N285WN
Service difficulty reports · 318
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N285WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N285WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023053143926Seat Track · corrodedCORROSION ON SEAT TRACK CROWN STA 578-580 ON TOP; 680-682 ON TOP RBL 25; WL 208.<[01] SRM 53-00-52-1A-1 IS APPLICABLE ALLOWABLE DAMAGE; UPDATED TEBLE.;[02] VERIFIED CORRECTIVE ACTION 1.;[03] UPDATED P/N;[04] REMOVED CORROSION ON SEAT TRACK CROWN STA 578-580 ONSDR SWAA2023053143529Sign · brokenLAV A EXIT SIGN COVER IS BROKEN ON AFT LOWER WALL.<[01] REMOVED AND REPLACED LAV-A EMERGENCY EXIT SIGN ON AFT WALL BY FED PER AMM 33-51-01-960-802; 3.C EXCEPT FOR FOR STEP 3.C.(7); OPERATIONAL TEST.;[02] COMPLETED STEP 1;[03] VERIFIED CORRECTIVE ACTION ITEM 1-SDR SWAA2023053142519Gusset · crackedFORWARD CARGO BAY GUSSET AT BS 500D STRINGER 19 R/H IS CRACKED<[01] REMOVED CARGO BAY R/H GUSSET AT BS 500D STR 19 PER SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED NEW GUSSET BS 500D STR 19R PER SRM 51-40-05-0G-0 AND DWG 143A7902. OK TO INSTALL GUSSET;[03] VERIFSDR SWAA2023053143125Angle · corrodedCORROSION AFT CARGO BAY ATTACH ANGLE UNDER SHIELD HAS MULTIPLE AREAS UNDER NUT PLATES BS767 TO BS787 RBL21 WL156<[01] CORROSION ON ANGLE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED DAMAGEDSDR SWAA2023053143126Shield · corrodedCORROSION AFT CARGO BAY SHIELD FWD OF CARGO DOOR AROUND MULTIPLE NUT PLATE HOLES BS767 TO BS794 RBL22 WL156<[01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED DAMAGE AFT SDR SWAA2023060142228Panel · crackedCRACKED BREAK PANEL STA 540; BL0-LBL 25; WL 208.<[01] UPDATED MEASUREMENT TABLE;[02] LOCATED AND DRILLED NEW BREAK PANEL AT STA 540; BL 0 - LBL 25; WL 208 IAW SRM 51-40-05-0G-0 AND AIPC 53-42-11-66. OK TO INSTALL;[03] VERIFIED CORRECTIVE ACTION 2<BR>OK TO INSTSDR SWAA2023060142230Angle · crackedCRACKED ANGLE COMMON TO CABLE GUARD INTERCOSTAL STA 694; RBL 24; WL 203. (MARKED).<[01] REMOVED AGLE AT BS 694; RBL 24;WL 203 IAW SRM 51-40-02<BR><BR>CRACK ON ANGLE IT'S OUT OF LIMITS WILL BE REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9.;[02] FABRICASDR SWAA2023053142229Crease Beam · corrodedCORROSION ON CREASEBEAM INNER CHORD STA 685-727; RBL 65; WL 208.<[01] SRM 53-40-13-1A-1 IS APPLICABLE ALLOWABLE DAMAGE; UPDATED TABLE.;[02] UPDATED P/N IN MEASUREMENTS TABLE;[03] REMOVED 21 EA FASTENERS FOR ACCESS ON CREASEBEAM INNER CHORD STA 685-727; RBL 65;SDR SWAA2023060141585Skin · debondedPANEL 191D OUTER SKIN IS DISBONDED. (MARKED)<[01] IDENTIFIED MATERIAL OF PANEL 191D IAW SRM 53-30-70-0I-1 FIGURE 1-2; ITEM 9; TABLE 2<BR><BR>DAMAGE IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-30-70-1A-1 TABLE 101; PARA 4.A(4)<BR><BR>REPAIR TO BE ACCOMPLISHED SDR SWAA2023060141589Skin · debondedPANEL 194FR OUTER SKIN HAS A DISBOND. (MARKED)<[01] IDENTIFIED MATERIAL OF PANEL 194FR IAW SRM 