N325US
Service difficulty reports · 225
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N325US' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N325US' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026102105779Latch · brokenOXYGEN PANEL LATCH BROKEN. OPENED DURING TAKEOFF. UPPER AND LOWER LATCHES ARE DAMAGED AND WILL NOT CLOSE PROPERLY. THE PANEL APPEARS TO BE MISALIGNED, LEAVING THE MASKS EXPOSED. C/A: RESECURED O2 MASK BOX AND LATCH AS REQ. MASK DROP TEST GOOD. A/C OK FOR SVC. SDR DALA2026100105463Light · inoperativeCEILING EMERGENCY LIGHT AT ROW 28 INOPERATIVE. R & R LIGHT ASSEMBLY REF A320 AMM 33-51. OPS CHECK GOOD. (LP: 9473980, AIRCRAFT WAS GROUNDED)SDR DALA2026072904388Electrical Box · odorSMOKE - PASSENGER REPORTED VISIBLE SMOKE FROM FLOOR LEVEL AT ROW 4 DURING PUSHBACK. REPLACED BURNED IFE DCSEB AND HARNESS AT ROW 3C/D. (LP: 8928612, AIRCRAFT WAS GROUNDED)SDR DALA2026060103312Unknown · odorONCOMING FA'S REPORTED WET SOCK ODOR. C/W A320 AMDS W/C 0550-2002 STEPS 1-4-CONTACTED MCC-C/W W/C 2100 -2007 LEVEL "A" DECONTAMINATION-ALL CHECKS GOOD-P-TRAK SNIFFER TEST SHOWS IN GOOD/LOW RANGE-A/C OK FOR SERVICE-SEE ITEM LOG 8834161 CONTROL # 1621231 FOR DESDR DALA2026042502628Structure · damagedBURRED MATERIAL (OVALIZATION) ON LOWER LATERAL FITTING RH SIDE RACK 80 VU ADDITIONAL ENGINEERING DOCUMENTATION IS REQUIRED PRIOR TO FURTHER F LIGHT REFER TO AA CARD 2515-01014-02B AD RELEATED. C/A: COMPLIED ER/A 633348-14AD REV ORIGINAL WAS VERIFIED AGAINST RESDR DALA2026042502626Structure · damagedBURRED MATERIAL (OVALIZATION) ON LOWER LATERAL FITTING RT SIDE RACK 80 VU ADDITIONAL ENGINEERING DOC IS REQUIRED PRIOR TO FURTHER FLT, REFER TO AA CARD 2515-01014-02B AD RELEATED. COMPLIED ER/A 633348-14AD, REV ORIGINAL WAS VERIFIED AGAINST REPAIR INST ER/A 6SDR DALA2025122209273Oil System · leakingON ARRIVAL DESCENT WE NOTICED A MUSTY ODOR FROM PACKS. THE SMELL WOULD COME AND GO. THE ODOR LEFT AND THEM CAME BACK AND WE NOTICED THE ODOR AT THE GATE AFTER SHUTDOWN. FA'S IN THE CABIN NOTICED IT THE MOST IN FWD GALLEY. C/A: C/W W/C 0550-2002. FOUND APU INLESDR DALA2025120808925Condenser · odorFA REPORTED FIRE ALARM IN CABIN. FA REPORTED SMELL OF SMOKE. PILOTS SMELLED SMOKE, BUT NO VISIBLE SMOKE. RETURNED TO GATE. C/A: LOUD SQUEAL AROUND ROW 30-31, NOISE WENT AWAY WHEN PACKS TURNED OFF. R & R LT PACK CONDENSOR REF A320 AMM 21-52. OPS NORMAL AT THIS SDR DALA2025111808415Gust Lock · inoperativeL2 DOOR GUST LOCK NOT LATCHING. R & R GUST LOCK IAW AMM 52-13-12. (8036542).SDR