What was found
FWD EQUIP COOLING OVERHEAT MSG. T/S REF FIM 21-58-00 FIG 115 INSP C/O EQUIPMENT COOLING SYS SUPPLY FAN & EXHAUST FAN INLET SCREEN, EQUIPMENT COOLING MANIFOLD INTER- CONNECT VALVE & MIXING MANIFOLD ALL OKAY. FWD RACK LOW FLOW DETECTOR & EXHAUST FAN REPLACED. K2207 & K2199 RELAYS REPLACED REF AMM 21-58-17, -22, -06, -00.