N318UP
Service difficulty reports · 125
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N318UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N318UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015061290089Sleeve · dentedINSPECTION TYPE: C, DURING MAJOR MAINTENANCE VISIT ,FOUND A DENT ON NR 2 ENG EXHAUST SLEEVE AT NAC STA 336.6, MID 9 O'CLOCK AREA REF EGAT NRC CQU05082 EVALUATED DAMAGE IAW SRM 54-42-30-1A-1, REV 62.00 INFORMATION SUBMITTED FOR ADM DENT WITHIN ALLOWABLE DAMAGE.SDR IPXA2015061490135Floor Panel · crackedINSPECTION TYPE: C9, A CRACK WAS FOUND ON M/D CARGO FLOOR PANEL 241AGF, BS 984.95 - 1087, LBL 77.5 TO 88.5. FABRICATED A REPLACEMENT FLOOR PANEL IAW EO 5320-9693-H.SDR IPXA2015061490133Skin · dentedINSPECTION TYPE: C9, A DENT WAS FOUND ON THE RT WING INBD AFT FLAP LOWER SKIN. REPAIRED IAW SRM 57-53-01-2R-1, REPAIR 1 AND SRM 51-70-10-2R-4, REPAIR 4.SDR IPXA2015050488598Skin · crackedLEFT WING OTBD AILERON UPPER SKIN CRACKED. REPAIRED REF EO B767-5750-57315-A.SDR IPXA2015040587713Floor Panel · damagedFLOOR PANEL MAIN CARGO DECK POSITION 3/4 CENTER FLOOR PANEL DAMAGED NUMEROUS AREAS BY BALL MATERIAL, PN 143T5876-49. FABRICATED FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA2015040587708Floor Panel · damagedFLOOR PANEL MAIN CARGO DECK POSITION 3/4. PN 143T5876-84, DAMAGED NUMEROUS AREAS BY BALL MATERIAL FABRICATED NEW FLOOR PANEL, PN 143T5876-84, EO B767-5320-9693-H.SDR IPXA2015020285536Floor Panel · delaminatedCOCKPIT FLOOR PANEL HAS 10 INCHES OF DELAMIMATION, FABRICATED A NEW FLOOR PANEL IAW EO B767-5320-56389-A.SDR IPXA2014071483612Unknown · unknownAT ROTATION, PITCH CONTROL FELT MUSHY. PITCH CONTROL REMAINED SLUGGISH DURING AIR TURN BACK. PERFORMED ELEVATOR CONTROL SYS OPS TEST IAW AMM 27-31-00-715-001. NO DEFECTS NOTED. PERFORMED ELEVATOR CONTROL SYS TEST IAW AMM 27-31-10-735-198 AND NO DEFECTS NOTSDR IPXA3678842Warning Light · false activationEMERGENCY DECLARED, WHILE EXTENDING FLAPS TO 5 UNITS, RECEIVED MESSAGE L/E SLAT ASYMMETRY. OPS TEST OF L/E SLAT WITH NO FAULT NOTED IAW AMM 27-81-00. ACFT OK FOR SERVICE.SDR IPXA13678660Seat Track · damagedINSPECTION TYPE:C08, FOUND WORN OUT ON THE STUD HOLE OF SEAT TRACKS AT BS 1263, RBL 11. REPAIRED IAW SRM 53-00-52, REPAIR 9, REV 56.SDR IPXA13678659Seat Track · damagedINSPECTION TYPE:C08, FOUND WORN OUT ON THE STUD HOLE OF SEAT TRACK AT BS 1500, RBL 11. REPAIRED IAW SRM 53-00-52, REPAIR 9, REV 56.SDR IPXA13678658Seat Track · damagedINSPECTION TYPE:C08, FOUND WORN OUT ON THE STUD HOLE OF SEAT TRACK AT BS 1263, LBL 77.5. REPAIRED IAW SRM 53-00-52 REPAIR 9 REV.56SDR IPXA13678657Seat Track · damagedINSPECTION TYPE:C08, FOUND WORN OUT ON THE STUD HOLE OF SEAT TRACK AT BS 1373, LBL 33. REPAIRED IAW SRM 53-00-52, REPAIR 9, REV 56.SDR IPXA13678656Seat Track · damagedINSPECTION TYPE:C08, FOUND WORN OUT ON THE STUD HOLE OF SEAT TRACK AT BS 1500, RBL 54.75. REPAIRED IAW SRM 53-00-52, REPAIR 9, REV 56.SDR IPXA13678655Seat Track · damagedINSPECTION TYPE:C08, FOUND WORN OUT ON THE STUD HOLE OF SEAT TRACK AT BS 1500, LBL 11.00. REPAIRED IAW SRM 53-00-52 REPAIR 9, REV.56SDR IPXA13678654Seat Track · damagedINSPECTION TYPE:C08, FOUND WORN OUT ON THE STUD HOLE