53-60-70-0I-1 FIGURE 1-2; ITEM 2; TABLE 2<BR><BR>DAMAGE IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-60-70-1A-1 TABLE 101; PARA 4.A(4)<BR><BR>REPAIR TO BE ACCOMPLISHSDR SWAA2023060141966Stringer · corrodedCORROSION ON STRINGER AT AREA AFT OF FWD CARGO BAY BS535 S-25R WL155. MARKED<[01] PARTIALLY UPDATED STEP 1;[02] REMOVED DAMAGED SECTION OF STRINGER 25R BETWEEN BS 500D+11' - 535 IAW SRM 53-00-03-2R-1 REP.1 AND EA 23-153-01379.;[03] VERIFIED CORRECTIVE ACTION 2SDR SWAA2023060141591Bulkhead Web · crackedCRACK ON BS 663 VAPOR BARRIER BULKHEAD PRESSURE DECK WEB AT LBL 39 BS 663 WL 156.<[01] CORRECTION ON TASK DETAIL<BR>SHOULD STATE :<BR>CRACK ON BS 663 VAPOR BARRIER BULKHEAD AT LBL 39 BS 663 WL 156;[02] PART/MATERIAL IDENTIFICATION PER SRM 57-10-10-0I-1 FIGURE SDR SWAA2023053141510Handle · looseFWD SERVICE DOOR ASSIST HANDLE LOOSE.<[01] TIGHTENED FWD SERVICE DOOR ASIST HANDEL IAW AMM 52-41-31-400-802;[02] CERTIFIED ACTION 1;[03] VERIFIED CORRECTIVE ACTION STEP 1.SDR SWAA2023053141520Handle · looseFWD ENTRY DOOR SURROUND AFT ASSIST HANDLE IS LOOSE.<[01] REMOVED AND TIGHTENED FWD ENTRY DOOR SURROUND AFT ASSIST HANDEL IAW AMM 25-21-31-420-802;[02] CERTIFIED ACTION 1;[03] VERIFIED CORRECTIVE ACTION STEP 1.SDR SWAA2023053141521Handle · looseFWD ENTRY DOOR ASSIST HANDLE IS LOOSE.<[01] FWD ENTRY DOOR ASSIST HANDLE IS TIGHT IAW AMM 52-11-31-400-802;[02] VERIFIED CORRECTIVE ACTION #1.SDR SWAA2023053141564Lens · loose#9 L/H PASSENGER CABIN OVERHEAD STOWAGE BIN; EMERGENCY EXIT LIGHT LENS LOOSE.<[01] INSTALLED LOOSE EMERGENCY EXIT LIGHT LENS; #9 L/H PASSENGER OVERHEAD STOWAGE BIN. IAW AMM 33-51-03-960-801 STEP 2.D.(C).<BR>CARD COMPLETE;[02] VERIFIED CORRECTIVE ACTION #1.SDR SWAA2023053141517Door · out of adjustFWD SERVICE DOOR REQUIRES ADJUSTMENT.<[01] ADJUSTED FSD PER AMM 52-41-00-820-801 STEPS 2.G.(1-2); I; L.(1B); Q AND R AND PERFORMED FSD SYSTEM TEST PER AMM 52-41-00-700-801 STEPS 4. E.(2) OPS CHECK TEST GOOD. <BR>TORQUE WRENCH ID: ATS1354<BR>S/N: 0414601626<BR>SDR SWAA2022081541436Bulb · burnedLIGHT BULB FOR EMERGENCY ROW 13 DEF BURNT OUT / [01] RE-LAMPED OPS CHECK GOOD IAW AMM 33-51-03SDR SWAA2022080438429Slide · looseL1 DOOR SLIDE CAME UNATTACHED. / [01] RE-PACKED AND RE-INSTALLED FWD ENTRY DOOR SLIDE IAW AMM 25-66-01.SDR SWAA2022033088462Slide · looseTHE ESCAPE SLIDE ON THE FORWARD ENTRY DOOR CAME OUT OF THE BOX ON THE DOOR. IT DID NOT DEPLOY / [01] RE INSTALLED SLIDE IN SLIDE BOX PER AMM 25-66-01SDR SWAA2022010658223Panel · damagedPANEL 193D HAS ELONGATED SCREW HOLES. ; / [01] REMOVED AND REPLACED 193 D BELLY PANEL PER AMM 53-51-21; [02] C/WSDR SWAA2021081603660Lamp · inoperativeFWD ENTRY DOOR EXTERIOR EMERGENCY LIGHT INOP. ; / [01] RELAMPED FWD ENTRY EMERGENCY LIGHT IAW AMM 33-51-04. INSTALLATION TEST IS GOOD.; [02] INSPECTED PERFORMED WORKSDR SWAA2021080299291Light · damagedR/H AND L/H PHOTO -LUMINESCENT STRIPS DAMAGED FROM STA. 270 TO