N301UP
Service difficulty reports · 196
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N301UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N301UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2014060283137Skin · deformedC10 INSPECTION, DEFORMATION WAS FOUND ON RT WING NR 10 SLAT L/E SKIN AT OSS 758.24. REPAIR IAW SRM 57-43-01. REPAIR 2, REV 59.00.SDR IPXA2014060283139Floor Panel · wornC10 INSPECTION, FOUND WORN HOLE IN M/D CARGO FLOOR PANEL 241CFF, BETWEEN BS 731-834, LBL 33-55. FABRICATE THE REPLACEMENT FLOOR PANEL IAW EO 5320-9693-H.SDR IPXA2014060283138Skin · dentedC10 INSPECTION, DENT ON THE LT WING OTBD FLAP T/E WEDGE LOWER SKIN AT TA 174.23. REPAIRED IAW SRM 57-53-01, REPAIR 1, REV 59.00 AND SRM 51-70-07, GENERAL REV 59.00.SDR IPXA2013112700955Shutoff Valve · inoperativeAIR TURNBACK DUE TO FLAPS WOULD NOT MOVE WHEN SELECTED FROM 5 TO 10 DEGREES. REPLACED FLAP/SLAT SHUTOFF VALVE IAW AMM 27-51-48-022-001.SDR IPXA2013112700969Flap System · inoperativeATB -DURING CLIMB FLAPS WOULD NOT RETRACT. EMERGENCY DECLARED PERFORMED FSEU BITE IAW FIM 27-51-00-815. NO FAULTS NOTED. CYCLED FLAPS SEVERAL TIMES. SYS WORKING OK.SDR IPXA3678521Warning Message · false indicationON DESCENT, LT HYD QTY EICAS MESSAGE DISPLAYED AND OVERHEAD LIGHT ILLUMINATED. ACFT LANDED NORMALLY. EMERGENCY WAS DECLARED. INSPECTED FOR LEAKS. SERVICED LT HYD SYS IAW AMM 12-12-01-613-059. DROPPED FLAPS, CYCLED ALL FLIGHT CONTROLS SEVERAL TIMES WITH PSDR IPXA13678129Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL POS 6C HAS A .3750" HOLE 5 INCHES AFT OF YELLOW LINE. REPAIRED IAW SRM 53-00-50-2R PAR 4B.SDR IPXA13678128Floor Panel · damagedMAIN CARGO DECK POS 6L NR 3 FLOOR PANEL HAS A .2500" HOLE 25 INCHES AFT OF RED LINE. REPAIRED REF SRM 53-00-50-2R, PAR 4B.SDR IPXA13677163Floor Panel · damagedFLOOR PANEL HAS ONE INCH HOLE, BS 322. REPAIRED FLOOR PANEL IAW SRM 53-00-50-2R.SDR IPXA2676105Alternator · inoperativeON TAKE OFF, LEFT ENGINE STARTED SURGING. NO EICAS INDICATIONS. STATUS MESSAGE LT ENGINE ANALOG N2 EICAS DISAGREE, LT ENGINE CONTROL HIGH OIL TEMP INDICATIONS AND LOW OIL PRESSURE. INFLIGHT SHUTDOWN OF ENGINE. FOUND BOTH A AND B CHANNEL DATA BUSS INOPERASDR IPXA12676105Pump · crackedON T/O LEFT ENGINE STARTED SURGING. NO EICAS INDICATIONS. STATUS MESSAGE LT ENGINE ANALOG N2 EICAS DISAGREE LT ENG CONTROL HIGH OIL TEMP INDICATIONS AND LOW OIL PRESSURE. AIR TURN BACK INFLIGHT SHUTDOWN OF LEFT ENGINE. OPEN.SDR IPXA2673453Skin · delaminatedINSPECTION TYPE: 9C, RT WING INBD AFT FLAP INBD LOWER AREA FOUND DELAMINATED. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 201, SHEET 1, REV 52.SDR IPXA12673566Skin · dentedINSPECTION TYPE: 9C, LEFT WING NR 5 SLAT UPPER SURFACE DENTED. HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 201, SHEET 1, REV 52.SDR IPXA2673480Floor Panel · puncturedINSPECTION TYPE: 9C, MAIN CARGO FLOOR PANEL FOUND WITH SIX PUNCTURES AND TWELVE DENTS AT BS 1114 TO 1197 +22, LBL 33 TO 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-H AND INSTALLED AS PER AMM 53-01-06SDR IPXA2673483Skin · crackedINSPECTION TYPE: 