OF SEAT TRACK AT BS 1500, LBL 33.00 REPAIR IAW SRM 53-00-52 REPAIR 9 REV.56SDR IPXA13678653Seat Track · damagedINSPECTION TYPE:C08, FOUND WORN OUT ON THE STUD HOLE OF SEAT TRACK AT BS 1500, RBL 57.75 REPAIRED IAW SRM 53-00-52 REPAIR REV.56SDR IPXA13678613Floor Panel · dentedINSPECTION TYPE:C08, FOUND DENT ON CARGO FLOOR PANEL AT BS 890, LBL 15. REPAIRED IAW EO B767-5320-9693-H.SDR IPXA2675485Floor Panel · dentedMAIN CARGO DECK FLOOR PANEL POS 5L DENTED. REPAIRED FLOOR PANEL IAW SRM 53-00-50-2R.SDR IPXA2675479Floor Panel · damagedPOS 2R MAIN CARGO FLOOR PANEL DAMAGED. FABRICATED NEW FLOOR PANEL REF EO B767-5320-9693-H.SDR IPXA11670487Computer · inoperativeON CLIMBOUT AND CRUISE MASTER CAUTION LIGHT AND AURAL STARTED TO CONSTANTLY ACTIVATE WITH NO ASSOCIATED MESSAGES. RESET MASTER CAUTION SWITCH EVERY 10 SECONDS, NO EICAS MESSAGES DISPLAYED. RT EICAS COMPUTOR HAD NUMEROUSLY DISPLAYED CAUTIONS AND WARNINGS ACTISDR IPXA1666734Skin · delaminatedINSPECTION TYPE:C, RT WING INBD AFT FLAP UPPER SURFACE INBD AREA FOUND DELAMINATED. METAL HOT BOND REPAIR PERFORMED IAW ARM 51-70-10-2R, REPAIR 4, FIG 201, SHEET 1, REV 49.SDR IPXA1666733Skin · delaminatedINSPECTION TYPE:C, RT WING INBD AFT FLAP UPPER SURFACE OTBD AREA FOUND DELAMINATION. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 201, SHEET 1, REV 49.SDR IPXA1666735Wing · debondedINSPECTION TYPE:C, RT WING INBD AFT FLAP UPPER SURFACE AT MID AREA FOUND DEBOND. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 202, SHEET 1 REV 49.SDR IPXA1666679Wedge · delaminatedINSPECTION TYPE:C, LT WING OTBD T/E FLAP, T/E WEDGE, LWR SURFACE AT MID AREA DELAMINATION. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5(A), FIG 9, REV 49.SDR IPXA1666678Wedge · delaminatedINSPECTION TYPE:C, RT WING OTBD T/E FLAP LWR SURFACE T/E WEDGE AT MID AREA DELAMINATION. FIBERGLASS PREPAGE LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5A(1), FIG 9, REV 49.SDR IPXA1666731Rib · crackedINSPECTION TYPE:C, RT WING INBD AILERON INBD HINGE SUPPORT RIB UPPER FLANGE FOUND CRACKED. RIB UPPER FLANGE REPAIRED IAW HX RS R-57-50-37081, REV A & EO B767-5740-42723-A JUST AT WS 468.11, ORG MAT DIE FORGING 7075-T73 CRK LENGTH 0.40" FINAL CUTOUT SIZE 0.80 SDR IPXA1666677Stiffener · crackedINSPECTION TYPE:C, FWD CARGO COMPT CTR TANK FRONT SPAR AT STA 785.9, RBL 10.94 VERTICAL STIFFENER FOUND CRACKED. VERTICAL STIFFENER REPAIRED IAW SRM 57-10-10-2R2. REPAIR 2, FIG 201, REV 49 JUST AT STA 785.9, RBL 10.94 ORG MAT'L BAC1518-912-2024T3511 CRACK LESDR IPXA1666676Stiffener · crackedINSPECTION TYPE:C, FWD CARGO COMPT CTR TANK FRONT SPAR AT STA 785.9, RBL 32.94 VERTICAL STIFFENER FOUND CRACKED. VERT STIFFENER REPAIRED IAW SRM 57-10-10-2R2. REPAIR 2, FIG 201, REV 49 AT STA 785.9, RBL 32.94 ORG MAT'L BAC1518-749-2024T3511 CRACK LENGTH IS SDR IPXA10661152Indicator · contaminatedON TAXI OUT LOST CAPT'S EADI, BTB TO RAMP AND EADI CAME BACK ON, PULLED INTO CHOCKS AND EHSI WENT OFF AND ON A COUPLE OF TIMES AND HEARD SOME ELECTRICAL ARCING BEHIND INSTRUMENT PANEL, SAW AND SMELLED ACRID SMOKE REMOVED CAPT'S EADI AND EHSI, VISUALLY CKD SDR IPXA10660441Floor Panel · damagedREF:D425416 MAIN CARGO COMP FLOOR PANEL INTERIM REPAIR POSITION 