FUMES. CONTACTED DX MTC TO DISCUSS, MTC ADVISES TO SWITCH PACKS ON - OFF TO ISOLATE. DETERMINED IT WAS FROM PACK 2. AIR RETURN DUE TO ETOPS RESTRICTION, COMPLIED WITH INGO NOSDR YENA2025072200744Valve · failedFLT#841, JFK-DUB. (ETOPS) "COND TRIM AIR SYS FAULT TRIM AIR HI PRES; REMOVED AND REPLACED TRIM AIR VALVE REF AMM 21-63-00 OPS CHECK GOOD."SDR YENA2025070700685Generator · warning messageFLT#2104, BOS-LGW. CLASS II MAINTENANCE AS GEN ON STATUS PAGE AFTER ENG SHUT DOWN ( CLASS II MX MSG - GPCU OR AC GEN); PERFORMED BITE TEST OF THE EGPS IAW AMM 24-41-00 BITE TEST GOOD MDDR CLEARED PLACRD REMOVED.SDR YENA2025062000636Warning Message · illuminatedFLT#687, BOS-LAX. (ETOPS). CROSS BLEED MANUAL CONTROL ECAM UPON TURNING ON APU BLEED; PERFORMED OPS CHECK OF XBLEED VALVE PER 36-12-00 OPS CHECKS GOOD MX4 UPDATED PLACARD REMOVED. ( CROSS BLEED VALVE ).SDR YENA2025041400397Check Valve · wornFLT#1124, LAX-JFK. (ETOPS) ON DESCENT PASSING FL180 ENG 2 AIR SYS FAULT ECAM ANN AND QRH PROCEDURE COMPLETED -EVENTUALLY CLEARED; REF TSM 75-20-00-810-818-A #2 ENG BUFFER AIR CHECK VALVE WAS FOUND SEVERELY WORN REPLACED #2 ENG BUFFER AIR CHECK VALVE IAW AMM 7SDR YENA2025040700369Sensor · failedFLT#623, JFK-LAX. (ETOPS) 'ENG 2 AIR SYS FAULT ECAM ATCRUISE FL 340; REMOVED AND REPLACED BUFFER AIR VALVE PRESSURE SENSOR FIN 4057KS. REF AMM 75-26-22-400-801-A. REF HIGH POWER ASSURANCE ON ENG #2 LOG PG 4190431-1 (PERFORMED A HIGH POWER ASSURANCE TEST ON #2SDR YENA2025040400365Buffer Valve · failedFLT#2073, JFK-LAX. (ETOPS) 'ON DESCENT ENG 2 AIR SYS FAULT; ACCOMPLISHED TSM 75-26-00-810-818A STEP 7 REMOVED AND REPLACED VALVE BUFFER AIR PER AMM 75-26-02-000-801 AND 75-26-02-400-801, LEAK CHECK AND ENG ABOVE IDLE 80% N1 REQUIRED (PERFORMED TEST 17 TEST ABOSDR YENA2025040200358Solenoid · faultedFLT#8424, LAX-JFK. (ETOPS) ' ENG 2 AIR SYSTEM FAULT; PER TSM 75-26-00-810-818-A, REMOVED AND REPLACED ENG #2 BUFFER AIR VALVE SOLENOID IAW AMM 75-26-04. PERFORMED TEST NO.3-IDLE POWER TEST IAW AMM 71-00-00-720-811 AND PERFORMED HIGH POWER ASSURANCE TST IAW AMMSDR YENA2025030700240Warning Message · illuminatedFLT#724, LAX-JFK. (ETOPS).' CLASS 2 FUEL MSG ON ECAM ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 1) FAULT(S) INDICATED BY FUEL ); PERFORMED BITE TEST OF FLSCU (9QJ) IAW AMM 28-46-00-740-001. NO FAULTS OR ECAM MSGS SHOWNSDR YENA2025021800165Slide · unknownFLT#288, LAX-BOS. 'L OVERWING SLIDE DEPLOY; REMOVED AND REPLACED OVERWING SLIDE IAW AMM 25-62-42.'