9C, LT WING NR 3 SLAT OTBD NOSE SKIN FOUND CRACK. LT WING NR 3 SLAT OTBD NOSE SKIN IS REPAIRED IAW SRM 57-43-01-2R2, REPAIR 2, FIG 201, REV 52, REPAIR CLASSIFIED AS A MAJOR.SDR IPXA2673482Skin · damagedINSPECTION TYPE: 9C, LT WING NR 3 SLAT INBD NOSE SKIN FREEZE PLUG FOUND LOOSE. LT WING NR 3 SLAT INBD NOSE SKIN IS REPAIRED IAW SRM 57-43-01-2R2, REPAIR 2, FIG 201, REV 52, REPAIR IS CLASSIFIED AS A MAJOR.SDR IPXA2673481Floor Panel · delaminatedINSPECTION TYPE: 9C, MAIN CARGO DECK FLOOR PANEL FOUND DELAMINATED AND EIGHT PUNCTURES FROM BS 412 TO 532, LBL 33 TO 55. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR IPXA2673433Skin · damagedINSPECTION TYPE: 9C, RT WING NR 9 SLAT OTBD NOSE SKIN FREEZE PLUG FOUND LOOSE. RT WING NR 9 SLAT OTBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2, REPAIR 2, FIG 201, REV 52 .SDR IPXA2673432Skin · crackedINSPECTION TYPE: 9C, LEFT WING NR 4 SLAT INBD NOSE SKIN RIVET HOLE CRACKED. LT WING NR 4 SLAT INBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2, REPAIR 2, FIG 201, REV 52, OSS572.5. ORIGINAL MATERIAL 7075T6-0063" CRACK LENGTH 0.1285" CUTOUT SIZE 8.875"X7.5". SDR IPXA12672519Escape Rope · exposedDURING PUSH BACK MX NOTICED L1 DOOR ESCAPE ROPE EXPOSED WITH DOOR CLOSED. RESECURED L1 DOOR ESCAPE ROPE IAW AMM 25-61-03-2.SDR IPXA2672408Wire · chafedON TAKE OFF, THE RT ENGINE OIL FILTER BYPASS LIGHT ILLUMINATED. CHECKED AND REPLACED THE RT ENGINE OIL FILTER, IT WAS CLEAN. FOUND CHAFED WIRE FOR FILTER PRESSURE SWITCH. REPAIRED WIRE.SDR IPXA12671506Floor Panel · damagedHOLE IN MCD FLOOR POS 10R, FABRICATED NEW FLOOR IAW EO B767-5320-9693-H.SDR IPXA12671505Floor Panel · damagedHOLE IN MCD FLOOR PANEL, PN 143T5876-27, FABRICATED IAW EO B767-5320-9693-H.SDR IPXA12671482Floor Panel · damagedMCD FLOOR PANEL HAS HOLE POS NR 6 STA 772, LBL 6 CENTER PANEL. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12671481Floor Panel · damagedMCD FLOOR PANEL HAS HOLE RT OTBD AT POS NR5 STA 654+103, RBL 86. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12671479Floor Panel · damagedMCD FLOOR PANEL HAS HOLE RT OTBD AT POS NR 2, BS 466, RBL 86. REPAIRED IAW SRM 53-00-50-27.SDR IPXA12671477Floor Panel · puncturedMCD FLOOR PANEL HAS PUNCTURE STA 416.5, LBL 45. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12671474Floor Panel · damagedMCD FLOOR PANEL HAS HOLE AT POS NR 8, STA 1008 CENTERLINE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12671473Floor Panel · damagedMCD FLOOR PANEL HAS HOLE POS 8 AT STA 1035 RBL 80. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12671472Floor Panel · damagedMCD 2 HOLES IN LT FLOOR PANEL AT POS 2 LOCATED AT STA 491, LBL 47. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA2671275Floor Panel · damagedMCD FLOOR PANEL DAMAGED POS 12RC. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA2671274Floor Panel · damagedMCD FLOOR PANEL DAMAGED POS 12R. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA2671273Floor Panel · damagedMCD FLOOR PANEL POS 11R DAMAGED. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA2671272Floor Panel · damagedMCD FLOOR PANEL DAMAGED POS NR 9L. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA2671271Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL NR 9C DAMAGED. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA10663367Computer · inoperativeR EICAS COMPUTER SCROLLING. ALL WARNING CAUTION STATUS MESSAGES CONTINUALLY CAUSING CONTINUAL ACTIVATION OF THE MATER CAUTION AURAL LIGHT. REMOVED AND REPLACED RT EICAS COMPUTER PER AMM 31-41-02-4.SDR IPXA10661854Element · inoperativeINSP TYPE:E TOP DIVERSION - RT DUCT LIGHT ILLUMINATED EICAS MSG RT BLD DUCT LEAK DISPLAYED LIGHT EXTINGUISHED AFTER ENG BLEED AIR SUPPLY AND ISOLATION VALVES CLOSED. FIM 26-18-00, FIG 104, FOLLOWED NO FAULTS PRECAUTIONARY REPLACEMENT OF FOLLOWING ITEMS IAW ASDR IPXA0661405Guard · brokenEMERGENCY LIGHT ARMED SWITCH GUARD IS BROKEN. R & R EMERGENCY LIGHT ARMED SWITCH GUARD WITH SERVICABLE UNIT IAW IPC 33-51-08, ITEM 15. OPS CHECK OK.SDR IPXA10660986Skin · damagedINSPECTION TYPE:C, FUSELAGE (1 EA) HOLE DEEP COUNTERSUNK WAS FOUND DURING EO B767-5350-17922 ACCOMPLISHED AT LT SIDE STA 955 AFT AREA LOWEST ROW THE THRU FASTENER COUNTED FROM FWD. OPEN HOLE HFEC INSPECTED, NO CRACK FOUND. NEW BACB30NY14K26X FASTENER INSTALLSDR IPXA10661013Floor Panel · damagedINSPECTION TYPE:C, STA 1480 TO 1605 LBL 33 TO LBL 55 FLOOR PANEL FOUND 1 DAMAGED AND 13 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660977Floor Panel · damagedINSPECTION TYPE:C, STA 1112 TO 1197+22 LBL 11 TO RBL 11, FLOOR PANEL FOUND 2 DAMAGED AND 14 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660975Floor Panel · damagedINSPECTION TYPE:C, STA 977 TO 1043 RBL 33 TO RBL 55 FLOOR PANEL FOUND 1 DAMAGED AND 13 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660974Floor Panel · damagedINSPECTION TYPE:C, STA 876 TO 933 RBL 77 TO RBL 89 FLOOR PANEL FOUND 1 DAMAGED AND 8 DENT MARKS AND DEEP SCRATCH MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10660973Floor Panel · dentedINSPECTION TYPE:C, STA 933 TO 977, LBL 11 TO LBL 33, FLOOR PANEL FOUND 11 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660972Floor Panel · damagedINSPECTION TYPE:C, STA 740 TO 830, LBL 55 TO LBL 77, FLOOR PANEL, FND 3 DAMAGED AND 13 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660971Floor Panel · damagedINSPECTION TYPE:C, MCD STA 1480 TO 1605, LBL 11 TO RBL 11, FLOOR PANEL FOUND 2 DAMAGED AND 12 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660955Floor Panel · damagedINSPECTION TYPE:C, MCD STA 985 TO 1087, LBL 77 TO LBL 88, FLOOR PANEL FND 1 DAMAGED & 7 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10660937Floor Panel · damagedINSPECTION TYPE:C, MCD STA 654+22 TO 686 LBL 11 TO RBL 11 FLOOR PANEL FOUND 2 DAMAGED & 10 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10660936Floor Panel · damagedINSPECTION TYPE:C, MCD STA 764 TO 876, LBL 77 TO LBL 89, FLOOR PANEL FOUND 4 DAMAGED & 9 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10660935Floor Panel · damagedINSPECTION TYPE:C, MCD STA 533 TO STA 654+22 LBL 11, RBL 11, FLOOR PANEL FOUND 1 DAMAGED & 10 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.