5L FABRICATE NEW FLOOR PANEL IAW EO B767-5320-9693G AND INSTALL.SDR IPXA10658248Floor Panel · damagedMAIN DECK FLOOR PANEL POSITION 2R DAMAGED 35"AFT OF POS 1/2 SPLIT LINE AT RBL 82 DAMAGE IS 2" X 1.5" PANEL AT POS 2R, RBL 82. REPLACED IAW EO B767-5320-9693-G.SDR IPXA09656348Fan · unknownFWD EQUIP COOLING OVERHEAT MSG. T/S REF FIM 21-58-00 FIG 115 INSP C/O EQUIPMENT COOLING SYS SUPPLY FAN & EXHAUST FAN INLET SCREEN, EQUIPMENT COOLING MANIFOLD INTER- CONNECT VALVE & MIXING MANIFOLD ALL OKAY. FWD RACK LOW FLOW DETECTOR & EXHAUST FAN REPLACED.SDR IPXA09656267Floor Panel · damagedINSPECTION TYPE:6C STA 933 TO 970, RBL 11 TO RBL 33, MC FLOOR PANEL FOUND DELAMINATION AND CRACK. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656302Fairing · delaminatedINSPECTION TYPE:6C LT WING O/B TRAILING EDGE FLAP L/E MID FAIRING DELAMINATION (2 PLACES) AT MID AREA. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-05 PAR 5A (1) FIG 5 REV 44.SDR IPXA09656301Flap · delaminatedINSPECTION TYPE:6C LT WING O/B TRAILING EDGE FLAP L/E MID FAIRING DELAMINATION AT O/B AREA. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-03 PAR 5A (1) FIG 5 REV 44.SDR IPXA09656300Fairing · delaminatedINSPECTION TYPE:6C LT WING O/B TRAILING EDGE FLAP L/E MID FAIRING DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-05 PAR 5C FIG 2 REV 44.SDR IPXA09656285Fairing · delaminatedINSPECTION TYPE:6C LT WING - I/B MAIN FLAP O/B LEADING EDGE FAIRING DELAMINATION. COMPOSITE WET LAY UP REPAIR CARRIED OUT AS PER SRM 51-70-03 PAR 5A (1) FIG 5, REV 44.SDR IPXA09656282Floor Panel · damagedINSPECTION TYPE:6C STN 283 - 412, RBL 78 TO RBL 88, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656281Floor Panel · damagedINSPECTION TYPE:6C STA 283 - 412, RBL 55 TO RBL 77, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656280Floor Panel · damagedINSPECTION TYPE:6C STN 544 - 654+22, LBL 11 TO RBL 11, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656279Floor Panel · damagedINSPECTION TYPE:6C STN 412 - 540, LBL 78 TO LBL 88 MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656278Floor Panel · damagedINSPECTION TYPE:6C STA 412 TO 530, LBL 11 TO RBL 11, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656277Floor Panel · damagedINSPECTION TYPE:6C STA 688 TO 764, RBL 78 TO RBL 88, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656276Floor Panel · damagedINSPECTION TYPE:6C STA 412 TO 540, LBL 55 TO LBL 77, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656275Floor Panel · damagedINSPECTION TYPE:6C STA 540 - 654 + 22, LBL 55 TO LBL 77, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656274Floor Panel · damagedINSPECTION TYPE:6C STA 544 TO 654 + 22, LBL 33 TO LBL 55, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656273Floor Panel · damagedINSPECTION TYPE:6C STA 730 - 833, LBL 11 TO RBL 11, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656272Floor Panel · damagedINSPECTION TYPE:6C STA 970 TO STA 1109, LBL 11 TO RBL 11 MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656271Floor Panel · damagedINSPECTION TYPE:6C STN 933 TO 970, LBL 11 TO RBL 11, MCD FLOOR PANEL FOUND DAMAGED. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.