STA. 606 ; / [01] REMOVED AND REPLACED FLOOR PROXIMITY LIGHTS; PHOTOLUMINESCENT STRIPS PER TASK CARD DETAILS 733-50-01 AND AMM 33-51-15; [02] JOHNNY SOLIZ (TECHNICIAN); 29-JUL-2021 12:12 UTC <BR>RESDR SWAA2021081698180Nut Plate · brokenNUTPLATE BROKEN AT FWD CARGO UNDER ENTRY WAY WEB STA 440 RBL 26 FWD INBD CORNER (MARKED) ; / [01] REMOVED AND REPLACED NUTPLATE IAW SRM 51-40-02.SDR SWAA2021081697416Battery Pack · inoperativeLEFT OVER WING DOOR INTERIOR EMERGENCY EXIT LIGHTS INOP ; / [01] REMOVED AND REPLACED LEFT OVER WING EMERGENCY LIGHT BATTERY PACK; OPS CHECKS GOOD PER MM 33-51-06; [02] INSPECTED PERFORMED WORKSDR SWAA2021081692731Angle · corrodedAFT CARGO R/H TRANSITION ANGLE FROM STA 727-767 REQUIRES REPLACEMENT ; / [01] REMOVED AND REPLACE RH TRANSITION ANGLE FROM STA 727-767 PER SRM 51-40-02;AND SRM 51-10-02.; [02] INSTALLED SECTION OF R/H TRANSITION ANGLE FROM STA . 767 TO 796 PER SRM 51-40-02 .SDR SWAA2021081692733Web · damagedAFT CARGO ENTRY FLOOR WEB PART 146A8123-25 HAS ELONGATED HOLE. WRITTEN PER INSPECTION REQUEST ; / [01] DRILLED UP AND COUNTERSUNK NEW WEB IAW SRM 51-40-02.; [02] INSPECTED AS REQUIRED. DRILLED AND LOCATED WEB; [03] THRESHOLD WEB WAS INSTALLED ON JOB CARD (JIC)SDR SWAA2021081691632Shield · crackedFORWARD CARGO FORWARD SHIELD CRACKED ; / [01] LOCATED FASTER HOLES IAW SRM 51-40-02.; [02] LOCATED FASTENER HOLES IAW SRM 51-40-02; [03] REMOVED AND REPLACED FWD SHIELD PER SRM 51-40-02; [04] INSPECTED WORK PERFORMEDSDR SWAA2021081690082Floor Support · brokenFWD CARGO HAS A BROKEN INTERCOSTAL @ STA.500B TO 500C RBL 22 ; / [01] REMOVED INTERCOSTAL.; [02] DRILLED AND INSTALLED NEW INTERCOSTAL/BAFFLE PN 143A7510-12 PER SRM 51-40-02.; [03] DRILLED AND INSTALLED NEW INTERCOSTAL/BAFFLE PN 143A7510-12 PER SRM 51-40-02.SDR SWAA2021081689189Seat Track · out of limitsCAPTAIN'S SEAT TRACKS ARE OUT OF LIMITS. ; / [01] REMOVED AND REPLACED CAPTS SEAT TRACKS PER MM 25-11-11.; [02] VERIFIED SEAT TRACKS INSTALLED PER AMM 25-11-11.SDR SWAA2021081689190Seat Track · out of limitsF/O'S SEAT TRACKS ARE OUT OF LIMITS. ; / [01] REMOVED AND REPLACED FO'S SEAT TRACKS PER MM 25-11-11.; [02] VERIFIED SEAT TRACKS INSTALLED PER AMM 25-11-11.SDR SWAA2021081689494Seat Track · damagedSEAT TRACK #1 HAS DAMAGE ON UPPER CROWN AT STA 520. ; / [01] MEASURED MATERIAL REMAIN FOUND TO BE OUT OF LIMIT AT # 1 SEAT TRACK BS 520 PER SRM 53-00-52-1A-1; [02] REMOVED CABIN FLOOR PANELS 231YF; 231ZF; 241BF; 241CF; 241EF AND 241FF PER AMM 53-21-00.; [03] RSDR SWAA2021081689496Seat Track · damagedSEAT TRACK #2 HAS DAMAGE ON UPPER CROWN AT STA 520. ; / [01] REMOVED DAMAGE; REMAINING STRUCTURE THICKNESS IS OUT OF LIMITS IAW 53-00-52-1A-1.; [02] SEAT TRACK #2; SECTION FROM STA. 480 TO STA. 520 WILL BE REPLACE .; [03] REMOVED #2 SEAT TRACK PER SRM 51-40-02SDR SWAA2021081689194Floor Panel · damagedFLOOR PANEL 241AF HAS FIBER DAMAGE ON TOP AND BOTTOM SURFACES ; / [01] REMOVED