N306FL
Service difficulty reports not matched to an aircraft · 24
They name N306FL, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N306FL' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N306FL' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200500011Roller · wornMAINTENANCE REPORTED R1 DOOR HARD TO CLOSE. REPLACED GUIDE ARM ROLLER PER MM 52-61-20. ADJUSTED R1 DOOR PER MM 52-41-00. REMOVED AND REINSTALLED R1 DOOR SLIDE PER MM 25-61-35. REMOVED AND REINSTALLED R1 DOOR LINER PER MM 52-41-31. REMOVED AND REINSTALLED RSDR F3LA200300191Actuator · inoperativeDURING C-7 CHECK, INSPECTION REPORTED NR 3 SLAT ACTUATOR FAILED LOCK PIN TEST. REPLACED NR 3 SLAT ACTUATOR IAW MM 27-81-41 AND ACCOMPLISHED LE SLAT ACTUATOR LOCK PIN TEST AND LE SLAT ALTERNATE SYSTEM TESTS IAW TASK CARD 5-2710 AND MM 27-81-00.SDR F3LA200300190Skin · dentedDURING C-7 CHECK, INSPECTION REPORTED CREASED DENT IN EXTERNAL FUSELAGE SKIN AT STA 368, 4 IN BELOW STR 18R. REPAIRED PER SRM 53-00-01 FIG 202.SDR F3LA200300188Flap Track · corrodedDURING C-7 CHECK, INSPECTION REPORTED CORROSION ON NR 7 OTBD FLAP TRACK ASSY. REMOVED EXISTING BUSHINGS TO EXPOSE ALL SURFACES TO INSPECTION. INSPECTED FLAP TRACK PER OHM 57-53-15. MACHINED THE HOLE FORWARD OF BUSHING NR 60 PER SOPM 20-10-01 AND SOPM 20-10-SDR F3LA200300187Battery Pack · failedDURING C-7 CHECK, INSPECTION REPORTED FWD GALLEY DOOR ESCAPE SLIDE BATTERY PACK FAILED VOLTAGE TEST. REPLACED FWD GALLEY DOOR ESCAPE SLIDE.SDR F3LA200300186Intercostal · crackedDURING C-7 CHECK, INSPECTION REPORTED MAIN DECK FLOOR INTERCOSTAL CRACKED BETWEEN STA 294 AND STA 312 AT RBL 32. REPLACED DAMAGED UPPER CHORD OF FLOOR INTERCOSTAL PER SRM 51-40-2.SDR F3LA200300185Oxygen Bottle · dischargedDURING C-7 CHECK, INSPECTION REPORTED SEAT 7 ABC OXYGEN CANISTER DISCHARGED. REPLACED OXYGEN GENERATOR CANISTER PER MM 35-22-11, PAGE 201, STEPS 1-3 AND MM 35-22-11, PAGE 401, STEPS 1-3.SDR F3LA200300184Module · faultyDURING C-7 CHECK, INSPECTION REPORTED FIRE WARN LIGHT ON P-7, ENG 1/2 OVERHEAT LIGHTS ON P-8 AND CONTROL CABIN ALARM BELL DID NOT OPERATE IN STEPS 1 G-3 AND 1 G-7 OF FIRE WARNING SYSTEM TEST. TEST 1 G-10 PASSED. REPLACED FIRE DETECTION MODULE PER MM 26-10-01SDR F3LA200300183Frame · crackedDURING C-7 CHECK, INSPECTION REPORTED FRAME CRACKED AT BIN RAIL ATTACH BRACKET HOLE, STA 907, BETWEEN STR 8L AND 9L. REPAIRED PER SRM 53-00-07 FIG 202, STEPS 1-10.SDR F3LA200300182Shear Tie · corrodedDURING C-7 CHECK, INSPECTION REPORTED SHEAR TIE IN FWD CARGO COMPARTMENT CORRODED AT STA 500B, BETWEEN STR 28L AND 28R. REPAIRED PER SRM 53-00-07.SDR F3LA200300181Shear Tie · corrodedDURING C-7 CHECK, INSPECTION REPORTED SHEARTIE IN FWD CARGO COMPARTMENT CORRODED AT STA 500B, BETWEEN STR 27R AND 28R. REPAIRED IAW SRM 53-00-07.SDR F3LA200200394Strap · corrodedDURING C-6 CHECK, INSPECTION