DALA2025101307454Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED. STRUCK BY CARRIER IN 504R, CAUSING IT TO DEPLOY. C/A: RESTOWED O2 MASK AT LOCATION 401PER A320 AMM 35-30OK FOR SERVICE. (LP: 1248583)SDR DALA2025092907024Skin · no discrepancyDAMAGE TOLERANCE EVALUATION (DTE) REQUIRED. ER/A 629295-14 SECTION I ISSUED FOR A FUSELAGE SKIN REPAIR AT FR 69-FR 70, S- 28R TO S-32R. SECTION I, ACCOMPLISHED DURING MSP LINE VISIT 23SEP25. FOLLOW ON ACTION IS REQUIRED. REPAIR APPROVAL IS LIMITED TO 200 FCSDR DALA2025092907023Skin · corrodedWHILE WALKING PAST THE ACFT, NOTICED CORROSION AROUND THE WASTE TANK VACUUM GENERATOR EXHAUST PORT. REMOVED EXISTING FASTENERS IN REPAIR A320 SRM 53-41-11 WIP .145518. WORKING REPAIR ON ERA 629295-14. -728756. COMPLETED REPAIR ON ERA 629295-14. OPS CHECK OF LSDR DALA2025080405805Oxygen Panel · openL, DOOR OXYGEN PANEL OPENED BUT MASKS DID NOT FALL OUT. CLOSED 2L DOOR O2 MASK PANEL.SDR DALA2025080405804Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED, DOOR OPENED BUT MASKS DID NOT FALL OUT . 2L DOOR. MASK DID NOT DEPLOY. COVER AT 2L F/A SEAT O2 FELL OPEN. REINSTALLED COVER. A/C OK FOR SERVICE.SDR DALA2025080405803Oxygen Mask · unwanted deployOXYGEN MASK DEPLOYED, FLOW OF OXYGEN NOT RELEASED. CLOSED OXYGEN DOOR PER A320 AMM 35-21.SDR DALA2025071005195Latch · malfunctionedSHIP 3225 DISC: THE LOCKING LATCH IS DOWN, EXPOSING ORANGE WARNING STICKER ON THE LATCH. MASKS NOT FULLY DEPLOYED, OXYGEN PANEL MASK DEPLOYED. C/A: MASKS NOT DEPLOYED AT ALL. DOOR SECURE. RESET LATCH. SECURED. OK FOR SVC. (LP: 1061299)SDR DALA2025062604776Light · no discrepancySHIP 3225 DISC: OVHD EMERGENCY LIGHT INOP AT ROW 28. C/A: FWD TO MEL 33-50-02B. COMPLETED OPERATIONAL TEST OF EMERGENCY LIGHTS PER A320 AMM 33- 51. NO FAULT FOUND WITH OVHD EMERGENCY LIGHT. PLACARD REMOVED. (LP: 7718404)SDR DALA2025060104195Unknown · odorSHIP 3225 DISC: ON DESCENT INTO SAT, "DIRTY SOCK SMELL" IN COCKPIT. BOTH PILOTS WENT ON O2 FOR REMAINDER OF FLIGHT; AT GATE SMELL WAS NO LONGER PRESENT. AN EMERGENCY WAS DECLARED WITH ATC. C/A: REF LOG 0992664 FOR WORK PERFORMED. A/C OK FOR SVC. (LP: 7383286)SDR DALA2025052403993Oxygen Panel · looseSHIP 3225 DISC: OXYGEN PANEL OVER GALLEY COUNTER IS LOOSE. C/A: RESTOWED OXYGEN PANEL W/MASK. IAW A320 AMM 35-20, A/C OK FOR SVC. (LP: 0978266)SDR DALA2025050103354Oxygen Mask · dislodgedSHIP 3225 DISC: AFT GALLEY OXYGEN MASKS FELL DOWN DURING TAKEOFF. C/A: INSPECTED AND FOUND TUBE IN DOOR ASSY, O2 GEN LOOKS GOOD PINS STILL INSTALLED. REPACKED MASK IN BOX PER A320 AMM 35-21. DOOR