AND REPLACED CABIN FLOOR PANEL AS PER AMM 53-21-00.SDR SWAA2021081689562Angle · looseIN THE AFT CARGO BAY STATION 727 RBL14; THE FWD END OF THE FLOOR TRACK IS NOT PROPERLY SECURED; POSSIBLY CAUSING DAMAGE TO THE FASTENER HOLES ON THE ATTACH STRUCTURE ; PICTURES ATTACHED / [01] REMOVED FASTENER ; FOUND FASTENER HOLE TO BE OUT OF LIMITATION PER SDR SWAA2021070688776Plate · crackedRH WING REAR SPAR PANEL WAFFLE PLATE CRACKED JUST IB OF #6 FLAP TRACK ; / [01] REMOVED AND REPLACED WIGGLE PLATE PER SRM 51-40-02 .; [02] COMPLETED INSPECTION.SDR SWAA2021060278003Floor Panel · damagedAFT CARGO FLOOR PANEL 140BF DAMAGED BEYOND REPAIR LIMIT ; / REMOVED AND REPLACED AFT CARGO FLOOR PANEL 140BF REF AMM 25-52-10SDR SWAA2021031554480Slide · out of positionFWD ENTRY DOOR ESCAPE SLIDE EF HAS PARTIALLY FALLEN FROM SLIDE COMPARTMENT / RE-INSTALLED FWD ENTRY DOOR ESCAPE SLIDE PER MT # 725-61-06SDR SWAA2020080305133Skin · delaminatedRIGHT WING AFT OUTBOARD FLAP UPPER SURFACE DELAMINATED 3' OUTBOARD OF INBOARD EDGE; 3' UP FROM TRAILING EDGE. DAMAGE MEASURES 1.7 X 3' / RIGHT WING AFT OUTBOARD FLAP UPPER SURFACE DELAMINATED 3' OUTBOARD OF INBOARD EDGE; 3' UP FROM TRAILING EDGE. DAMAGE MEASURSDR SWAA2020080305127Battery Pack · no test1 EACH EMERGENCY LIGHTING BATTERY PACKS FAIL CAPACITY TEST. / REMOVED AND REPLACED 1 EACH EMERGENCY LIGHTING BATTERY PACK AT LOCATION M16072 PER AMM 33-51-06 AND ENG DWG 33500005.SDR SWAA2019102138030Strap · brokenAFT INBOARD FLASHLIGHT STRAP BROKEN. / R&R FLASHLIGHT STRAP PER MM.SDR SWAA2019101437751Lamp · inoperativeEMERGENCY LIGHT OUT AT ROW 5 DEF. RELAMPED LIGHT PER AMM.SDR SWAA2019091136764Battery Pack · dischargedAFT RIGHT SIDE EMERGENCY LIGHT INOP. R&R BATTERY PACK PER AMM.SDR SWAA2019082636232Motor · inoperativeELECTRIC STAB TRIM MOTOR WOULD NOT ENGAGE. / R&R HORIZONTAL STABILIZER MOTOR IAW AMM.SDR SWAA2019070234307Floorbeam · crackedMID CABIN FLOORBEAM CRACKED AT BS. 540 BETWEEN INBOARD AND OUTBOARD RIGHT SIDE SEAT TRACKS CRACKED AT FASTENER HOLES. INSTALLED FLOORBEAM IAW SRM.SDR SWAA2022031028608Baffle · crackedFWD CARGO COMPARTMENT LH BAFFLE STA 500A-500B IS CRACKED / REMOVED FWD CARGO COMPARTMENT LH BAFFLE STA 500A-500B AND REPLACED IT WITH A NEW ONE. IAW BOEING 737 DWG 143A7505 REV- AND SRM 51-70-13-2R-1 ATAG A-45009SDR SWAA2019070834647Beam · crackedR1 DOOR #4 BEAM CRACKED. R&R R1 DOOR #4 BEAM IAW SRM AND DWG.SDR SWAA2019061933937Angle · corrodedAFT OF AFT CARGO COMPARTMENT BAY FRAME/CHORD ANGLE CORRODED AT LOWER BS. 1016, BETWEEN LBL 2 TO RBL 2. / REPAIRED ANGLE IAW SRM.SDR SWAA2019062734234Floorboard · damagedPASSENGER CABIN FLOORBOARD PANEL 231XF UPPER SURFACE HAD AREAS OF FIBERS PEELING, BETWEEN BS. 537.45 TO BS. 727B. / REPAIRED FLOORBOARD PANEL 231XF IAW SRM.SDR SWAA2019062634155Floorboard · damagedAFT CABIN FLOOR BOARD 241AAF HAD UPPER PLY DAMAGED, BETWEEN BS. 887 TO BS. 1016. REPAIRED FLOOR BOARD 241 AAF IAW SRM.