REPORTED FILLER/STRAP CORRODED BETWEEN STA 787 AND 807, RBL 20 ABOVE STR 25-R. REPLACED FILLER/STRAP PER SRM 51-40-02 AND 51-10-02.SDR F3LA200200393Strap · corrodedDURING C-6 CHECK, INSPECTION REPORTED CORROSION ON AFT CARGO DOOR LOWER SILL STRAP, STA. 774 TO 858, RBL 20. REPLACED SILL STRAP PER SRM 51-40-07 AND 51-10-02.SDR F3LA200200392Web · corrodedDURING C-6 CHECK, INSPECTION REPORTED WEB BETWEEN STA 794.3 AND 847, STR 25-R, CORRODED AROUND SEVERAL NUT PLATE HOLES. REPLACED AND INSTALLED WEB PER SRM 51-40-02 AND 51-10-02.SDR F3LA200200391Angle · corrodedDURING C-6 CHECK, INSPECTION REPORTED CORROSION ON L-ANGLE IN FWD CARGO COMPARTMENT, STA 500D, LBL 29 TO RBL 21. REPAIRED ANGLE PER SRM 51-40-02, 51-40-05 AND 51-10-02.SDR F3LA200200396Support Angle · gougedDURING C-6 CHECK, INSPECTION REPORTED SUPPORT ANGLE ON AFT SIDE OF AFT DOOR LATCH CUTOUT GOUGED ON APU DOOR. FABRICATED NEW SUPPORT ANGLE PER SRM 52-40-02 AND 51-70-11. ALODINED AND PRIMED PER MM 51-21-41 AND SOPM 20-41-02. INSTALLED NEW ANGLE PER SRM 52-40SDR F3LA200200395Cowl Door · chafedDURING C-6 CHECK, INSPECTION REPORTED PREVIOUS REPAIR ON LT. SECTION OF APU COWL DOOR CHAFFED/GROOVED. REMOVED ADDITIONAL DAMAGE FOUND AT EDGE OF PREVIOUS REPAIR. FABRICATED NEW DOUBLER TO ENCOMPASS NEW CUTOUT IN SKIN PER SRM 52-40-02, 52-40-01, MM 51-21-41 SDR F3LA200200250Shutoff Valve · failedAIR TURNBACK. FLIGHT CREW REPORTED WING/BODY OVERHEAT ILLUMINATED IN FLIGHT. COMPLIED WITH CHECKLIST AND LIGHT REMAINED ILLUMINATED. PRESSURE IN RT DUCT 10 PSI, WHICH DECREASED TO 5 PSI WHEN THRUST LEVER REDUCED IN POWER. SHUT DOWN NR 2 ENGINE AND MONITORESDR F3LA200100123Wire · brokenPRIOR TO DEPARTURE, FLIGHT CREW REPORTED EMERGENCY EXIT FLOOR PATH WIRING EXPOSED AT ROW 15. SPLICED BROKEN WIRE PER STANDARD PRACTICES 20-30-12, PERFORMED OPERATIONAL TEST OF EMERGENCY LIGHT SYSTEM AND CHECKED OKAY.SDR F3LA200000277Fitting · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION AROUND RT. AFT LAVATORY OTBD AFT FLOOR MOUNT. MAINTENANCE FABRICATED AND REPLACED NEW FITTING PER EA 25-737-108.SDR F3LA99050Battery · dischargedDEN - DURING C-CHECK INSPECTION REPORTED R-2 EMERGENCY ESCAPE SLIDE BATTERY FAILED VOLTAGE TEST. REPLACED R-2 EMERGENCY ESCAPE SLIDE. CYCLES: 2,635. (X)SDR F3LA99049Battery · dischargedDEN - DURING C-CHECK INSPECTION REPORTED L-2 EMERGENCY ESCAPE SLIDE BATTERY FAILED VOLTAGE TEST. REPLACED L-2 EMERGENCY ESCAPE SLIDE. CYCLES: 2,660. (X)SDR F3LA99048Battery · dischargedDEN - DURING C-CHECK INSPECTION REPORTED L-1 EMERGENCY ESCAPE SLIDE BATTERY FAILED VOLTAGE TEST. REPLACED L-1 EMERGENCY ESCAPE SLIDE. CYCLES: 2,635. (X)SDR F3LA97145Wire · looseDEN - DURING SERVICE CHECK, MAINTENANCE REPORTED WIRES DISCONNECTED FROM FLOOR PROXIMITY LIGHTING AT ROW 13. MAINTENANCE RECONNECTED WIRES AND SYSTEM CHECKED OKAY. (X)