SECURE. OK FOR SERVICE. (LP: 7544326)SDR DALA2025042703259Oxygen Mask · dislodgedSHIP 3225 DISC: AFT GALLEY OXYGEN MASKS FELL DOWN DURING TAKEOFF. C/A: REPACKED AFT GALLEY OXYGEN MASK ASSEMBLY IAW A320 AMM 35-21. OPS CK GOOD, OK FOR SVC. (LP: 7544320)SDR DALA2025040602614Oxygen Panel · openSHIP 3225 DISC: PANEL NEXT TO AFT L DOOR IN GALLEY FLEW OPEN ON TAKEOFF. C/A: RESECURED O2 PANEL IAW A319 35-21. (LP: 0895227)SDR DALA2025040802694Oil Cap · leakingSHIP 3225 DISC: DUE TO REPORT OF OIL FUMES IN THE CABIN. C/A: CLEANED RESIDUAL OIL FROM UNDER COWL, OPEN APU COWL FOUND OIL CAP AREA FULL OF OIL. GOT OIL FUMES IN CABIN ON APU START. INSPECTED APU DUCTS AND FOUND OIL COMING FROM COOLING FAN. R/R APU COOLING FASDR DALA2025033002337Light · inoperativeAIRCRAFT 3225, OVHD EMERGENCY LIGHT INOP AT ROW 28 ON SVC CK. CORRECTIVE ACTION: REPLACED EMERGENCY LIGHT PER A320 AMM 33-51, OPS CHECK GOOD. (LP 7206974)SDR DALA2025031501998Oxygen Mask · unwanted deploySHIP 3225 DISC: O2 MASK FELL DOWN AFT GALLEY. C/A: INSPECTED O2 MASK AND RESTOWED IAW A320 AMM 35-21. A/C OK FOR SERVICE. (LP: 7206900)SDR DALA2025021601167Oxygen Panel · openSHIP 3225 DISC: AFT GALLEY O2 MAKS COMPARTMENT OPENED. MASKS DID NOT DROP. C/A: RE-SECURED AFT GALLEY O2 MASK COMP DOOR PER A320 AMM 35-21. OK FOR SVC. (LP: 6830174)SDR DALA2025021601166Oxygen Panel · openSHIP 3225 DISC: OXYGEN PANNEL ABOVE 2L DOOR IN AFT GALLEY POPPED OPEN MID FLIGHT. C/A: 2L AFT LEFT GALLEY OXYGEN PANEL RE-SECURED AS REQUIRED OK FOR SVC. (LP: 0798641)SDR DALA2025020700958Unknown · odorSHIP 3225 DISC: WALKED ONTO PLANE AND COULD SMELL RESIDUAL DIRTY SOCK SMELL I TURNED ON THE APU AND TURNED ON APU BLEED AND DIRTY SOCKS SMELL GOT WORSE. C/A: FOUND APU OVERSERVICED AND EVIDENCE OF OIL INGESTION INTO APU INLET NO LEAKS NOTED ON VISUAL INSP PERFSDR DALA2025013000721Cover · detachedSHIP 3225 DISC: OVERHEAD O2 MASK PANEL COVER IN AFT GALLEY CAME OFF ON TAKEOFF. C/A: SECURED O2 COVERS IN AFT GALLEY, A/C OK FOR SERVICE. (LP: 5662083)SDR DALA2025012100512Apu · contaminatedSHIP 3225 DISC: DIRTY SOCK SMELL ON SHORT FINAL. TURNED INTO WET PAINT SMELL AFTER LANDING. C/A: PERFORMED DETAILED INSP OF ENG'S AND APU. FOUND COPIOUS AMOUNTS OF DE-ICING FLUID IN APU INLET AND BIRD CAGE. CLEANED APU INLET AND SURROUNDING AREA (959196). C/W SDR DALA2024121711764Unknown · odorSMOKE/LAV WARNING AT FL 300 TOD LEAD FA REPORTED A SLIGHT SMELL OF SMOKE BRIEFLY FROM 1ST CLASS LAV UNDER SINK. DISAPATED QUICKLY. NO EVIDENCE OF SMOKE OR RESIDUAL CHARRING, ETC. C/W NO-GO ODI PROCESS PER TSM 05-50. DETERMINED TO BE TYPE10 EVENT. DETERMINED TSDR DALA2024120511468Apu · smokeSHIP 3225 - ATB - DUE TO REPORTS OF SMOKE AND STRONG GLYCOL SMELL IN THE CABIN. CORRECTIVE ACTION: FOUND EVIDENCE OF DEICE FLUID INGESTION IN APU AND PACKS. PERFORMED APU AND ECS SYSTEMS DECONTAMINATION. (LP: 6766066)SDR DALA2024120211304Battery Pack · inoperativeSHIP 3225 DISC: DURING EMERGENCY LIGHTS TEST, INT. LOADS AFT L FAILURE MESSAGE OCCURED. C/A: REMOVED AND REPLACED 13WL EPSU BATTERY IAW A320 AMM 33-51-38. OPS CHECK GOOD. (LP: 6766057)SDR DALA2024111911034Oxygen Mask · unwanted deploySHIP 3225 DISC: OXYGEN PANEL MASK DEPLOYED / LOCATIONS:401. PANEL OPENED COMPLETELY AFTER TAKEOFF MASK DID NOT ACTUALLY DEPLOY. C/A: VERIFIED O2 GENERATOR DID NOT DEPLOY. RESECURED O2 MASK PANEL REF A320 AMM 35-20. OK FOR SVC. (LP: 0658931)SDR DALA2024102110223Oxygen Mask · unwanted deploySHIP 3225 DISC: AFT GALLEY 02 MASKS DEPLOYED DURING TAKEOFF. C/A: -REPOSITIONED AFT GALLEY O2 MASKS INSIDE COMPARTMENT SECURED WITH IT'S RESPECTIVE VELCRO AND RESECURED LID ALL I/A/W A320 A.M.M. #35-20. PIN FOR O2 GENERATORS NOT PULLED. A/C GOOD TO CONTINUE SESDR DALA2024102010214Light · malfunctionedSHIP 3225 DISC: ROW 2T/S PER A320 TSM 33-51-00-810-810-A. RESET PWR, EMERGENCY LIGHTING OPERATIONAL TEST NORMAL. ROW 28 OVHD EMERGENCY LIGHT FUNCTION NORMAL AT THIS TIME. JOB COMPLETE, OK FOR SVC. 8 OVERHEAD EMERGENCY LIGHT INOP. C/A: FWD TO MEL 33-50-02B. NO SDR DALA2024071207047Cooling Fan · leakingSHIP 3225 DISC: PILOT REPORT DIRTY SOCK SMELL IN CABIN. C/A: FOUND APU COOLING FAN LEAKING NIS ATL C/W W/C 4916-2001. C/W W/C 0550-2002 IDENTIFY SOURCE C/W W/C 4916-2001 APU COMPARTMENT CLEANING C/W LEVEL A ECS DECONTAMINATION PER W/C 2100-2007 NO SMELLS NOTEDSDR DALA2024071207046O-Ring · leakingSHIP 3225 DISC: AIRCRAFT HAS DIRTY SOCK SMELL. C/A: C/W AMDS W/C 7900-2001 UP TO STEP 4. (523380) R/R LPT SHAFT PLUG ORING ON NBR 2 ENG PER A320 AMM 72-55(7657010 FINISHED C/W AMDS W/C 7900-2001, AND 2100-2003. SMELL NO LONGER PRESENT. OK FOR SVC. (LP: 6130490SDR DALA2024070406752Oil System · leakingAPU OIL FOUND LEAKING ON WALK AROUND. WHEN USING APU BLEED, MUSTY SMELL CAN BE OBSERVED. NO EXTERNAL LEAKS FOUND. SUSPECT THE LEAK IS INTERNAL. APU R/R ON AMDS FORECAST 32-4910-9-0010 CARD #4900-9001. C/W ECS DECONTAMINATION PER WC 2100-2003. C/W MD LOG NO GOSDR DALA2024061906213Oil Cooler · leakingSHIP 3225 DISC: AFTER LANDING, WHILE TAXING TO THE GATE, PILOTS NOTICED A FUNKY SMELL COMING FROM THE AIR CONDITIONING PACKS. APU WAS OFF DURING TAXI IN. C/A: FOUND OIL AROUND APU DOOR AND INLET , INSPECTED APU PER W/C 4900 -2001. FOUND COOLING FAN OF OIL COOLSDR DALA2024042904747Light · malfunctionedSHIP 3225 DISC: EMER SYS FAULT - "INT LOADS EMER R" AND "INT LOADS AFT L. C/A: PERFORMED RESET OF EMER LIGHT SYS PER A320 AMM 33-51. NO FAULTS. (LP: 5351848)SDR DALA2024041504406Damper · no testDONT PASS OPERATIONAL TEST EMERGENCY DOOR DAMPER ON PASSENGER CREW DOO R 831 AT FWD GALLEY AREA. REPLACED DOOR DAMPER. RII INSPECTION COMPLETE (AE406QC). JOB COMPLETE.SDR DALA2024040804145Damper · no testSHIP 3225 DISC: DONT PASS TEST DOOR DAMPER ON PASSENGER CREW DOOR 841 (REFER TO AMDS C ARD 5210-7089-RF) RII STEP 11 AT FWD GALLEY AREA. C/A: REPLACED EMERGENCY DOOR DAMPER. JOB COMPLETE (LP: 0274669)SDR DALA2024040804144Damper · no testSHIP 3225 DISC: DONT PASS OPERATIONAL TEST EMERGENCY DOOR DAMPER ON PASSENGER CREW DOO R 832 (REFER TO AMDS CARD 5210-7089-LA RII). C/A: REPLACED EMERGENCY DOOR DAMPER. JOB COMPLETE (LP: 0273457)SDR DALA2024022102452Bottle · low pressureSHIP 3225 DISC: ON WAKE-UP CIDS 1 CAUTION R OVERWING SLIDE PRESSURE LOW. C/A: ACCESSED AFT CARGO RT SIDE FOUND OVERWING PRESSURE BOTTLE LOW WIP 414302. REMOVED AND REPLACED RT OVERWING SLIDE BOTTLE IAW AMDS W/C 2562-2001-RH. (WIP 560510) RII COMPLIED WITH 6416SDR DALA2023110709188Unknown · unknownSHIP 3225 DISCR: EMERGENCY EXIT SIGNS INOPERATIVE C/A: PERFORMED OPS CHECK PER A320 AMM 33-51. OPS CHECK GOOD. OK FOR SVC. (LP0051671)SDR DALA2023110309073Unknown · unknownSHIP 3225 DISC: DOOR 1 RIGHT WOULD NOT ARM. C/A: REMOVED OBSTRUCTION FROM GIRTBAR SLOT AREA AS NECESSARY. OPS CHK GOOD. LP 4336982SDR DALA2023053104341Unknown · unknownSHIP 3225 - ATB- PERFORMED AIR TURN BACK TO DTW DUE TO NUMBER 1 ENG OVER-TEMP. CREW PULLED THE THROTTLE BACK BUT EGT DID NOT SUBSIDE. CORRECTIVE ACTION: REPLACED ENGINE PER WORK CARD 7100-9901-LT. OPS AND LEAK CHECK GOOD. (4690742)SDR DALA2023020300846Not Entered · not enteredSHIP 3225 - SMKE - AFTER LANDING WHILE APU STARTING, VISIBLE SMOKE OCCURRED IN CABIN. CORRECTIVE ACTION: FOUND APU INLET CONTAMINATED WITH OIL FROM AN EXTERNAL APU OIL LEAK. APU PLACED ON MEL. COMPLIED WITH AMDS 0550-2002 AND 2100-2005. REPLACED RIGHT OZONE FISDR DALA2022122008240Actuator · inoperativeSHIP 3225 AT 190 KTS APPROX 5000 FT MSL AND FLAPS 2 WE HAD AN UNCOMMANDED ROLL TO THE RIGHT AT APROX 10 DEG OF BANK WHEN THE SPEED BRAKE WAS EXTENDED THE ROLL LASTED APPROX 10 SECONDS BEFORE THE A/C REVERSED THE TURN TO THE LEFT TO RECAPTURE THE NAV PATH-AUTOP
Back to N325US